• Title/Summary/Keyword: Reservoir Tank

Search Result 88, Processing Time 0.019 seconds

Optimal Reservoir Operation Models for Paddy Rice Irrigation with Weather Forecasts(Ill) -Model Application- (기상예보를 고려한 관개용 저수지의 최적 조작 모형(III) -모형의 적용-)

  • 김병진;박승우;정하우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.3
    • /
    • pp.47-59
    • /
    • 1994
  • The irrigation reservoir operation models developed were tested with weather and field data, and the sensitivity of the water requirement deficiency indices(WRDI) were checked with different initial reservoir storages, irrigated areas, and other water uses from the reservoir storage. Seven reservoir release rules were applied to Yongseol Reservoir. Twenty year WRDIs were computed to check performances of those reservoir release rules. Mean WRDIs were 138, 198, 198, 200, 240, 344, and 1033mm for ROM, TOS, COS, CRR, MSC, FAS, and SRC, respectively. The results indicated that ROM contributes consistently to higher operation efficiencies of an irrigation reservoir. The test results of LFROM and SFROM showed that reservoir operation with the proposed optimization technique ROM would be better suited for an irrigation district than those with the other rules. And the proposed model could be used as a tool to improve reservoir operations.

  • PDF

Reduction of Rainfall Runoff by Constructing Underground Storage Tank (지하저류조 신설에 따른 우수 유출량 저감)

  • Song, Chang Geun;Seo, Il Won;Jung, Young Jai
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.927-935
    • /
    • 2013
  • In this study, reservoir routings for 1 hour-50 year precipitation frequency were carried out at the Engineering Water Fall and the Amphitheater located at the downstream of Seoul National University Dam. Main analysis was focus on the following matters: (1) storage amount by the tank; (2) reduction of the outflow and the peak water surface elevation; (3) change of phase lag time; and (4) design of new boxes at the inlet and outlet of storage tank. As for the storage tank of $25,000m^3$ built in the Amphitheater area, the tank induced 49.43 % storage effect, 28 min. phase lag time, and reduced the peak outflow by 49.64 %. In addition, the peak water surface elevation was lowered by 35 cm compared with that of $15,000m^3$ storage tank. It is concluded that combined management of previous storage facility and new underground storage tank would control the excessive rainfall runoff efficiently.

Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment (공동주택 지하저수조의 수질변화 및 부식성 특성)

  • JunYoung, Jang;JooWon, Kim;YuHoon, Hwang;KiPal, Kim;HyunSang, Shin;ByungRan, Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.

Optimization of Storage Tank Installation Locations for Pipeline Water Supply Using Genetic Algorithm (유전자 알고리즘을 이용한 관수 저류조의 공간배치 최적화)

  • Hong, Rokgi;Park, Jinseok;Jang, Seongju;Lee, Hyeokjin;Song, Inhong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.43-53
    • /
    • 2022
  • Rice paddy has been actively converted into upland crop fields as more profitable upland crop cultivation are encouraged along with the decrease in rice consumption. However, the current water supply system remains mainly for paddy water supply, so research on pipeline water supply for upland cultivation is needed. The objective of this study was to optimize storage tank installation locations for pipeline water supply in reservoir irrigation districts. Five of reservoir irrigation districts were selected as the study sites and gridded of 10×10 m in size. Then genetic algorithm was adopted to evaluate the effects of spatial storage tank allocation on total pipeline cost. The lengths of the main and branch pipelines were considered as the objective cost function for the optimization of storage tank installation. Overall the shorter the branch pipeline and the longer the main pipeline, as the number of storage tanks increase. The minimal pipeline cost, i.e., optimal condition was reached when approximately 10% of the storage tank numbers to total upland plots were installed. The methodology presented in this study can be applied to determine the number and spatial arrangement of storage tanks for upland pipeline irrigation system design.

