• Title/Summary/Keyword: Residence zone

Search Result 95, Processing Time 0.02 seconds

Numerical analysis of NOx reduction for compact design in marine urea-SCR system

  • Choi, Cheolyong;Sung, Yonmo;Choi, Gyung Min;Kim, Duck Jool
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.6
    • /
    • pp.1020-1033
    • /
    • 2015
  • In order to design a compact urea selective catalytic reduction system, numerical simulation was conducted by computational fluid dynamics tool. A swirl type static mixer and a mixing chamber were considered as mixing units in the system. It had great influence on flow characteristics and urea decomposition into ammonia. The mixer caused flow recirculation and high level of turbulence intensity, and the chamber increased residence time of urea-water-solution injected. Because of those effects, reaction rates of urea decomposition were enhanced in the region. When those mixing units were combined, it showed the maximum because the recirculation zone was significantly developed. $NH_3$ conversion was maximized in the zone due to widely distributed turbulence intensity and high value of uniformity index. It caused improvement of $NO_x$ reduction efficiency of the system. It was possible to reduce 55% length of the chamber and connecting pipe without decrease of $NO_x$ reduction efficiency.

Nitrogen Transport In Groundwater-Surface Water Hyporheic Zone at Brackish Lake (기수호의 지하수-지표수 혼합대 내 질소 거동 분석)

  • Seul Gi Lee;Jin Chul Joo;Hee Sun Moon;Su Ryeon Kim;Dong Jun Kim
    • Ecology and Resilient Infrastructure
    • /
    • v.11 no.2
    • /
    • pp.23-34
    • /
    • 2024
  • Sediment, aquifer materials, surface water, and groundwater from brackish Songji lake affected by salinity of seawater, were collected and a pilot scale column experiment was conducted to simulate the nitrogen transport through the hyporheic zone. Upstream experiments of groundwater displayed that groundwater containing a small amount of salt percolated into aquifers and sediments, maintaining low dissolved oxygen concentrations. In addition, partial denitrification occurred in the aquifer due to salinity and low dissolved oxygen, resulting in the accumulation of NO2-. In sediments,nitrogenous compounds were reduced due to adsorption by long residence times or microbial-mediated oxidation/reduction reactions. Downstream experiments of surface water displayed that surface water from the brackish lake, containing high concentrations of dissolved oxygen and salts, infiltrated into the sediments and aquifer, supplying high dissolved oxygen concentrations. This resulted in biological nitrification in the sediments and aquifer, which reduced nitrogen-based pollutants despite the high salt concentration in the surface water. Whereas partial denitrification at low dissolved oxygen concentrations in the upwelling mixing zone was observed by salinity and accumulated NO2-, nitrification at high dissolved oxygen concentrations in the downwelling mixing zone was not significantly affected by salinity. These results confirm that salinity in the brackish water lake has some influence on the nitrogen behavior of the hyporheic mixing zone, although nitrogen behavior is a complex combination of factors such as DO, pH, substrate concentration, and organic matter concentration.

Analysis of the Characteristics of the Change in the Moisture Rate of Landfill with Recirculation Water Injection (재순환수 주입에 따른 매립장 함수율 변화특성 분석)

  • Kim, Young-Kyu;Choi, Won-Young;Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.39-48
    • /
    • 2021
  • Analysis of the change in water content and distribution was conducted according to the supply of recirculation water to a landfill. An excavation sample analysis showed that the recirculation water injection zone had water content 8.8% point higher than that of the non-injection zone, after 8 months of operation. And due to the influence of recirculation water supply by vertical wells in injection zones, the water content increases along with depth more clearly than non-injection zone. According to an electrical specific-resistivity survey after 13 months of operation, the water content got higher towards the bottom of the landfill. The water transmission coefficient is 8.72×10-4 cm/sec for injection zones and 3.36×10-5 cm/sec for the intermediate cover layer; analysis shows that the intermediate cover layer may affect the penetration velocity of water supplied by the horizontal injection tube. For the scientific design and operation of re-injection facilities, it was deemed necessary to follow-up research on the residence time and behavior of re-injection water considering the ratio of recirculation water supply in horizontal and vertical tubes, and pitcher coefficient of intermediate and waste layers.

