• Title/Summary/Keyword: Research efficiency

Search Result 17,322, Processing Time 0.048 seconds

Performance and reusability of certified and uncertified face masks (보건용 마스크 초미세먼지 제거 성능 평가 및 재사용 연구)

  • Lee, Haebum;Kim, Seojeong;Joo, HungSoo;Cho, Hee-joo;Park, Kihong
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.191-202
    • /
    • 2019
  • In this study, performance (particle removal efficiency and breathing resistance) of several commercially available face masks (electrostatic filter masks (KF80 certified), a nanofiber filter mask (KF80 certified), and an uncertified mask) with their filter structure and composition were evaluated. Also, effects of relative humidity (RH) of incoming air, water and alcohol exposure, and reusability on performance of face masks were examined. Monodisperse and polydisperse sodium chloride particles were used as test aerosols. Except the uncertified mask filter, PM2.5 removal efficiency was found to be higher than 90%, and the nanofiber filter mask had the highest quality factor due to the low pressure drop and high removal efficiency (nanofibers were arranged in a densely packed pore structure and contained a significant amount of fluorine in addition to carbon and oxygen). In the case of the KF80 certified mask, the removal efficiency was little affected when the RH of incoming air increased. When the mask filters were soaked in water, the removal efficiency of mask filters was degraded. In particular, the uncertified mask filter showed the highest removal efficiency degradation (26%). When the mask was soaked in alcohol, the removal efficiency also decreased with the greater degree than the water soaking case. The nanofiber mask filter showed the strongest resistance to alcohol exposure among tested mask filters. During evaluation of reusability of masks in real life, the removal efficiency of certified mask filter was less than 4% for 5 consecutive days (2 hours per day), while the removal efficiency of uncertified mask filter significantly decreased by 30% after 5 days.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

Bright and Efficient Electrophosphorescence from Polymer Based LED

  • Xie, Zhiliang;Qiu, Chengfeng;Peng, Huajun;Chen, Haiying;Wong, Man;Tang, Ben Zhong;Kwok, Hoi Sing
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.984-987
    • /
    • 2003
  • The electrophosphorescent emission properties were investigated in polymer light-emitting diodes (PLEDs) based on a poly(9-vinylcarbazole) (PVK) doped with a green phosphorescent dye of fac-tris(2-phenylpyridine) iridium (III) [$Ir(ppy)_3$]. A green light peaked at 516 nm was emitted from devices with a configuration of ITO/PEDOT:PSS/PVK:$Ir(ppy)_{3}$/BCP/$Alq_{3}$/LiF/Al. The optimal doping concentration of $Ir(ppy)_{3}$ in PVK was found at 2% by weight, under which maximum current efficiency of 24.3 cd/A and peak external quantum efficiency of 6.8% were achieved at the high luminance of 4240 $cd/m^{2}$. The external quantum efficiency of 5% and current efficiency of 18 cd/A can be sustained even at the very high luminance of 35000 $cd/m^{2}$.

  • PDF

Evaluation of Removal Efficiency of Water Contents using Inertial Impaction Separator (관성 충돌 방식의 액적 분리장치의 수분제거효율 평가)

  • Lee, Sin Young;Hong, Won Seok;Shin, Wanho;Kim, Gyujin;Song, Dong Keun
    • Particle and aerosol research
    • /
    • v.9 no.1
    • /
    • pp.23-29
    • /
    • 2013
  • Inertial impaction type mist eliminators are the most effective instruments to separate mist from the gas. In this work, the effect of the horizontal chevron type mist eliminators is characterized experimentally. Droplet size distribution and evaluation of removal efficiency of the chevron type mist eliminators at different gas flows were investigated using an aerosol particle size analyzer and a portable aerosol spectrometer, respectively. The experimental investigations showed that the mist removal efficiency in these instruments is dependent in the droplet size, and the pressure drop is nil.

Heating Energy Saving and Cost Benefit Analysis According to Low-Income Energy Efficiency Treatment Program - Case Study for Low-Income Detached Houses Energy Efficiency Treatment Program (저소득층 에너지효율개선사업에 따른 난방에너지 절감 효과 및 경제성 분석 - 저소득층 단독주택 단열개선을 중심으로 -)

  • Kim, Jeong-Gook;Lee, Junghun;Jang, Cheolyong;Song, Doosam;Yoo, Seunghwan;Kim, Jonghun
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.39-45
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the energy saving and cost benefit analysis of the Low-income Energy Efficiency Treatment Program supported by KOREF(Korea Energy Foundation). This program was launched in 2007 and performs building energy retrofit for the low-income and energy poverty houses. Method: Energy simulation and cost benefit analysis were accomplished for the low-income detached houses. The structure of detached house was a lot og block structure, wood frame (single glass) and concrete roof. Baseline model of the low-income detached houses was proposed. Result: Annual heating energy consumptions were decreased by about 3.2% with the window system replacement(Case 1), 9.3% with reinforcement of insulation(Case2), and 12.5% with both(Case 3) compared to those of baseline model. The construction cost will be recouped within 5 years for the Case 1, 3 years for the Case 2, and 3 years for the Case 3. Case 3 was the most cost beneficient construction method in the analyzed cases in this study.

