• Title/Summary/Keyword: Residential water

Search Result 463, Processing Time 0.029 seconds

A Study on the Environmentally-friendly Design Techniques Extract and Applying Modern of Traditional Residential Area - The Case of Dokrakdang in Kyungbuk Province - (전통주거공간의 환경친화적 설계기법 추출 및 현대적 적용 - 경상북도 독락당을 사례로 -)

  • Heo, Jun;Song, Byeong Hwa
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.2
    • /
    • pp.63-72
    • /
    • 2011
  • The aim of this study, a traditional residential area in the environmentally friendly design techniques to identify the techniques and principles that have been carried out to reestablish the principles. To do this, through literature review environmental performance is reflected in the traditional residential area side of resources conservation, locational aspects, spatial configuration, and how cases were selected looking for ways to apply modern. Are examples of upper class housing in the Chosen Dynasty Period period construction relatively well-preserved round and a good building with a clear housing Dokrakdang year were selected. Locational aspects of the terrain with minimal changes to the building and construction techniques were entirely in terms of environmental conservation and environmental temperature was adjusted to regulate the room temperature technique could be seen. In terms of cycling in natural materials were recycled. and water make used of positive through water cycling technique & water control. In addition, the importance of landscape views overlooking the landscape from inside to outside through the regulation of the various internal and external space technique was used to attract and expand. Traditionality in the pursuit of modern space, simply cut off because of tradition rather than to restore or recover the organizing principle inherent in the traditional space, and extraction of the contemporary social, cultural and environmental understanding of space is acceptable in basis. Environmentally-friendly design techniques in a traditional residential area for a long time to be developed by the experience of its application of modern environmental and energy problems and pleasant environment to the creation of human life and are subject to significant swings in that.

Environmental Impact Assessments along with Construction of Residential and Commercial Complex (주거단지 건설이 하천에 미치는 생태영향평가)

  • An, Kwang-Guk;Han, Jeong-Ho;Lee, Jae Hoon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.631-648
    • /
    • 2012
  • The integrative ecological approaches of chemical assessments, physical habitat modelling, and multi-metric biological health modelling were applied to Gwanpyeong Stream within Gap-Stream watersheds to evaluate environmental impacts on the constructions of residential and commercial complex. For the analysis, the surveys conducted from 45 sites of reference streams within the Gap-Stream watershed and 3 regular sites during 2009 - 2010. Physical habitat health, based on the habitat model of Qualitative Habitat Evaluation Index(QHEI) declined from the headwaters(good - fair condition) to the downstream(poor condition). Chemical water quality, based turbidity and electric conductivity(EC), was degraded toward to the downstream, and especially showed abrupt increases, compared to the values of control streams(CS). Also, concentrations of chlorophyll-a in the downstreams were greater compared to the control stream(CS), indicating an eutrophication. Biological health conditions, based on the Index of Biological Integrity(IBI) using fish assemblages, averaged 19.3 which is judged as a fair condition by the biological criteria of the Ministry of Environment, Korea. The comparisons of model metric values in sensitive species and riffle-benthic species on the Maximum Species Richness Line(MSRL) of 45 reference streams indicated a massive disturbances in all sampling locations. Also, tolerance guild and trophic guild analyses suggest that dominances of tolerant species and omnivores were evident, indicating a biological degradation by habitat disturbances and organic matter pollutions. There was no distinct longitudinal variations of IBI model values from the headwater to the downstream in spite of slight chemical and habitat health gradients among the sampling sites. Overall, integrative ecological health(IEH) scores, based on the chemical, physical, and biological parameters, were low compared to the 45 reference streams due to physical and chemical disturbances of massive constructions of the residential and commercial complex. This stream, thus showed a tendency of typical urban streams which are disturbed in the chemical water quality, habitat structures, and biological integrity. Effective stream management plans and restoration strategies are required in this urban stream for improving integrative stream health.