The Study of Numerical Simulation on the Thermal Flow Performance for the Design of Low Emission Stoker Type Municipal Waste Incinerator (저공해 스토커형 도시폐기물 소각로 설계를 위한 열유동 수치해석 연구)

  • 전영남;송형운;김미환
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.543-551
    • /
    • 2002
  • A Numerical simulation on the thermal flow performance was carried out to propose the incinerator type for the domestic refuses and to investigate the design factor and operating conditions. The SSTI(Standard Stoker Type Incinerator) proposed in this study was modified from the type with central f)ow. It has the characteristics of good mixing between refuse and hot combustion gas in primary combustion chamber and between unburned gas inflowing and secondary air jet in secondary chamber. By predictive results, the SSTI was no recirculation zone in secondary chamber so that mixing time was increased with high residence time. It has good characteristics of combustion and low emission. Parametric screening studies have been understood with phenomenon of combustion in incinerator.

The Study on the Gas Temperature Set by Calculating the Sensitivity of Slab Temperature in Reheating Furnace (소재온도 감도계산을 통한 가열로내 분위기온도 설정방안 연구)

  • Gang, Deok-Hong;Kim, Gi-Hong;Lee, Yong-Guk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1030-1036
    • /
    • 2001
  • A new mathematical model to determine the optimal gas temperatures in reheating furnace was proposed for the good quality of products. This model employs sensitivity method to calculate the optimal gas temperatures in each zone for heating the slab up to its discharging target temperature and for heating it uniformly. This method was validated by showing that the calculated discharging temperature of the slab was in a good agreement with its prescribed discharging target one through an off-line simulation.

A Study on Characteristics of the Dewller's Character in Munhwa-Maule (문화마을 거주자 특성에 따른 공간이용실태에 관한 연구)

  • Park, Do Yong;Lee, Deog Yong;Yoon, Choong Yeul
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.6 no.3
    • /
    • pp.87-95
    • /
    • 2004
  • At the beginning of 1990s, in the on of ways improving tyong he structure of comunity in the agri cultural country. A creation of Munhwa-Maule has been begun. It has been performed for Center village of Munhwa-Maule, and worked in order to improve the creation budiness for Munhwa-Maule was starte d for the qualitative rasing of the people life in the agricultural zone. Through this study : utilization of residence between a farming family and a non-farmig family, I made an analysis about problem with finding out the whole of the village, but the condition of using house com es to the end. I use a lot of studies be lasted in many ways about estimation and craft arranging village after moving into the Munhwa-Maule.

  • PDF

Investigation of NOx Formation Charateristics in Multi Air Staged Spray Combustor (공기 다단 분무연소기의 NOx 발생특성에 관한 실험적 연구)

  • Kim, Han-Seok;An, Guk-Yeong;Kim, Ho-Geun;Baek, Seung-Ok
    • 연구논문집
    • /
    • s.31
    • /
    • pp.23-43
    • /
    • 2001
  • An experimental investigation on the reduction of nitrogen oxide emission from swirling, turbulent diffusion flames was conducted using multi air staged combustor, The combustor utilizes swirler to dampen fuel/air mixing, allowing an extended residence time for fuel pyrolysis and fuel-N conversion chemistry in an locally fuel-rich environment prior to burnout. This process also allow to reduce thermal NOx formation to lessen the temperature of reaction zone. The aerodynamic process therefore emulates the conventional staged combustion process, but without the need for the physically separate fuel-rich and -lean stages. Parametric studies on the ratios of each staged air and droplet size were carried out the feasibility of fuel/air mixing for low NOx combustion with diesel and pyridine mixed diesel fuel oil.

