• Title/Summary/Keyword: Repetition Time

Search Result 459, Processing Time 0.025 seconds

Impulse Based TOA Estimation Method Using Non-Periodic Transmission Pattern in LR-WPAN (LR-WPAN에서 비주기적 전송 패턴을 갖는 임펄스 기반의 TOA 추정 기법)

  • Park, Woon-Yong;Park, Cheol-Ung;Hong, Yun-Gi;Choi, Sung-Soo;Lee, Won-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.4A
    • /
    • pp.352-360
    • /
    • 2008
  • Recently Task Group (TG) 4 of the Institute of Electrical and Electronics Engineers (IEEE) 802.15a has been recommended a system with ranging capability in existence of multiple Simultaneous operating piconets (SOPs) as well as low-cost, low-power. According to the ranging service, coherent and non-coherent based ranging schemes using ternary code have been adopted as a standard. However it is hard to estimate an accurate time of arrival (TOA) in case of using direct sequence based TOA estimation method because pulse repetition interval (PRI) offered by TG is more limited than the maximum excess delay (MED) of channel. To mitigate inter pulse interference (IPI) problem, this paper proposes a non-coherent TOA estimation scheme using non-periodic transmission (NPT) pattern. The proposed receiver is based on a non-coherent energy detection considering with motivation of low rate wireless personal area network (LR-WPAN). TOA information is estimated via proper comparison with a prescribed threshold after the sliding correlation and search back window (SBW) process for reducing TOA error. To verify the performance of proposed ranging scheme, two distinct channel models approved by IEEE 802.15.4a TG are considered. According to the simulation results, we could conclude that the proposed scheme have performed better performance than the conventional method on the existence of multiple SOPs.

Silver nanowires and nanodendrites synthesized by plasma discharge in solution for the catalytic oxygen reduction in alkaline media

  • Kim, Hoe-Geun;Song, Myeon-Gyu;Kim, Dong-U;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.62-62
    • /
    • 2018
  • Pt is still considered as one of the most active electrocatalysts for ORR in alkaline fuel cells. However, the high cost and scarcity of Pt hamper the widespread commercialization of fuel cells. As a strong candidate for the replacement of Pt catalyst, silver (Ag) has been extensively studied due to its high activity, abundance, and low cost. Ag is more stable than Pt in the pH range of 8~14 as the equilibrium potential of Ag/Ag+ being ${\approx}200mV$ higher than that of Pt/PtO. However, Ag is the overall catalytic activity of Ag for oxygen reduction reaction(ORR) is still not comparable to Pt catalyst since the surface Ag atoms are approximately 10 times less active than Pt atoms. Therefore, further enhancement in the ORR activity of Ag catalysts is necessary to be competitive with current cutting-edge Pt-based catalysts. We demonstrate the architectural design of Ag catalysts, synthesized using plasma discharge in liquid phase, for enhanced ORR kinetics in alkaline media. An attractive feature of this work is that the plasma status controlled via electric-field could form the Ag nanowires or dendrites without any chemical agents. The plasma reactor was made of a Teflon vessel with an inner diameter of 80 mm and a height of 80 mm, where a pair of tungsten(W) electrodes with a diameter of 2 mm was placed horizontally. The stock solutions were made by dissolving the 5-mM AgNO3 in DI water. For the synthesis of Agnanowires, the electricfield of 3.6kVcm-1 in a 200-ml AgNO3 aqueous solution was applied across the electrodes using a bipolar pulsed power supply(Kurita, Seisakusyo Co. Ltd). The repetition rate and pulse width were fixed at 30kHz and 2.0 us, respectively. The plasma discharge was carried out for a fixed reaction time of 60 min. In case of Ag nanodendrites, the electric field of 32kVcm-1 in a 200-ml AgNO3 aqueous solution was applied and other conditions were identical to the plasma discharge in water in terms of electrode configuration, repetition rate and discharge time. Using SEM and STEM, morphology of Ag nanowires and dendrites were investigated. With 3.6 kV/cm, Ag nanowire was obtained, while Ag dendrite was constructed with 32 kV/cm. The average diameter and legth of Ag nanowireses were 50 nm and 3.5 um, and thoes values of Ag dendrites were 40 nm and 3.0 um. As a results of XPS analysis, the surface defects in the Ag nanowires facilitated O2 incorporation into the surface region via the interaction between the oxygen and the electron cloud of the adjacent Ag atoms. The catalytic activity of Ag for oxygen reduction reaction(ORR) showed that the catalytic ORR activity of Ag nanowires are much better than Ag nanodendrites, and electron transfer number of Ag nanowires is similar to that of Pt (${\approx}4$).

