• 제목/요약/키워드: Reservoir Tank

검색결과 88건 처리시간 0.027초

관개용 저수지의 일별유입량과 방류량의 모의발생(I)-선형 저수지 모형에 의한 유입량의 추정- (Simulating Daily Inflow and Release Rates for Irrigation Reservoirs (1) -Modeling Inflow Rates by A Linear Reservoir Model-)

  • 김현영;박승우
    • 한국농공학회지
    • /
    • 제30권1호
    • /
    • pp.50-62
    • /
    • 1988
  • This study refers to the development of a hydrologic model simulating daily inflow and release rates for irrigation reservoirs. A daily - based model is needed for adequate operation of an irrigation reservoir sufficing the water demand for paddy fields which is closely related to meteorological conditions. Inflow rates to a reservoir need to be accurately described, which may be simulated using a hydrologic model from daily rainfall data. And the objective of this paper is to develop, test, and apply a hydrologic model for daily runoff simmulation. A well - known tank model was selected and modified to simulate daily inflow rates. The model parameters were calibrated using observed runoff data from twelve watersheds, Relationships between the parameters and the watershed characteristics were derived by a multiple regression analysis. The simulation results were in agreement with the data. The inflow model was found to simulate low flow conditions more accurately than high flow conditions, which may be adequate for water resources utilization.

  • PDF

저온 태양열을 이용한 생물학적 오수 처리 장치 실증 실험 (Field Test for a Biological Nitrogen Treatment System with Low Temperature Solar Thermal Energy)

  • 정모;이동원
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.34-41
    • /
    • 2008
  • A low-temperature solar thermal system assisting a biological nitrogen treatment reservoir was designed and field-tested. A large tank whose temperature was maintained at about $25-30^{\circ}C$ to enhance the performance of a biological nitrogen treatment process was heated by an array of flat plate solar collectors. Test results revealed that the overall collector efficiency was above 50% for the most cases tested. This high efficiency was possible owing to the relatively low collector temperature that can be traced back to the reservoir temperature. A substantial enhancement in nitrogen treatment was observed as a result of maintaining the reservoir temperature higher.

저온 태양열 이용 생물학적 오수 처리 (Biological Waste Water Treatment with Solar Thermal Energy)

  • 정모;이동원;김정배;윤응상;변무룡;변무원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.559-562
    • /
    • 2006
  • A low-temperature solar thermal system assisting a biological nitrogen treatment reservoir was designed and field-tested. A large tank whose temperature was maintained at about $25{\sim}30^{\circ}C$ to enhance the performance of a biological nitrogen treatment process was heated by an array of flat plate solar collectors. Test results revealed that the overall collector efficiency was above 50% for the most cases tested. This high efficiency was possible owing to the relatively low collector temperature that can be traced back to the reservoir temperature. A substantial enhancement in nitrogen treatment was observed as a result of maintaining the reservoir temperature higher.

  • PDF

하천형 호수인 팔당호의 인 수지 (Phosphorus Budget of a River Reservoir, Paldang)

  • 공동수
    • 한국물환경학회지
    • /
    • 제34권3호
    • /
    • pp.270-284
    • /
    • 2018
  • Paldang is a river reservoir located in the Midwest of Korea, with a water volume of $244{\cdot}10^6m^3$ and a water surface area of $36.5km^2$. It has eutrophied since the construction of a dam at the end of 1973, and the phosphorus concentration has decreased since 2001. Average hydraulic residence time of the Paldang reservoir is about 10 days during the spring season and 5.6 days as an annual level. The hydraulics and water quality of the reservoir can differ greatly, both temporally and spatially. For the spring period (March to May) in 2001 ~ 2017, the reservoir mean total phosphorus concentration calculated from the budget model based on a plug-flow system (PF) and a continuous stirred-tank reaction system (CSTR) was 13 % higher and 10 % lower than the observed concentration, respectively. A composite flow system (CF) was devised by assuming that the transition zone was plug flow, and that the lacustrine zone was completely mixed. The mean concentration calculated from the model based on CF was not skewed from the observed concentration, and showed just 6 % error. The retention coefficient of the phosphorus derived from the CF was 0.30, which was less than those of the natural lakes abroad or river reservoirs in Korea. The apparent settling velocity of total phosphorus was estimated to be $93m\;yr^{-1}$, which was 6 ~ 9 times higher than those of foreign natural lakes. Assuming CF, the critical load line for the total phosphorus concentration showed a hyperbolic relation to the hydraulic load in the Paldang reservoir. This is different from the previously known straight critical load line. The trophic state of the Paldang reservoir has recently been estimated to be mesotrophic based on the critical-load curve of the phosphorus budget model developed in this study. Although there is no theoretical error in the newly developed budget model, it is necessary to verify the validity of the portion below the inflection point of the critical-load curve afterwards.

탱크 모델에 의한 홍수(洪水) 유출량(流出量) 해석(解析)에 관(關)한 연구(硏究) (A study on the flood runoff analysis with TANK MODEL)

  • 홍창선;최한규
    • 산업기술연구
    • /
    • 제3권
    • /
    • pp.95-101
    • /
    • 1983
  • This study aims at the determination of the coefficienties of runoff and infiltration affecting runoff. The rating curve is more available than the peak flood runoff to determine flood control plan of flood control reservoir and the volume of hydroelectric power plant, or to make multipurpose dam. In hydrologic analysis and design, it is necessary to develop relations between precipitation and runoff, possible using some of the factors affecting runoff as parameters. In order to calculate the runoff discharge, the runoff process constituting elements are divided to the surface runoff, the subsurface runoff and the groundwater runoff. By comparing the computed hydrograph with the measured hydrograph, determinned the watershed TANK Model constant Varying the tank model constant for approximating the computed hydrograph to the measured hydrograph.

