• 제목/요약/키워드: Repetition Time

검색결과 459건 처리시간 0.031초

현대패션디자인에 나타난 비표상성 (Non-Representation Expressed in Contemporary Fashion Design)

  • 임민정
    • 한국의상디자인학회지
    • /
    • 제25권1호
    • /
    • pp.153-168
    • /
    • 2023
  • Non-representation creates difference and change that can be used as a creative design method that satisfies contradictory requirements for similarity and differentiation. This study drew upon the characteristics of the concept of non-representation expressed in contemporary art and architecture, in which Gilles Deleuze's philosophical thinking was reflected, and analyzed the non-representation depicted in contemporary fashion. The non-representation expressed in contemporary art and architecture is as follows. Non-representation of delaying becoming focuses on reverting to preexisting objects and redefining traditional meaning, thereby delaying the representation of latent meaning. Non-representation of non-becoming removes existing values and typical forms and expresses amorphousness. Non-representation of becoming by repetition or reiteration realizes the difference caused by the passage of time by repeating or overlapping shapes. Non-representation of becoming expresses the transformation of space by flowing through time rather than by actual movement. Non-representation in contemporary fashion shows the following expression characteristics. First, the non-representation of deferring becoming deconstructs the traditional values and forms of clothing and expresses designs by displacement or juxtaposition. Second, the non-representation of non-becoming is expressed concepts unrelated to the body and focus upon amorphous objects that do not become concretized forms. Third, generative non-representation by repetition and overlap expresses the possibility of change by overlapping clothing items or details expressed by repeating segmented objects. Fourth, generative non-representation by movement reproduces the meaning of space and time by moving the shape of the clothing or visually changing the surface of the material of clothing. As a result of the study, the non-representation shown in contemporary fashion aims for versatility to conform to social changes. This study provides new insight into the fashion design method by increasing the understanding of the cocnept of non-representation and showing its potential.

옻나무 추출액의 염색성 (A Study on the Chemical and Dyeing Properties of Rhus Verniciflua Extract)

  • 김애순
    • 한국염색가공학회지
    • /
    • 제16권6호
    • /
    • pp.16-22
    • /
    • 2004
  • This study was carried out to investigate K/S values, surface color, the fastness to washing, bacteria reduction rate of the silk and cotton fabrics dyed with Rhus verniciflua extract under the various dyeing conditions. The optimum dyeing temperature, dyeing time, dyeing pH and repetition of the silk fabrics dyed with Rhus verniciflua extract were $l00^{\circ}C, 30min., pH 5, five times repetition respectively, but in the cotton fabrics, it were $60^{\circ}C . 30min., pH 7, one times repetition. It were colored orangish Yellow in the silk fabrics and colored bright yellow in the cotton fabrics dyed with Rhus verniciflua extract. Surface color(munsell value) was not changed by the mordanting agents but those of the silk showed high tone when mordanting with stannous chloride, and it was decolored and darked when mordanting with ferric sulfate. The fastness to washing in the silk fabrics dyed with mordanting agents improved in 4~5 grade, but the cotton fabrics were 3~4 grade, so washing fastness of the silk and cotton fabrics were significantly improved when washing with the neutral detergent. The bacteria reduction rate of the silk fabrics increased drastically by dyeing of Rhus verniciflua extract.

다중 공진형 컨버터를 이용한 이중 캐비티 구조의 4Hz 의료용 루비레이저 시스템 개발 (Development of 4Hz Medical Ruby Laser System with Double Cavities using Multi-Resonant Converter)

  • 이재철;정도;박성욱;허국성;김희제
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1207-1211
    • /
    • 2015
  • Various laser systems have been widely used in almost all industrial technologies because they have high energy density, directivity and coherence. Recently the clinical application is becoming wider in medical parts such as incurable disease, diagnosis and so on. Generally, ruby laser beam has the greatest efficacy for removing tattoos, freckle and other skin problem. But current medical ruby laser system has the maximum repetition rate of 2Hz and optical output beam energy of 1J. Many medical doctors really want to have a high repetition ruby laser system because that can reduce the operation time. We investigated a new ruby laser system with high repetition rate of 4Hz using double cavities. Furthermore, we develop a new power supply system adopting zero voltage switching(ZVS) to minimize switching loss by LLC resonant converter designed as 2kW class.

키토산과 녹차추출물을 이용한 인체친화적 자외선 차단 셀룰로오스 섬유의 개발 -키토산 매염과 녹차추출물 재염의 효과를 중심으로- (Developing Human-friendly UV Protective Cellulose Fabrics Using Chitosan and Green Tea Extract -Focusing on the Repetition Effect of Chitosan Mordanting and Green Tea Extract Dyeing-)

  • 정혜경;김신희
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.817-826
    • /
    • 2009
  • As UV radiation to the earth increased over recent years, many adverse effects of UV radiation have been reported. There are needs to develop UV-protective apparel and accessaries to protect skin from these harmful effects. Cellulose is one of the most frequently worn fiber during summer time. However, celllulose shows very low UV-protective property especially in case of thin and low fabric content. In this study, UV-protective cellulose textiles were developed using chiotsan mordanting and green tea dyeing. The repetition effect of chitosan and green tea treatment were focused. Three different cellulose fibers, cotton, linen, and ramie, were used for this study. All chitosan mordanted and green tea dyed fabrics showed increases in UV-protective property. The color of fabrics tended to darker as the numbers of mordanting process and green tea dyeing increased. UV-protective property did not increase significantly upon the repetition of mordanting and green tea dyeing treatment except ramie fabric. UV protective property was persisted upon washfastness test in all three cellulose fiber types.

