• 제목/요약/키워드: Reproducibility evaluation

검색결과 344건 처리시간 0.032초

규격화된 구내 표준 방사선사진의 계수 공제 방사선학적 평가 (DIGITAL SUBTRACTION RADIOGRAPHIC EVALUATION OF THE STANDARDIZED PERIAPICAL INTRAORAL RADIOGRAPHS)

  • 조봉혜;나경수
    • 치과방사선
    • /
    • 제23권1호
    • /
    • pp.125-136
    • /
    • 1993
  • The geometrically standardized intraoral radiographs using 5 occlusal registration materials were taken serially from immediate, 1 day, 2, 4, 8, 12, and 16 weeks after making the bite blocks. And the resultant images were digitally subtracted using the immediately taken film as reference images. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exal1ex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. the lesser the standard deviation, the better the quality of the subtracted images. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  • PDF

내열용 오버레이 12%Cr계 스테인레스강의 열피로 특성에 미치는 Cr 함량과 델타-페라이트의 영향 (Effects of Cr Content and Volume Fraction of δ-Ferrite on Thermal Cycling Fatigue Properties of Overlay Welded Heat-Resistant 12%Cr Stainless Steels)

  • 정재영
    • 소성∙가공
    • /
    • 제26권6호
    • /
    • pp.356-364
    • /
    • 2017
  • In this study, submerged arc cladded Fe-Cr-Ni-Mo-CuWNbV-C stainless steels containing various Cr contents between 11.2 wt.% and 16.7 wt.% were prepared with fixed C content at about 0.14 wt.%. Using these alloys, changes in microstructure, tensile property, and thermal fatigue property were investigated. Phase fraction of delta-ferrite was increased gradually with increasing Cr content. However, tensile strength, hardness, and thermal fatigue resistance appeared to be decreased. When the microstructure of delta-ferrite was observed, it was revealed that the mesh structure retained up to about 15% Cr content. Although thermal fatigue resistance was almost the same for Cr contents between 11.0 and 14.5 wt.%, it was significantly decreased at higher Cr contents. This was evident from mean value of crack lengths of 10 largest ones. Evaluation of thermal fatigue resistance on alloys with various Cr contents revealed the following important results. First, the reproducibility of ranking test was excellent regardless of the number of cycles. Second, thermal fatigue resistance was increased in proportion to true tensile fracture strength values of overlay materials. Finally, the number of thermal fatigue cracks per unit length was increased with increasing true tensile fracture strength.

비침습적 간섬유화 측정기(Fibroscan)의 기술적 개요와 한의임상적 유용성 고찰 (The Technological Concept of Fibroscan and its Clinical Usefulness in the Traditional Korean Medical Field)

  • 손창규
    • 대한한방내과학회지
    • /
    • 제36권2호
    • /
    • pp.85-92
    • /
    • 2015
  • Objectives: The liver fibroscan has been developed as a noninvasive and convenient method to assess hepatic fibrosis. This study aimed to review this device in terms of its technological concept and clinical application in traditional Korean medicine (TKM). Methods: The technological background, diagnostic evaluation, and clinical usefulness of fibroscan were reviewed using various literature and clinical studies. One clinical example-a patient with hepatofibrosis who had been treated with TKM-is presented. Results: The liver fibroscan was approved as a medical device for noninvasive measurement of the hepatic fibrosis level by the Korean Food and Drug Administration (KFDA). Numerous clinical studies have confirmed that its sensitivity and specificity allow it to serve as a substitute for liver biopsy, the present gold standard diagnostic method. The accuracy and reproducibility and lack of technical risks are strong points of the fibroscan; however, it has some limitations for application, especially in patients with obesity or severe hepatitis. One clinical example showed the applicability of the liver fibroscan in herbal medicine-based treatments. Conclusions: The requirement for diagnostic medical devices is an important issue in TKM; therefore, this study provides valuable information for practitioners of TKM.

