• Title/Summary/Keyword: Residential Environment Evaluation

Search Result 228, Processing Time 0.026 seconds

A study on the effectiveness of Senior living environmental improvement through remodeling of old apartment complex (노후 임대아파트단지 리모델링을 통한 노인거주환경개선효과에 관한 연구)

  • Kwon, Soonjung;Kang, Hyojin;Oh, Ga Young;Kim, Seok Jun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.93-104
    • /
    • 2017
  • Purpose: Korean society has already entered an aged society but there aren't many evidence-based studies on the elderly-friendly design elements in the apartment environment, which is the main residential type in Korea. The main purpose of this study is to verify the necessity and expandability of the outdoor environment design in the public rental apartment complex through the evaluation of the effectiveness and satisfaction of SMG(Seoul Metropolitan Government) Cognitive Health Design Project in GR 1 apartment complex. Methods: The research subjects were GR 1-complex as experimental group and the nearby Wolgye Deer 1-complex as control group, both public rental apartment and located in Seoul. As a research method, the survey was conducted before and after the implementation of SMG project for residents of the apartment. A total of 200 preliminary surveys and 203 post surveys were conducted. Results: As a result of this study, residents' accidents related safety have decreased, and both the frequency of use and satisfaction of most facilities have increased. It is noteworthy that the increase in cognitive items in the post-survey. Also, 74.5% of the residents evaluated that the complex was better to live after the project was implement. Implications: The fact that the preliminary surveys were not conducted for the same person is considered as the limitation of the study, but it is meaningful in that it systematically assesses the effectiveness of the project on the cognitive health of the outdoor residential environment towards age-friendly city.

A Basic Study for Sustainable Analysis and Evaluation of Energy Environment in Buildings : Focusing on Energy Environment Historical Data of Residential Buildings (빌딩의 지속가능 에너지환경 분석 및 평가를 위한 기초 연구 : 주거용 건물의 에너지환경 실적정보를 중심으로)

  • Lee, Goon-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.262-268
    • /
    • 2017
  • The energy consumption of buildings is approximately 20.5% of the total energy consumption, and the interest in energy efficiency and low consumption of the building is increasing. Several studies have performed energy analysis and evaluation. Energy analysis and evaluation are effective when applied in the initial design phase. In the initial design phase, however, the energy performance is evaluated using general level information, such as glazing area and surface area. Therefore, the evaluation results of the detailed design stage, which is based on the drawings, including detailed information of the materials and facilities, will be different. Thus far, most studies have reported the analysis and evaluation at the detailed design stage, where detailed information about the materials installed in the building becomes clear. Therefore, it is possible to improve the accuracy of the energy environment analysis if the energy environment information generated during the life cycle of the building can be established and accurate information can be provided in the analysis at the initial design stage using a probability / statistical method. On the other hand, historical data on energy use has not been established in Korea. Therefore, this study performed energy environment analysis to construct the energy environment historical data. As a result of the research, information classification system, information model, and service model for acquiring and providing energy environment information that can be used for building lifecycle information of buildings are presented and used as the basic data. The results can be utilized in the historical data management system so that the reliability of analysis can be improved by supplementing the input information at the initial design stage. If the historical data is stacked, it can be used as learning data in methods, such as probability / statistics or artificial intelligence for energy environment analysis in the initial design stage.

Analysis on Different Ideas of Rural Housing Environmental Results : - Focused on Opinion of Public Officials and Inhabitants in Cheongwon-gun - (농어촌주거환경개선사업의 시행결과에 대한 인식차이 분석 - 청원군 공무원과 주민의 의견을 토대로 -)

