• Title/Summary/Keyword: Residual Gas

Search Result 575, Processing Time 0.027 seconds

Bahavior of Some Herbicides Applied to Oil-bearing Crops (유지작물(油脂作物)에 시용(施用)한 몇가지 제초제(除草劑)의 행방(行方))

  • Kim, Yong-Hwa;Kang, Soon-Young;Lee, Su-Rae
    • Applied Biological Chemistry
    • /
    • v.21 no.3
    • /
    • pp.185-192
    • /
    • 1978
  • Three herbicides including nitrofen, alachlor and butachlor f?ere applied to farm soils of oil-bearing crops rape, soybean and paddy rice and their residual levels in the soil and seeds were determined by ECD-attached gas chromatograph without hydrolysis. Applied herbicides were decreased abruptly 2 weeks after application and slowly thereafter, reaching below 10% level while the extent of disappearance varied depending on the herbicides, crops and soil conditions. The herbicides were not detected at all in the seeds of tested crops within the detection limit of the analytical methods employed.

  • PDF

High Temperature Fiber Fragmentation Characteristics of SiC Single-Fiber Composite With Titanium Matrices

  • Matikas, Theodore E.
    • Advanced Composite Materials
    • /
    • v.17 no.1
    • /
    • pp.75-87
    • /
    • 2008
  • Aerospace structural applications, along with high performance marine and automotive applications, require high-strength efficiency, which can be achieved using metal matrix composites (MMCs). Rotating components, such as jet-engine blades and gas turbine parts, require materials that maximize strength efficiency and metallurgical stability at elevated temperatures. Titanium matrix composites (TMCs) are well suited in such applications, since they offer an enhanced resistance to temperature effects as well as corrosion resistance, in addition to optimum strength efficiency. The overall behavior of the composite system largly depends on the properties of the interface between fiber and matrix. Characterization of the fiber.matrix interface at operating temperatures is therefore essential for the developemt of these materials. The fiber fragmentation test shows good reproducibility of results in determining interface properties. This paper deals with the evaluation of fiber fragmentation characteristics in TMCs at elevated temperature and the results are compared with tests at ambient temperature. It was observed that tensile testing at $650^{\circ}C$ of single-fiber TMCs led to limited fiber fragmentation behavior. This indicates that the load transfer from the matrix to the fiber occurs due to interfacial friction, arising predominantly from mechanical clamping of the fiber by radial compressive residual and Poisson stresses. The present work also demonstrates that composite processing conditions can significantly affect the nature of the fiber.matrix interface and the resulting fragmentation of the fiber.

Characteristics of Machined Surface Roughness and Surface Layers of WC-Co Tools with Plasma Source Ion Implantation (WC-Co 공구의 이온 주입에 따른 표면층 및 가공된 표면거칠기 특성)

  • Kang, Seong-Ki;Kim, Yung-Kyu;Wang, Duck-Hyun;Chun, Young-Rok;Kim, Won-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.106-113
    • /
    • 2010
  • The most suitable condition for plasma source ion implantation(PSII) was found based on the study of the characteristics of PSIIed tool and machined surfaces. The depth analysis according to the chemical bonding state of elements and surface component elements through the XPS and SIMS, was conducted to find the improved property of the PSIIed surface. Due to the diffusion of PSII, the nitrogen was found up to a depth of about 150nm according to the supplied voltage and ion implanted time. The deep diffusion by nitrogen caused the surface modification, but the formation of oxide component was found due to the residual gas contamination on the surface. Statistical method of ANOVA was conducted to find the effects of spindle speed and feed rate in interaction for machined surface roughness with PSIIed tools. The surface modification was found largely occurred by the nitrogen implanted surface with 2 hours for 27kV, 35kV and 43kV.

Deep Space Maneuver by Microwave Discharge Ion Engines onboard "HAYABUSA" Asteroid Explorer

  • Kuninaka, Hitoshi;Nishiyama, Kazutaka;Shimizu, Yukio;Toki, Kyoichiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.306-313
    • /
    • 2004
  • The microwave discharge ion engine generates plasmas of both the main ion source and the neutralizer using 4㎓ microwave without discharge electrodes and hollow cathodes, so that long life and durability against oxygen and air are expected. The MUSES-C “HAYABUSA” asteroid explorer installing four microwave discharge ion engines “$\mu$10s” was launched into deep space by M-V rocket No.5 on May 9, 2003. After vacuum exposure and several runs of baking for reduction of residual gas the ion engine system established the continuous acceleration of the spacecraft toward the asteroid “ITOKAWA”. The Doppler shift measurement of the communication microwave revealed the performance of ion engines, which is 8mN thrust force for a single unit with 3,200sec specific impulse at 23mN/㎾ thrust power ratio. At the end of 2003 the accumulated operational time exceeded 8,000 hour and unit. HAYABUSA will execute the Earth swing-by on June 2004 and arrive at the asteroid in 2005 and return to Earth in 2007.