  • PDF

Ablation Rate and Intrapulpal Temperature by Addition of Water Spray During Er:YAG Laser Irradiation (Er:YAG laser를 이용한 치아삭제시 물분사량이 삭제율과 치수내 온도변화에 미치는 영향)

  • Kim, Jung-Moon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.375-381
    • /
    • 2005
  • Er:YAG laser has been considered a promising alternative to dental drill and many researches indicate that adjustment to variable parameters, including water flow rate, pulse energy and pulse repetition rate, can be made to improve ablation ability and efficiency of the laser. Of these parameters, addition of water spray during irradiation has been thought to ablate dental hard tissue more rapidly and safely. The purpose of this study was to investigate tooth ablation amount by Er:YAG laser irradiation as related to varied water flow rates added and, ultimately to find the most effective water flow rate for ablation. In addition, the temperature change of pulp chamber during irradiation was also monitored on the irradiated and opposite pulpal walls, respectively. An Er:YAG laser with contact mode was employed. Extracted human molars were split into two pieces for ablation experiment. Pulse energies of 200 and 300 mJ with a pulse repetition rate of 20 Hz and 5 water flow rates (1.6, 3.0, 5.0, 7.0, and 10.0 ml/min) were applied. Each irradiation was performed for 3 seconds. According to these parameters, experimental groups were divided into 10 subgroups which consisted of 5 specimens. For temperature experiment, another 5 tooth-specimens were prepared in the manner that pulp chamber was open through access cavity preparation and two temperature-measuring probes were placed respectively on the irradiated and the opposite walls of pulp chamber. From the experiment on ablation amount related to different water flow rates, it was shown that the least water flow rate of 1.6 ml/min ablated more than any other water flow rates (p<0.000). When the irradiation for 3 seconds, combined with the pulse repetition time of 20Hz and the water flow rate of 1.6 ml/min was done to tooth specimen, the temperature rise was not noticeable both on the irradiated and the opposite pulpal walls (less than 3$^{\circ}C$) and there was no significant difference in temperature rise between the two pulse energies, 200 and 300 mJ. From the results of this study, it is suggested that tooth ablation with Er:YAG laser can be done effectively and safely at a energy between 200 and 300 mJ/pulse and a pulse repetition rate of 20 Hz when the lasing is conjugated with the water flow rate of 1.6ml/min.

QUANTITATIVE MONITORING OF TISSUE OXYGENATION BY TIME-RESOLVED SPECTROSCOPY

  • Yamashita, Yutaka;Oda, Motoki;Ohmae, Etsuko;Tsuchiya, Yutaka
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2101-2101
    • /
    • 2001
  • Near-infrared spectroscopy is now being used in clinical diagnosis as a non-invasive monitor of tissue oxygenation state. However, due to lack of the optical pathlength information within tissues, it is still difficult to quantitate the hemoglobin concentration with present CW techniques. Time-resolved spectroscopy (TRS), which measures temporal profiles of emerging light from tissues, enables to estimate the pathlength distribution within tissues by converting time to distance. Consequently, quantitative measurement of tissue oxygenation is possible by analyzing the data with optical diffusion equation 1) or our Microscopic Beer-Lambert law2). Time-Resolved Spectroscopy System : TRS-1O3) Our TRS-10 system consists of a three-wavelength (759, 797, 833 nm) PLP as pulsed light source, a high speed PMT with high sensitivity and three signal-processing circuits for time-resolved measurement (CFD/TAC, A/D converter and histogram memory). Optical pulse train consisting of 759, 797 and 833nm is generated by PLP at 5㎒ repetition rate and irradiated a sample through a single optical fiber. The diffuse-reflected light from the sample is collected by a bundle fiber and then detected by the PMT for single photon measurement. After being amplified by a following fast amplifier, the electrical signals for each wavelength are picked out by CFD/TAC module. Then, a signal processing circuit integrated the TRS data for each wavelength individually. The simultaneous TRS measurement for three wavelengths achieved without any optical or mechanical switch. Experiment and Results Input and detection fibers of TRS-10 were attached at the human forehead with a fiber separation of 3cm. TRS measurements were continuously performed for about 20 minutes including 2 minutes hyper ventilation. It was observed that the total hemoglobin concentration was decreasing during the hyper ventilation and recovered until 2 minutes after hyper ventilation. On the other hand, the deoxy-hemoglobin concentration began to increase after hyper ventilation and had its peak at around 2 minute later, showing 502 drop from 75% to 60% due to inhibition of breathing by performing hyper ventilation. The results showed that this system might be able to quantitate the concentrations of oxy- and deoxy-hemoglobin in the human brain.