Physiological Analysis of Freestyle and Breast Stroke Swimming in High School Boys (산소 섭취량을 통하여 관찰한 수영의 생리학적 분석)

  • Nam, Kee-Yong;Kwon, Seung-Rak;Cho, Yoon-Sik;Kim, Yoon-Sun;Kim, Dai-Sung;Kim, Young-Tai
    • The Korean Journal of Physiology
    • /
    • v.3 no.2
    • /
    • pp.1-7
    • /
    • 1969
  • Physiological analysis of swimming in 13 (age:16.3 years, freestyle swimming) and 15 (age:17.2 years, breast stroke swimming) high school boys through oxygen uptake and oxygen debt measurements were performed. The following results were obtained. 1. In freestyle swimming oxygen debt was greater and mechanical efficiency was lower in subjects with less speed. In beginner efficiency was only 1.35%, whereas, in a more skilled subject it ranged to 4.28%. The mean efficiency was 2.59%. 2. In freestyle swimming the speed-oxygen debt curve was convex to the speed axis and the curve shifted to the right the more the speed was greater. 3. Maximal oxygen uptake in breast stroke swimming was 2.51 l/min or 41.8 ml/kin/kg and was 79.3% of treadmill running. Maximal pulmonary ventilation in breast stroke swimming was 73.1 l/min and was 87% of treadmill running. Maximal ventilation equivalent was 2.89 liters. 4. In subjects with greater speed of breast stroke swimming maximal oxygen uptake and mechanical efficiency of swimming were greater. The mechanical efficiency of breast stroke swimming averaged 1.08% $(range:0.51{\sim}1.70%)$. The coefficient of correlation between speed and efficiency was r=.87.

  • PDF

Design and analysis of a free-piston stirling engine for space nuclear power reactor

  • Dai, Zhiwen;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.637-646
    • /
    • 2021
  • The free-piston Stirling engine (FPSE) has been widely used in aerospace owing to its advantages of high efficiency, high reliability, and self-starting ability. In this paper, a 20-kW FPSE is proposed by analyzing the requirements of space nuclear power reactor. A code was developed based on an improved simple analysis method to evaluate the performance of the proposed FPSE. The code is benchmarked with experimental data, and the maximum relative error of the output power is 17.1%. Numerical results show that the output power is 21 kW, which satisfies the design requirements. The results show that: a) reducing the pressure shell's thickness can improve the output power significantly; b) the system efficiency increases with the wire porosity, while the growth of system efficiency decreases when the porosity is higher than 80%, and system efficiency exhibits a linear relationship with the temperatures of the cold and hot sides; c) the system efficiency increases with the compression ratio; the compression ratio increases by 16.7% while the system efficiency increases by 42%. This study can provide valuable theoretical support for the design and analysis of FPSEs for space nuclear power reactors.

Research of Efficiency for Gas Electron Multiplier Detector to Monitor Low Energy Gamma-Ray and Beta-Ray (낮은 에너지 감마선과 베타선 모니터링을 위한 Gas Electron Multiplier 검출기의 효율성에 대한 연구)

  • Lee, Soonhyouk;Jung, Jae Hoon;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.95-99
    • /
    • 2014
  • Radiation monitoring is one of the most important process in all places where radioactive material is used including hospital. In this preliminary study, we made GAS electron multiplier (GEM) detector and acquired relative efficiencies in order to see if GEM detector can be useful in radiation monitoring system. The relative efficiency was acquired by using the ratio of GEM detector efficiency to CdTe detector efficiency. The relative efficiency of 72% and 4% was acquired for beta-ray and gamma-ray respectively.

High-Efficiency CMOS Power Amplifier Using Uneven Bias for Wireless LAN Application

  • Ryu, Namsik;Jung, Jae-Ho;Jeong, Yongchae
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.885-891
    • /
    • 2012
  • This paper proposes a high-efficiency power amplifier (PA) with uneven bias. The proposed amplifier consists of a driver amplifier, power stages of the main amplifier with class AB bias, and an auxiliary amplifier with class C bias. Unlike other CMOS PAs, the amplifier adopts a current-mode transformer-based combiner to reduce the output stage loss and size. As a result, the amplifier can improve the efficiency and reduce the quiescent current. The fully integrated CMOS PA is implemented using the commercial Taiwan Semiconductor Manufacturing Company 0.18-${\mu}m$ RF-CMOS process with a supply voltage of 3.3 V. The measured gain, $P_{1dB}$, and efficiency at $P_{1dB}$ are 29 dB, 28.1 dBm, and 37.9%, respectively. When the PA is tested with 54 Mbps of an 802.11g WLAN orthogonal frequency division multiplexing signal, a 25-dB error vector magnitude compliant output power of 22 dBm and a 21.5% efficiency can be obtained.

Removal Characteristics of Gaseous Contaminants by a Wet Scrubber with Different Packing Materials (충진제의 종류에 따른 습식 스크러버의 가스상 물질 제거특성)

  • Han, Bang-Woo;Kim, Hak-Joon;Kim, Yong-Jin;Han, Kyeong-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.744-751
    • /
    • 2007
  • Wet scrubber is widely used to remove toxic gaseous contaminants in various industries such as semi-conductor industry, display manufacturing industry and so on. In this study, to optimize a packed bed scrubber as one of typical wet scrubber size while keeping its performance, four different packing materials were investigated at different air flow rates, liquid-gas ratios and pH values. Ammonia, hydrochloric acid and hydrofluoric acid were used as test gases to characterize the scrubber performance. Gas removal efficiency increased as the packing size decreased, which resulted in the increase of specific surface area. The increase of air flow rate led to the decrease of gas removal efficiency, while the increase of liquid-gas ratio led to the increase of gas removal efficiency. For the case of $NH_3$ gas, lower pH, and for the cases of HCl and HF, higher pH contributed to higher gas removal efficiency. Gas removal efficiency of a wet scrubber increased in the order of HCl < $NH_3$ < HF according to its water solubility.