  • PDF

A Study on the Demand of Development in the Villages of Rural Areas - Focused on the Analysis of Preliminary Plans about Rural Community Development Project - (농촌지역 마을의 개발수요에 관한 연구 -농촌마을종합개발사업 예비계획서 분석을 통해-)

  • Cho, won-seok;Yoo, Young-Mo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.3
    • /
    • pp.21-28
    • /
    • 2011
  • This paper was able to indicate to the results the following thing that attempted a required potential development demand, through the contents and cost analysis in Rural Community Development Project. Nowadays, Rural Areas comparatively have a lot of development demands related to improvements environmental of residence life and construction of Urban-Rural Exchange Facility, on the other and, there is comparatively a few facilities demands regarding agriculture production. Demand is cold storage facilities and agricultural products direct sale facilities expansion to be able to raise value added of agricultural products as facilities related comparatively a little agriculture production, and an improvement of residence life comparatively has a lot of repair environmental uninhabited house repair, river-front and the roadside, rest shelter creation demands. However, that should be forecasted so that aging of rural, population decrease and development demand is caused by a lot of issues such as maintenances operation of many Urban-Rural Exchange Facilities and a similar program and content has a lot of them in bilateral adjacent zones. Therefore, in the future plan shall attempt efficiency operating facilities and a program through characterization and network of zone so that facilities and program can have complementary relation in the adjacent zones. And item development and an investor are necessary regarding new labor force supply for continuous value maintenance of space and returning to the farm that there were the reverse agriculture production and Amenity which are an rural village. Furthermore, developmental plan of rural village is necessary through the demand analyses that a citizen wishing for things.

Functional Modifications of Daechung Reservoir Eutrophication by Upper Dam Construction (상류댐 건설에 따른 대청호 부영양화에 대한 기능 변화)

  • Lee, Soon-Cheol;Han, Jung-Ho;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.3
    • /
    • pp.348-359
    • /
    • 2008
  • The objectives of the study were to elucidate functional modifications in relation to hydrological, physico-chemical and ecological aspects in Daechung Reservoir by the upper dam constructions of Youngdam Reservoir and analyze temporal and spatial dynamic patterns using trophic parameters of TN, TP, chlorophyll (CHL), and Secchi depth (SD). Hydrological data such as inflow, precipitation, and water levels before (BDC, 1995$\sim$2000) and after (ADC, 2001$\sim$2006) the dam construction showed that precipitation had greater correlations with inflow volume in the BDC (r=0.964, p=0.002) than in the ADC (r=0.857, p=0.029). This outcome indicates that the upper dam construction influenced the inflow and water level of Daechung Reservoir. One of the greatest changes after the dam construction was decreases of nutrient contents (TN, TP) and increases of algal biomass (as CHL) as the water residence time increases. Values of CHL had greater relations with TP in the ADC (r=0.412, p<0.001) than the BDC (r=0.249, p<0.001), indicating that CHL had greater response at a given phosphorus in the ADC. Thus, algal yield at a given TP (CHL : TP ratios) increased in the ADC, resulting in a greater CHL-TP relations. Long-term interannual TP, TN, SD, and CHL showed greater variations in the riverine zone (RZ) than any other transition (TZ) and lacustrine zones (LZ). This phenomenon was mainly attributed to rapid hydrological response in the riverine zone (RZ) to flow reductions (short water residence time) from the upper dam, resulting in ambient contents of nutrients and light regime along with functional relations of CHL-TP.

Investigation on the Hydrodynamic Behaviors of the Clarifier with an Interior Baffle in WWTP by using of Radiotracer $^{99m}Tc$ ($^{99m}Tc$ 추적자를 이용한 하수처리 시설 내 침전조의 정류벽 설치 유무에 따른 유체거동 변화측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.117-122
    • /
    • 2007
  • The hydrodynamic behaviors of the clarifier with an interior baffle in a wastewater treatment plant was investigated by using a radiotracer $^{99m}Tc$(30 40 mCi) to verify the results of CFD(computational fluid dynamics) modelling in the previous study. The clarifier model was manufactured with consideration to the hydraulic similarity(1/21) of a real plant($L{\times}W{\times}H:2.6{\times}0.4{\times}0.2m$). By installation of an interior baffle to the clarifier, the strong density current at the bottom of the clarifier decreased substantially and increased the area of sludge settling zone, which were visualized successfully from the radiotracer experiment. Also the portion of short circuit stream changed from 48 % to 32 % and the mean residence time of sludge decreased from 940 sec to 810 sec, which corresponds to the results of CFD modelling. As a result, it is anticipated that radiotracer technology can be used as an important tool for designing new wastewater treatment plants and verifying their performances after structural modifications.