• Title/Summary/Keyword: Residential fire

Search Result 191, Processing Time 0.035 seconds

A Study on the interior material Combustion Characteristics in residential facilities fire behavior prediction (주거시설 화재성상예측을 위한 내장재 연소특성에 관한 연구)

  • Kim, Gi Hyeon;Kim, Dong Eun;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.65-66
    • /
    • 2013
  • As a result of executing Cone Calorimeter experiment on 12 samples among combustibles of domestic residential facilities, flooring materials showed higher HRR and THR than wall papers, and in case of toxicity and SPR, wall papers having adhesive components in one side by considering use conveniences were measured high.

  • PDF

Evaluation of Escape Safety Depending on the Number of Users of Residential Convenience Facilities in the Apartment Complex and the Kind of Elevators

  • Cho, Seong-Suk;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.376-384
    • /
    • 2021
  • This study wants to provide basic data on effective escape safety plans when residents of apartment complex use residential convenience facilities. The findings of the analysis are as follows. First, when this study applied the actual number of users (No=54) of those facilities, the existence of elevator for escape reduced the escape time by 189.0 seconds. Second, when the number of users was calculated on the standard of the number of people who can be accommodated for performance based design (No=316), the existence of the elevator for escape reduced the escape time by 173.5 seconds. Finally, when the number of users was calculated on the standard of installing fire-fighting facilities (No=122), the existence of the elevator for escape reduced the escape time by 159.2 seconds. As a result, it was found that elevator for escape reduces the escape time from fire. Accordingly, it is necessary to revise the construction law to make it obligatory for residential convenience facilities to be equipped with elevator for escape. Currently, apartment buildings lower than 30 stories have either elevator for passengers or elevator for escape. Thus, in future studies, it is necessary to compare escape times in fire depending on the kinds of elevator, and identify the usefulness of elevator for escape.

A Study on Fire Behavior of Combustibles in a Residential Building (주택 가연물의 연소 특성에 관한 연구)

  • Lee, Sung-Ryong;Youk, Keun-Hwan
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.25-31
    • /
    • 2009
  • With rapid growths of economy and technology, structures and forms of buildings have been diversified and complicated. Buildings also have become higher and larger than ever before. As a result, more people use a building and more combustibles exist in the building. Without understanding of combustion characteristics and the establishment of a fire safety plan in case of a residential fire, it is expected great loss of lives and properties. In this study, experiments were carried out to promote an understanding of the combustion characteristics of combustibles in the building. Sofa and bed were used as combustibles in the experiment. Heat release rate of the sofa was about 1.9MW. Heat release rate of the bed was approximately 650kW.

An Experimental Investigation on Combustion Characteristics of the Knockdown Building (조립식 건축물의 화재특성연구)

  • Lee, Jung-Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.30-35
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Combustion products including $O_2$, $CO_2$, CO, $NO_x,$, $SO_x$, HCI, HCN were measured, in order to investigate the hazard-reduction effects of employing gas mask protected with filter during the fire emergency of residential container buildings. According to the test results, whether or not employing the filter showed a sheer difference in the toxicity of the fire-induced gases, and then the importance of wearing a gas mask was evidently demonstrated.

A Numerical Study for Fire Safety Evaluation of the Multi-story Residential Buildings -The Effects of the Openings of Stairwell on Fire Characteristics- (다세대주택의 화재안전평가에 대한 수치해석 연구 -계단실 개구부의 개폐가 화재특성에 미치는 영향-)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.15-23
    • /
    • 2007
  • In the events of a fire in the residential building, highly flammable polyurethane foam sofa produce toxic smokes. In this type of fire, the residents of the building can be gotten into the difficulties of evacuating from the fire places or may be to death due to a lot of hot toxic gases. In this study, CFD simulations were carried out to study the effects of the openings of stairwell on the fire characteristics of fire room and stairwell. Also, analysis of fire hazard based on the tenability limits of fire and FED(fractional effective dose) was performed to evaluate the life safety of the residents of the building. In the fire room, maximum temperature was about $290^{\circ}C$, maximum CO concentration was about 4,740 ppm, and the time to incapacitation of residents in fire room was about t=144 s. In the stairwell, temperature and CO concentration in the condition of openings to be open were even lower than those in it to be closed. Time to the tenability limit with respect to smoke visibility in the stairwell with openings, which was open, was shorter than that of it without openings to be open. It has been shown from this study that opening the stairwell openings is able to decrease the fire hazards to the life safety in the multi-story residential building fire.

