• Title/Summary/Keyword: Replicate

Search Result 853, Processing Time 0.027 seconds

Fluorimetric Determination of Dichloroacetamide by RPLC with Postcolumn Detection

  • Choi, Yong-Wook;Reckhow, David A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.900-906
    • /
    • 2004
  • An RPLC-postcolumn detection method has been developed for the fluorimetric determination of dichloroacetamide (DCAD) in water. After ammonia and DCAD were separated on a $C_{18}$ nonpolar stationary phase with 2.5% methanol-0.02 M phosphate buffer at pH 3, the column eluant was reacted with post column reagents, o-phthaldialdehyde (OPA) and sulfite ion at pH 11.5, to produce a highly fluorescent isoindole fluorophore, which was measured with a fluorescence detector ( ${\lambda}_{ex}$ = 363 nm, ${\lambda}_{em}$ = 425 nm). With the optimized conditions for RPLC and the postcolumn derivatization, the calibration curve was found to be linear in the concentration ranges of 0.5 and 20 ${\mu}$M for DCAD, and the detection limit for DCAD was 0.18 ${\mu}$M (23${\mu}$g/L). This corresponded to 18 pmol per 100 ${\mu}$L injection volume for a signal-to-noise ratio of 3, and the repeatability and reproducibility of this method were 1.0% and 2.5% for five replicate analyzes of 2 ${\mu}$M DCAD, respectively. The degradation yields DCAD to ammonia were 94 and 99%, and the percent recoveries of DCAD from 4 and 6 ${\mu}$M DCAD-spiked tap water were shown mean more than 97%.

Investigation on the performance of the six DOF C.G.S., Algeria, shaking table

  • Aknouche, Hassan;Bechtoula, Hakim;Airouche, Abdelhalim;Benouar, Djillali
    • Earthquakes and Structures
    • /
    • v.6 no.5
    • /
    • pp.539-560
    • /
    • 2014
  • Shaking tables are devices for testing structures or structural components models with a wide range of synthetic ground motions or real recorded earthquakes. They are essential tools in earthquake engineering research since they simulate the effects of the true inertial forces on the test specimens. The destructive earthquakes that occurred at the north part of Algeria during the period of 1954-2003 resulted in an initiative from the Algerian authorities for the construction of a shaking simulator at the National Earthquake Engineering Research Center, CGS. The acceleration tracking performance and specifically the inability of the earthquake simulator to accurately replicate the input signal can be considered as the main challenge during shaking table test. The objective of this study is to validate the uni-axial sinusoidal performances curves and to assess the accuracy and fidelity in signal reproduction using the advanced adaptive control techniques incorporated into the MTS Digital controller and software of the CGS shaking table. A set of shake table tests using harmonic and earthquake acceleration records as reference/commanded signals were performed for four test configurations: bare table, 60 t rigid mass and two 20 t elastic specimens with natural frequencies of 5 Hz and 10 Hz.

Fabrication of Nano Master with Anti-reflective Surface Using Aluminum Anodizing Process (양극산화공정을 이용한 반사방지 성형용 나노 마스터 개발)

  • Shin, H.;Park, Y.;Seo, Y.;Kim, B.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.697-701
    • /
    • 2009
  • A simple method for the fabrication of porous nano-master for the anti-reflection effect on the transparent substrates is presented. In the conventional fabrication methods for antireflective surface, coating method using materials with low refractive index has usually been used. However, it is required to have a high cost and long processing time for mass production. In this paper, we developed a porous nano-master with anti-reflective surface for the molding stamper of the injection mold, hot embossing and UV imprinting by using the aluminum anodizing process. Through two-step anodizing and etching processes, a porous nano-master with anti-reflective surface was fabricated at the large area. Pattern size Pore diameter and inter-pore distance are about 130nm and 200nm, respectively. In order to replicate anti-reflective structure, hot embossing process was performed by varying the processing parameters such as temperature, pressure and embossing time etc. Finally, antireflective surface can be successfully obtained after etching process to remove selectively silicon layer of AAO master.

