The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF

Detection of HCV-RNA by Reverse Transcription Polymerase Chain Reaction Using Biotinylated and Radioiodinated Primers (역전사 중합효소 연쇄반응(RT-PCR)에 의한 HCV-RNA의 검출 : Biotin 및 방사성옥소 표지 Primer로 구성된 Kit의 이용)

  • Ryu, Jin-Sook;Moon, Dae-Hyuk;Cheon, Jun-Hong;Chung, Yoon-Young;Park, Hung-Dong;Chung, Young-Hwa;Lee, Young-Sang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.220-226
    • /
    • 1994
  • This study was performed to evaluate the clinical applicability of the reverse transcription polymerase chain reaction (RT-PCR ) kit of HCV-RNA using biotinylated and radioiodinated primers. Study subjects were 118 patients with positive anti-HCV. HCV-RNA in patient's serum was extracted by guanidium thiocyanate method. After first amplification, the product was reamplified by primers labelled with biotin and I-125. The final amplification product was defected by counting the radioactivity after incubation in avidin coated tubes. In 51 samples, the test was repeated for evaluation of reproducibility. This new method was also compared with conventional RT-PCR methods in 34 samples from patients with chronic liver disease. The results were as follows ; 1) HCV-RNA was positive in 85(97%)of 88 patients with chronic liver disease, and in 23 (73%) of 30 patients with normal liver function. 2) In comparison with conventional method, HCV-RNA was detected in 32(94%) of 34 patients with new method, whereas in 27(79%) of the same group with conventional method. 3) Repeated test with new method in 52 samples demonstrated 82% of concordant result. In conclusion, new method with biotinylated and radioiodinated primers was more sensitive than conventional method. However, great care must be taken for quality control because there were considerable interassay variation and possiblity of false positivity and false negativity.

  • PDF

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

Evaluation after Applicated a Mold to a Paraneoplastic Autoimmune Multiorgan Syndrome Patient with Hypervascular Ulcer in the Oral Cavity during Treatment with Mold Brachytherapy (Paraneoplastic Autoimmune Multiorgan Syndrome으로 인하여 구강 내 국소적으로 발생한 과다혈관성 궤양의 방사선 근접치료 시 자체 제작한 Mold의 유용성 평가)

  • Park, Ju-Kyeong;Lee, Sun-Young;Lim, Seok-Geon;Kwak, Geun-Tak;Lee, Seung-Hun;Kim, Yang-Su;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Purpose: Evaluate the mold we have made to improve the reproducibility of the patient position and make homogeneous dose distribution to the treatment volume effectively when treating the patient who has hypervascular ulcer on her tongue caused by paraneoplastic autoimmune multiorgan syndrome by mold brachytherapy. Materials and Methods: The mold is consisted of upper and lower parts. We inserted 2 mm of lead sheet on the gums toward the oral cavity to protect them from unnecessary irradiation during the treatment. We had planned on orthogonal images obtained the patient. 200 cGy was delivered in every fraction with a total dose of 3000 cGy. To evaluate the effect of the lead sheet, we made a measurement with a phantom that has gums and tongue made of tissue with an equivalent material (bolus). Five of TLDs were placed on the interesting points of gums to measure the dose during irradiation with lead sheet and without lead sheet for three times respectively. Results: The result of the measurement without lead sheet are A: 33.9 cGy, B: 30.1 cGy, C: 31.8 cGy, D: 23.3 cGy, E: 24.1 cGy. The results of measurement with lead sheet are A: 20.6 cGy, B: 18.8 cGy, C: 19.6 cGy, D: 14.7 cGy, E: 15.1 cGy. Conclusion: Since we are using the mold made in our department during the treatment of the patient with hypervascular ulcer on tongue, we could deliver a proper dose to the treatment volume. In addition, the mold provided highly accurate and reproducible treatment and reduced the dose to the gums and teeth. Therefore, the possibility of side effects could be decreased significantly.

  • PDF

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

Study on ZnO Nanoparticle Dispersions in Test Media Including Natural Organic Matter for Ecotoxicological Assessment (천연유기물을 포함한 산화아연 나노입자 분산배지의 생태독성평가 적용성 연구)

  • Park, Sun-Young;Kim, Kyung-tae;Shin, Yu-jin;Kim, Ji-eun;Lee, Jae-woo;Jo, Eunhye;Sung, Hwa kyung;Kim, Pil-je;Choi, Kyung-hee;Eom, Ig-chun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.11
    • /
    • pp.634-640
    • /
    • 2017
  • Toxicity and fate assessment is necessary in the evaluation of the environmental, health and safety risks of engineered nanomaaterials (ENMs). Therefore, in order to ensure the reproducibility, reliability and relevance of ENMs toxicity results, stable and monomodal dispersion protocols in toxicity test media are needed. Zinc oxide nanoparticles (nZnO) are widely used in various products such as cosmetic products, paper, paints etc. In this study, nZnO dispersions in ecotoxicity test media were produced by following a series of steps of modified National Institute of Standards and Technology (NIST) Special publication 1200-5. In addition, natural organic matter (humic acid (HA)) was used as a stabilizing agent to disperse nZnO in the test media. The hydrodynamic diameters (HDD) of the nZnO in dispersion ranged between 150 and 200 nm according to the dynamic light scattering (DLS) measurement. Based on these dispersions in ecotoxicity test using ecological species (Oryzias latipes, Daphnia magna, Pseudokirchneriella subcapitata and Chironomusus riparius), dispersion protocol was found to have a considerable potential in ecotoxicity test of ENMs.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.