Implementation of EO/IR Camera for Fire-fighting of Narrow Space (협소거주공간 진화를 위한 EO/IR카메라 구현)

  • Park, Hyun-Ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.628-629
    • /
    • 2018
  • Recently, residential spaces in urban areas have changed into multi - family residential spaces. There is a feature that smoke is charged when a fire occurs here. Also, the evacuation route and the direction of the outflow of smoke are the same, and the possibility of inhaling the smoke of the evacuees is very high. When fighting fire in a narrow residential space such as a dwelling in a downtown area, exploration is the most important. For this purpose, we implement EO / IR sensor which can be mounted on firefighter 's helmet and can be used for fire detection. By using the EO / IR operation test, we can derive the results that can be used for research and development of the fire search sensor.

  • PDF

Analysis of the Wireless Communication Environment in the Narrowed Residential Space for the Fire fighting Operation (소방작전을 위한 협소거주 공간의 무선 통신 환경 분석)

  • Park, Hyun-Ju;Hong, Sang-Beom;Choi, Hyuk-Jo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.242-248
    • /
    • 2017
  • Recently, Population has been concentrated in cities due to rapid economic growth. As a result, urban buildings are becoming more dense, high-rise, and diversified. The shape of these urban buildings increases the risk of fire, accidents and crime. The narrow living space has the characteristic of the unchanged floor. In case of a fire, the living space of the narrow residence is large in the damage because the smoke diffusion rate is fast. The radio wave transmittance and transmission distance of wireless communication used in fire fighting operations vary depending on the type of building materials and buildings. Therefore, this paper analyzes the building materials and structural characteristics of the narrow residential space for efficient fire fighting operations. We have developed a communication environment solution for a narrow residential space for the optimal fire fighting operation through the measurement of the radio wave transmittance and the transmission distance of the wireless communication.

Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors (화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발)

  • Park, Mi Yun;Park, Jong Bok;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The range of special management target facilities is seperated by the building sector and the field of civil engineering. In the present study, the risk analysis was performed, related to fire occurred for the last five years, in the field of residential and non-residential facilities in buildings. Most of fire incidents occurred in residential and non-residential facilities was the cause of the electrical, and the resulting casualties were also very high. Therefore, based on the results, the risk evaluation index was developed, identifying the causes of fire occur and doing the fire vulnerability analysis for each facility. The result of this study can be utilized safety management to these facilities for the future, especially, inducing a more specialized and intensive safety management.

A Study on the Improvement Direction of Life Safety Codes for High Fire Risk Building Applications (화재위험성이 높은 건축물의 용도를 대상으로 한 인명안전기준의 개선방향)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun;Koo, In-Hyuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.53-54
    • /
    • 2021
  • Grenfell Tower was renovated in 2014 and 2016 at a high cost to replace the exterior materials, windows and co-heating facilities of the building. The exterior materials used during the repair work were sandwich panels filled with polyethylene and plastic, which were expanded on the aluminum metal surface. It is a product called Celotex RS 5000, a low-resolution but inexpensive repair material, and is currently an external material that cannot be used in high-rise buildings. Similar domestic fire cases began to focus social attention on the safety of high-rise buildings through the Busan Residential Complex Fire (2010), Uijeongbu Urban Living Housing Fire (2015), and Ulsan Residential Complex Fire (2020), and residents' safety concerns are increasing. In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. Therefore, the purpose of this study is to examine the status of fire damage caused by domestic and foreign eruptions, domestic and international research status and related regulations on external materials and windows starting from the Grenfell Tower fire in England.

  • PDF

A Study on the Prevention and Extinguishment of Fire in Vinyl Temporary Buildings for Agriculture and Fishery (농·어업용 Vinyl 가설건축물의 화재 예방 및 진압에 관한 연구)

  • Bong-Woo Lee;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.599-603
    • /
    • 2023
  • Analyzed in the NFDS, The average number of fires in vinyl temporary buildings is more than 1,000 in annually. And the number of deaths and injuries was around 30 people in every year. According to the National Fire Agency, There are 142,386 vinyl temporary buildings for Agriculture and Fishery, of which 4,720 are residential vinyl temporary buildings in illegally. Model house is subject to regulation in fire-related law. But, even though it's the same temporary building, Vinyl temporary building is not subject to regulation. For this reason, Vinyl temporary buildings are left in the blind spot of fire safety. Therefore, In this study, We propose that amend of Act on installation and management of firefighting systems, make of temporary fire safety controller, develop and apply of alarm system that is connected to a single-alarm smoke dretector, organize and operate volunteer fire brigade of the crop group to prevent and extinguish the fire.