• Title/Summary/Keyword: Residential fire

Search Result 191, Processing Time 0.027 seconds

A Study on Intelligent Space Design Supporting the Elderly - Focused on the Needs of the Aged on Digital Systems in Residential Space - (노인을 위한 지능형 공간환경 연구 - 주거공간의 디지털 시스템화를 위한 노인요구 조사를 중심으로 -)

  • Oh, Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.5
    • /
    • pp.61-71
    • /
    • 2008
  • The study alms to seek a plan of applying the digital technology to housing for the elderly. The purpose of the study was to grasp the needs of the aged on 30 types of digital systems in housing. The subjects were 120 persons aged of more than 60 years and lived in Busan. Data were collected by the individual interview. The following results were drawn from this study. First, the needs of the aged on the digital systems categorized as safe and security, control of indoor environment, and housework support were very high and should be provided at first. Second, the necessary types of digital systems which should be provided to the digital home for the elderly were digital systems for heating control, health checking, sensing of fire and gas leak, and house cleaning. Also, the basic types of digital systems were ones for invasion and burglarproof, emergency, air cleaning, automatic facet, door locking, and waste collecting. Third, the Income and usage level of digital equipment of the aged influenced to the floods of the aged on the digital system. Therefore, in addition to the necessary and basic types of digital systems mentioned above, the income and usage level of digital equipment should be considered in planning the digital home for the elderly.

Evaluation of Vulnerability on Rural Emergency Relief Service using Text Mining (Text Mining 기법을 활용한 농촌마을 긴급구호서비스 접근 취약성 평가)

  • Woo, Jaehyeong;Park, Jinseon;Yoon, Seongsoo
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.1
    • /
    • pp.67-74
    • /
    • 2018
  • The rural areas are large residential space with fewer people than urban areas. That is why they are vulnerable to social services such as health care and security. This research analyzed the vulnerability of emergency relief service in rural village through text mining and the weighting value have been calculated. Based on the calculated statistics data, the police facilities are the most important, While the fire fighting and hospital facilities are important as well. In addition, the distance from the emergency relief service facility to the rural village was confirmed by using Open API. By combining these results, The vulnerable areas of the rural villages and the emergency relief service facilities were calculated and classified into 5 levels. For rural areas, the 1st class will have 33 places, following by 1,179 in 2nd class, 199 in 3rd class, 17 in 4th class and 8 in 5th class. Hence in order to further supplement the vulnerable areas to emergency relief service in villages, geographical relocation and policy approach of emergency relief service facilities are necessary.

Influence Factors on Health and Medical of Retirees Expense to Public Pension Recipients (공적연금유형에 따른 은퇴자들의 보건의료비지출 결정요인)

  • Choi, Ryoung;Hwang, Byung Deog
    • Health Policy and Management
    • /
    • v.25 no.2
    • /
    • pp.80-89
    • /
    • 2015
  • Background: This study aims to identify the monthly average medical expenses of public pension recipients, and analyze the determinants of total health and medical expenses and Western and Oriental medicine expenses, medical service expenses, and medical supplies expenses. Methods: This study used the fifth year data of 2013 out of the raw data of the Korean Retirement and Income Study collected by the National Pension Research Institute. This study conducted t-test, analysis of variance, and linear regression to verify publicly the relevance between pension recipients' general characteristics and health and medical expenses status using IBM SPSS ver. 21.0 for data analysis. Results: It was analyzed that there is a difference in the spending of expenditure and health care costs according to public pension recipients. Medical expenses of the national pensioners was higher compared to the special corporate pensioners. The national pensioner is related expenditure size, education level, family members living together, residential areas, status of spouse, number of chronic illness, and status of limitation in daily life with psychological health status. Conclusion: Therefore, fairness does not occur fire to the medical use between the special corporate pensioners and national pensioners, aggressive of government such as health policy and financial support for the retiree pension policy that reflects the reality intervention would be required.

Experiments on the Influence of Opening of Natural Smoke Ventilators on the Stack Effect in High-rise Mixed-use Residential Buildings (초고층주상복합건물에서 배연창 개방이 연돌효과에 미치는 영향에 대한 실험적 연구)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.89-94
    • /
    • 2009
  • The stack effect in high-rise buildings is expected more significant at nights in winter due to the large temperature difference between the inside and outside of the buildings. However, the existence of large openings such as natural ventilators on the floor may effect the position of neutral plane, smoke spread at fire and thus obstruct the door openings for rescue. In this paper, the vertical and horizontal pressure distribution with different openings of natural smoke ventilators was experimentally analyzed by investigating pressure differentials.

A Study of Risk Analysis for Underground-parking of Gas Vehicle (가스 자동차의 지하 주차 시 위험성 분석)

  • Rhie, Kwang-Won;Kim, Tae-Hun;Oh, Dong-Seok;Oh, Young-Dal;Seo, Doo-Hyoun;Shin, Soo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • We studied the risk analysis of fire and explosion caused by gas leak in underground-parking of gas vehicle. However, an entrance regulation of gas vehicles (H2/LPG/CNG etc.) to underground garages has not been enacted in Korea. Incase, a gas explodes in an underground parking garage placed in overcrowded residential area, such as an apartment, the scale of the damage would cause tremendous disaster. Faults of vehicle parts and management problems were evaluated by using the Failure mode and effect analysis (FMEA), which is a qualitative analysis method. The range of the damaged area by the explosion and the damage scale by the explosion pressure were analyzed by using the process hazard analysis software tool (PHAST). The study is expected to facilitate enactment of the regulation for the underground parking to restrict the gas vehicle.

