• Title/Summary/Keyword: Replica pattern

Search Result 44, Processing Time 0.018 seconds

Design and Fabrication of Multi-Focusing Microlens Array with Different Numerical Apertures by using Thermal Reflow Method

  • Park, Min-Kyu;Lee, Ho Jun;Park, Ji-Sub;Kim, Mugeon;Bae, Jeong Min;Mahmud, Imtiaz;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.71-77
    • /
    • 2014
  • We present design and fabrication of a multi-focusing microlens array (MLA) using a thermal reflow method. To obtain multi-focusing properties with different numerical apertures at the elemental lens of the MLA, double-cylinder photoresist (PR) structures with different diameters were made within the guiding pattern with both photolithographic and partial developing processes. Due to the base PR layer supporting the thermal reflow process and the guiding structure, the thermally reflowed PR structure had different radii of curvatures with lens shapes that could be precisely modeled by the initial volume of the double-cylinder PR structures. Using the PR template, the hexagonally packed multi-focusing MLA was made via the replica molding method, which showed four different focal lengths of 0.9 mm, 1.1 mm, 1.6 mm, and 2.5 mm, and four different numerical apertures of 0.1799, 0.2783, 0.3973, and 0.4775.

Creative Direction for Maison Margiela - John Galliano as a Case Study - (메종 마르지엘라의 크리에이티브 디렉션에 관한 고찰 - 존 갈리아노를 중심으로 -)

  • Lee, Hyun-Jung;Yim, Eun-Hyuk
    • Fashion & Textile Research Journal
    • /
    • v.24 no.2
    • /
    • pp.173-182
    • /
    • 2022
  • As consumption pattern and fashion communication become digitalized, fashion houses are being inherited by creative directors owing to their expanding role. While the roles and responsibilities of creative directors have been changing extensively along with the dynamic nature of the fashion industry, researches on creative directions have mostly focused on luxury brands. This study examined the creative direction of John Galliano for Maison Margiela, a conceptual brand to be maintained by a creative director. To analyze this, the authors established a creative direction analysis model constituting five elements: brand heritage, trend, democratization, brand status, and persona, drawing on the luxury brand architecture by Kapferer and Bastien. Thus, Galliano has maintained anonymity as a heritage of Maison Margiela, expanding the existing Replica lines, and introduced fashion shows focusing on current issues or social phenomena. As a democratization strategy, he directed the brand to associate with more popular brands or expanded diffusion lines to secure broader customer base, while demonstrating couturier-like showmanship in the media and establishing his own persona. His direction for Maison Margiela recreates and expands brand heritage by transforming the brand philosophy. Therefore the new creative direction communicates with the wider public and diversifies customer bases through democratization strategies, while building Galliano's own persona.

AN EXPERIMENTAL STUDY ON THE ETCHING PATTERNS AND THE PENETRATION OF THE COMPOSITE RESIN TO HUMAN DECIDUOUS ENAMEL ETCHED WITH PHOSPHORIC ACID (인산(燐酸) 부식(腐蝕)에 의(依)한 유치(乳齒) 표면(表面) 변화(變化) 및 복합(複合)레진 침투(浸透)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Shin, Wan-Young;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.10 no.1
    • /
    • pp.85-93
    • /
    • 1983
  • In one group that tested for the effects of grinding and etching on the deciduous teeth, S.E.M. examination on the ground or unground labial surface of deciduous maxillary central incisors were made after etching procedure with 40% phosphoric acid for 60 secs., 120 secs., 180 sees. each. In another group that tested for the degree of resin penetration to the ground and etched deciduous teeth, composite resin application was done to the ground deciduous maxillary central incisors that had been acid-etched for 30 secs., 60 secs., 90 sees., 120 sees., 180 secs. each. The tooth-resin specimens were cut at the middle 1/3 of the crown by 2mm thickness, and the adjacent tooth materials were demineralized by 10% hydrochloric acid, the author observed the tags of the resin replica with S.E.M.. Following results were obtained. 1. After 40% phosphoric acid etching, the unground deciduous enamel surface showed various types of etching pattern. 2. For the formation of regular micropores on deciduous enamel surface by acid etching with 40% phosphoric acid, the time over 120 secs. should be requested. 3. After 40% phosphoric acid etching, the ground deciduous enamel surface showed the same etching pattern that has been a preferential removal of prism peripheries despite different etching time. 4. On the ground group that etched over 60 secs. to 180 secs., the length of tags was $5{\mu}m$ to $8{\mu}m$, with a mean of $7{\mu}m$.

  • PDF

Functional Underwear Development for Elderly Woman from 3D Body Model applying PCM treatment (PCM 가공과 3차원 인체 모델링 기술을 적용한 노년 여성용 기능성 언더웨어 설계)

  • Choi, Sin-Ae;Kim, Tae-gyou;Park, Youong-Min;Shin, Ji-Young;Park, Soonjee
    • Fashion & Textile Research Journal
    • /
    • v.18 no.4
    • /
    • pp.457-467
    • /
    • 2016
  • This study aimed to develop functional underwear for elderly women in their sixties in terms of good fit, wear comfort and body temperature regulation. To satisfy elderly women's physical and metabolical needs, an automatic temperature control system via PCM treatment was applied. Underwear pattern was produced by producing body surface replica, which was derived from 3D body parametric model. Differential ratios of outline length and area between 3D surface and 2D plane were 1.4% and 0.5%, respectively. The reduction rate was determined as 10% through the expert's evaluation. PCM treated fabric showed higher Q-max, meaning that it can facilitate the thermal transition in hot situation. Moreover, it also showed higher insulation to preserve heat and keep warm microclimate in a cold weather. Heat distribution measurements on various body parts revealed that the temperature after PCM treatment was significantly higher. The clothing pressure after 10% pattern reduction showed higher before reduction, at the same time, even lower than the comfort clothing pressure range of $5{\sim}10gf/cm^2$, implying that experimental garment of this research is acceptable in terms of clothing pressure. Evaluation results on the comfort to move in various motions proved that adequate clothing pressure improved the wear comfort in various motions.