  • PDF

Exposure assessment of musculoskeletal disorder risk factors in non routinized work: An application of PATH-KOSHA observational tool to hospital workers (비정형작업 근골격계질환 위험요인의 노출평가: 일부 병원근로자에 대한 PATH-KOSHA 관찰도구 적용사례)

  • Park, Jung-Keun;Han, Young-Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.4
    • /
    • pp.412-422
    • /
    • 2009
  • This study was conducted to assess exposure to musculoskeletal disorder(MSD) risk factors in hospital personnel who performed non-routinized work tasks. A tool ("PATH-KOSHA" version) was newly revised from PATH(Posture, Activity, Tools and Handling) method and uploaded into a personal digital assistant(PDA). The version was used, on a basis of direct-observation, to collect PATH data at the 2 hospital settings in different regions. Job analysis was performed to get various information (e.g., work and rest time, task type) as well. The data collected were visually checked for data cleaning and stored for future data analysis. A total of 1,992 PATH observations were made for 37 hospital workers. Exposure levels varied across 18 items of the MSD risk factors. The highest percent time spent on non-neutral postures was 53% for wrist deviation, followed by 47%(pinch grip), 35%(trunk posture), 23%(neck posture), and 20%(shoulder/arm posture). The highest percent time spent among hand activity level(HAL) variables was 55% for HAL-cat2 (HAL: 3.3 - <6.7). The percent time of items with respect to both loads with more than 5kg and contact stress was less than 4%. Vibration was not exposed in the study workers. Different aspects were discussed for findings. The study results showed that wrist deviation was highest in percent time spent on awkward posture while HAL-cat2 was highest in hand repetition. The study suggests that distal upper extremity posture and HAL should be primarily addressed and controlled in non-routinized work including the hospital settings.

[ $T_2$ ]-relaxation Time Measurement of ex vivo $^1H$ MR Metabolite Peaks for Evaluation of Human Stomach Cancer

  • Mun Chi-Woong;Choi Ki-Sueng;Shin Oon-Jae;Yang Young-Ill;Chang Hee-Kyung;Hu Xiaoping;Eun Chung-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.2
    • /
    • pp.53-58
    • /
    • 2006
  • In this study, transverse relaxation time (T2) measurement and the evaluation of the characteristics of the spectral peak related to stomach tissue metabolites were performed using ex vivo proton magnetic resonance spectroscopic imaging (MRSI) at 1.5-T MRI/S instruments. Thirty-two gastric tissues resected from 12 patients during gastric cancer surgery, of which 19 were normal tissue and 13 were cancerous tissue, were used to measure the $T_2$ of the magnetic resonance spectroscopy (MRS) peaks. The volume of interest data results from the MRSI measurements were extracted from the proper muscle (MUS) layer and the composite mucosa/submucosa (MC/SMC) layer and were statistically analyzed. MR spectra were acquired using the chemical shift imaging (CSI) point resolved spectroscopy (CSI-PRESS) technique with the parameters of pulse repetition time (TR) and echo times (TE) TR/(TE1,TE2)=1500 msec/(35 msec, 144 msec), matrix $size=24{\times}24$, NA=1, and voxel $size=2.2{\times}2.2{\times}4mm^3$. In conclusion, the measured $T_2$ of the metabolite peaks, such as choline (3.21ppm) and lipid (1.33ppm), were significantly decreased (p<0.01 and p<0.05, respectively) in the cancerous stomach tissue.