Qualitative Risk Assessment of Hydrogen Compression Reforming Process (수소 압축 개질공정의 정성적 위험성 평가)

  • SHIN, DANBEE;SEO, DOOHYOUN;KIM, TAEHUN;RHIE, KWANGWON;LEE, DONGMIN;KIM, HYOUNGI;HONG, SEONGCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2022
  • In order to introduce the hydrogen economy and increase supply, research in the field of hydrogen production is being actively conducted. Among the hydrogen production methods, the method of steam reforming from natural gas and producing it currently accounts for about 50% of the global hydrogen production. In the method of steam reforming process, hydrogen can be produced by adding a reformer to an existing natural gas supply pipe. Because of these advantages, it is evaluated as a realistic production method at present in Korea, where the city gas supply chain is well established. But there is concern in that it is highly likely to be installed in downtown areas and residential spaces. In this study, the risk of the process of steam reforming to produce hydrogen was reviewed.

A Study on the External Wall Heating Temperature Distribution According to Opening Size in Building (건물의 개구부 크기에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.261-267
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as following: when the experiment was conducted with opening sizes(horizontal length) each at 2,000mm, 1,600mm, and 1,400mm, the flashover occurred at 630 seconds, 505 seconds and 510 seconds, respectively. Also, the total heating time, in proportion to this, came to 815 seconds, 713 seconds and 721 seconds. The maximum heating temperature of the exterior wall by the opening size reached 282.4℃ at 2,000mm, 382.9℃ at 1,600mm, and 423.8℃ at 1,400mm. This represented that as the opening size gets smaller, the heating temperature of the exterior wall by fire spread becomes higher.

Seasonal Variations of Water Quality and Phytoplankton of 4 Lagoons in the East Coast of Korea (동해안 4개 석호의 수질과 식물플랑크톤 계절별 변화에 관한 연구)

  • Moon, Byeong Ryeol;Jeon, Hyeon-Jin;Jeon, Sook Lye;Lee, Jae Sun;Shin, Ji Eun;Ahn, Ji Hye;Yang, Yong Woon;Hyun, Moon Sik;Kim, Mia
    • Journal of Environmental Science International
    • /
    • v.24 no.9
    • /
    • pp.1101-1121
    • /
    • 2015
  • The seasonal variation of phytoplankton communities and its standing crops in accordance with environmental factors were investigated at Yeongrang-ho, Cheongcho-ho, Mae-ho and Hyang-ho which are located in the East coast of Korea during April to October 2011. High concentrations of T-N and T-P were observed in four lagoons due to the inflowing nutrients from farmlands and residential areas near lagoons. Nutrient salts mainly composed of nitrogen and phosphate caused the eutrophication of the lakes, leading to the robust growth of phytoplankton. During the period of investigation, 64 to 107 taxa of phytoplankton were observed in four lagoons. Diatoms were the most dominant species with high density. Non-point pollution source was estimated as the main cause of water pollution of lagoons. Trophic states of lagoons evaluated using the value of TSI and TSIKO indicated that all the investigated lagoons were in the eutrophication state.

A Study on the Construction Methods of Sealer of Injection Type for Leakage Maintenance for Water Leakage and Cracks in Concrete (콘크리트 누수균열의 유지관리를 위한 누수보수용 주입형 실링재 시공방법 연구)

  • Kwon Shi-Won;Oh Mi-Hyun;Kwak Kyu-Sung;Oh Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.1 s.19
    • /
    • pp.87-91
    • /
    • 2006
  • Since water leakage and cracks are not the source of serious problems such as long-term lowering of performance and durability of a stricture, including damages to operating facilities of a structure, damages to internal finishing materials, exhibition, and goods, and pollution of residential environment, they might have led to development of positive coping skills; however, an instant loss of lives or property due to earthquake, explosion, typhoon, or a fire was indeed neglected. In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if this costs a lot. It was not arrange the standard for construction methods of sealer of injection type for leakage maintenance, even it has been used various type of construction methods for leakage part. In conclusion, we suggest that the construction methods of sealer of injection type for leakage maintenance for leakage to establish the leakage repairing technology as increase of structure demand. Therefore, it would be possible to provide a stage-by-stage solution by developing systematic research activities among the industry, schools, and research institutes to spread maintenance management techniques globally through technical solution to water leakage and cracks, acquisition of structural safety with prolonged durability for life cycle, reduction of water leakage repair expense s, and so on.

A Study on the External Wall Heating Temperature Distribution According to Opening Upper Shading Installation and Length (개구부 상부 차양설치 및 길이에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.339-345
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as follow : On top of this, the experimental conditions had whether to install shading and put a shading length differently, before measuring and analyzing the heating temperature of the exterior wall. Subsequent results were drawn as shown below. Based on the maximum temperature, the temperature was lowered as much as around 90℃ at 150mm, around 150℃ or over at 300mm and over 175℃ at 450mm. It also turned out that the difference in maximum temperature dropped by around 180℃ or over. This indicated that the shading installation works well in lowering flame temperature generated by fire spread of the exterior wall.