  • PDF

Glow discharge cleaning 법에 의한 stainless steel의 outgassing rate 감소

  • 임종연;이상균;서인용;최상철;홍승수;신용현;정광화
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.40-40
    • /
    • 1999
  • 가속기나 토카막과 같은 거대한 진공 장치의 용기 내벽을 청정화 하기 위해서는 용기 전체의 열처리(굽기, Baking)와 글로우 방전(Glow discharge) 법을 병행하여 사용한다. Baking은 일반 기체(N2, O2, 그리고 CO2)와 물(H2O)의 탈착에 효과적이고, Glow discharge cleaning은 탄소(Carbon-based)와 산소(Oxygen-based) 화합물의 탈착에 효과적이다. 특히 Glow discharge cleaning의 경우에는 전극의 모양, 진공 용기의 재질과 모양, 전극간의 거리, 사용되는 반응 기체의 압력 등에 따라 그 효과에 큰 차이가 있으므로 다각적인 연구가 필요하다. 본 연구에서는 그림 1과 같이 시험용 스테인레스(AISI 304와 AISI 316LN) 진공 용기를 설치하고, 시험 용기의 한쪽은 배기 용기와 oriffice로, 다른 편은 불순물의 정성.정량 분석을 위해 RGA(Residual gas analyser) 용기와 oriffice로 연결하였다. 전체 시스템 중에서 배기 부분과 분석 부분은 15$0^{\circ}C$에서 24시간 가열하여 전체의 기저 진공도를 1$\times$10-8Torr로 하였다. 기저 진공도의 용기에 고순도의 반응기체 (He, Ar, Ar+He, Ar+H2, Ar+N2 등)를 주입한후, DC 전압(0.8~1.5kV)을 변화하며 글로우 방전의 최적조건을 찾았다. 방전 동안 시험용 용기에서 방출되는 반응 기체 이외의 기체를 RGA로 측정하였고 외부에 Thermocouple을 여러곳에 장착하여 온도 변화를 측정하였다. 이상의 결과로부터 진공 용기 표면적으로부터의 불순물 탈착(desorption)과 불순물 분석, 플라즈마와 내벽의 상호작용등에 대한 결론을 얻을 수 있었다. 또한 Baking과 Glow discharge cleaning을 동시에 수행하여 Baking 온도의 낮춤에 따른 영향 평가도 수행하였다.

  • PDF

A study on the corrosion fatigue fracture behavior of ion-nitrided SM45C under alternating tension-compression loading (반복인장-압축하중을 받는 이온질화 처리한 SM45C의 부식피로 파괴거동에 관한 연구)

  • 우창기;김희송
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.451-460
    • /
    • 1989
  • This paper dealt with the effect of the ratios N2 to H2 gas on the corrosion fatigue failure behavior of ion-nitrided SM45C steel specimens. The specimens were water cooled after ion-nitriding at 500.deg. C for 3hrs in 5 Torr, 0.8N$_{2}$ and 0.5N$_{2}$ atmospheres. As the nitrogen concentration increases, the higher compressive residual stresses developed in the surface layer and the depth of nitrided layer increased, which in turn gave rise to increases in fatigue strength and corrosion fatigue life. In the region less than 1.5 * 10$^{5}$ cycles, fatigue failure initiated at the brittle nitrided case, whereas in the region higher than 1.5 * 10$^{5}$ cycles crack initiated from the non-metallic inclusions in the subsurface. The initiation of corrosion fatigue failure was mainly attributed to pitting of case hardened surface layer.

FINITE ELEMENT MODELING AND PARAMETER STUDY OF HALF-BEAD OF MLS CYLINDER HEAD GASKET

  • CHO S. S.;HAN B. K.;LEE J. H.;CHANG H.;KIM B. K.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.109-114
    • /
    • 2006
  • Half-beads of multi-layer-steel cylinder head gaskets take charge of sealing of lubrication oil and coolant between the cylinder head and the block. Since the head lifts off periodically due to the combustion gas pressure, both the dynamic sealing performance and the fatigue durability are essential for the gasket. A finite element model of the halfbead has been developed and verified with experimental data. The half-bead forming process was included in the model to consider the residual stress effects. The model is employed to assess the dependence of the sealing performance and the fatigue durability on the design parameters of half-bead such as the width and height of bead and the flat region length. The assessment results show that the sealing performance can be enhanced without significant deterioration of the fatigue durability in a certain range of the half-bead width. In the other cases the improvement of sealing performance is accompanied by the loss of the fatigue durability. Among three parameters, the bead width has the strongest influence.

