• Title/Summary/Keyword: Reproducibility evaluation

Search Result 344, Processing Time 0.026 seconds

Development of Oil Leakage Stability Evaluation for Composite Aterproofing Methods using Asphalt Mastic and Modified Asphalt Sheet in Concrete Structure (콘크리트 구조물에 사용되는 개량아스팔트 시트와 아스팔트 매스틱을 복합화한 방수공법의 누유안정성 평가방법 개발)

  • Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.1
    • /
    • pp.19-29
    • /
    • 2019
  • In this study, a revised oil leakage evaluation method for assessing oil leakage stability of asphalt mastics used in upper slabs of below-grade residential parking lots was developed and presented. In order to verify the reliability and reproducibility of leakage results, the parameters the revised evaluation was carried out for three products with actual leakage history, and it was confirmed the leaks could be reproduced whereas the existing methods could not. To quantitatively verify the reproducibility, the filler content of the leaked samples was derived and the maximum filler content was 64% lower than that of the normal sample. The same results was found with the samples from the actual leakage site, thus verifying the reliability of the revised evaluation method.

Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences

  • Choi, Won-joon;Lee, Su-jung;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.52 no.1
    • /
    • pp.20-28
    • /
    • 2022
  • Objective: Although, digital models have recently been used in orthodontic clinics, physical models are still needed for a multitude of reasons. The purpose of this study was to assess whether the printed models can replace the plaster models by evaluating their accuracy in reproducing intermaxillary relationships and by appraising the clinicians' ability to measure the printed models. Methods: Twenty sets of patients' plaster models with well-established occlusal relationships were selected. Models were scanned using an intraoral scanner (Trios 3, 3Shape Dental System) by a single operator. Printed models were made with ZMD-1000B light-curing resin using the stereolithography method 3-dimensional printer. Validity, reliability, and reproducibility were evaluated using measurements obtained by three operators. Results: In evaluation of validity, all items showed no significant differences between measurements taken from plaster and printed models. In evaluation for reliability, significant differences were found in the distance between the gingival zeniths of #23-#33 (DZL_3) for the plaster models and at #17-#43 (DZCM_1) for the printed models. In evaluation for reproducibility, the plaster models showed significant differences between operators at midline, and printed models showed significant differences at 7 measurements including #17-#47 (DZR_7). Conclusions: The validity and reliability of intermaxillary relationships as determined by the printed model were clinically acceptable, but the evaluation of reproducibility revealed significant inter-operator differences. To use printed models as substitutes for plaster models, additional studies on their accuracies in measuring intermaxillary relationship are required.

Gauge Capability Analysis and Designed Experiments (계측기 능력분석과 실험계획법)

  • Baik, Jaiwook;Jo, Jinnam
    • Journal of Korean Society for Quality Management
    • /
    • v.24 no.3
    • /
    • pp.145-159
    • /
    • 1996
  • In today's organization, measurement plays a crucial role in helping improve process or quality. In this paper, we review the measurement error study, classical gauge repeatability and reproducibility study, and designed experiment suited for the determination of the measurement capability. Measurement error study is very simple to use but is rather crude. Hence, it should be used as a preliminary study to determine whether further study is necessary. Classical gauge repeatability and reproducibility (GR&R) study is the most common technique for evaluation of gauge capability. It calculates a percentage that relates the repeatability, reproducibility, and overall R&R to the specification range for the parameter measured. Hence, the individual repeatability and reproducibility statistics will indicate the area on which to concentrate. However, GR&R study only gives a point estimate of each component, which leaves a room for improvement. It is always good to integrate the use of control charts to ascertain the statistical stability of the measurement process. The tools of statistical experimental design are available for a comprehensive design and analysis of the measurement process. Hence, in this paper, we present gauge capability analysis as an experimental design problem and compare it with the classical GR&R study.

  • PDF

Comparative Evaluation of Reproducibility for Spatio-temporal Rainfall Distribution Downscaled Using Different Statistical Methods (통계적 공간상세화 기법의 시공간적 강우분포 재현성 비교평가)

  • Jung, Imgook;Hwang, Syewoon;Cho, Jaepil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.1-13
    • /
    • 2023
  • Various techniques for bias correction and statistical downscaling have been developed to overcome the limitations related to the spatial and temporal resolution and error of climate change scenario data required in various applied research fields including agriculture and water resources. In this study, the characteristics of three different statistical dowscaling methods (i.e., SQM, SDQDM, and BCSA) provided by AIMS were summarized, and climate change scenarios produced by applying each method were comparatively evaluated. In order to compare the average rainfall characteristics of the past period, an index representing the average rainfall characteristics was used, and the reproducibility of extreme weather conditions was evaluated through the abnormal climate-related index. The reproducibility comparison of spatial distribution and variability was compared through variogram and pattern identification of spatial distribution using the average value of the index of the past period. For temporal reproducibility comparison, the raw data and each detailing technique were compared using the transition probability. The results of the study are presented by quantitatively evaluating the strengths and weaknesses of each method. Through comparison of statistical techniques, we expect that the strengths and weaknesses of each detailing technique can be represented, and the most appropriate statistical detailing technique can be advised for the relevant research.

