• Title/Summary/Keyword: Representative beat extraction algorithms

Search Result 2, Processing Time 0.014 seconds

A Comparison of Representative Beat Extraction Algorithms in ECG (심전도 신호에서의 대표 비트 설정에 관한 알고리즘 비교)

  • 김동석;전대근;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.299-305
    • /
    • 1999
  • In thls paper, the representative beal textraction algorIthms for the diagnostic parameter extraction in noisy signal were compared. We used the avernge, median, mode, and trmmed mean to calculale the central tendency. In our experimenl, we have restricted to four kinds of noises -EMG noise, 60Hz powerline inlerference, ahrupl baseline shift, and baselme drift due to respimtion-which were commonly occurred in ECG mgnal, then we have calculated signal-to-noise ratios(SNRs) for the ECG corrupted with each noise and all noises together. As the result of this paper, we have proved that the average method has super lor performance than the others in the ECG corrupted wilh EMG noise. When the signal mcludes extreme value such as abrupt baseline shIft, the median, mode, trimmed mean methods have supenor performance in the SNR ratios. Especially when the ECG corrupted with baseline drift due to respirallon, the trimmed mean method was most efficient because ST level change was 0 V.

  • PDF

An implementation of automated ECG interpretation algorithm and system(I) - Introduction of YECGA (심전도 자동 진단 알고리즘 및 장치 구현(I) - YECGA 개요)

  • Kweon, H.J.;Jeong, K.S.;Chung, S.J.;Choi, S.J.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.175-178
    • /
    • 1996
  • The purpose of this thesis is the propose of various signal processing algorithm for the ECG(electrocardiogram) and the design of realtime automated ECG analyzer feasible with these algorithms. The algorithms are composed of (1)filtering procedure fer the estimation and removal of baseline drift, 60Hz power line interference, and muscle artifacts (2)detection procedure of QRS complex and P wave (3)typification procedure for the pattern classification according to the morphologies (4) selection of representative beat, significant point and wave boundary decision procedure and (5) parameter extraction and diagnosis procedure. All verifications are carried out between the algorithms proposed in this paper and other algorithms already proposed by many researchers, for the objective comparison in each procedure. The efficiency of proposed algorithms are demonstrated with the aid of internationally validated CSE database and the performances of filtering procedure are compared on artificial noise signal as well as actual ECG signals with appropriate noise components. for the comparison on the performance of designed automated ECG analyzer, the diagnosis results were compared with ECG analyzer manufactered by Fukuda denshi in Japan.

  • PDF