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.

Adaptive-and-Resolvable Fractional Repetition Codes Based on Hypergraph

  • Tiantian Wang;Jing Wang;Haipeng Wang;Jie Meng;Chunlei Yu;Shuxia Wang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권4호
    • /
    • pp.1182-1199
    • /
    • 2023
  • Fractional repetition (FR) codes can achieve exact uncoded repair for multiple failed nodes, with lower computational complexity and bandwidth overhead, and effectively improve repair performance in distributed storage systems (DSS). The actual distributed storage system is dynamic, that is, the parameters such as node storage overhead and number of storage nodes will change randomly and dynamically. Considering that traditional FR codes cannot be flexibly applied to dynamic distributed storage systems, a new construction scheme of adaptive-and-resolvable FR codes based on hypergraph coloring is proposed in this paper. Specifically, the linear uniform regular hypergraph can be constructed based on the heuristic algorithm of hypergraph coloring proposed in this paper. Then edges and vertices in hypergraph correspond to nodes and coded packets of FR codes respectively, further, FR codes is constructed. According to hypergraph coloring, the FR codes can achieve rapid repair for multiple failed nodes. Further, FR codes based on hypergraph coloring can be generalized to heterogeneous distributed storage systems. Compared with Reed-Solomon (RS) codes, simple regenerating codes (SRC) and locally repairable codes (LRC), adaptive-and-resolvable FR codes have significant advantages over repair locality, repair bandwidth overhead, computational complexity and time overhead during repairing failed nodes.

칼만 필터를 사용한 레이더 펄스열 추적 (Tracking of Radar Pulse Train Using Kalman Filter)

  • 김용우;신욱현;이효섭;김홍필;양해원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.176-176
    • /
    • 2000
  • Generally, discrete-time processing is applied to the uniformly-sampled signals. But, radars emit pulse trains with irregular time instances. In this paper, we formulate the radar pulse train as a stochastic discrete-time dynamic linear model. The estimation task can be done via linear signal processing using Kalman Filter and some considerations. As a result, we can estimate the pulse repetition interval of a pulse train and predict the time instances of the next pulses to be received.

  • PDF

LEFT INFERIOR FRONTAL GYRUS RELATED TO REPETITION PRIMING: LORETA IMAGING WITH 128-CHANNEL EEG AND INDIVIDUAL MRI

  • Kim, Young-Youn;Kim, Eun-Nam;Roh, Ah-Young;Goong, Yoon-Nam;Kim, Myung-Sun;Kwon, Jun-Soo
    • 한국인지과학회:학술대회논문집
    • /
    • 한국인지과학회 2005년도 춘계학술대회
    • /
    • pp.151-153
    • /
    • 2005
  • We investigated the brain substrate of repetition priming on the implicit memory taskusing low-resolution electromagnetic tomography (LORETA) with high-density 128 channel EEG and individual MRI as a realistic head model. Thirteen right-handed, healthy subjects performed a word/nonword discrimination task, in which the words and nonwords were presented visually,and some of the words appeared twice with a lag of one or five items. All of the subjects exhibited repetition priming with respect to the behavioral data, in which a faster reaction time was observed to the repeated word (old word) than to the first presentation of the word (new word). The old words elicited more positive-going potentials than the new words, beginning at 200 ms and lasting until 500 ms post-stimulus. We conducted source reconstruction using LORETA at a latency of 400 ms with the peak mean global field potentials and used statistical parametric mapping for the statistical analysis. We found that the source elicited by the old words exhibited a statistically significant current density reduction in the left inferior frontal gyrus. This is the first study to investigate the generators of repetition priming using voxel-by-voxel statistical mapping of the current density with individual MRI and high-density EEG.

  • PDF

치과진료실에서의 감염관리 실태 조사 (A study on the state of infection control in dental clinic)

  • 김경미;정재연;황윤숙
    • 한국치위생학회지
    • /
    • 제7권3호
    • /
    • pp.213-230
    • /
    • 2007
  • The purpose of this study was to examine the state of infection control provided to members of Korean Dental Hygienists Association. The subjects in this study were dental hygienists who attended a symposium on July 1. 2006. after a survey was conducted, the answer sheets from 489 participants were analyzed, and the findings of the study were as follows: 1. Possession of disinfection room was being(72.7%), and person of infection control was zero(52.9%). Number of sterilizer was one(62.2%). 2. As a repetition choice, type of sterilizer was autoclave(97.9%), UV sterilizer(67.4%) and EO gas sterilizer(21.4%). As a repetition choice, infection materials was ethanol(84.1%). 3. Water tube of unit and chair was using of sterilized water(42.9%). Sterilizing of compressed air was no(69.0%). 4. Re-using of disposal was not using(62.5%), re-using disposal was suction tip(28.2%)(repetition choice) 5. In sterilization of instruments, hand-piece was every using time(28.4%), and reamer-file, bur, mirror, pincette, explorer, hand scaler and ultrasonic scaler were high in every using time. 6. Individual protection was high of using, cleaning of hands before treatment was every treatment(87.0%). Type of soap was liquid type in dental clinic(48.2%), infection soap in dental hospital(41.2%) and solid soap in public health center(50.6%). Answered that they need regular oral health education, and 82.9% respondents answered that they need oral health technicians in school. And 87.8% respondents needed individual oral health education for the benefit of better oral health.

  • PDF

저온 플라즈마 공정용 펄스발생 전원장치의 성능시험 (Test Results of Pulsed Power Supply for Nonthermal Plasma Process)

  • 장성덕;변영철;조무현;신동남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF