저압 수용가 설비에서 누전차단기와 서지방호장치 사이의 보호협조 (Protection coordination between residual current device and surge protective devices in low-voltage consumer's installations)

  • 이복희;김회구;박희열;안창환
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.75-81
    • /
    • 2013
  • In this paper, protection coordination between residual current devices and surge protective devices in low-voltage consumer's distribution systems are presented. In the case that a surge protrctive device(SPD) is located on the load side of an residual current device(RCD), when the surge is injected from the source side of the RCD, most of injected surge currents are split into the RCD and the protection coordination between the SPD and RCD is improper, three of 6 specimens experience unintended operation due to test impulse currents. Also when the surges is injected from the load side, a lot of the surge currents is split into the SPD, but a half of test specimens causes nuisance trip. Coordination between SPD and RCD is not valid. When installing SPD, it is important to select SPD after due consideration of the protection voltage level of metal oxide varistor embedded in RCD. It is expected that the results obtained from this work could be useful to improve the protection effects of SPD in low-voltage distribution systems.

DC 전류검출기의 감도 개선을 위한 새로운 자기변조 (A New Magnatic Modulation for Improving Sensitivity of DC Current Sensor)

  • 김한성;이환
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.268-277
    • /
    • 1994
  • Current sensor using Hall device is an instrument of detecting a current by Hall effect. The existing current sensor is ordinarily worked by concentrating electromagnetism produced around the conducting wire turned iron core. The tiny curren, however, could not be accurately detected by the instrument owing to influence of residual magnetism exisisting in iron core, and the result of detecting is also somewhat on the large side. kAccordingly, We fabricated a new type of instrument minimizing the influence of residual magnetism existing in iron core and detected the tiny DC current accurately by taking advantage of magnetic modulation. The range of measuring DC current is 0[mA]-100[mA] and the maxiumm Linerity tolleance by the result of detecting current, can be reduced less than 3 percent.

  • PDF

전력용 반도체 소자를 적용한 하이브리드 초전도 한류기 동작 신뢰도 향상 (Reliability Enhancement of Hybrid Superconducting Fault Current Limiter adopting Power Electric Device)

  • 심정욱;박권배;임성우;김혜림;이방욱;오일성;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.57-61
    • /
    • 2007
  • The current limiting characteristics of hybrid SFCL with additional power electronic devices was investigated in order to improve operation reliabilities. The hybrid SFCL developed consists of a superconducting trigger (S/T) part, a fast switch (F/S) module and a current limiting (C/L) part. Although hybrid SFCL had shown a excellent current limiting characteristics, this device was rather vulnerable to the residual arc currents which could exist during fast switch operation. This undesirable arc should be extinguished as quickly as possible in order to implement perfect fault current commutation. So, in order to eliminate the residual arcs between fast switch contacts, the power electronic devices (IGBT or GTO) were connected in series between the S/T part and the interrupter of the F/S module. According to the fault tests conducting with an input voltage of $270\;V_{rms}$ and a fault current of $5\;kA_{rms}$, The power electronic devices could perfectly remove the arc generated between the contacts of the interrupter within 4 ms after the fault occurred. From the test analysis, it was confirmed that the hybrid SFCL could enhance the operation reliability by adopting additional power electronic devices.

서지전류에 의한 누전차단기의 의도하지 않은 트립에 대한 신뢰성 (Reliability on the Unintended Trips of Residual Current Operated Circuit Breakers due to Surge Currents)

  • 이복희;김상현;김유하
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.79-84
    • /
    • 2012
  • As the huge economical loss and function paralysis of information technology-based systems can be caused by the misoperation of residual current devices(RCDs) due to surge voltages and currents, RCDs shall not operate by surge currents. In this paper, in order to evaluate the reliability of residual current operated circuit-breakers with integral overcurrent protection for household and similar uses((RCBOs) stressed by surges, the unintended trip characteristics of RCBOs under surge currents were experimentally investigated using the combination wave generator. Seven different types of single-phase RCBOs being present on the domestic market were investigated according to KS C IEC 61009-1 standard. As a result, all kinds of specimens were satisfied the requirements for 0.5 [${\mu}s$]/100[kHz] ring wave impulse currents. Most of specimens stressed by the 8/20[${\mu}s$] impulse current tripped at least one or more, and some of them were broken down during consecutive tests. It was found that only one type of specimens meets the L-N mode immunity to the combination wave of 1.2/50[${\mu}s$] impulse voltage and 8/20[${\mu}s$] impulse current.

