• Title/Summary/Keyword: Residential station

Search Result 103, Processing Time 0.033 seconds

A Study on the Commercialization Characteristics of 2nd Class Residential District in Inner-city Railway Station Area (역세권 제2종 일반주거지역 상업화 확산과 특성 분석)

  • Yoon, Yong-Suk;Yang, Woo-Hyun
    • Journal of the Korean housing association
    • /
    • v.23 no.2
    • /
    • pp.25-36
    • /
    • 2012
  • The purpose of this study is to find out the commercialization characteristics of 2nd class residential district in innercity railway station area as basic research to protect urban residential area against the pressure of commercialization. Through the research that are based on literature, field survey and urban planning map, it analysed the commercialization characteristic of selected three sites under similar urban condition; to be a nearby subway station and to be a famous commercial street in site, etc. The consequences of this study are summarized as follows; First it finds the commercialized lots in all blocks that adjoin blocks of upper class zoning. Second it is in inverse proportion between the commercialization of lots and the distance from subway station to residential block. Third, the corner lot of a block and the access road directly connected collector road are very important factors to spread commercialization to residential area. Finally, it finds the difference of the commercialization degree of 2nd class residential zone according to arrange main commercial street and the 2nd class residential block; vertical arrangement and horizontal arrangement.

A study on the commercialization cause of 2nd class residential area in urban center (도시거점내 제2종 일반주거지역 상업화 확산과 원인 분석)

  • Yoon, Yong-Suk;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.147-152
    • /
    • 2011
  • The purpose of this study is to find out the commercialization cause of 2nd class residential area in urban center as basic research to protect urban residential area against the pressure of commercialization. Through the research that are based on literature, field survey and urban planning map, it analysed the commercialization cause of selected two sites under similar urban condition ; to be a nearby subway station and to be a famous commercial street in site, etc. The consequences of this study are summarized as follows ; First the distance between subway station and residential block and residential commercialization are in inverse proportion each other. Second, the corner lot of a block and the access street directly connected collector street are very important factors to spread commercialization to residential area. Finally, nevertheless first and second results, there is square zone which is very high rate of commercialization within one regardless the distance between subway and residential block. the maximum range of square zone is assumed about 250 meter based on case study.

  • PDF

Characteristics of Air Pollutant Concentrations Near Major Roadways in Daegu (대구지역 주요 도로변 대기오염물질의 농도 특성)

  • Jo, Wan-Kuen;Choi, Sung-Rak
    • Journal of Environmental Science International
    • /
    • v.15 no.8
    • /
    • pp.737-744
    • /
    • 2006
  • Present study was designed to characterize the concentrations of major roadside air pollutants in Daegu and to compare with those of Seoul and Busan. Evaluated were the exceedance frequence of mean concentrations of target compounds(CO, NO$_2$, O$_3$, PM$_{10}$, SO$_2$) and the relationship for time variation. Two air pollution monitoring stations(one roadside station and one residential station) in Daegu were selected for this study. In addition, one roadside monitoring station from each of Seoul and Busan was chosen for the comparison of Daegu monitoring stations. The data analyzed in the current study were collected from 1998 to 2000 by Daegu Regional Environmental Management Office. The roadside concentrations of NO2 and PM to and the exceedance frequency of ambient air standard levels in Daegu were higher than those of Seoul and Busan. Except 03, the roadside concentrations of all target compounds showed following three distinguished patterns; first, possibly due to increased traffic density, the concentrations increased from 0500 to 0900(LST), second, the concentrations decreased from 0900 to 1700(LST) possibly due to the increased wind velocity and decreased traffic density, and finally, increased traffic density, the concentrations increased again from 1700 to 2100(LST). An implication was that major air pollution sources shifted from residential area to road-area during rush hours.

