• Title/Summary/Keyword: Residual Test

Search Result 1,822, Processing Time 0.035 seconds

Application of Continuous Indentation Technique for Reliability Evaluation in Power Plant Facilities (발전설비 주요배관 신뢰도 확보를 위한 연속압입시험 적용)

  • Park, Sang-Ki;Ahn, Yeon-Shik;Jung, Gye-Jo;Cho, Yong-Sang;Choi, Yeol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.158-162
    • /
    • 2004
  • Reliability of welded structures in power plant facilities is very important, and their reliability evaluation requires exact materials properties. But, the conventional PQR (Procedure Qualification Record) can hardly reflect the real material properties in the field because the test is only done on specimens with simulated welding. Therefore, a continuous indentation technique is proposed in this study for simple and non-destructive testing of in-field structures. This test measures the indentation load-depth curve during indentation and analyzes the mechanical properties such as the yield strength, tensile strength and work hardening index. This technique has been applied to evaluate the tensile properties of the weldment in the main steam pipe and hot reheater pipe in power plants under construction and in operation.

A Study on Nano/micro Pattern Fabrication of Metals by Using Mechanical Machining and Selective Deposition Technique (기계적 가공과 무전해 선택적 증착기술을 이용한 나노/마이크로 금속패턴 제작에 관한 연구)

  • Cho S.H.;Youn S.W.;Kang C.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1507-1510
    • /
    • 2005
  • This study was carried out as a part of the research on the development of a maskless and electroless process for fabricating metal micro/nanostructures by using a nanoindenter and an electroless deposition technique. $2-\mu{m}-deep$ indentation tests on Ni and Cu samples were performed. The elastic recovery of the Ni and Cu was 9.30% and 9.53% of the maximum penetration depth, respectively. The hardness and the elastic modulus were 1.56 GPa and 120 GPa for Ni and 1.49 GPa and 100 GPa for Cu. The effect of single-point diamond machining conditions such as the Berkovich tip orientation (0, 45, and $90^{\circ}$) and the normal load (0.1, 0.3, 0.5, 1, 3, and 5 mN), on both the deformation behavior and the morphology of cutting traces (such as width and depth) was investigated by constant-load scratch tests. The tip orientation had a significant influence on the coefficient of friction, which varied from 0.52-0.66 for Ni and from 0.46-0.61 for Cu. The crisscross-pattern sample showed that the tip orientation strongly affects the surface quality of the machined area during scratching. A selective deposition of Cu at the pit-like defect on a p-type Si(111) surface was also investigated. Preferential deposition of the Cu occurred at the surface defect sites of silicon wafers, indicating that those defect sites act as active sites for the deposition reaction. The shape of the Cu-deposited area was almost the same as that of the residual stress field.

  • PDF

Experimentally Evaluating Fatigue Behavior of Corroded Steels Exposed in Atmospheric Environments (대기환경하에서 장기간 사용된 부식강재의 실험적 피로거동평가)

  • Mun, Jae Min;Jeong, Young Soo;Jeon, Je Hyeong;Ahn, Jin Hee;Kim, In Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.3
    • /
    • pp.193-204
    • /
    • 2017
  • Fatigue strength of temporary steels and painted structural steels corroded under outdoor atmospheric environments is not clear. In this study, fatigue tests were carried out on steel plates which were cut off from 7-year-old temporary structural member under subway construction environment and from 75-year-old Yeongdo bridge member under marine atmospheric environment. After removing corrosion production on the steel surface, 3-dimensional surface geometry of the corroded steel was measured at intervals of $1.0{\times}1.0mm$, and corrosion characteristics such as minimum, maximum and mean values of residual thicknesses were calculated. From the fatigue test and FEM analysis results, the relationship between corrosion characteristics and fatigue behavior was presented, and change in fatigue strength of the unpainted and painted steels corroded in outdoor environments was also presented.