  • PDF

농업용 저수지 용수공급 모의 시스템의 개발 (Development of agricultural reservoir water supply simulation system)

  • 전상민;강문성;송인홍;송정헌;박지훈;기우석
    • 농촌계획
    • /
    • 제20권2호
    • /
    • pp.103-114
    • /
    • 2014
  • The objective of this study was to develop agricultural reservoir water supply simulation system to assess water cycle of agricultural water district. Developed system was named as ARWS (Agricultural Reservoir Water supply simulation System). ARWS consists of platform and independent modules. In ARWS, reservoir inflow was calculated using Tank model, and agricultural water supply was calculated considering current farming period and mid-summer drainage. ARWS was applied to simulate water level of Gopung and Tapjung reservoir in 2011 - 2012. The results were compared to simulation results of HOMWRS and observed data. Average $R^2$, EI, RMSE of ARWS were 0.76, 0.46, 1.78 (m), average $R^2$, EI, RMSE of HOMRWS were 0.88, -0.14, 2.37 (m) respectively. Considering statistical variances, water level simulation results of ARWS were more similar to observed data than HOMWRS. ARWS can be useful to estimate reservoir water supply and assess hydrological processes of agricultural water district.

소규모 농업용 저수지의 저류량-용수공급능력 결정에 관한 연구 (A Study on the Determination of Water Storage-Supply Capacity of Agricultural Reservoir)

  • 안승섭;정순돌;이증석;윤경덕;장인수
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1217-1226
    • /
    • 2002
  • This study aims at the effective estimation of water supply capacity of small scale reservoir and the proposal of the data which is necessary to establish the water resources management plan of down stream area of the reservoir in the future by comparison and examination about reservoir operation technique for the security of agricultural water in small scale reservoir. The result of flow calculation by Tank model is used for the input data as the inflow data which is needed for the analysis of water supply capacity. Stochastic method, simulation method, and optimization method are used to examine the water supply capacity, and water security amount is compared with each method. From the analyses of water supply capacities by each method, slightly different results are shown in spite of the effort to compare them equally using input data such as inflow data under equal conditions, and the comparison of water supply capacities by each method are as follows; linear planning method, simulation method, and transition probability matrix method in the order of amount from the largest. It is thought that the simulation method in which comparatively reasonable application of the inflow data is possible and is simulated in successive time series dam operation of the three methods used in this study thus, simulation model is proper to estimate the water supply capacity of agricultural small scale reservoir. And it is judged that the heightening of efficiency of water resources utilization according to the development of downstream area of dam may be possible using the upward readjusted water supply amount of $55.18{\tiems}10^6ton$ and $63.7{\times}10^6ton$ at 95% and 90% supply reliability respectively which are above the planning water supply amount of $50.0{\times}10^6$ton when the simulation method is introduced as the standard.

실시간 관측 및 제어가 가능한 IoT 저수조 관리 시스템 (IoT-based Water Tank Management System for Real-time Monitoring and Controling)

  • 권민서;김우주;이재준;조오현
    • 융합정보논문지
    • /
    • 제8권6호
    • /
    • pp.217-223
    • /
    • 2018
  • 실시간 제어는 관리 시스템의 실질적인 사용을 확인하기 위해 해결해야 하는 주요 과제였다. 이와 관련하여 편의성과 효율성을 높이기 위해 처음으로 사물인터넷(IoT) 기반 저수조 시스템을 제안 및 개발하였다. 저수조의 상태가 불안정할 경우 사용자에게 알려 저수조를 효과적으로 제어할 수 있다. 제안된 시스템은 센서 데이터 측정 및 제어를 위한 내장형 H/W 장치, 웹 및 모바일 앱을 통한 관리 서버 구축을 위한 애플리케이션 S/W, 통계 관리 및 모니터링을 위한 효율적인 데이터베이스 구조로 구성되어 있다. 또한 기계 학습 알고리즘을 적용하여 실제 효율성을 더욱 향상시킬 수 있다.

원수열원 히트펌프 축열시스템의 동절기 성능분석 (Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

COMFARM을 이용한 농업용저수지 유역 수문 모델링 (Hydrologic Modeling for Agricultural Reservoir Watersheds Using the COMFARM)

  • 송정헌;박지훈;김계웅;류정훈;전상민;김진택;장태일;송인홍;강문성
    • 한국농공학회논문집
    • /
    • 제58권3호
    • /
    • pp.71-80
    • /
    • 2016
  • The component-based modeling framework for agricultural water-resources management (COMFARM) is a user-friendly, highly interoperable, lightweight modeling framework that supports the development of watershed-specific domain components. The objective of this study was to evaluate the suitability of the COMFARM for the design and creation of a component-based modeling system of agricultural reservoir watersheds. A case study that focused on a particular modeling system was conducted on a watershed that includes the Daehwa and Dangwol serial irrigation reservoirs. The hydrologic modeling system for the study area was constructed with linkable components, including the modified Tank, an agricultural water supply and drainage model, and a reservoir water balance model. The model parameters were each calibrated for two years, based on observed reservoir water levels. The simulated results were in good agreement with the observed data. In addition, the applicability of the COMFARM was evaluated for regions where reservoir outflows, including not only spillway release but also return flow by irrigation water supply, substantially affect the downstream river discharge. The COMFARM could help to develop effective water-management measures by allowing the construction of a modeling system and evaluation of multiple operational scenarios customized for a specific watershed.