  • Ko, Hye-Jin;Lee, Geun-Bok;Hwang, Hee-Yun
    • Journal of Korean Society of Rural Planning
    • /
    • v.15 no.3
    • /
    • pp.23-32
    • /
    • 2009
  • The purpose of this research was to evaluate rural housing environment through evaluation of the two parties, public officials, the interest group and residents, the beneficiaries surveying general understanding and measuring difference in understanding between public officials and residents. Through the difference in understanding, this study was to propose effective promotion method and desirable direction of rural housing environment. For progress hereafter, by seeking active involvement of residents, this study proposed possible renewal plan of residential environment. Process of this study was first, research documents to examine several rural housing environment related promotions, and several analysis techniques like principal component analysis, multiple regression analysis used to understand different ideas Opinion of Public Officials and Inhabitants. Then take surveys of residents living in renewal zone, and surveys of public officials of borough, which already performed renewal projects to evaluate comprehensively as either residents' or administrators' view.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.17 no.2
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

The Evaluation of Outdoor Environmental Quality Level at the Improvement Area of Residential Environment - Case Study of Taegu - (주거환경개선사업 지구의 옥외환경의 질적수준평가 - 대구광역시를 중심으로 -)

  • 최영은;오병남;홍원화;하재명
    • Journal of the Korean housing association
    • /
    • v.10 no.4
    • /
    • pp.63-70
    • /
    • 1999
  • The purpose of this study is to evaluate the outdoor environmental quality level at the improvement areas of residence and examine the changes of these areas where the improvement process has been performed. The indicators of outdoor space were examined for case study and several improvement areas were selected and analyzed in terms of these indicators. The improvement areas may be divided into two branch, one is a housing improvement area and the other is a multi-family housing area. The results of this study were as follows; 1) Land-use intensity in both cases was much higher than before. 2) Open space ratio in the housing improvement areas was not enough but in the multi-family housing areas was enough. 3) The road ratio in both cases was much higher. 4) Parking space was not enough to accomodate all the cars in projects. 5) Public facilities and green space did not exist in housing improvement areas but existed a little in multi-family housing areas. In order to improve the environmental quality level, the proper residential density such as dwelling density, open space ratio, land-use intensity should be planned in advance.

  • PDF

A Study on the Window Energy Rating Systems in Residential Buildings (주거용 건물의 창호에너지평가시스템에 관한 연구)

  • Kim, Dong-Yun;Lim, Hee-Won;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.33-41
    • /
    • 2016
  • Purpose: The window energy rating system was developed in early 1990's and various kind of rating system has been implemented in advanced country such as Europe, Australia, Canada and the US since 2000. In Korea, the Energy Consumption Efficiency Rating Indication System has been implemented to promote supply of high efficiency window since July 2012. Normally, the window energy rating system based on heat balance which considers both thermal losses and solar heat gain is used and applied only to residential buildings. However, the system used nationally only considers thermal losses and is applied to every building regardless of its usage. Therefore, in this study, we indicated problems of domestic window energy rating system and looked for improvements. Method: We analyzed thermal performance of various windows through dynamic simulation applied to detached house and compared results with those of domestic and foreign rating system. Result : Thermal performance of south windows is more affected by SHGC than U-value, and that of north windows is also affected by SHGC a lot. The difference between the results of our study and current system is statistically significant. As a result, appropriate evaluation criteria which considers solar heat gain is required.

Simulation of Changes in Nearby Thermal Environment According to Green Roof in Low-Rise Residential Area of Daegu (대구광역시 저층주거지역의 옥상녹화 조성에 따른 주변 열환경 변화 모의실험)

  • Kim, Dae-Wuk;Jung, Eung-Ho;Cha, Jae-Gyu
    • Journal of the Korean housing association
    • /
    • v.24 no.3
    • /
    • pp.45-53
    • /
    • 2013
  • It is important to secure green spaces to solve the urban heat island phenomenon, which is among problems resulted by high-density developments in metropolitan areas. However, it is hard to secure such green spaces in established urban areas so Green Rooftop development approaches have recently been highlighted and introduced as a solution to the situation. The present study conducts a simulation on residential areas in urbanized regions to quantitatively evaluate the effects of green rooftop developments through a comparison of changes in the air temperatures before and after relevant development projects. According to the evaluation results, when the green roof top development is conducted in the available areas, the temperature is reduced by 0.14 degree. The extension of green project to the entire building showed the reduction of the temperature by 0.29 degree. Based on these results, it can be concluded that the green rooftop development is a practically solution for reducing the air temperature of urbanized areas.