Purification of Antioxidant substance from the stem bark of Rhus verniciflua

  • Kim, Jung-Bae
    • Proceedings of the Korean Journal of Food and Nutrition Conference
    • /
    • 2001.12a
    • /
    • pp.126-126
    • /
    • 2001
  • The Rhus verniciflua contains alkly(en)-catechol type allergens with a saiurated or unsaturated alkly chain of 15 or 17 carbon atoms. It has been recognized as an extremely active allergen causing skin reactions similar In poison ivy. The allergic contact dermatitis induced by the urushiol is known to be mediated be T lymphocytes whicht specifically recognize the hepten urushiol. Therefore. direct use of this plant as a medicinal purpose might imply a considerable hazard in Korea. In this study, using the established method for the detoxification from the stem bark of Rhus verniciflua, an strong antioxidant substance was isolated and characterized DPPH (diphenypricryl hydrazyl) assay measures hydrogen atom-donating activity and hence provides a measure of free radical scavenging antioxidant activity. DPPH, a purple-colored stable free radical, is reduced to yellow-colored diphenylpicryl hydrazine by antioxidants to deducing agents. Antioxidative effects of the water extract from RV were measured by DPPH assay. Twenty microliters of the extract was added to 1ml of 100mM DPPH solution in ethanol The mixture was shaken and left to stand for 10min at room temperature. The crude water extracts was purified by using HPLC method with a DEAE (anionic type), CN, ODS column. The purified compound remained stable at pH 3.0-6,0, but unstable above pH 6.5. It was stable heat at 10$0^{\circ}C$ for 4 hours, but still had about 80% of residual activity after treatment at 10$0^{\circ}C$ for 5 hours. The elemental composition of the HR-EI mass spectrum at m/z 170.02 was estimated the empirical formula as $C_{7}$ $H_{6}$ $O_{5}$. $C_{10}$ $H_4$ $O_2$N$_1$, $C_{5}$ $H_4$ $O_4$N$_3$, $C_{8}$$H_2O$$_1$N$_4$. In antimicrobial test, no inhibition was observed against Gram-positive and negative bacteria. This compound was stronger than that of commercial antioxidant by DPPH test, such as BHT, BHC at the same concentration (20$\mu$g/ml).ml).

  • PDF

Development of a Nutrition Quotient (NQ) equation modeling for children and the evaluation of its construct validity (어린이 영양지수 (NQ, Nutrition Quotient) 모형 개발과 구성타당도 평가)

  • Kim, Hye-Young;Kwon, Se-Hyug;Lee, Jung-Sug;Choi, Young-Sun;Chung, Hae-Rang;Kwak, Tong-Kyung;Park, Ju-Yeon;Kang, Myung-Hee
    • Journal of Nutrition and Health
    • /
    • v.45 no.4
    • /
    • pp.390-399
    • /
    • 2012
  • The objective of this study was to develop and evaluate the construct validity of a Nutrition Quotient (NQ) for children. In a previous report (Kang, et al., 2012), the food behavior checklist for children's NQ, consisting of 19 items, was grouped into a 5-factor structure according to the exploratory factor analysis: balance, diversity, moderation, regularity, and practice. In this study, the construct validity of the NQ was assessed using a confirmatory factor analysis. Elementary school students (n = 1,393) from six large cities completed the NQ test. Indicator tests suggested an adequate model fit (goodness of fit index = 0.9613; adjusted GFI = 0.95; standardized root mean square residual = 0.0464; chi-square test statistics of < 0.001 p-value, 82.1), and item loadings were significant for all subscales (p < 0.05). The standardized path coefficients were used as the weights of the items. The NQ and the 5 factor scores of the student were calculated by the obtained weights of the questionnaire items. Logistic regression was applied to find the significant factors in order to affect a specific nutrient status. The receiver operation characteristic curve analyses were performed in order to find diagnostic cut-off points of the five factors. The food behavior checklist for children's NQ would be a handy and suitable instrument for evaluating dietary behaviors of Korean children.

Real-Time Bandwidth Management Service for Effective Multiple Isochronous Streaming Transmission in IEEE1394 based Home Network (IEEE1394 기반 홈네트워크에서 효율적인 다중 등시성 스트리밍 전송을 위한 실시간 대역폭 관리 서비스)

  • Chae Hwa-Young;Jung Gi-Hoon;Kang Soon-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9B
    • /
    • pp.838-847
    • /
    • 2006
  • In order to support multiple multimedia streaming services in home networks, many critical issues must be considered. In addition, handling the shortage of network bandwidth is one of the most significant and complicated issues. In this paper, real-time bandwidth management service is suggested as a solution to the problem regarding the IEEE1394-based home network. In order to handle the shortage of network bandwidth and to enhance the bus utilization rate, the proposed service combines two methods. First, the bus bandwidth management function determines the state of the network bandwidth and restores the residual bandwidth, which is excessively occupied by a streaming service, to the available free bandwidth. Second, the Isochronous Streaming (IS) Scheduler manages all streaming services according to priority. In order to test the proposed service, we implemented a prototype steaming management middleware and evaluated it by using the IEEE1394 network test-bed.