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

Development of Wireless ECG Clothing for Dogs with Improved Signal Detection (신호 감지성이 향상된 반려견용 무선 심전도 측정 의복 개발)

  • Kim, Soyoung;Lee, Okkyung;Kwon, Eunsun;Lee, Yejin;Min, Seungnam;Lee, Heeran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.760-771
    • /
    • 2022
  • This study sought to develop clothing for a companion animal that can provide stable ECG measurements. A pattern for the smart clothing of a companion dog was manufactured using the replica method to select a location and method that best suited the stable measurement of ECG and improved the clothing's fitness. The smart clothing was developed as the following three types: strap type, top type, and combined top and vest type with a detachable wireless ECG monitor. The detection abilities of these were observed using the PQRST rate taken after ECG measurements while the three companion dogs were tested while resting and moving. The results revealed that apart from using an electrode, applying a gel pad is the most effective way to achieve stable ECG measurements, and the central chest region is more reliable than the left armpit for providing steady readings. The combined top and vest type showed the highest average ECG PQRST detection number, meaning that the ECG signal measurement was steady. These results may contribute to the measurement of ECG in smartwear for U-Healthcare to measure other biometric data of a companion dog.

A New Sample Preparation Technique for SEM Observation of Polyolefin Microstructure (주사전자현미경상에서의 고분자 미세구조 관찰)

  • Park, Je-Myung
    • Applied Microscopy
    • /
    • v.29 no.4
    • /
    • pp.405-415
    • /
    • 1999
  • In general, transmission electron microscopy (TEM) is usually used in the investigation of polymer microstructure. Microtoming, solution casting, staining and carbon replica method are frequently introduced to the study of the polymer morphology with TEM, however the sample preparation procedure of those techniques is very difficult, and it takes a long time. The purpose of this study is to develop a new sample preparation technique which is suitable for the investigation of the various shapes and species of polyolefin microstructure by scanning electron microscopy (SEM). By modifying the conventional chemical etching method, we developed a new chemical etching technique and sample preparation procedure that are suitable for SEM study of polymer microstructure. In this study the permanganate etching method is introduced and the optimum etching condition are determined by simply adjusting the etchant formulation, concentration and etching time. This technique has shown good reproducibility and it's morphological results agree well with other works on various types of microstructures such as spherulite characterization of isotatic polypropylene $(\alpha/\beta)$, polyethylene and poly-propylene copolymer characterization, and the study of lamellar growth pattern of unsheared or oriented materials. This technique has also been applied to the industrial fields for characterization of the polyolefin film, automobile products and the others.

  • PDF

Development of bio-inspired hierarchically-structured skin-adhesive electronic patch for bio-signal monitoring (생체정보 진단을 위한 생체모사 계층구조 기반 피부 고점착 전자 패치 개발)

  • Kim, Da Wan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.749-754
    • /
    • 2022
  • High adhesion and water resistance of the skin surface are required for wearable and skin-attachable electronic patches in various medical applications. In this study, we report a stretchable electronic patch that mimics the drainable structure pattern of the hexagonal channels of frog's pads and the sucker of an octopus based on carbon-based conductive polymer composite materials. The hexagonal channel structure that mimics the pads of frogs drains water and improves adhesion through crack arresting effect, and the suction structure that mimics an octopus sucker shows high adhesion on wet surfaces. In addition, the high-adhesive electronic patch has excellent adhesion to various surfaces such as silicone wafer (max. 4.06 N/cm2) and skin replica surface (max. 1.84 N/cm2) in dry and wet conditions. The high skin-adhesive electronic patch made of a polymer composite material based on a polymer matrix and carbon particles can reliably detect electrocardiogram (ECG) in dry and humid environments. The proposed electronic patch presents potential applications for wearable and skin-attachable electronic devices for detecting various biosignals.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Comparison of the fit of the coping pattern constructed by manual and CAD/CAM, depending on the margin of the abutment tooth (지대치 변연 형태에 따른 수작업과 CAD/CAM으로 제작한 coping 패턴의 적합도 비교)

  • Han, Min-soo;Kwon, Eun-Ja;Chio, Esther;Kim, Si-chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6611-6617
    • /
    • 2015
  • The purpose of this study is to compare the marginal and internal fit of metal and zirconia coping which is fabricated by manual and CAD/CAM(Computer Aided Design/Computer Aided Manufacturing). The model is prepared with Urethane material and two abutment teeth are fabricated with a knife and chamfer margin. Silicon replica technique is used to measure the marginal fit of manually fabricated and the CAD/CAM coping. Internal fitting level is measured with a microscope and the image is captured with a CCD camera. The distance between abutment teeth and coping is measured with a callibrated image analyzer software; marginal opening (MO), marginal gap (MG), internal gap (IG) at maximum curvature area, axial gap (AG), and occlusal gap (OG). Two-way ANOVA test is applied to compare fabrication technique and to analysis of abutment pattern. In addition, one-way ANOVA and Scheffe's test is used to analyze each parameter of the test. The result shows that the fit is < $120{\mu}m$ except OG of CAD/CAM and MO of knife margin. The CAD/CAM fabricated coping showed higher fit level at chamfer margin. However, knife margin showed better fitness compared to chamfer margin at MG. AG showed the minimum dimension with a constant result (< $38{\mu}m$).