Analysis of Water Storage Tank Flowfield using Computational Fluid Dynamics (CFD) Simulation (전산유체역학(CFD)을 이용한 저수조 내부 유동장 해석)

  • Choi, Yeon-Woo;Han, Min-Su;Song, Jun-Hyuck;Wang, Chang-Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.173-182
    • /
    • 2018
  • Reservoirs, facilities to store water, are being used in several fields for their ability to hold back a large quantity of water for a long time before the water is actually used. However, at the same time, the reservoirs are considered to have a flaw: the longer they store water, the more the quality of water in these reservoirs deteriorates. Further, when the reservoirs are large, they are more likely to have dead-water regions in out-of-the way spots far from either an in-current or an ex-current canal. This study conducted a Computational Fluid Dynamic (CFD) simulation and tried to figure out the internal flow inside each of the reservoirs with different in-current canals built by the multiple hoe screw nozzle method and the drop in-current method. The drop in-current method is more frequently used. According to the analysis of the internal flow inside each reservoir with the different methods applied, we found that the reservoir with the drop in-current canal would have two rotary currents in the lower region of the reservoir and that the velocity of flow would decrease. For a reservoir with the screw nozzle method, a single rotary current occurred, and inside the reservoir, regardless of height, the current turned out to flow in a regular manner.

Parameter Regionalization of a Tank Model for Simulating Runoffs from Ungauged Watersheds (미계측 유역 유출 모의를 위한 Tank 모형의 매개변수 지역화)

  • Kang, Min Goo;Lee, Joo Heon;Park, Ki Wook
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.5
    • /
    • pp.519-530
    • /
    • 2013
  • To provide a reliable tool for runoff simulations of ungauged watersheds upstream of reservoirs, a daily runoff simulation model, Tank model, is restructured, the parameter regionalization of the model is conducted, and the model's applicability is evaluated. Taking into account the characteristics of runoffs from the watersheds, a three-tank model is employed. The percolation process of the model's third tank is eliminated, considering the water budgets of the watersheds, and its evapotranspiration component is improved, reflecting the conditions of meteorological observation in South Korea. The sensitivity analysis of the model shows that the model's behaviors, varying with a sensitive parameter, ${\alpha}$, are reasonable. The regional parameter estimation equations are determined, using the characteristics and land uses of the watersheds as variables. The model is applied for the runoff simulations of three watersheds and the water stage simulation of one reservoir, and the simulation results are then compared with the observed values, which prove to be in close agreement with the observations. In addition, the results from simulating inflows of twenty-four reservoirs using the model show that the averages of evapotranspiration rate and runoff rate are 42.8% and 56.6%, respectively, which are resonable. Consequently, it is concluded that the model is practically applicable to simulating runoffs from watersheds upstream of reservoirs, and simulated inflow data are useful for watershed management and reservoir planning, design, and operation.

An Evaluatiou of Parameter Variations for a Linear Reservoir (TANK) Model with Watershed Characteristics (유역특성에 따른 탱크모형 매개변수의 변화)

  • 김현영;박승우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.2
    • /
    • pp.42-52
    • /
    • 1986
  • This study involves the estimation of optimal ranges of parameters for a linear watershed model. A well-known TANK model was chosen and a linear combination of four tanks assumed. The model was used to simulate daily streamflow for six watersheds of different sizes and by a trial-and-error approach a set of optimal parameters defined. The parameters were related to watershed sizes and land use conditions. Optimal parameters for ungaged conditions were defined from the relationships; daily streamflow simulated and compared to the observed date. The simulated results were in a general agreement with the data.

  • PDF

Water Balance Analysis of Pumped-Storage Reservoir during Non-Irrigation Period for Recurrent Irrigation Water Management (순환형 농업용수관리를 위한 농업용 저수지의 비관개기 양수저류 추정)

