• Title/Summary/Keyword: Reservoir type

Search Result 257, Processing Time 0.027 seconds

Development of engineering software to predict the structural behavior of arch dams

  • Altunisik, Ahmet Can;Kalkan, Ebru;Basaga, Hasan Basri
    • Advances in Computational Design
    • /
    • v.3 no.1
    • /
    • pp.87-112
    • /
    • 2018
  • In this study, it is aimed to present engineering software to estimate the structural response of concrete arch dam. Type-1 concrete arch dam constructed in the laboratory is selected as a reference model. Finite element analyses and experimental measurements are conducted to show the accuracy of initial model. Dynamic analyses are carried out by spectrum analysis under empty reservoir case considering soil-structure interaction and fixed foundation condition. The displacements, principal stresses and strains are presented as an analysis results at all nodal points on downstream and upstream faces of dam body. It is seen from the analyses that there is not any specific ratio between prototype and scaled models for each nodal point with different scale values. So, dynamic analyses results cannot be generalized with a single formula. To eliminate this complexity, the regression analysis, which is a statistical method to obtain the real model results according to the prototype model by using fitting curves, is used. The regression analysis results are validated by numerical solutions using ANSYS software and the error percentages are examined. It is seen that 10% error rates are not exceeded.

Numerical analysis of liquid flow characteristics according to the design parameters of a bubble jet microactuator (마이크로 엑츄에이터의 설계변수에 따른 유동특성 해석)

  • Ko, Sang-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.605-612
    • /
    • 2016
  • A numerical analysis was performed on the effect of the design parameters of a bubble jet type microactuator on its liquid flow characteristics. The numerical models included the ink flow from the reservoir, bubble formation and growth, ejection through the nozzle, and dynamics of the refilling process. Because the bubble behavior is a very important parameter for the overall actuator performance, the bubble growth and collapse phenomena in an open pool were simulated in the present study. The drop ejection and refill process were numerically predicted for various geometries of the nozzle, chamber, and restrictor of the bubble jet microactuator. The numerical results from varying the design parameters can help with predicting the performance and optimizing the design of a microactuator.

Long-Term Simulation of Reservoir Sedimentation Considering Particle-Size Distributions of Suspended Sediment and Bed Materials (부유사 및 하상토 입도분포를 고려한 저수지 퇴사의 장기모의)

  • Kim, Dae Geun;Shin, Kwang Gyun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.1
    • /
    • pp.87-97
    • /
    • 2013
  • The bed change model of HEC-RAS was used to predict the formation of a delta upon an influx of high-density sediment while taking the particle-size distributions of the suspended sediment and bed materials into account. The model was able to reasonably predict both the spatial-temporal distribution of the delta and the amount of deposited sediment according to the grain size. In addition, it was able to estimate the main type of grains that sediment at particular locations at particular times moderately well. It is expected that the simulation and the analysis considering these particle-size distributions of sediment will provide important information on planning and maintenance of the water resource related facilities.

Evaluation of the rat tissue reaction to experimental new resin cement and mineral trioxide aggregate cement

  • Yang, Won-Kyung;Ko, Hyun-Jung;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.194-200
    • /
    • 2012
  • Objectives: New resin cement (NRC) has been developed as a root repairing material and the material is composed of organic resin matrix and inorganic powders. The aim of this study was to compare the rat subcutaneous tissue response to NRC and mineral trioxide aggregate (MTA) cement and to investigate the tissue toxicity of both materials. Materials and Methods: Sixty rats received two polyethylene tube-implants in dorsal subcutaneous regions, MTA and NRC specimens. Twenty rats were sacrificed respectively at 1, 4 and 8 wk after implantation and sectioned to 5 ${\mu}m$ thickness and stained with Hematoxylin-Eosin (H-E) or von-Kossa staining. The condition of tissue adjacent to the implanted materials and the extent of inflammation to each implant were evaluated by two examiners who were unaware of the type of implanted materials in the tissues. Data were statistically analyzed with paired t-test (p < 0.05). Results: In specimens implanted with both NRC and MTA, severe inflammatory reactions were present at one wk, which decreased with time. At eighth wk, MTA implanted tissue showed mild inflammatory reaction, while there were moderate inflammatory reactions in NRC implanted tissue, respectively. In NRC group, von-Kossa staining showed more calcification materials than MTA group at eighth wk. Conclusions: It was concluded that the calcium reservoir capability of NRC may contribute to mineralization of the tissues.

Horary System of the Early Chosen and the King Sejong′s Striking Clepsydra : (1) Water-Clocks (조선초기의 시제와 세종의 자격루:(1) 물시계)

  • 남문현;한득영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.697-701
    • /
    • 1996
  • King Sejong's Striking water-clock which brought in use on the first of July in 1434 was mainly composed of timekeeping and time announcing parts signalling twelve double-hours, and five night-watches and night-watch-divisions automatically by means of ball-operating jackworks. The clock was arranged with dual timekeeping system, the one for a full day(twelve double-hours) and the other for five night-watches achieving twelve double-hours and one-hundred interval horary systems. The vessels were arrayed in inflow-type water-clock, a large reservoir on the highest story, a constant-level tank for supplying water to the measuring vessel evenly in the middle, and the lowest tank to receive water from the above constant-level tank. An indicator-rod on the float was raised upwards depending on the water-level increase to show timing scales and also to release small bronze balls from the ball-rack mechanisms implanted on the measuring vessel to signal timing intervals.

