• Title/Summary/Keyword: Reproducibility evaluation

Search Result 344, Processing Time 0.026 seconds

Development of Radiation Shielding Sheet with Environmentally-Friendly Materials; II: Evaluation of Barum, Tourmaline, Silicon Polymers in the Radiation Shielding Sheet (친환경 소재의 의료 방사선 차폐 시트 개발; II: 바륨, 토르말린의 실리콘 폴리머 차폐 시트의 성능 평가)

  • Kim, Seon-Chil;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • We developed an alternative radiation shielding material which is economical and has high protection efficiency. We validated the material in the form of sheet to make an apron. We increased the rate of barium and mixed tourmaline into silicon to improve the flexibility and protection rate of the sheet. The results showed that the shielding effect at low radiation energy is good enough with both 5 mm and 7 mm thickness. In the future, we will perform a quantitative evaluation of the reproducibility, volumetric efficiency, and porosity in mixing the ingredients.

Reliability of the Visual Discrimination Scale on Oral Mucosa Pressure Ulcer for Healthcare Providers (의료인을 위한 구강점막욕창 시각적 감별도구의 신뢰도)

  • Uhm, Ju-Yeon;Kim, Myoung Soo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.443-450
    • /
    • 2020
  • The purpose of this study was to examine the inter-rater and intra-rater reliability of the oral mucosa pressure ulcer classification system based on the photographs. The study consisted of two stages; development and evaluation. In the developmental stage, 9 photographs of 82 were selected. In the evaluation stage, a total of 49 participants were invited web-based survey by e-mail. Cohen's weighted kappa and Krippendorff's alpha were used to define the inter-rater reliability. Nine photographs consisted of two, three, three, and one in normal, stage 1, stage 2, and stomatitis, respectively. The inter-rater reliabilities of wound care nurse specialist, intensive care nurse specialist, and dentist groups were 0.75, 0.70, and 0.78, respectively. The intra-rater reliability was 0.73. The inter-rater and intra-rater reliabilities of the oral mucosa pressure ulcer classification system showed substantially good agreement.

Improved X-ray Center Beam Alignment Evaluation Method (개선된 X선 중심선속정렬평가 측정법)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.827-832
    • /
    • 2020
  • X-ray equipment, which is frequently used in radiology and treatment, is the most common and most used equipment in clinical practice. Equipment must provide accurate information to patients through continuous quality control. In case of manual quality control measurement, reproducibility may be poor and there may be a problem with reliability of evaluation results. In this study, an automated program was developed and attempted to measure how much the central ray between the focus of the X-ray tube and the variable aperture of the diagnostic X-ray generator used in clinical practice coincides. As a result of the experiment, it succeeded in calculating the coordinates of the two center points, and the distance between the two points was calculated in pixels and applied to the judgment and the automatic judgment value for whether the center line coincidence is within the normal angle or the abnormal angle is presented. The results of this study are considered to be very helpful in the quality control of the X-ray apparatus.

Understanding and Reducing Performance Variation in New Product Development Using Paper Helicopter Experiment (종이 헬리콥터 실험을 통한 개발단계 성능변동의 이해와 개선)

  • Shin, Byung-Cheol;Kim, Si-Ung;Jeong, Sun Min;Byun, Jai-Hyun;Nam, Yong-Seog
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.4
    • /
    • pp.589-606
    • /
    • 2015
  • Purpose: In developing new products, reducing performance variation is important for competitiveness factors such as quality, cost, and delivery. This paper aims at evaluating three performance variations; measurement, performance evaluation, and manufacturing variations, and then improving product and process design, focused on paper helicopter making case study. Methods: For measurement system analysis, gage R&R (repeatability and reproducibility), linearity, stability are evaluated. Since gage R&R are not satisfactory, the measurement system is improved by adopting voice memos application of iPhone and providing standard measurement procedure. To evaluate performance variation, product deterioration and environment factor (wind speed) is considered. Since the existing design is sensitive to these noise factors, a new product design is developed, which is proven to be robust to the noise factors. Finally, manufacturing variations are evaluated with five factors which can cause variation in flight time. To reduce the impact of three significant factors, three improvement methods are applied. Results: Three performance variations are evaluated and robust paper helicopter design is presented. Conclusion: To reduce measurement and process variations, improved measurement method and paper helicopter making procedure are proposed. A new product design is also presented which is robust to deterioration and environmental variation. This paper is expected to benefit students and practitioners who want to have hands-on knowledge on new product quality improvement.

A Study on Characterization for Stacking Fault Evaluation of CFRP Composite Laminates Using an EMAT Ultrasonics (전자기 초음파를 이용한 CFRP 복합적층판의 적층배향 특성평가에 관한 연구)

  • Im, Kwang-Hee;Na, Seung-Woo;Kim, Ji-Hoon;Lee, Chang-Ro;Hsu, David K.;Yang, In-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.83-92
    • /
    • 2005
  • An electromagnetic acoustic transducer (EMAT) is a unique probe that does not require a couplant or gel and also can usually generate or detect an ultrasonic wave into specimens across a small gap. It, therefore can be applied in a noncontact mode with a high degree of reproducibility. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. This shear wave for detecting the presence of the errors is very sensitive. A decomposition model has been used in the interpretation and prediction of test results. Test results have been com pared with model data. It is found that the high probability shows between tests and the model utilized in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform (2-D FFT).