  • Bang, Na-Kyoung;Nam, Won-Ho;Shin, Ji-Hyeon;Kim, Han-Joong;Kang, Ku;Baek, Seung-Chool;Lee, Kwang-Ya
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.1-12
    • /
    • 2020
  • The extreme 2017 spring drought affected a large portion of South Korea in the Southern Gyeonggi-do and Chungcheongnam-do districts. This drought event was one of the climatologically driest spring seasons over the 1961-2016 period of record. It was characterized by exceptionally low reservoir water levels, with the average water level being 36% lower over most of western South Korea. In this study, we consider drought response methods to alleviate the shortage of agricultural water in times of drought. It could be to store water from a stream into a reservoir. There is a cyclical method for reusing water supplied from a reservoir into streams through drainage. We intended to present a decision-making plan for water supply based on the calculation of the quantity of water supply and leakage. We compared the rainfall-runoff equation with the TANK model, which is a long-term run-off model. Estimations of reservoir inflow during non-irrigation seasons applied to the Madun, Daesa, and Pungjeon reservoirs. We applied the run-off flow to the last 30 years of rainfall data to estimate reservoir storage. We calculated the available water in the river during the non-irrigation season. The daily average inflow from 2003 to 2018 was calculated from October to April. Simulation results show that an average of 67,000 tons of water is obtained during the non-irrigation season. The report shows that about 53,000 tons of water are available except during the winter season from December to February. The Madun Reservoir began in early October with a 10 percent storage rate. In the starting ratio, a simulated rate of 4 K, 6 K, and 8 K tons is predicted to be 44%, 50%, and 60%. We can estimate the amount of water needed and the timing of water pump operations during the non-irrigation season that focuses on fresh water reservoirs and improve decision making for efficient water supplies.

Impact of the Geochemical Characteristics and Potential Contaminants Source of Surrounding Soil on Contamination of a Reservoir in an Island (II) - Appraisal of flow categorized by Incursion Using Rainfall-Runoff Model - (주변토양의 지구화학적 특성과 잠재적 오염원이 도서지역 저수지의 오염부하에 미치는 영향(II) - 강우 유출 모형을 이용한 유입경로별 유출량 평가 -)

  • Park, Sun-Hwan;Park, Wan-Sub;Jun, Young-Bong;Kim, Chang-Gyun;Kim, Sung-Gou;Kang, Seon-Hong;Chang, Yoon-Young;Jeong, Jeong-Ho;Jung, Jong-Ahm
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • This research aims to gain the result of assessment of inflow categorized by runoff path using DIROM (Daily Irrigation Reservoir Operation Model) for Baengnyeong-myeon reservior which was built for residents of Baengnyeong island to solve the shortage of drinking water and stable supply of domestic water. The simulation results of DIROM and actual hydrograph of the reservoir show very low correlation with geological characteristics. The simulation results by DIROM after adjusting with modified Tank III model which considers all outflow from Tank II model as interflow among 3 level tanks show good correlation of its regional runoff and inflow characteristics with $R^2$=0.9058. In the study area, diffluence of 37% of rain fall of the study year has been simulated, which shows low result compared to the average river runoff of national water resource. In addition, 34.5% of total inflow to the study reservoir is mainly interflow and baseflow among expected several channels.

Flood Effects Analysis of Reservoir Basin through the Linkage of HEC-HMS and HEC-RAS Models (HEC-HMS와 HEC-RAS모형의 연계에 의한 댐 유역의 홍수영향 분석)

  • Lee, Weon-Hee;Kim , Sun-Joo;Kim , Phil-Shik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.2
    • /
    • pp.15-25
    • /
    • 2004
  • For the effective operation of irrigation reservoirs, a general and systematic policy is suggested to make balance of the conflicting purposes between water conservation and flood control. In this study, the flood effective analysis system was developed through the integration of long-term water budget analysis model, GIS-based HEC-HMS model and HEC-RAS model. The system structure consists of long-term water budget model using modified TANK theory, flood runoff and flood effects analysis model using HEC-GeoHMS, HEC-HMS and HEC-RAS models. The flood effects analysis system simulated the flood runoff from the upstream, downstream flood and long-term runoff of the watershed using the observed data collected from 1998 to 2002 of Seongju dam. The simulated results were reasonably good compared with the observed data. The optimal management method of the reservoir during the whole season is suggested in this study, and the flood analysis system can be a useful tool to evaluate a reservoir operation quantitatively for the mitigation of flood damages of reservoir basin.