저항성 누설전류(Igr) 검출 콘센트의 개발 및 안전성 평가 (Development and Safety Estimation of Resistive Leakage Current(Igr) of Detection Outlet)

  • 김창성;한송엽;최충석
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.221-226
    • /
    • 2009
  • In this paper, we analyzed form of flowing leakage current in electrical installation. Leakage current ($I_g$) is consisted of resistive leakage current($I_{gr}$), capacitive leakage current($I_{gc}$), and inductive leakage current($I_{gl}$). Resistive leakage current($I_{gr}$) is big occasion than capacitive leakage current($I_{gc}$) in system, Residual Current Protective Device(RCD) detects correctly leakage current. But,$I_{gc}$ is big occasion than $I_{gr}$, RCD is malfunctioned It is resistance to lead to electric fire in electrical device. We manufactured outlet that resistive leakage current detecting circuit is had. Manufactured outlet displayed performance exactly in leakage current of 5 mA Therefore, this product estimates that contribute on electric fire courtesy call.

고정밀 전류센서를 이용한 RCD 보조트립 장치 개발 (Development of RCD Auxiliary Trip Device by using High Precision Current Sensor)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1532-1537
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution lines, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore this paper is confirmed the unreliability of the existing RCD by electrical faults simulation and is proposed a auxiliary trip device of RCD by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution lines caused by overload or electric short circuit faults. The sensitive reed switch in the proposed ATD (auxiliary trip device) exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and then rapidly cuts off the existing RCD. The proposed auxiliary trip device of RCD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed ATD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

Full Wave Cockroft Walton Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.246-252
    • /
    • 2011
  • A high-voltage power supply has been built for activation of the brain via stimulation using a Full Wave Cockroft-Walton Circuit (FWCW). A resonant half-bridge inverter was applied (with half plus/half minus DC voltage) through a bidirectional power transistor to a magnetic stimulation device with the capability of producing a variety of pulse forms. The energy obtained from the previous stage runs the transformer and FW-CW, and the current pulse coming from the pulse-forming circuit is transmitted to a stimulation coil device. In addition, the residual energy in each circuit will again generate stimulation pulses through the transformer. In particular, the bidirectional device modifies the control mode of the stimulation coil to which the current that exceeds the rated current is applied, consequently controlling the output voltage as a constant current mode. Since a serial resonant half-bridge has less switching loss and is able to reduce parasitic capacitance, a device, which can simultaneously change the charging voltage of the energy-storage condenser and the pulse repetition rate, could be implemented. Image processing of the brain activity was implemented using a graphical user interface (GUI) through a data mining technique (data mining) after measuring the vital signs separated from the frequencies of EEG and ECG spectra obtained from the pulse stimulation using a 90S8535 chip (AMTEL Corporation).

교류 전압 구동에 의한 유기 발광 소자의 발광 특성 연구 (Light-Emission Characteristics of Organic Light-Emitting Diodes Driven by Alternating Current)

  • 권오태;김태완
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.625-629
    • /
    • 2016
  • Electrical and optical properties of the AC voltage driven organic light-emitting diodes were investigated by measuring the electroluminescence of the device. Device structure of ITO(170 nm)/TPD(40 nm)/Alq3(60 nm)/LiF(0.5 nm)/Al(100 nm) was manufactured using a thermal evaporation. Sinusoidal and square-type AC voltage was applied to the device using a function generator. Amplitude of the applied voltage was 9.0 V, and a frequency was varied from 50 Hz to 50 kHz. Electroluminescence out of the device was measured in a Si photodetector simultaneously with the applied voltage together. An intensity and a delayed residual luminescence from the device were depended on the frequency of the sinusoidal voltage. It is thought to be due to a contribution of the capacitive nature in the equivalent circuit of the device. An electron mobility was estimated using a time constant obtained from the luminescence of the device driven by the square-type AC voltage.

RCD와 SPD의 접속 위치에 따른 보호협조 (Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices)

  • 이복희;박희열;신건진;배관영;류춘형;이강희
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.100-106
    • /
    • 2013
  • In this paper, in order to analyze lightning impulse response characteristics in combined installations of SPDs and RCDs, surge protection coordination between SPDs and RCDs are experimentally investigated by using the combination wave generator. Six different types of single-phase residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs) being present on the domestic market are tested according to KS C IEC 61009-1 standard. As a result, when a class I SPD is located on the source side of an RCBO, all kinds of specimens are able to provide the proper coordination between the SPD and RCBOs without nuisance tripping, unintended operation or damage due to test impulse currents. However, in the case that the class II SPD is located on the load side of RCBOs, a lot of L-N mode injected currents is split into the RCBO, and a few RCBOs are damaged. Coordination between SPDs and RCDs is not valid and a role of SPDs is of no use. When combining SPDs with RCDs, it is necessary to select SPDs and RCDs in consideration of the protection voltage level of metal oxide varistor embedded in RCDs.

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.