The Ejector Design and Test for 5kW Molten Carbonate Fuel Cell (75kW 용융탄산염 연료전지 시스템의 MBOP 개발)

  • Kim, Beom-Joo;Kim, Do-Hyung;Lee, Jung-Hyun;Kang, Seung-Won;Lim, Hee-Chun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.353-356
    • /
    • 2009
  • A pivotal mechanical balance of plant for 75kW class molten carbonate fuel cells comprise of a catalytic burner and an ejector which has been designed and tested in KEPRI(Korea Electric Power Research Institute). The catalytic burner, which oxidizes residual fuel in the anode tail gas, was operated at several conditions. Some problems arose due to local overheating or auto-ignition, which could limit the catalyst life. The catalytic burner was designed by considering both gas mixing and gas velocity. Test results showed that the temperature distribution is very uniform. In addition, an ejector is a fluid machinery to be utilized for mixing fluids, maintaining vacuum, and transporting them. The ejector is placed at mixing point between the anode off gas and the cathode off gas or the fresh air Several ejectors were designed and tested to form a suction on the fuel tail gas and balance the differential pressures between anode and cathode over a range of operating conditions. The tests showed that the design of the nozzle and throat played an important role in balancing the anode tail and cathode inlet gas pressures. The 75kW MCFC system built in our ejector and catalytic burner was successfully operated from Novembe, 2008 to April, 2009. It recorded the voltage of 104V at the current of 754A and reached the maximum generating power of 78.5kW DC. The results for both stand-alone and integration into another balance of plant are discussed.

  • PDF

Buckling Strength of Concentrically Loaded High-Strength Steel Columns with Intermediate Slenderness (중심압축을 받는 고강도강 중간주의 좌굴강도 평가)

  • Kim, Dae Kyung;Lee, Cheol Ho;Han, Kyu Hong;Kim, Jin Ho;Lee, Seung Eun;Kim, Jin Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.4
    • /
    • pp.377-386
    • /
    • 2015
  • In this study, inelastic buckling strength of HSA800 steel columns were tested to investigate the applicability of current column curve (KBC2009, 2010 AISC-LRFD) to HSA800 steel. Key test variables included width-thickness ratio, plate-edge restraints, and column slenderness ratio. Specimens made of ordinary steel (SM490) were also tested for comparison purposes. All the concentrically loaded HSA800 specimens exhibited sufficient buckling strength compared to the current column curve, but some of SM490 specimens showed understrength. This difference can be explained by the lower residual stress present in HSA800 specimens.

Assessment of Groundwater Quality for Irrigation and Agro-based Industrial Usage in Selected Aquifers of Bangladesh

  • Rahman, Md. Mokhlesur;Hoque, Syed Munerul;Jesmin, Sabina;Rahman, Md. Siddiqur;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.2
    • /
    • pp.98-105
    • /
    • 2005
  • Groundwater sampled from 24 tube wells of three districts namely Sherpur, Gaibandha and Naogaon in Bangladesh was appraised for their water quality for irrigation and agro-based industrial usage. All waters under test were slightly alkaline to alkaline (pH = 7.2 to 8.4) in nature and were not problematic for crop production. As total dissolved solid (TDS), all groundwater samples were classified as fresh water (TDS<1,000 mg/L) in quality. Electrical conductivity (EC) and sodium adsorption ratio (SAR) values reflected that waters under test were under medium salinity (C2), high salinity (C3) and also low alkalinity (S1) hazard classes expressed as C2S1 and C3S1. As regards to EC and soluble sodium percentage (SSP), groundwater samples were graded as good and permissible in category based on soil properties and crop growth. All water samples were free from residual sodium carbonate (RSC) and belonged to suitable in category. Water samples were under soft moderately hard, hard and very hard classes. Manganese, bicarbonate and nitrate ions were considered as major pollutants in some water samples and might pose threat in soil ecosystem for long-term irrigation. For most of the agro-based industrial usage, Fe and Cl were considered as troublesome ions. On the basis of TDS and hardness, groundwater samples were not suitable for specific industry. Some water samples were found suitable for specific industry but none of these waters were suitable for all industries. The relationship between water quality parameters and major ions was established. The correlation between major ionic constituents like Ca, Mg, K, Na, $HCO_3$ and Cl differed significantly. Dominant synergistic relationships were observed between EC-TDS, SAR-SSP, EC-Hardness, TDS-Hardness and RSC-Hardness.

Tensile strength evaluation of SFRC subjected to high temperature using double punch test (DPT 실험을 이용한 고온노출된 강섬유보강콘크리트의 인장강도 평가)

  • Moon, Do-Young;Chang, Soo-Ho;Bae, Gyu-Jin;Lee, Gyu-Pil;Kim, Hee-Sung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Steel fiber-reinforced concrete (SFRC) is widely used for tunnel lining structure such as shot-crete in NATM tunnel and segment in TBM tunnel. In tunnel fire accidents, structural performance of a lining is very important because the lining is the structure that directly exposed to fire. In this study, the effects of high temperatures, mix ratios and types on failure pattern, DPT tensile strength and coefficient of variation were investigated through Double Punch Tests (DPT) of SFRC subjected to high temperatures. In the results, it is confirmed that the residual DPT tensile strength increases as for SFRC and this is more in SFRC with higher mix ratio. But, the equation for evaluation of DPT tensile strength does not involve the number of failure surfaces SFRC specimens subjected to high temperatures, therefore, it is required to investigate more fracture energy in DPT tests.