• Title/Summary/Keyword: Research Performance Evaluation

Search Result 5,513, Processing Time 0.047 seconds

Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1 (사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용)

  • Jung, Hwansuk;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.

Studies on the Manifestation of Hybrid vigour and Combining Ability in Polyvoltine X Bivoltine (cross breed) Hybrids of Mulberry Silkworm Bombyx mori L.

  • Seshagiri, S.V.;Naik, S. Sankar;Seetharamulu, J.;Goel, A.K.;Raju, P.J.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.24 no.1
    • /
    • pp.7-16
    • /
    • 2012
  • To meet the local requirement i.e. the tropical stress of Andhra Pradesh and marginal farmers, twenty four new hybrid combinations were tested in Line x Tester method involving eight newly developed polyvoltine oval lines viz., MSO1, MSO2, MSO3, MSO4, MSO5, MSO6, MSO7 and MSO8 and three bivoltine silkworm breeds viz., APS12, APS45 and APS8 as testers. These hybrids were reared to evaluate their performance. Data for eight economically important metric traits viz., fecundity, cocoon yield per 10,000 larvae by number, cocoon yield per 10,000 larvae by weight, survival rate, cocoon weight, cocoon shell weight, cocoon shell ratio and filament length was recorded. General combining ability (gca), specific combining ability (sca) and heterosis were analyzed. Further, the relative merit of the hybrids for all the traits under study was also assessed adopting Evaluation Index method. Based on combining ability effects, heterosis and evaluation index, five hybrid combinations viz., MSO3 $\times$ APS45, MSO1 $\times$ APS12, MSO7 $\times$ APS8, MSO2 $\times$ APS45 and MSO1 $\times$ APS45 were selected for further evaluation in different seasons.

Evaluation of Rapid filtration System with Particle Size Distribution and Turbidity in Different Effective Sizes

  • Park, J.A.;Eo, S.M.;Shin, J.S.;Kim, M.H.;Yu, M.J.;Chung, S.H.
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.381-385
    • /
    • 2005
  • Characterization of particle behavior is becoming more important in performance evaluation of water treatment system as well as in operation of the system because conventional parameter, turbidity has lack of explaining ability on small sized microorganisms such like Cryptosporidium etc. Accordingly, particle counter has been introduced in evaluation and operation of the treatment system. However researches on the relationship between turbidity, particle count and/or different sand/anthracite sizes have not been concurrent. Therefore in this study, the relationship was investigated to improve performance evaluation of sand filter so as to help choosing sand/anthracite effective size as a design parameter of water treatment facility. According to the results, too small or too large effective size media filter reached to turbidity limit(0.1 NTU)earlier. However, because shallow sand layer may cause early breakthrough, the depth of sand layer should be provided enough in order to compromise water quality and productivity.

  • PDF

Development of advanced rigorous two-step code system for evaluation of radioactive waste with high-resolution activation calculation

  • Kim, Do Hyun;Kim, Jiseok;Lee, Han Rim;Sun, Gwang Min;Shin, Chang Ho;Kim, Jong Kyung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.2011-2018
    • /
    • 2021
  • Nowadays, evaluation of amounts and distributions of radioactive waste is an important preparatory step in the process of nuclear reactor decommissioning. For tentative estimation of radioactive waste, a cell-based rigorous 2 step (R2S) method usually is used; however, a poor resolution caused by the averaged flux and spectrum in a cell is still a great challenge because of leading to underestimated or overestimated results. To overcome the poor resolution, several systems were introduced. Neither system, however, provides any function for evaluation of radioactive waste amount and distribution. Thus, it is additionally required to classify radioactive waste based on the results of activation calculation. In this study, the advanced R2S (AR2S) system was developed. To verify the performance of the system, its results for a verification problem were compared with those of the cell-based R2S method. The results showed good agreement, which is to say, within 2.0% relative error. Also, several characteristics of fine/coarse mesh were analyzed. To demonstrate the performance of the AR2S system, the radioactive waste from the Japan Power Demonstration Reactor (JPDR) was estimated, and the result indicated a high-resolution distribution. Therefore, it is expected that the AR2S system will prove useful for precise evaluation of radioactive waste.