Relationship between Film Density and Electrical Properties on D.C. Magnetron Reactive Sputtered Sn-doped ${In_2}{O_3}$Films (D.C. 마그네트론 반응성 스퍼터링법에 의한 Sn-doped ${In_2}{O_3}$ 박막의 밀도와 전기적 특성과의 관계)

  • 이정일;최시경
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.7
    • /
    • pp.686-692
    • /
    • 2000
  • Tin-doped In2O3 (ITO) films were fabricated using a d.c. magnetron reactive sputteirng of a In-10 wt% Sn alloy target in an Ar and O2 gas mixture. To understand the behavior of the carrier mobility in ITO films with O2 partial pressure, the resistivity, carrier concentration and mobility, film density, and intrinsic stress in the films were measured with O2 partial pressure. It was found experimentally that the carrier mobility increased rapidly as the film density increased. In the ITO film with the density close to theoretical one, the mean free path was the same as the columnar diameter. This indicated that the mobility in ITO films was strongly influenced by the crystall size. However, in the case where the film density was smaller than a theoretical density, the mean free paths were also smaller the columnar diameter. It was analyzed that the electron scattering at pores and holes within the crystalline was the major obstacle for electron conduction in ITO films. The measurement of intrinsic stress in ITO films also made it clear that the density of ITO films was controlled by the bombardment of oxygen neutrals on the growing film.

  • PDF

A Study on the Reclamation of the Furan Sand by the Fluidized Bed (유동층을 이용한 주물사의 재생에 관한 연구)

  • Baek, Ko-Kil;Choi, Yang-Jin
    • Journal of Korea Foundry Society
    • /
    • v.12 no.6
    • /
    • pp.471-479
    • /
    • 1992
  • For the last 2 decades, the bonding materials for the foundry sand and the foundry equipments with high performance have been developed and employed in the foundry shops. In those periods, the furan resins hardened in higher temperature have been replaced with the self-hardened ones in the room temperature. Simultaneously the various reclamation methods of the self-hardened furan resin sand have been developed in order to get the clean working environments, the reduction of solid wastes and the lower of production cost in the foundry. In this experimental study, the combustion reclamation method using the fluidized bed among the various methods was studied in order to reduce the L.O.I. and /or $N_2$ gas due to the deposition of the furan resins and the hardeners. Comparing the results of this experimental combustion reclamation method with those of the employed pneumatic method, the Surface Stability Index of the specimen made by combustion method is 30% higher than that of the latter one and L.O.I. decreases about 30%. The reclamation temperature of 650$^{\circ}C$ in this experimental fluidized bed would be recommended in the viewpoints of the reclamation period, the fuel consumption and the residual quantity of the furan resin. The formula determining the minimum fluidizing velocities according to the temperatures in the fluidized bed has been obtained.

  • PDF

Gas Chromatography Residue Analysis of Bifenthrin in Pears Treated with 2% Wettable Powder

  • Choi, Jeong-Heui;Liu, Xue;Kim, Hee-Kwon;Shim, Jae-Han
    • Toxicological Research
    • /
    • v.25 no.1
    • /
    • pp.41-45
    • /
    • 2009
  • This study was conducted to monitor the level of bifenthrin residues in pear sprayed with 2% bifenthrin wettable powder (WP) at the recommended rate at four different schedules prior to harvest. The target analyte was extracted with acetone, partitioned into dichloromethane, and then purified by florisil chromatographic column. The residue determination was performed on a DB-5 capillary column using GC with electron capture detector (ECD). Linearity of this method was quite good ($r^2$ = 0.9951) in the concentration ranged from 0.2 mg/kg to 10 mg/kg. Recovery test was carried out at two concentration levels, 0.2 mg/kg and 1.0 mg/kg, in three replicates, and their rates were from 82.9% to 107.2%. No quantitative bifenthrin was detected in pear of all kinds of treatments including the treatment sprayed 4 times until 7 days before harvest. This sensitive and selective method can be used to monitor the trace residual amounts of bifenthrin in pear in a quite low concentration level.