• Title/Summary/Keyword: Residual Chloride

Search Result 121, Processing Time 0.026 seconds

A Study on Residual Amounts of Vinyl Chloride/Vinylidene Chloride in Poly(vinyl chloride)/Poly(vinylidene chloride) Food Packaging using Headspace GC/MS (헤드스페이스 GC/MS를 이용한 폴리염화비닐/폴리염화비닐리덴 식품 포장 중 염화비닐/염화비닐리덴 잔류량 연구)

  • Sung, Jun-Hyun;Kwak, In-Shin;Park, Sung-Kwan;Kim, Hyung-Il;Lim, Ho-Soo;Lee, Ju-Young;Byun, Mi-Yun;Kim, So-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.6-11
    • /
    • 2011
  • Vinyl chloride (VC) and vinylidene chloride (VDC), which may be present in poly(vinyl chloride) (PVC) and poly(vinylidene chloride) (PVDC) food packaging, were analyzed by using a headspace-gas chromatograph (GC)/mass spectrometer (MS) equipped with a PLOT Q column. 1-Chloropropane (1-CP) was used as an internal standard. The determinations of VC and VDC were carried out by monitoring the characteristic ions for each compound: m/z=61, 62, 64 and m/z=61, 96, 98, respectively. The method validated in this study can be suitable for the compliance test of EU regulation. Among 103 food packaging samples, VC and VDC were not detected, except in one PVDC food package. However, the detected level of VDC in the sample was below the EU regulatory specific limitation.

Residual Liquid Behavior Calculation for Vacuum Distillation of Multi-component Chloride System (다성분 염화물계 진공 증류의 잔류 액체 거동 계산)

  • Park, Byung Heung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.3
    • /
    • pp.179-189
    • /
    • 2014
  • Pyroprocessing has been developed for the purpose of resolving the current spent nuclear fuel management issue and enhancing the recycle of valuable resources. An electrolytic reduction of the pyroprocessing is a process to reduce oxides into metals using LiCl as an electrolyte and requires a post-treatment process due to the inclusion of residual salt in porous metal products. A vacuum distillation has been adopted for various molten salt systems and could be applied to the post-treatment process of the electrolytic reduction. The residual salt in the metal products includes LiCl, alkali chlorides, and alkaline earth chlorides. In this paper, vapor pressures of chlorides have been estimated and the composition changes on the residual liquid during the vacuum distillation process have been calculated. A model combining a material balance and vapor-liquid equilibrium relations has been proposed under a constant vapor discharging flow rate and liquid composition changes have been calculated using the vapor pressures with respect to a dimensionless time. The behaviors have been compared with temperature and molten salt composition changes to simulate the process condition variation. The distillation of the residual salt has been dominated by LiCl which is the main component of the salt and CsCl of which vapor pressure is higher than that of LiCl would be readily removed. RbCl exhibits similar vapor pressure with LiCl and maintains its composition. However, $SrCl_2$ and $BaCl_2$ of which vapor pressures are much lower than that of LiCl are concentrated with time and expected to be possibly precipitated during the distillation when the initial compositions are increased.

Study on the Development of Simultaneous Analytical Method for the Residual Organic Chloride Pesticides by Gas Chromatography (기체 크로마토그래피를 이용한 유기 염소계 잔류 농약 동시 분석 방법 개발에 관한 연구)

  • Kim, Woo-Seong;Lee, Bong-Hun;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.5 no.5
    • /
    • pp.561-567
    • /
    • 1996
  • A method for the simultaneous analysis of 31 residual organic chloride pesticides was studied using gas chromatography. Prepared analytical samples were injected to gas chromatography (HP 5890 Series II plus) on the Ultra-2 column with ECD. The packing materials for column were changed as the following reagents ; florisil and alumina N, The residual solution was loaded to column and was elected pith erection solvents ; ether : benzene (2 : 8) solution, hexane : benzene (1 : 1) solution, dichloromethane, acetone, and methanol. The analytical results showed that 6 kinds of organic chlorides were not detected when florisil (first condition) was used as the column packing material. The nondetected 6 kinds of organic chlorides in the first analytical condition were detected and the recoveries of thrin-pesticides were increased, in particular, captan and captafol, but the recoveries of benzene hexachloride compounds were decreased when dichloromethane and methanol were added as elution solvents (pac'king material was florisil as in the first condition). The recoveries of dichlornuanid, chlorofenvinfos, folpet, and dicofol were increased and that of aldrin was increased, but those of captan and captafol were not good when alumina N was used as the packing material. To detect simultaneously thrin-pesticides, captan, and captafol, florisil and alumina N were used as the packing materials. The elution result showed that captan and captafol were not detected. This was because the column was activated insufficiently. The analytical method was the best (31 kinds of organic chlorides in the residual pesticides were detected sharply and showed high sensitivity) when the column (packing materials were florisil and alumina N: together) was fuliy activated and the impurities were removed using various elution solvents.

  • PDF

Determination of ethylene glycol in alkali wastewater by gas chromatography/mass spectrometry (GC/MS를 이용한 알칼리 폐수 중 ethylene glycol 정량)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.527-531
    • /
    • 2004
  • Treatment with aqueous sodium hydroxide solution plays an important role to impart certain desirable properties - feel and luster on the surface of polyester fiber. In this process alkali wastewater contains disodium terephthalate, ethylene glycol (EG) and residual sodium hydroxide. In this paper we report a new method containing the pretreatments of derivatization with benzoyl chloride and solvent extraction using pentane. The calibration curve of EG determined by GC/MS-SIM shows a good linearity in the range of 0.1 to $25{\mu}g/mL$ having the standard deviation of ${\leq}8.7%$. The recovery and the detection limit of this method are 91.9-93.7% and $0.05{\mu}g/mL$ respectively.

Biosequestration, Transformation, and Volatilization of Mercury by Lysinibacillus fusiformis Isolated from Industrial Effluent

  • Gupta, Saurabh;Goyal, Richa;Nirwan, Jashan;Cameotra, Swaranjit Singh;Tejoprakash, Nagaraja
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.5
    • /
    • pp.684-689
    • /
    • 2012
  • In the present study, an efficient mercury-tolerant bacterial strain (RS-5) was isolated from heavy-metalcontaminated industrial effluent. Under shake flask conditions, 97% of the supplemented mercuric chloride was sequestered by the biomass of RS-5 grown in a tryptone soy broth. The sequestered mercuric ions were transformed inside the bacterial cells, as an XRD analysis of the biomass confirmed the formation of mercurous chloride, which is only feasible following the reaction of the elemental mercury and the residual mercuric chloride present within the cells. Besides the sequestration and intracellular transformation, a significant fraction of the mercury (63%) was also volatilized. The 16S rRNA gene sequence of RS-5 revealed its phylogenetic relationship with the family Bacillaceae, and a 98% homology with Lysinibacillus fusiformis, a Gram-positive bacterium with swollen sporangia. This is the first observation of the sequestration and volatilization of mercuric ions by Lysinibacillus sp.

Cause of Corrosion and Evaluation of Material Corrosion Resistance on Underground Heat Transport Facilities Connected to Manhole (맨홀과 연결된 지하 열수송설비의 부식 원인 및 재질 내식성 평가)

  • Song, M.J.;Choi, G.;Kim, W.C.;Lee, S.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.4
    • /
    • pp.193-202
    • /
    • 2022
  • Manholes and underground spaces are installed to manage the buried heat transport pipes of the district heating system, and the corrosion damage of the equipment placed in this space often occurs. The purpose of this work is to identify locations with a high risk of corrosion damage in the air vent and to establish preventive measures based on precise analysis via sampling of heat transport pipes and air vents that have been used for about 30 years. The residual thickness of the air vent decreased significantly by reaching ~1.1 mm in thickness, and locations of 60~70 mm away from a transport pipe were the most vulnerable to corrosion. The energy dispersive X-ray spectroscopy (EDS) analysis was performed in the corroded oxides, and it was found that chloride ion was contained in the corrosion products. Anodic polarization tests were carried out on the air vent materials (SPPS250, SS304) with varying the amounts of chloride ions at two different temperatures (RT, 80℃). The higher concentration of chloride ions and temperature are, the lower corrosion resistances of both alloys are.

Development of the testing method for vinyl chloride monomer (VCM) in polyvinyl chloride(PVC) samples (PVC 제품에서의 염화비닐 단량체 정량분석 방법에 관한 연구)

  • Kweon, Deok-Jun;Choi, Ki-In;Eom, Hui-Jeong;Lee, Jae-In;Choi, Zel-Ho
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.395-401
    • /
    • 2012
  • This study presents a method for the quantitative analysis of residual vinyl chloride monomer (VCM) in PVC products. In elution solvent, the extraction efficiency was similar by ethanol, THF, and acetone, but using n-hexane, it indicated relatively low extraction efficiency. Measuring VCM in the pulverized PVC samples, it showed reasonable results in both the direct injection method and headspace method with GC/MS. Regarding analysis of VCM in the intermediate sponge samples, five laboratories showed good results, and from the results, it was considered that VCM quantitative method in this study was reliable.