  • PDF

The Use of Meat Meal as a Dietary Protein Source Replacing Fish Meal in Juvenile Rockfish Sebastes schlegeli

  • Lee, Yong-Whan;Lee, Sang-Min
    • Journal of Aquaculture
    • /
    • v.18 no.2
    • /
    • pp.92-97
    • /
    • 2005
  • This study examined the partial replacement of the fish meal with meat meal in practical diets for juvenile rock-fish. Five isonitrogenous (48% CP) diets were prepared to contain meat meal at 0% (control), 10%, 20%, 30% and 40% with substituting the mackerel meal in the control diet. Three replicate groups of fish (initial average weight, 4.1g) were hand-fed to visual satiety two times daily for 8 weeks. Survival (>93%) and daily feed intake were not significantly different (P>0.05) among treatments. The best weight gain, feed efficiency and protein efficiency ratio were obtained from fish fed the diets containing 0% and 10% meat meal, and were not significantly different (P>0.05) to those of fish 134 diet containing 20% meat meal. Condition factor, visceralsomatic index and hepatosomatic index were not influenced by dietary meat meal levels. The contents of crude protein and ash of whole body were not significantly affected (P>0.05) by dietary meat meal levels, whereas crude lipid content of fish fed the diets containing 30% and 40% was lower than that of fish fed the control diet. Proximate composition of liver was not influenced by dietary meat meal level (P>0.05). The data obtained in this study indicate that a diet containing $10{\sim}20%$ meat meal could be used for least-cost formulation in juvenile rockfish diet.

Flame Atomic Absorption Spectrometric Determination of Ultra Traces of Thallium(I) ion after Solid Phase Extraction by Octadecyl Silica Membrane Disk Modified by a New Schiff Base

  • Mashhadizadeh, Mohammad Hossein;Moatafavi, Ali;Allah-Abadi, Hossein;Zadmehr, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.9
    • /
    • pp.1309-1313
    • /
    • 2004
  • A simple and reliable method has been developed to selectively separate and concentrate trace amounts of thallium ion from real samples for the subsequent measurement by flame atomic absorption spectrometry (FAAS). Thallium ions are absorbed quantitatively during passage of aqueous real samples through an octadecyl bonded silica membrane disk modified by 4-(4-Chloro-phenylazo)-2-[(4-hydroxy-phenylamino)-methyl]-phenol. The retained $Tl^+$ ions are then stripped from the disk quantitatively with a minimal amount of thiosulfate solution as eluent. The proposed method permitted large enrichment factors of about 130 and higher. The relative standard deviation for ten replicate extraction of thallium from 1 L samples containing 5 ${\mu}g$ thallium is 1.2%. The break through volume for 5 ${\mu}g$ thallium is 1000 mL. The limit of detection of the proposed method is 11.2 ng of $Tl^+$ per 1000 mL. The effects of various cationic interferences on the recovery of thallium in binary mixtures were studied. The method was applied to the recovery of $Tl^+$ ions from natural water and human hair samples.

Political image of women presidents and the phenomenon of fashion politics -A Study on Cristina Fernández de Kirchner- (여성 대통령의 정치 이미지와 패션 폴리틱스 현상 -Cristina Fernández de Kirchner 사례 연구-)

  • Kim, Mikyung
    • Journal of Fashion Business
    • /
    • v.19 no.5
    • /
    • pp.17-33
    • /
    • 2015
  • The purpose of this study was to evaluate the role of political image and the phenomenon of fashion politics on the style of women presidents, with focus on the President of Argentina, Cristina Fernandez de Kirchner. The results of the study were as follows. First, the political image of President Cristina Fernandez is identified with the second image of Eva Peron and Kirchnerismo, in terms of political issues. Second, fashion style includes the power and sexy images of glamour style that emphasizes the body line of suits and dress form. Vivid colors and black fashion reflects the Kirchner government's charisma and identity. Fernandez's iconic Rolex watches, expensive jewelry, and luxury accessories such as brooches that replicate Eva Peron's brooch were instrumental in forming a second image of Eva Peron. Third, the phenomenon of fashion politics appeared to equate the phenomenon of recreating the image of Eva Peron with displays of power and wealth for the successor to Kirchnerismo.

pVC, a Small Cryptic Plasmid from the Environmental Isolate of Vibrio cholerae MP-1