Development of Alternative Testing Methods without Hazardous Reagents used in Korean Pharmaceutical Codex (고시의약품 시험에 사용되는 유해시약 대체 시험법 개발)

  • Kim, Hee-Yun;Kang, Hyun-Kyung;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Choi, Sung-Hee;Kim, Jin-Hee;Lee, Hwa-Jung;Kang, Chan-Soon
    • YAKHAK HOEJI
    • /
    • v.54 no.2
    • /
    • pp.142-149
    • /
    • 2010
  • Development of alternative testing methods for the replacement of hazardous reagents with less hazardous ones is strongly enforced because exposure of human and environment to hazardous reagents are restricted and hazardous reagents are gradually prohibited from using in various testing methods. Thus, in this study, we developed 8 monographs from the Korean Pharmaceutical Codex by substituting the use of the hazardous reagents including ICH class 1 such as benzene, chloroform and dioxane to the use of less toxic ones like ICH class 2 or 3 reagents. We also improved their qualification and quantification performance. Among 8 monographs, the 6 newly developed TLC methods for the identification of nifedipine, oxolamine citrate, ketoprofen lysinate, chlorquinaldol, retinol acetate, and riboflavin showed a clear spot of corresponding material without any interference in spite of the replacement with ICH class 2 or 3 reagents. For the quantification of domperidone and trimebutine, HPLC methods were developed for the substitution of UV/VIS spectrometry and titrimetry, respectively. These HPLC methods were validated for the linearity, recovery, reproducibility, and inter-laboratory variations. In conclusion, the newly developed methods could be expected to become valuable tools for revising the Korean Pharmaceutical Codex.

Development of Smart Soccer Socks Using a Textile Stretch Sensor -Focused on Middle School Girls between the Ages of 14 and 15- (텍스타일형 스트레치 센서를 이용한 스마트 축구 양말 개발 -14~15세 여중생을 중심으로-)

  • Kim, Ji-seon;Park, Jinhee;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.24 no.3
    • /
    • pp.17-29
    • /
    • 2020
  • This study aimed to produce fiber stretch sensors for smart soccer socks to prevent injuries during training. A sensor was manufactured with stretchable fabric and tested to ensure convenience during training. In order to manufacture the fiber stretch sensor, a CNT dispersion solution was applied to an e-band and elastic polyester fabric, and the performance of the sensors was evaluated by a tensile test. Performance evaluation showed that both of the tested fabrics are excellent for this purpose. Both sensors were attached to socks to create prototype wearable devices, and an experiment was conducted to determine whether a resistance change accompanying relaxation and contraction of the gastrocnemius muscle could be detected. In order to accurately evaluate performance as a sensor, the fabric was stretched 20 times at low speeds of 1 Hz and 0.5 Hz. A change in resistance due to tension was observed, with both the E-band and the stretchable poly fabric showing high sensitivity and high reproducibility. Both can be used as relaxation/contraction sensors. Smart soccer socks were made using the two materials, and an evaluation was conducted. Tensile tests were done on the smart soccer socks; the tests were done 20 times per sock, and the sensor showed a stable resistance change between 30 and 40 ohms depending on the tension of the sensor. As a result, we confirmed that smart soccer socks with stretch sensors made of E-bands can measure changes in the gastrocnemius muscle.

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.

Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile (압전 필름과 전도성 섬유를 이용한 맥파 전달 속도 측정을 위한 센서의 제작 및 성능평가)

  • Kim, Jung-Chae;Jee, Sun-Ha;Yoo, Sun-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.135-143
    • /
    • 2012
  • Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

Development and Psychometric Assessment of a Self-evaluation Questionnaire for Gastroesophageal Reflux Disease

  • Jung, Hye-kyung;Choi, Myung-Gyu;Baek, Myung-Ki;Wu, Justin CY
    • Journal of Neurogastroenterology and Motility
    • /
    • v.24 no.4
    • /
    • pp.584-592
    • /
    • 2018
  • Background/Aims There is uncertainty about how to measure outcomes reported by patients in gastroesophageal reflux disease (GERD). This study was conducted to develop an instrument and to determine of the definition of respondent for a patient reported outcomes to assess the efficacy of a treatment used for GERD treatment. Methods A structural process has developed a self-evaluation questionnaire for GERD (SEQ-GERD); health-related quality of life questionnaire for GERD (GERD-QOL) was translated through cross-cultural validation. Two-week reproducibility was evaluated and construct validity was assessed by correlating the SEQ-GERD with the Patient Assessment of Gastrointestinal Disorders (PAGI-SYM), the reflux disease questionnaire (RDQ), and GERD-QOL. Changes in SEQ-GERD scores were compared to assess the discriminative validity following 4 weeks of proton pump inhibitor administration. Results A total of 83 Korean patients were included (mean age $46{\pm}14$ years, females 61.4%). The internal consistency of the 19-item SEQ-GERD was good (alpha = 0.60-0.94) and the test-retest reliability was high (intra-class correlation coefficient = 0.67-0.95). The SEQ-GERD highly correlated with the GERD domain of the PAGI-SYM (correlation coefficient r = 0.894, P < 0.001), the RDQ-GERD (r = 0.877, P < 0.001), and GERD-QOL (r = -0.536, P < 0.05). SEQ-GERD scores significantly varied according to the overall treatment effectiveness scale of drug responsiveness and significantly decreased after drug treatment (mean differences according to the overall treatment effectiveness scale, P = 0.020). Conclusion This study supports that SEQ-GERD is reliable and valid, and can be used to evaluate the treatment response in patients with GERD.