High Temperature Fiber Fragmentation Characteristics of SiC Single-Fiber Composite With Titanium Matrices

  • Matikas, Theodore E.
    • Advanced Composite Materials
    • /
    • 제17권1호
    • /
    • pp.75-87
    • /
    • 2008
  • Aerospace structural applications, along with high performance marine and automotive applications, require high-strength efficiency, which can be achieved using metal matrix composites (MMCs). Rotating components, such as jet-engine blades and gas turbine parts, require materials that maximize strength efficiency and metallurgical stability at elevated temperatures. Titanium matrix composites (TMCs) are well suited in such applications, since they offer an enhanced resistance to temperature effects as well as corrosion resistance, in addition to optimum strength efficiency. The overall behavior of the composite system largly depends on the properties of the interface between fiber and matrix. Characterization of the fiber.matrix interface at operating temperatures is therefore essential for the developemt of these materials. The fiber fragmentation test shows good reproducibility of results in determining interface properties. This paper deals with the evaluation of fiber fragmentation characteristics in TMCs at elevated temperature and the results are compared with tests at ambient temperature. It was observed that tensile testing at $650^{\circ}C$ of single-fiber TMCs led to limited fiber fragmentation behavior. This indicates that the load transfer from the matrix to the fiber occurs due to interfacial friction, arising predominantly from mechanical clamping of the fiber by radial compressive residual and Poisson stresses. The present work also demonstrates that composite processing conditions can significantly affect the nature of the fiber.matrix interface and the resulting fragmentation of the fiber.

The G115 standardized ginseng extract: an example for safety, efficacy, and quality of an herbal medicine

  • Bilia, Anna R.;Bergonzi, Maria C.
    • Journal of Ginseng Research
    • /
    • 제44권2호
    • /
    • pp.179-193
    • /
    • 2020
  • Ginseng products on the market show high variability in their composition and overall quality. This becomes a challenge for both consumers and health-care professionals who are in search of high-quality, reliable ginseng products that have a proven safety and efficacy profile. The botanical extract standardization is of crucial importance in this context as it determines the reproducibility of the quality of the product that is essential for the evaluation of effectiveness and safety. This review focuses on the well-characterized and standardized ginseng extract, G115, which represents an excellent example of an herbal drug preparation with constant safety and efficacy within the herbal medicinal products. Over the many decades, extensive preclinical and clinical research has been conducted to evaluate the efficacy and safety of G115. In vitro and in vivo studies of G115 have shown pharmacological effects on physical performance, cognitive function, metabolism, and the immune system. Furthermore, a significant number of G115 clinical studies, most of them double-blind placebo-controlled, have reinforced the findings of preclinical evidence and proved the efficacy of this extract on blood glucose and lipid regulation, chronic obstructive pulmonary disease, energy, physical performance, and immune and cognitive functions. Clinical trials and 50 years of presence on the market are proof of a good safety profile of G115.

인도페놀법을 이용한 수용액 중 암모니아 정량에 관한 연구 : 평형법, 반응속도법, 흐름주입분석법의 비교와 평가 (Determination of Aqueous Ammonia with Indophenol Method : Comparision and Evaluation for the Reaction-Rate, Equilibrium and Flow-Injection Analysis Methods)

  • 정형근;김범식
    • 한국환경과학회지
    • /
    • 제4권1호
    • /
    • pp.91-103
    • /
    • 1995
  • The reaction rate, equilibrium, and flow injection analysis methods were fundamentally evaluated for the determination of aqueous ammonia. The selected indophenol blue method was based on the formation of indophenol blue in which ammonium ion reacted with hypochlorite and phenol in alkaline solution. In the optimized reaction condition, the reaction followed 1st order reaction kinetics and the final product was stable. The absorbance measurements before and after the equilibrium were utilized for the reaction rate and equilibrium methods. The reaction rate methods, based on the relative analytical signals for the possibility of eliminating interferents, were shown to have good linear calibration curves but the detection limit and the calibration sensitivity were poorer than those in the equilibrium method. The detection limits were 32-49 pub and 24 pub for the reaction rate and equilibrium methods, respectively In the flow injection analysis, the absorbance was measured before the equilibrium reached and thus resulted in 30% reduction of calibration sensitivity. However, the detection limit was 11 ppb, indicating that the peak-to-peak noise for the blank was remarkably improved. Compared to the manual methods, the optimized experimental condition in a closed reaction system reduced the blank absorbance and the inclusion of ammonia from the atmosphere was prevented. In addition, highly reproducible mixing of sample and reagents and analytical data extracted from continuous recording showed excellent reproducibility.