  • Zhang, Ruifu;Wang, Yanling;Leung, Pak Chow;Gu, Ji-Dong
    • Journal of Microbiology
    • /
    • v.45 no.3
    • /
    • pp.193-198
    • /
    • 2007
  • A marine bacterium was isolated from Mai Po Nature Reserve of Hong Kong and identified as Vibrio cholerae MP-1. It contains a small plasmid designated as pVC of 3.8 kb. Four open reading frames (ORFs) are identified on the plasmid, but none of them shows homology to any known protein. Database search indicated that a 440 bp fragment is 96% identical to a fragment found in a small plasmid of another V. cholerae. Further experiments demonstrated that a 2.3 kb EcoRI fragment containing the complete ORF1, partial ORF4 and their intergenic region could self-replicate. Additional analyses revealed that sequence upstream of ORF1 showed the features characteristic of theta type replicons. Protein encoded by ORF1 has two characteristic motifs existed in most replication initiator proteins (Rep): the leucine zipper (LZ) motif located at the N-terminal region and the alpha helix-turn-alpha helix motif (HTH) located at the C-terminal end. The results suggest that pVC replicates via the theta type mechanism and is likely a novel type of theta replicon.

Detection and Identification of the Series Arc in an Indoor Wiring System (옥내 배선계통에서 직렬 아크의 검출과 판별)

  • Kim, Woo-Hyun;Wang, Guoming;Kil, Gyung-Suk;Ji, Hong-Keun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.412-416
    • /
    • 2018
  • Most series arcs lead to electrical fires that cannot be interrupted by circuit breakers, because the arc's current is outside the breaker's operating range. In this paper, experiments were conducted on the detection and identification of series arcs to prevent electrical fires. Plugs and outlets specified in KS C 8305 were deteriorated to replicate arc faults commonly found in fields. The characteristics of series arcs resulting from various types of loose connections were determined by analyzing the frequency spectra and phase distributions of detected arc pulses. The results showed that the simulated arc defects used in this study were more similar to actual arc phenomena than the existing arc generator specified in UL 1699. In addition, loose connections, such as wire-wire, terminal-wire, and outlet-plug, can be identified by phases of $0^{\circ}$, $180^{\circ}$ and $360^{\circ}$, respectively. These phases can be detected by a band pass filter with a frequency range of 5~10 MHz, which can be used as the trip signal for circuit breakers.

New Material and Processing Issues for High Quality Parts by Micro-MIM

  • Rota, A.;Imgrund, Ph.;Haack, J.;Petzoldt, F.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.34-35
    • /
    • 2006
  • The development of Micro MIM as a new manufacturing process for metallic micro parts made of advanced functional materials has been the subject of considerable research over the last years. This paper addresses important quality aspects on processing of new materials by Micro-MIM. Three examples of new functional materials that can be processed are reviewed in this paper. The first example is two-component-Micro-MIM to obtain multi-functional devices. A micro positioning encoder consisting of a magnetic / non-magnetic material combination is presented. The second issue is series production of the replicate of the smallest human bone in the ear (stapes) from Titanium as an example of medical application. Quality assurance and reproducibility in terms of injection moulding parameters are addressed. In the third part, first results on the processing of the shape memory alloy NiTi by Micro-MIM are presented. Potential applications include biocompatible devices and transportation, for example automotive and aerospace. Processing routes and initial microstructures obtained are discussed.

  • PDF

A study on development of plastic vial tube for the DNA detection process (DNA 검출 공정 전용 플라스틱 튜브형 시험관 개발에 관한 연구)

  • Choi, Kyu-wan;La, Moon-woo;Gang, Jung-hee;Chang, Sung-ho
    • Design & Manufacturing
    • /
    • v.11 no.3
    • /
    • pp.35-40
    • /
    • 2017
  • PCR(Polymerase chain reaction) is a technique to replicate and amplify a desired part of DNA. It is used in various aspects such as DNA fingerprint analysis and rare DNA amplification of an extinct animal. Especially in the medical diagnosis field, it provides various measurement methods at the molecular level such as genetic diagnosis, and is a basic tool for molecular diagnostics. The internal shape of the plastic vial tube for PCR analysis used in the DNA detection process, and the surface roughness and internal cleanliness can affect detection and discrimination results. The plastic vial tube demanded by the developer of the PCR analysis equipment should be changed to a structure that eliminates the residual washing solution in the washing process to ensure the internal cleanliness. Thus the internal structure and the internal surface design for improving the PCR amplification efficiency are key issues to develop the plastic vial tube for the DNA detection process.