Reproducibility Evaluation of Stratification Using EFDC Model in Nakdong River (EFDC 모형을 이용한 낙동강에서의 성층현상 재현성 평가)

  • Choi, Hyun Gu;Han, Kun Yeun;Park, Jun Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.561-573
    • /
    • 2017
  • Nakdong River was recently dredged with multi-functional weirs construction. Therefore, the depth was deepened and the lag time also increased. As a result, stratification occurred in some sections with deep water depth, and it also caused the increase of algal bloom phenomenon. The purpose of this study is to evaluate reproducibility of stratification in the Nakdong River by applying the EFDC model, which is a three-dimensional hydraulic and water quality analysis model proving the reproducibility of stratification phenomena in reservoirs and estuaries. In order to reproduce the Nakdong river water temperature and DO stratification, EFDC model was constructed in the downstream part of the Nakdong river and sensitivity analysis was performed on key parameters sensitive to stratification. Sensitivity analysis was used to reproduce stratification by selecting optimal parameters. The results of this study can be used as basic data for the analysis of various destratification scenarios.

Design of the Calibration System for Determining the Sensitivity of Ultrasonic Transducer (초음파 변환기의 감도 교정 시스템 구성)

  • 사공성대;조문재;최봉열
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.200-207
    • /
    • 1999
  • In this paper, a precise sensitivity measurement system of ultrasonic transducer in the frequency range from 1 MHz to 15 MHz, which can implement the reciprocity principle is constructed. All of the elements of this system such as the ultrasonic preamplifier, ultrasonic absorber, water tank, water degassing system, and four-axes translator and reflector are constructed. For the performance evaluation of the calibration system, a standard hydrophone precisely calibrated from PTB(Physikalisch Technische Bundesanstalt) in Germany are used. And the system parameters which affected the evaluation of the measurement accuracy and the reproducibility in various measuring conditions are considered. The measurement uncertainty of the calibration system is estimated within $\pm$ 2.0㏈.

  • PDF

EVALUATION OF THE REPRODUCIBILITY IN CEPHALOGRAPHY USING ROENTGENOCEPHALOMETRICS AND PHOTOGRAPHIC SUBTRACTION (두부방사선 계측과 Photographic subtraction을 이용한 측모 두부방사선 규격사진의 재현성에 관한 연구)

  • Jeon Seon-Doo;Nha Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.347-359
    • /
    • 1994
  • The reproducibility of cephalography in repeated exposures were studied by tracing and photographic subtraction. The materials consisted of 50 pairs of 'same day' radiograph taken under identical conditions. The evaluation included skull, cervical column, hyoid bone, pharynx, tongue, soft tissue profile resulting 43 items in tracing, and 19 items in photographic subtraction. The results obtained from the differences between each pair were as follows: 1. The means and standard deviations by tracing of skull, cervical column, hyoid bone, pharynx, tongue, soft tissue profile were 0.34±0.62㎜, 1.02±1.59㎜, 1.37±1.78㎜, 0.55±1.16㎜, 0.51±1.51㎜, 0.15±0.3㎜ each. 2. The means and standard deviations by photographic subtraction of skull, cervical column, hyoid bone, pharynx, tongue were 0.09±0.35㎜, 0.70±0.95㎜, 1.22±1.33㎜, 0.53±0.86㎜, 0.27±0.41㎜ each.

  • PDF

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Evaluation of Reliability of Automatic System for Measuring Sizing Degree by Basis Weight Variation of Paper (종이 평량의 차이에 따른 자동 사이즈도 측정 시스템의 신뢰성 평가)

  • Lee, Ji-Young;Kim, Chul-Hwan;Lee, Ji-Young;Nam, Hye-Gyeong;Lee, Gyeong-Sun;Jo, Hu-Seung;Park, Hyung-Hun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.3
    • /
    • pp.11-19
    • /
    • 2014
  • Reliability of the novel automatic system capable of measuring both St$\ddot{o}$ckigt sizing degree and contact angle at a time was evaluated through the calculation of its repeatability and reproducibility based on TAPPI Standard Method T 1200. As the basis weight of paper specimen increased, the repeatability and reproducibility of the automatic system became more improved than those from Hercules sizing test and contact angle test designated on TAPPI Standard Method T 530 and T 558. The more improved repeatability and reproducibility implies that a single tester can obtain the similar results under similar test conditions in spite of repetitive testing using the automatic system, and likewise that multiple testers can respectively reproduce similar data without big variation from the same paper specimen using the automatic system. In conclusion, this study is greatly meaningful in having developed the world's first automatic system to measure both St$\ddot{o}$ckigt sizing degree and contact angle simultaneously with excellent repeatability and reproducibility.