  • PDF

발한써멀마네킨을 이용한 투습방수의류의 착용쾌적성 평가 (Wear Comfort Evaluation on Water-vapor-permeable (WVP) Garments Using a Movable Sweating Thermal Manikin)

  • 강인형;이한섭
    • 한국의류학회지
    • /
    • 제37권8호
    • /
    • pp.1095-1106
    • /
    • 2013
  • This study evaluated the wear comfort properties of water-vapor-permeable (WVP) garments using a movable sweating thermal manikin. Manikin tests were performed in a climatic chamber (temperature T=20, $35{\pm}0.5^{\circ}C$ and relative humidity $H=50{\pm}10%$) using seven sportswear outfits (a long sleeve shirts and a long pants) made with seven different WVP fabrics. Physiological responses of wear trials could be correlated with measurement parameters of the thermal manikin experiment; subsequently, a regression model that represented a final comfort sensation could be obtained. The regression model developed in this work is based on thermal manikin measurements; consequently, it provides an independent comfort sensation level in a relatively short time at a low cost while maintaining the reproducibility of results. It translates into more actual choices for sportswear manufacturers and sportswear consumers.

전파정류방식의 고전압발생장치를 이용한 X선 기기의 특성 평가 (Characteristic Analysis of X-ray Device using the High Voltage Generator on Full-wave Rectification Method)

  • 김영표;김태곤;이호식;박용필;천민우
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.516-521
    • /
    • 2009
  • X-ray system which is usefully used in diagnosis of the patient, being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This research has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

Understanding the Left Right Judgement Test: A Literature Review

  • Kim, Asall;Yi, Chung-hwi
    • 한국전문물리치료학회지
    • /
    • 제28권4호
    • /
    • pp.235-244
    • /
    • 2021
  • Background: The body schema, which is constantly updated using somatosensory information, enables accurate movement. Since pain is reported as a possible source to alter the body schema, the left right judgement test (LRJT) has been widely used in the pain rehabilitation. However, there was a lack of consistency in the effect of the pain on the LRJT results, and for the effect of the LRJT as a part of intervention programs for pain patients. The deeper understand of the LRJT is necessary for better reproducibility, and to expand the therapeutic applications of the LRJT in the pain and musculoskeletal rehabilitation. Objects: This literature review aimed to understand the LRJT and to study the potential of the LRJT for therapeutic applications. Methods: The PubMed database was searched for studies relevant to LRJT. To establish the query set, the term was regarded from various perspectives. Results: The selected studies were classified into three categories: LRJT development, factors influencing LRJT, and therapeutic applications. Conclusion: Left right judgement test is the evaluation tool for the integrity of body schema as well as a tool for implicit motor imagery. Pain, proprioception, and other factors influence the performance of the LRJT.

Evaluation of the relationship between sleep bruxism and pulpal calcifications in young women: A clinico-radiological study

  • Tassoker, Melek
    • Imaging Science in Dentistry
    • /
    • 제48권4호
    • /
    • pp.277-281
    • /
    • 2018
  • Purpose: This study was performed to investigate the relationship between sleep bruxism(SB) and pulpal calcifications in young women. Materials and Methods: A total of 100 female participants between 20 and 31 years of age who were referred to our radiology clinic for a dental check-up, including 59 SB and 41 non-SB patients, were sampled for the analysis. SB was diagnosed based on the American Academy of Sleep Medicine criteria. All teeth were evaluated on digital panoramic radiographs to detect pulpal calcifications, except third molars, teeth with root canal treatment, and teeth with root resorption. Binary logistic regression analysis was used to determine the risk factors for pulpal calcifications. The Spearman correlation coefficient was applied and the Pearson chi-square test was used for categorical variables. To test intra-examiner reproducibility, Cohen kappa analysis was applied. P values <.05 were considered to indicate statistical significance. Results: A total of 2800 teeth were evaluated (1652 teeth from SB patients and 1148 from non-SB patients), and 61% of patients had at least 1 dental pulpal calcification. No statistically significant relationship was found between SB and pulpal calcifications (P>0.05). In SB patients, the total number of pulpal calcifications was 129, while in non-SB patients, it was 84. Binary logistic analysis showed that SB was not a risk factor for the presence of pulpal calcifications(odds ratio, 1.19; 95% CI, 0.52-2.69, P>.05). Conclusion: No relationship was found between SB and pulpal calcifications.