Characteristics of Bacteria in the Living Room and Bathroom of a Residential Environment Using the Pyrosequencing Method (파이로시퀀싱 분석법을 이용한 주거 환경 중 거실과 화장실의 세균 특성)

  • Lee, Siwon;Chung, Hyen-Mi;Park, Eung-Roh
    • Microbiology and Biotechnology Letters
    • /
    • v.44 no.1
    • /
    • pp.84-88
    • /
    • 2016
  • In this study, bacterial diversity in the living room and bathroom of a residential environment was analyzed using the pyrosequencing method. There was no difference in the diversity index of bacteria between the 2 rooms; however, differences were noted in the composition of bacteria. The classes ${\beta}$-Proteobacteria and ${\delta}$-Proteobacteria were found in the bathroom at higher abundances than in the living room. The phyla Acidobacteria, Chlorobi, Chloroflexi, Fusobacteria, Nitrospirae, and Planctomycetes were found in the bathroom, but not in the living room, indicating a broader range of bacteria. However, the living room showed a more diverse range of bacterial genera than the bathroom did. In both the living room and the bathroom, the genus Methylobacterium was dominant.

Long-Term Trend of Groundwater Recharge According to Urbanization (도시화에 의한 장기 지하수 함양량 변화)

  • Lee, Seung-Hyun;Bae, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.779-785
    • /
    • 2010
  • To solve a problem of water supply on urban areas, groundwater recharge has to be assessed not only for evaluating the possibility of groundwater development but also for identifying a sustainable aquifer system for water resource development. The assessment of groundwater recharge has been challenged since the land use has been changed constantly. In this study, the groundwater recharge and its ratio were assessed from 1961 to 2007 in Su-yeong-gu, Busan, South Korea by analyzing precipitation, land use, and soil characteristics. For land use analysis, the urbanization change was considered. The land use areas for the residential, agricultural, forest, pasture, bare soil, and water in 1975 occupy 18.6 %, 30.0%, 48.8%, 0.1%, 2.0%, and 0.5% of total area, respectively. The land use ratios were sharply changed from 1980 to 1985; the agricultural area was decreased to 18.3%, and the residential area was increased to 15.0%. From 1995 to 2000, the agricultural area was decreased to 5.5%, and the residential area was increased to 5.4%. The annual averages of precipitation, groundwater recharge, and its ratio were 1509.3 mm, 216.0 mm, and 14.3% respectively. The largest amount of the groundwater recharge showed in 1970 as 408.9 mm, comparing to 2138.1 mm of annual rainfall. Also, the greatest ratio of the groundwater recharge was 19.8% in 1984 with 1492.6 mm of annual rainfall. The lowest amount and ratio of the groundwater recharge were 71.9 mm and 8.0% in 1988, relative to 901.5 mm of annual precipitation. As a result, it is concluded that rainfall has increased, whereas groundwater recharge has decreased between 1961 and 2007.

Plan of Nature-friendly Residential Space (자연과 교우하는 주거공간 계획)

  • Kim, Bong-Soon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.32-35
    • /
    • 2008
  • If human beings could make friends with nature, it would be a truly wellbeing. This project has selected the design concept under the supposition that human beings and the nature become friends. This residential house, which is consisted of one ground floor and two underground floors, is confronting the mountains that surround the residential complex. Residents can enjoy viewing the mountains from the living room. The garden is created by using this given environment in maximum. The walls are made up with rocks, and a small pond is formed with water from the mountain, presenting another attractive sight. Through the connection rather than the break between mountain and garden, living room and garden, and again garden and mountain, the dialogue with nature was attempted. The water of the pond in the garden flows down along the walls and creates another water space at the gate area of the house. Passing through the entrance, there are a living room, a kitchen, a bedroom for spouses, a common bathroom, and a library on the ground floor. On the second floor, there are two rooms, a bathroom, and a mini living room. The platform of living room on the 1st floor is lowered to produce the comfortable living room with the hearth. From the view of living room, the garden with full feeling of nature can give a good emotional rest for modem people who want the mental relaxation. The marble stones are used as its material to present rich texture and sophisticated image presentation. The hearth in the living room is harmonized with high-tech electronic home appliances and surrounding accessories. On the kitchen, the high-glossy materials are used to express the external appearance neatly and the depository function is more improved for housewives.