  • PDF

Estimation of Reservoir Inflow Using Frequency Analysis (빈도분석에 의한 저수지 유입량 산정)

  • Maeng, Seung-Jin;Hwang, Ju-Ha;Shi, Qiang
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.3
    • /
    • pp.53-62
    • /
    • 2009
  • This study was carried out to select optimal probability distribution based on design accumulated monthly mean inflow from the viewpoint of drought by Gamma (GAM), Generalized extreme value (GEV), Generalized logistic (GLO), Generalized normal (GNO), Generalized pareto (GPA), Gumbel (GUM), Normal (NOR), Pearson type 3 (PT3), Wakeby (WAK) and Kappa (KAP) distributions for the observed accumulative monthly mean inflow of Chungjudam. L-moment ratio was calculated using observed accumulative monthly mean inflow. Parameters of 10 probability distributions were estimated by the method of L-moments with the observed accumulated monthly mean inflow. Design accumulated monthly mean inflows obtained by the method of L-moments using different methods for plotting positions formulas in the 10 probability distributions were compared by relative mean error (RME) and relative absolute error (RAE) respectively. It has shown that the design accumulative monthly mean inflow derived by the method of L-moments using Weibull plotting position formula in WAK and KAP distributions were much closer to those of the observed accumulative monthly mean inflow in comparison with those obtained by the method of L-moment with the different formulas for plotting positions in other distributions from the viewpoint of RME and RAE.

Effect of a Butterfly Valve on the Uncertainty of Flow Rate Measurement (버터플라이 밸브의 유량측정 불확도에 대한 영향)

  • Yoon, Seok-Ho;Lee, Jung-Ho;Yu, Cheong-Hwan;Park, Sang-Jin;Chung, Chang-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.18-24
    • /
    • 2010
  • For testing large-capacity pumps, the accurate flow rate measurement is needed in the test loop. As a measuring method of flow rate, venturi tube is recommended due to its low pressure loss. However, upstream disturbance of loop component such as a valve has an effect upon the accuracy of flow rate measurement. For controlling flow rate in case of high flow rate and large-scale piping system, a butterfly-type valve is generally used due to its compactness. However, a butterfly valve disturbs downstream flow by generating turbulence, cavities, or abrupt pressure change. In this study, the effect of downstream disturbance of butterfly valve on the flow rate measurement using a venturi tube is investigated. Test loop consists of circulation pump, reservoir, butterfly valve, venturi tube, and reference flow meter. The test is conducted with regard to a different valve opening angle of butterfly valve. According to the valve opening angle, the uncertainty of flow rate measurement is investigated.

The Study on the Simple Measurement by Using the Strain Gauge at Dam Dynamic Behavior Analysis (댐 거동 분석에서의 Strain Gauge를 이용한 단일 계측에 관한 연구)

  • Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.1
    • /
    • pp.5-11
    • /
    • 2007
  • Internal stress variation in the face slab concrete induced by reservoir water pressure may affect on the stability of the dam so that the reclamation type of strain gauge is applied for measuring internal stress variation. In this study, internal as well as external stress variation of dam was measured by using strain gauge that was reclaimed to the ${\circ}{\circ}$ dam. In the result, it was confirmed that other measurements by relevant gauges need to be supplemented as the use of strain gauge only is insufficient to evaluate the stability analysis and global behavior of the dam.

  • PDF

Study on Magnetic Separation of Hot Roller coolant by Using Superconducting HGMS (초전도 HGMS를 이용한 열연 냉각수의 자기분리 연구)

  • Ha, Dong-Woo;Kim, Tae-Hyung;Oh, Sang-Soo;Park, Sung-Kook;Lee, Sang-Gil;Roh, Yu-Mi
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.37-38
    • /
    • 2007
  • It needs several large reservoirs and long time to remove suspended solid like steel fines and iron oxide in hot rolling coolant. If removing rate of suspended solid in rolling coolant is improved by using high gradient magnetic separation (HGMS) system, the productivity of working process can be increased and the area of reservoir can be reduced. Pre-treatment process that react magnetic floc with inorganic and organic flocculant in coolant was studied. Horizontal type superconducting HGMS system was manufactured successfully, which was constituted with automatic filter transportation apparatus, 6 T He-free superconducting magnet system and water circulation system. The solid suspension removal ratio in hot rolling coolant was increased by flocculation with inorganic and organic flocculant.

  • PDF

High-rate Removal of Algae by Using of Filtration System with Coagulant Addition (응집과 여과를 이용한 조류의 초고속 제어에 관한 연구)

  • Yun, Sang Leen;Kim, Dong Ha;Rhee, Young Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.221-228
    • /
    • 2002
  • Abundant growth of algae in raw water sources caused by eutrophication brings about significant side effects on water supply, such as taste and order problem, oxygen depletion, toxic material secretion, and filter clogging problem in water treatment process, etc. The purpose of this research is to remove the algae and phosphorus compounds in the Pal-dang reservoir promptly by using the upflow filtration system with coagulant addition. The filter tower consisted of sand media and sieve filter with air back-washing process. By using coagulation and filtration with $132{\mu}m$ pore size filter, about 55% and 70% of algae and phosphorus compounds were removed respectively. The experimental conditions were as follows; head loss of 0.2m, linear velocity of 200m/day, and filtration flux of 1000($L/m^2/day$). In the case of filtration with cartridge type filter of $25{\mu}m$ pore size, the filtration flux was about 7800 LMH, and the removal ratios of COD, SS, T-P, and Chlo-a. were 61%, 99%, 54%, and 98%, respectively. However, high pressure air back-washing process with should be required for the maintenance of such high filtration flux.