Deriving Performance Evaluation Indicator of Program for Developing the Next Generation of Top Security Leaders (차세대 보안리더 양성프로그램의 성과평가 지표 개발)

  • Park, Sung-Kyu;Kim, Tae-Sung;Kim, Jin-Seog;Yu, Seong-Jae
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.2
    • /
    • pp.501-511
    • /
    • 2018
  • The purpose of this study is to develop the performance evaluation indicator of information security training program for developing the next generation of top security leaders. Through literature review and focus group interview, we derived the performance areas and indicators based on the logic model. We conducted AHP(Analytic Hierarchy Process) questionnaire to calculate the weight of the derived indicators, and developed the performance indicator based on the survey results. Performance indicators were composed of 18 indicators in four main categories.

Cooling and Heating Performance Evaluation of a GSHP System (지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가)

  • Sohn Byong Hu;Cho Chung-Sik;Shin Hyun-Jun;An Hyung-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.

Looking Beyond the Numbers: Bibliometric Approach to Analysis of LIS Research in Korea

  • Yang, Kiduk;Lee, Jongwook;Choi, Wonchan
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.49 no.4
    • /
    • pp.241-264
    • /
    • 2015
  • Bibliometric analysis for research performance evaluation can generate erroneous assessments for various reasons. Application of the same evaluation metric to different domains, for instance, can produce unfair evaluation results, while analysis based on incomplete data can lead to incorrect conclusions. This study examines bibliometric data of library and information science (LIS) research in Korea to investigate whether research performance should be evaluated in a uniform manner in multi-disciplinary fields such as LIS and how data incompleteness can affect the bibliometric assessment outcomes. The initial analysis of our study data, which consisted of 4,350 citations to 1,986 domestic papers published between 2001 and 2010 by 163 LIS faculty members in Korea, showed an anomalous citation pattern caused by data incompleteness, which was addressed via data projection based on past citation trends. The subsequent analysis of augmented study data revealed ample evidence of bibliometric pattern differences across subject areas. In addition to highlighting the need for a subject-specific assessment of research performance, the study demonstrated the importance of rigorous analysis and careful interpretation of bibliometric data by identifying and compensating for deficiencies in the data source, examining per capita as well as overall statistics, and considering various facets of research in order to interpret what the numbers reflect rather than merely taking them at face value as quantitative measures of research performance.

Study on Developing Assessment Tools for Architectural Engineering Program Outcomes - focused on the extra curriculum - (건축공학 프로그램의 학습성과 평가도구 개발에 관한 연구 - 비교과과정을 중심으로 -)

  • Kim, Tae-Keun;Lee, Dong-Jin;Lee, Yong-Kyu;Kim, Jae-Yeob
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.143-147
    • /
    • 2009
  • Graduates from engineering colleges are demanded to have been acquired some abilities and qualities during their undergraduate years through the standard of the so-called "programmed learning results and evaluation" This paper aims at analyzing the learning results evaluation tool for graduates from the architectural engineering department through the examples of the colleges with engineering accreditation in Korea, and suggesting a more appropriate programmed learning result evaluation tool. The basic theories on programmed learning results were studied, and then the previous study examples were researched. The study objects were limited to the fourteen colleges which offered the examples of the learning results evaluation tools of the colleges with engineering accreditation in Korea. Types and the present situation of those evaluation tools were analyzed. In addition, the proposals for the evaluation tool of programmed learning results and the performance standard were suggested for those with an engineering accreditation, based on the case study of the performance standards of each college with an engineering accreditation. The study results showed that much more national research needs to be conducted to clarify the standards of selecting an evaluation tool and a performance standard appropriate for the level of each college so that it can make a proper proposal.

  • PDF

A Risk Analysis Model Using VERT for R & D Project Management (R & D 프로젝트의 위험분석모형의 연구)

  • 황홍석
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.20 no.1
    • /
    • pp.85-99
    • /
    • 1995
  • Increasingly, risk analysis is becoming important ingredients in achieving the successful implementation and application in the area of the project management. The project management system is designed to manage or control the project resources on a given activity within time, cost and performance so called TPPM (Total Productive Project Management). In this research, a risk analysis model misproposed to identify potential problem areas, quantify the risks, and generated the chice of the action that can be taken to reduce the risk. In addition two analysis models are proposed : 1) risk factor model and 2) network simulation model using VERT (Venture Evaluation and Review Technique ). The objective of the remodels is to estimate the schedule, cost performance risks. These proposed quantitative models for project risk analysis are proving its value for the project managers who need to assess the risk of changes in cost, schedule, or performance. The proposed models will be used in the area of project selection, evaluation and the allocation of project resources.

  • PDF