Health risk assessment by CRPS and the numerical model for toluene in residential buildings

  • Choi, Haneul;Kim, Hyungkeun;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.17 no.5
    • /
    • pp.33-41
    • /
    • 2017
  • Purpose: Indoor air quality in residential buildings needs to be evaluated over the long term. In previous research, there has been an attempt to perform the health risk assessment of pollutants by using numerical models as a method of long-term evaluation. However, the numerical model of this precedent study has limitations that do not reflect the actual concentration distribution. Therefore, this study introduces the CRPS index, constructs a numerical model that can reflect the concentration distribution, and then presents a more accurate health risk assessment method using it. At this time, the pollutants are toluene, which is a typical material released from building materials. Method: CRPS index was applied to existing numerical model to reflect concentration distribution. This was used to calculate concentrations at adult breathing area and to use them for exposure assessment in a health risk assessment. After that, we entered adult data and conducted a health risk assessment of toluene. Results: The non-carcinogenic risk of toluene was calculated to be 0.0060. This is 5% smaller than the existing numerical model, meaning that it is more accurate to predict the pollutant risks. This value is also lower than the US EPA reference value of 1. Therefore, under the conditions of this study, long-term exposure of adults to toluene has no impact on health.

The Comparative Study on Performance Evaluation of Outdoor Space for Remodeling Apartment (리모델링 공동주택단지의 외부공간 성능평가 비교 연구)

  • Kim, Ho-Yun;Lee, Sang-Suk;Yu, Joo-Eun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.4
    • /
    • pp.1-17
    • /
    • 2016
  • In this study, remodeling projects are perceived as a sustainable urban management policy to boost the value of old apartments and stimulate urban regeneration and development. To evaluate the physical environmental performance of external spaces of remodeled apartments, an evaluation model was developed. After applying it to the target places, the following results were obtained. First, analysis of the external space change index of the target apartments revealed that institutional standards are necessary in line with the building arrangement type, parking lot expansion method, and changes in the building-to-land ratio. Second, the score ratio as to the external space change index performance is as follows: safety (48.30); pleasantness (25.90); convenience (18.90); eco-friendliness (14.90). In other words, "safety" had the biggest score ratio. Third, to boost the external space performance of remodeled apartments, the needs of residents and neighboring environmental plans should be considered from a communality standpoint.

A Basic Study on the Application of Text-Maining Method for Qualitative Evaluation through Barrier Free Certification in School Facilities (학교시설의 장애물 없는 생활환경(Barrier Free) 인증 사례를 통한 정성평가 텍스트마이닝 기법 적용에 관한 기초연구)

  • Yun, Pyeong-Se;Lee, Jong-Kuk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.19 no.1
    • /
    • pp.25-35
    • /
    • 2020
  • Since the introduction and operation of BF certification, a total of 6,432 certificates has been issued until February 2020, of which educational research facilities make 1,091 cases (754 preliminary certification, 337 main certification) out of 6,237 buildings, acquiring BF certification of about 20%. Qualitative evaluation is conducted with focus on the three items of BF-certified building evaluation index, which are medium facilities, internal facilities, and sanitary facilities, and major keywords are the deducted through the Text Mining analysis of the derived results. As a result, problems with access paths occurred in the case of the facilities, and assessment indicators for users were found to be necessary among the assessment of the steps of the internal facilities. Finally, we could see that sanitation facilities needed to improve toilets installed in residential development facilities. Based on the results obtained, the study seeks to suggest directions for improving the evaluation index required for BF-certified school facilities.