• Title/Summary/Keyword: Replica Parameter

Search Result 14, Processing Time 0.035 seconds

A Active Replica LDO Regulator with DC Matching Circuit (DC정합회로를 갖는 능동 Replica LDO 레귤레이터)

  • Ryu, In-Ho;Bang, Jun-Ho;Yu, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2729-2734
    • /
    • 2011
  • In this paper, an active replica Low-dropout(LDO) regulator with DC voltage matching circuit is presented. In order to match the voltage between replica and output of regulator, DC voltage matching circuit is designed. The active replica low dropout regulator has higher Power Supply Rejection(PSR) than that of conventional regulator. The designed DC voltage matching circuit can reduce the drawback that may be occurred in replica regulator. And using fully active element in regulator can reduce the chip area and heat noise with resistor. As results of HSPICE simulation with 0.35um CMOS parameter, the designed active replica LDO regulator achieves Power Supply Rejection, -28@10Hz better than -17@10Hz of conventional replica regulator without DC matching circuit. And the output voltage is 3V.

A Study on the Effects of Parameter Sensitivity on Matched Field Processing

  • Park, Cheolsoo;Woojae Seong;Park, Hang-Soon;Lee, Kyu-Yeul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.1E
    • /
    • pp.31-37
    • /
    • 2001
  • Matched Field Processing (MFP) is a successive process of correcting mismatches between true and assumed parameters by matching the measured acoustic field data with numerically simulated data which we call replica. The MFP is widely used both in geo-acoustic parameter inversions and in source localizations. Whether a certain parameter can be inverted effectively or whether a source can be localized correctly depends on the amount of the influence that a parameter has on the acoustic field during the matching process. Sensitive parameters can be better estimated than the less sensitive ones in MFP. On the contrary, the sensitive parameters affect adversely on the source localization results when they have uncertainties. In this paper, a sensitivity index is defined based upon the field variation resulting from the perturbed parameters. Numerical test results show that the index behaves in accordance with the results of source localization under a mismatched environment and also with the inversion solutions.

  • PDF

Modeling and simulation of foxboro control system for YGN#3,4 power plant (영광 3,4호기 Foxboro 제어시스템 모델링 및 시뮬레이션)

  • 김동욱;이용관;유한성
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.179-182
    • /
    • 1997
  • In a training simulator for power plant, operator's action in the MCR(Main Control Room) are given to plant process and computer system model as an inputs, and the same response as in real power plant is provided in real time. Inter-process communication and synchronization are especially important among various inputs. In the plant simulator, to simulate the digital control system such as FOXBORO SPEC-200 Micro control system, modification and adaptation of control card(CCC) and its continuous display station(CDS) is necessary. This paper describes the modeling and simulation of FOXBORO SPEC-200 Micro control system applied to Younggwang nuclear power plant unit #3 & 4, and its integration process to the full-scope replica type training simulator. In a simulator, display station like CDS of FOXBORO SPEC-200 Micro control system is classified as ITI(Intelligent Type Instrument), which has a micro processor inside to process information and the corresponding alphanumeric display, and the stimulation of ITI limits the important functions in a training simulator such as backtrack, replay, freeze and IC reset. Therefore, to achieve the better performance of the simulator, modification of CDS and special firmware is developed to simulate the FOXBORO SPEC-200 Micro control system. Each control function inside control card is modeled and simulated in generic approach to accept the plant data and control parameter conveniently, and debugging algorithms are applied for massive coding developed in short period.

  • PDF

Computational Study on Oligomer Formation of Fibril-forming Peptide of α-Synuclein

  • Park, Seong-Byeong;Yoon, Je-Seong;Jang, Soon-Min;Lee, Kyung-Hee;Shin, Seok-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.848-854
    • /
    • 2012
  • We have studied the oligomerization of a fibril-forming segment of ${\alpha}$-Synulcein using a replica exchange molecular dynamics (REMD) simulation. The simulation was performed with trimers and tetramers of a 12 amino acid residue stretch (residues 71-82) of ${\alpha}$-Synulcein. From extensive REMD simulations, we observed the spontaneous formation of both trimer and tetramer, demonstrating the self-aggregating and fibril-forming properties of the peptides. Secondary structure profile and clustering analysis illustrated that antiparallel ${\beta}$-sheet structures are major species corresponding to the global free energy minimum. As the size of the oligomer increases from a dimer to a tetramer, conformational stability is increased. We examined the evolution of simple order parameters and their free energy profiles to identify the process of aggregation. It was found that the degree of aggregation increased as time passed. Tetramer formation was slower than trimer formation and a transition in order parameters was observed, indicating the full development of tetramer conformation which is more stable than that of the trimer. The shape of free energy surface and change of order parameter distributions indicate that the oligomer formation follows a dock-and-lock process.

A STUDY OF HYDRAULIC PROPERTIES IN A SINGLE FRACTURE WITH IN-PLANE HETEROGENEITY: AN EVALUATION USING OPTICAL MEASUREMENTS OF A TRANSPARENT REPLICA

  • Sawada, Atsushi;Sato, Hisashi
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • Experimental examinations for evaluating fracutres were conducted by using transparent replicas of a single fracture in order to obtain the fracture data to contribute to the methodlogy on how to improve the definitaion of representative parameter values used for a parallel plate fracture model. Quantitative aperture distribution and quantitative tracer concentration data at each point in time were obtained by measuring the attenuation of transmitted light through the fracture in high spatial resolution. the representative aperture values evaluated from the multiple different measurement methods, such as arithmetic mean of aperture distribution measured by the optical method, transport aperture evaluated from the tracer test, and average aperture evaluated from the fracture void volume measurement converged to a unique value that indicates the accuracy of this experimental study. The aperture data was employed for verifying the numerical simulation under the assuption of Local Cubic Law and showed that the calculated flow rate through the fracture is 10%-100% larger than hydraulic test results. The quantitative tracer concentration data is also very valuable for validating existing numerical code for advection dispersion transport in-plane heterogeneous fractures.