A Study on the Changes the Urban Space at Station Influenced Areas by the Open of Incheon Urban Railroad Line 1 (인천광역시 도시철도 1호선 개통에 따른 역세권 도시공간 변화 연구)

  • Ahn, Jung Geun;Park, Man Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.141-148
    • /
    • 2011
  • City of Incheon opened rapid transit(urban railroad line 1) in 1999 in order to relieve traffic congestion on major arterials. This research analyzed urban space changes of each station influenced area by examining the changes of residents, industrial employees, and floor area ratios before and after the open of Incheon urban railroad line 1. Analysis of variance was applied to change of station influence area. This research found out that the types of central business and agricultural station influence area had been changed significantly after the open of urban railroad. However, the residential, semi-residential, and suburban type of station influence area had not been changed after the open of urban railroad. Thus, it is necessary to provide diverse facilities for inducing residents and employees to the station influence area of residential and semi-residential. Furthermore, the suburban type of station influence area which is difficult to develop naturally by the law of Green Belt is needed to develop station influence area simultaneously with the construction of a station building.

Evaluation and Complement of the Representativeness of Air Quality Monitoring Stations Using Passive Air Samplers (수동측정기에 의한 대기오염 자동측정망의 지역대표성 조사 및 보완방완에 대한 기초연구)

  • 우정현;김선태;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.415-426
    • /
    • 1997
  • Some arguments have been about over the representativeness of government-run air quality monitoring stations among scholars and non-governmental organizations (NGOs). However, it is not a simple problem to move monitoring stations because of continuity of data and high cost. So it is necessary to complement the monitoring data if it do not represent the ambient air quality properly. The purpose of this study was to evaluate the representativeness of some monitoring stations using passive $NO_2$ samplers and to find a complementary method from linear regression. Two stations were chosen for the evaluation: Shinlim Station was one of the most controversial stations in Seoul and Banpo Station had the best reputation. Air qualities were surveyed at seven points around each monitoring station with consideration of land use and distance. The ratios of the average $NO_2$ levels of the areas to these at the monitoring stations were 1.59 for Shinlim Station and 1.03 for Banpo Station. The differences between the average $NO_2$ levels and those at the monitoring stations were 10.75 ppb for Shilim Station and 0.34 ppb for Banpo Station. The correlation coefficients between the two levels were 0.7668 for Shinlim and 0.7662 for Banpo. The average coefficients of determination $(R^2)$ were 0.61 for Shinlim and 0.61 for Banpo. The Shinlim Station could not represent the air quality of Shinlim-Dong good because it is located in a green area at an outskirt of Shinlim-Dong. But the Banpo Station located in a central residential area of Banpo-Dong showed a fair representativeness. However, air quality turned out to be different with land use such as residential area, green area or road: the air quality data from a monitoring station located at a certain land use should not be interpreted as representing the air quality at any sites around the station. Equations to predict the average $NO_2$ levels of each area from the data from the monitoring stations were presented based on linear regression.

  • PDF

Investigating Wastewater Flow Characteristics - O and M Treatment Basins of A City - (처리분구별 하수발생 특성 조사 - A시 O, M 처리분구 -)

  • Hwang, Byung-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.348-356
    • /
    • 2005
  • Water quality sampling surveys and continuous measurement of flow were conducted to identify wastewater flow characteristics for representative catchment of O and M treatment basins in A city. For HS-1 station representing commercial area, wastewater flow rises in the beginning of office-working hours, moves up and down within narrow range, and lasts till office-leaving hour, and falls gradually reflecting worker's returning home. However, in HS-2 station representing residential area, wastewater flow has two peaks, which are before office-going hour and after office-leaving hour. In residential area, the flow rate of weekends is higher than that of weekdays because it reflects population, being not contributed to generate wastewater during the working hours of weekdays, stay home and produce wastewater for weekends period. To determine the priority for rehabilitation of sewer system, infiltration rate was computed by dividing infiltration flow by mean diameter and total length of sewer, and HS-1 station ranked the first.

A Study on Categorizing Subway Station Areas in Seoul by Rail Use Pattern (서울시 역세권의 유형화에 관한 연구 (요일별 시간대별 지하철 이용인구를 중심으로))

  • Sung, Hyun-Gon;Kim, Tae-Hyun
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.8 s.86
    • /
    • pp.19-29
    • /
    • 2005
  • The purpose of this study is to categorize subway station areas in Seoul by rail use characteristic. Most studies have categorized rail-oriented areas, based on land use patterns or/and urban spatial structure in Korea as well as the United States. However, the land use pattern of a subway station area tends to form by the real use of subway users since the latter plays an important role in forming the former. Therefore, the study is expected to contribute to the planning and policy of subway station areas in Seoul by analyzing characteristics of rail use. To achieve the purpose, the study uses a factor analysis for rail use, in terms of time of the day and day of the week. and then conducted a multidimensional scaling method to identify a relation of the real pattern to land use pattern. The results find that the Seoul subway station areas are categorized into residential, commercial and recreational, and office-centered ones. Furthermore, unlike the results of previous studies, the study identifies that many station areas have the mixed characteristics of economic activities. That is, they form more than a centered function such as residential and commercial, residential and office, commercial and office, residential, commercial and office. In addition, the study identifies that there is a close connection between rail use and land one. In short, identification of these mixed characteristics for subway station areas is expected to contribute to developing the planning and development method of TOD in Korea.

A Study on the Development of the Photo-electric Single Station Smoke Alarm of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력의 광전식 단독경보형감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • This is a case report of a photo-electric single station alarm for residential fire prevention. The detector was developed for the certification in Japanese market which is more than 100 times bigger than Korean market. A comparison and review for test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively is also conducted. The detector alarms with a buzzer and an indicating LED. Operating period and time in alarm, low battery and fire situation is stated. The electronics circuit part to reduce its current and the detector's characteristics are described. It is explained that the measured current and experimental result of the battery discharge can meet the 10 years operation.

Microenvironmental Exposures To Volatile Organic Compounds (미규모 환경에서의 휘발성 유기화합물 노출)

  • Jo, Wan-Kuen;Gang, Kwi-Wha;Woo, Hyung-Taek;Park, Jong-Kil
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.61-61
    • /
    • 1995
  • Volatile organic compounds(VOCs) are of concern for their potential chronic toxicity, their suspected role in the formation of smog, and their suspected role in destruction of stratospheric ozone. Present study evaluated the exposures to selected VOCs in three microenvironments: 2 chlorinated and 5 aromatic VOCs in the indoor and outdoor air, and 5 aromatic VOCs in the breathing zone air of gas-service station attendants. With permissible Quality Assurance and Quality Control performances VOC concentrations were measured 1) to be higher in indoor air than in outdoor air, 2) to be higher in two Taegu residential areas than in a residential area of Hayang, and 3) to be higher in the nighttime than in the daytime. Among five aromatics, Benzene and Toluene were two most highly measured VOCs in breathing zone air of service station attendants. Based on the sum of VOC concentrations, the VOC exposure during refueling was estimated to be about 10% of indoor and outdoor exposures. For Benzene only, the exposure during refueling was estimated to cause about 52% of indoor and outdoor exposure. The time used to calculate the exposures was 2 minutes for refueling and 24 hours for indoor and outdoor exposures.

Microenvironmental Exposures To Volatile Organic Compounds (미규모 환경에서의 휘발성 유기화합물 노출)

  • 조완근;강귀화
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.447-459
    • /
    • 1995
  • Volatile organic compounds(VOCs) are of concern for their potential chronic toxicity, their suspected role in the formation of smog, and their suspected role in destruction of stratospheric ozone. Present study evaluated the exposures to selected VOCs in three microenvironments: 2 chlorinated and 5 aromatic VOCs in the indoor and outdoor air, and 5 aromatic VOCs in the breathing zone air of gas-service station attendants. With permissible Quality Assurance and Quality Control performances VOC concentrations were measured 1) to be higher in indoor air than in outdoor air, 2) to be higher in two Taegu residential areas than in a residential area of Hayang, and 3) to be higher in the nighttime than in the daytime. Among five aromatics, Benzene and Toluene were two most highly measured VOCs in breathing zone air of service station attendants. Based on the sum of VOC concentrations, the VOC exposure during refueling was estimated to be about 10% of indoor and outdoor exposures. For Benzene only, the exposure during refueling was estimated to cause about 52% of indoor and outdoor exposure. The time used to calculate the exposures was 2 minutes for refueling and 24 hours for indoor and outdoor exposures.

  • PDF