  • PDF

SOUTH KOREA′S WATER RESOURCES POLICY TOWARD THE 21ST CENTURY: CONFLICTING VIEWS

  • Choi, Yearn-Hong
    • Water Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Issues and problems in formulating South Korea's water resources policy are discussed in terms of water quantity and quality. South Korean needs both water conservation and water supply capability for the growing population and economic activities. The government has attempted to build more large-scale dams to store and supply water for residential, farming and industrial uses, but the environmentalists who emphasize conservation and environmental protection oppose the government. The environmentalists are popular among the general public. Water quality has been deteriorating from point- ad non-point sources. urban and farm runoffs are serious pollutants. All want by preserve water quality. There is no dispute on this matter between the government and the environmentalists. Money is hard to come by to preserve water quality. Economic and financial crises and no self-sufficient local governments' revenue structure are pessimistic. Basic survey on water resources, hydrology and hydraulic is badly needed for the future water resources planning.

  • PDF

Self-sustainable Operation of a 1kW class SOFC System (1kW급 고체산화물 연료전지 발전시스템 자열운전)

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 single cells and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen after pre-treatment process, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water.

  • PDF

Performance optimization of 1 kW class residential fuel processor (1 kW급 가정용 연료개질기 성능 최적화)

  • Jung, Un-Ho;Koo, Kee-Young;Yoon, Wang-Lai
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.731-734
    • /
    • 2009
  • KIER has been developed a compact and highly efficient fuel processor which is one of the key component of the residential PEM fuel cells system. The fuel processor uses methane steam reforming to convert natural gas to a mixture of water, hydrogen, carbon dioxide, carbon monoxide and unreacted methane. Then carbon monoxide is converted to carbon dioxide in water-gas-shift reactor and preferential oxidation reactor. A start-up time of the fuel processor is about 1h and CO concentration among the final product is maintained less than 5 vol. ppm. To achieve high thermal efficiency of 80% on a LHV basis, an optimal thermal network was designed. Internal heat exchange of the fuel processor is so efficient that the temperature of the reformed gas and the flue gas at the exit of the fuel processor remains less than $100^{\circ}C$. A compact design considering a mixing and distribution of the feed was applied to reduce the reactor volume. The current volume of the fuel processor is 17L with insulation.

  • PDF

The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation (발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구)

  • Yun, Chang-Yeon;Jeong, Jeong-Ho;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.

Analysis of pollutant build-up model applied to various urban landuse

  • Choi, Jiyeon;Na, Eunhye;Ryu, Jichul;Kim, Jinsun;Kim, Hongtae;Shin, Dongsuk
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.13-17
    • /
    • 2019
  • This study was conducted to analyse the application of pollutant build-up model on various urban landuses and to characterize pollutant build-up on urban areas as a source of stormwater runoff pollution. The monitored data from impervious surfaces in urban areas such as commercial (8 sites), industrial (10 sites), road (8 sites), residential (10 sites), recreational (5 sites) from 2008 to 2016 were used for the analysis of pollutant build-up model. Based on the results, the average runoff coefficients vary from 0.35 to 0.61. In all landuses except recreational landuse, the runoff coefficient is 0.5 or more, which is the highest in the commercial area. Commercial landuse where pollutants occur at the highest EMC in all landuse, and it is considered that NPS management is necessary compared with other landuses. The maximum build-up load for organic matter (BOD) was highest in the commercial area ($4.59g/m^2$), and for particular matter (TSS) in the road area ($5.90g/m^2$) while for nutrient (TN and TP) in the residential area ($0.40g/m^2$, $0.14g/m^2$). The rate constants ranged from 0.1 to 1.3 1/day depending on landuse and pollutant parameters, which means that pollutant accumulation occurs between 1 and 10 days during dry day. It is clear that these build-up curves can generally be classified based on landuse. Antecedent dry day (ADD) is a suitable and reasonable variable for developing pollutant build-up functions. The pollutant build-up curves for different landuse shows that these build-up curves can be generally categorized based on landuse.