Adaptive Fuzzy Drop Manager for Service of Reliable Distribution Application Domain Objects (신뢰성 있는 분산 도메인 객체 서비스를 위한 적응형 퍼지 드럽 관리기)

  • Jeong, Taeg-Won;Lee, Chong-Deuk
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.4
    • /
    • pp.511-518
    • /
    • 2009
  • A lot of methods are proposed to provide services for object informations in distributed domain to satisfy the recent increase of user-centered services. This paper proposed a method called fuzzy drop manager for the service of reliable distribution application domain objects. The proposed system accesses the domain using replica parameter ci,j and access matrix Z, and evaluates the reference relatedness inside the domain using the relatedness, given by the mapping of intra-domain fuzzy relevance, between fuzzy sets. Objects in the domain generated an $\alpha$-level set according to the reference relatedness obtained by applying $\alpha$-level to extend queries. Simulation results showed that the proposed method has better performance than the other methods.

Skin Wrinkle Detection Using Dermatologic Magnifier Based on Variable Polarization and Optical Magnification (가변편광과 광학배율을 기반으로 한 피부 확대경을 이용한 피부주름 측정)

  • Bae, Young-Woo;Jung, Byung-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.190-192
    • /
    • 2006
  • The clinical characteristics of photodamaged skin, such as coarse and fine wrinkle are not accurately evaluable with previous methods. Public awareness for wrinkle treatment and prevention which rely on proper assessment and evaluation of the underlying skin changes has been increased as the population ages. In this paper, we suggest an in-vivo method and instrument that allow us to acquire a wrinkle-enhanced image to improve the accuracy of quantitative and qualitative analysis for skin wrinkle. The method used involved white LED illumination and photography through polarizing filters. Finally, the polarized light photography yields an accurate and evaluable parameter of photodamaged skin, especially fine and coarse wrinkle.

  • PDF

Parameter Mismatches and its Biases in Ocean Matched Field Processing (해양 정합장처리에서 매개변수 오정합과 바이어스)

  • Park Jae-Eun;Kim Jea-Soo;Shin Kee-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.87-96
    • /
    • 2005
  • In matched field processing (MEP), the observed acoustic field data is basically correlated with the replica produced by the modeling. therefore the results of source localization and correlation is limited by the mismatch of the environment and sensor location. In this paper. the effects of mismatch in environment and system on the bias in estimating the source location are investigated in the context of source localization. In the Pekeris waveguide, the simulation shows that the mismatches in environment and system, can cause a significant biases in the source localization and a degradation in MFP correlation. Mismatch caused by uncertainties in array tilt and depth, bottom depth, bottom sound speed, etc. causes degradation in source localization performance.

Co-Channel Interference Cancellation in Cellular OFDM Networks - PART I : Maximum-Likelihood Co-Channel Interference Cancellation with Power Control for Cellular OFDM Networks

  • Mohaisen, Manar;Chang, Kyung-Hi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5A
    • /
    • pp.409-416
    • /
    • 2007
  • In cellular orthogonal frequency division multiplexing (OFDM) networks, co-channel interference (CCI) leads to severe degradation in the BER performance. To solve this problem, maximum-likelihood estimation (MLE) CCI cancellation scheme has been proposed in the literature. MLE CCI cancellation scheme generates weighted replicas of the transmitted signals where weights represent the estimated channel transfer functions. The replica with the smallest Euclidean distance from the received signal is selected and data are detected. When the received power of the desired and interference signals are nearly the same, the BER performance is degraded. In this paper, we propose a closed-loop power control (PC) scheme capable of detecting the equal received power situation at the mobile station (MS) receiver by using the newly introduced parameter power ratio (PR). When this situation is detected, the MS sends a feedback to the desired base station (BS) which boosts the transmission power in the next frame. At cell edge where signal to interferer ratio (SIR) is considered to have average value between -5 dB and 10 dB, computer simulations show that the proposed CCI cancellation scheme has a gain of 7 dB at 28 Km/h.

Fatigue behavior of Cr-Mo-V steel at high temperature for turbines -Propagation characteristics of high cycle fatigue crack- (터빈용 Cr-Mo-V강의 고온 환경변화에 따른 피로거동-고사이클 피로균열의 전파특성-)

  • Song, Sam-Hong;Kang, Myung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.69-76
    • /
    • 1997
  • The rotating bending fatigue tests were performed using the specimens taken from Cr-Mo-V steel, widely sued in thermal power plant turbines, at various temperatures such as room temperature, 300 .deg. C, 425 .deg. C and 550 .deg. C. The characteristics of fatigue crack propagation were examined and analyzed by using fracture mechanics parameter. The plastic replica method was also applied in order to measure the crack length on the basis of serial observation of fatigue crack propagation behavior on the defected specimen surface. The fatigue crack propagation behavior of Cr-Mo-V steel was investigated within the frame work of elastic-plastic fracture mechanics. The propagation law of fatigue crack is obtained uniquely by using the term .sigma. $^{n}$ sub a/where .sigma. $_{a}$ is the service stress, a is the crack length and n is a constant. The values of constant n are nearly equal to 2.48, 2.60 and 8.61 at room temperature, 300 .deg. C and 425 .deg. C.

  • PDF