The Effects of Residual Al on Plankton Community after Dissolved Air Flotation (DAF) Application (가압부상 후 잔류 응집제가 플랑크톤 군집에 미치는 영향)

  • Kim, Ho-Sub;Gong, Dong-Su;Lee, Hyung-Jin;Shin, Jong-Kyu;Kang, Tae-Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.837-842
    • /
    • 2007
  • This study was conducted to test the effect of residual Al on plankton community after dissolved air flotation (DAF) application. Growth rate of phytoplankton after DAF application ($0.37day^{-1}$) was about 2 times lower than that before DAF application ($0.70day^{-1}$). Under the condition of addition of nitrogen and phosphorus without light, growth rate phytoplankton in treatment without residual Al increased in difference with showing the negative growth rate in treatment with residual Al. Under the condition of light without addition of nutrient, growth rate of phytoplankton was no noticeable difference between the before and after DAF application. The relatively high settling rate (0.47 m/day) was observed in treatment after DAF application. Although the abundance of rotifer decreased, the abundance of copepod and cladoceran such as Daphnia galeata, Diaphanosoma sp. and Bosmina longirostris with relative higher grazing was no noticeable difference between the before and after DAF application. In the treatments before and after DAF application with zooplankton, growth rate of phytoplankton was $0.41{\pm}0.08day^{-1}$, $0.20{\pm}0.03day^{-1}$, respectively. This difference was in treatment after DAF application similar with those in treatments before and after DAF application without zooplankton. Those indicate that the filter-feeding effect of zooplankton on phytoplankton community may be not changed by residual Al after the DAF application. These results suggest that residual Al after DAF application be to improve water quality by inhibition of growth rate as well as increasing settling rate of phytoplankton.

Effects of Ni Concentration on Residual Stress in Electrodeposited Ni Thin Film for 63Ni Sealed Source (63Ni 밀봉선원용 Ni 전기도금 박막에서 Ni 농도가 잔류응력에 미치는 영향)

  • Yoon, Pilgeun;Park, Deok-Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • Chloride plating solution was fabricated by dissolving metal Ni powders in a mixed solution with HCl and de-ionized water. Effects of $Ni^{2+}$ and saccharin concentrations in the plating baths on current efficiency, residual stress, surface morphology and microstructure of Ni films were studied. In the case of $0.2M\;Ni^{2+}$ concentration, current efficiency was decreased to about 65 % with increasing saccharin concentration, but, in the case of $0.7M\;Ni^{2+}$ concentration, it was shown more than 90 % with the increase of saccharin concentration. Residual stress of Ni thin film was appeared to be about 400 MPa up to 0.0244 M saccharin concentration at the $0.2M\;Ni^{2+}$ concentration and surface morphology with severe cracks was observed in the range of 0.0487~0.0975 M saccharin concentration. Residual stress of Ni thin films was measured to be about 750 MPa without saccharin addition and 114~148 MPa at the range of 0.0097~0.0975 M saccharin concentration for the $0.7M\;Ni^{2+}$ concentration. Relatively low residual stress values (114~148 MPa) of the Ni films at the range of 0.0097~0.0975 M saccharin concentration may be resulted from codeposition of S from saccharin. Ni films at $0.7M\;Ni^{2+}$ concentration showed smooth surface morphology and were independent of saccharin concentration. Ni films at $0.7M\;Ni^{2+}$ concentration consist of FCC(111), FCC(200), FCC(220) and FCC(311) peaks and the intensities of FCC(111) and FCC(200) peaks increased with increasing saccharin concentration. Also, the average grain size decreased with increasing saccharin concentration from about 30 nm to about 15 nm.

Development of Simultaneous Analytical Method for Various Residual Pesticides Using GC-ECD (GC-ECD를 이용한 잔류 농약 다성분 동시 분석법 개발)

  • 김우성;손영욱;정지윤;안경아;홍무기;임무혁;이홍재;이봉헌;박흥재
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.88-92
    • /
    • 2001
  • The simultaneous analytical method for 37 residual pesticides was developed by a gas chromatography with $^{63}$ Ni electron capture detector. Pesticides added in soybean sample were extracted with 70% acetone in water and methylene chloride in oder, and then cleaned up via open-column apparatus packed with florisil and alumina N. The Ultra-2 fused capillary column was used to separate the products. The resolution between the last isomeric peak of cypermethrin (56.398 min) and the first isomeric peak of flucythrinate (56.421 min) was not satisfactory and the last isomeric peak of fenvalerate(58.783 min) and the first isomeric peak of fluvalinate(58.835 min) was overlapped. Except for $\alpha$-BHC, dichlofluanid, captan, and captafol, most recoveries were showed over 70%.

  • PDF