Efficient Implementation of FMCW Radar Signal Processing Parts Using Low Cost DSP (저가형 DSP를 사용하는 FMCW 레이더 신호처리부의 효율적 구현 방안)

  • Oh, Woojin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.707-714
    • /
    • 2016
  • Active driving safety systems for vehicle, such as the front collision avoidance, lane departure warning, and lane change assistance, have been popular to be adopted to the compact car. For improving performance and competitive cost, FMCW radar has been researched to adopt a phased array or a multi-beam antenna, and to integrate the front and the side radar. In this paper we propose several efficient methods to implement the signal processing module of FMCW radar system using low cost DSP. The pulse width modulation (PWM) based analog conversion, the approximation of time-eating functions, and the adoption of vector-based computation, etc, are proposed and implemented. The implemented signal processing board shows the real-time performance of 1.4ms pulse repetition interval (PRI) with 1024pt-FFT. In real road we verify the radar performance under real-time constraints of 10Hz update time.

A New Design of Power Folding Controller for Deterioration Detection (열화방지형 파워폴딩 제어기 설계에 관한 연구)

  • Kim, Ji-Hyeon;Lee, Dong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.51-58
    • /
    • 2008
  • This paper is a study of a prevention of power folding controller's thermal degradation. Power folding technology has been applied for many fields such as side rear vision mirror of vehicles, windshield wiper, antenna, power window. These controllers have been comprised with traditional DC moors, Switching electronic devices, and relays. But this methods have a limitation to overcome such problems of product reliability, endurance, noise margins. Therefore on this paper, to detect the movement of motor, sensing motor brush noise on a load sensing part has been used and controlling a precise RC timing control minimizes the thermal deterioration of motor. And using MOS FETs as a electronic switching device increases life-time and liability of control circuit. After testing such circuit and control method, repetition of operating time, cut-off time, wide operation voltage, power noise margin ware increased over eleven-fold.

Analysis of Motor Performance and P300 during Serial Task Performance according to the Type of Cue (시열과제 수행 시 신호형태에 따른 운동수행력과 P300 분석)

  • Lee, Myoung-Hee;Kim, Myung-Chul;Park, Ju-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.281-287
    • /
    • 2013
  • PURPOSE: The study was designed to investigate the effects of visual, auditory, and visuoauditory cues on simple Serial Task Performance in heaithy adults. METHODS: Sixty-three right-handed heaithy adults without history of neurological dysfunction were participated. A modified version of the Serial Reaction Time Task (SRTT) using five blocks of perceptual motor sequences was administered. The blocked paradigm consisted of the five blocks with randomly repeated 8 digit sequences with 5 repetition. Three types of sensory cue were employed: visual cue, auditory cue and visuoauditory cue. All subjects were assigned to press the matched botton as quickly and accurately as possible, when one of 8 stimulations was presented(one, two, three, four, five, six, seven, eight). The reaction time, accuracy, and P300 latency were measured during serial task performance. The mean reaction time(ms), accuracy(%), and P300 latency(ms) were compared between three types of cue using ANOVA. RESULTS: The reaction time to auditory cue was significantly longer than visual and visuoauditory cues(p<.001). And accuracy to auditory cue was significantly lower than visual and visuoauditory cues(p<.001). All P300 latency(at Fz, Cz, Pz) were significantly longer than to visual and visuoauditory cues(p<.05). CONCLUSION: It is suggested that type of cues influence in choice reaction. These data may helpful in designing not only effective motor learning training programs for healthy persons but also reeducation programs for patients with neurological dysfunction.

A Study on the Effect of the Changes of Dyeing Conditions on the Dyeability of Cotton Fabrics dyed with Natural Polygoum tinctoria (면직물의 쪽 천연염색에서 염색조건의 변화가 염색성에 미치는 영향)

  • Kim, Mik-Young;Jeon, Dong-Won
    • Journal of Fashion Business
    • /
    • v.15 no.4
    • /
    • pp.144-154
    • /
    • 2011
  • Polygoum tinctoria dye is the one using the method of reducing dyeing, and so is made by the mechanism different from natural dye in general, and the reproductive dye is more difficult because it varies in accordance with manufacturing method and days being manufactured in case of natural indigo dye that has been used traditionally. In addition, overall analysis is short of color changes in accordance with natural dyeing condition and barely none of the research for cellulose system such as cotton in particular. Accordingly, this study tries to research on the natural dyeing method optimal for color development that is desirable in designing and development of natural dyeing as comparing and contemplating the change of dyeing quality and color in accordance with reduction temperature and time, reductant quantity, dyeing temperature and time, NaOH quantity, and dyeing repetition times in order to expand dyeing methods and use variously polygoum tinctoria by improving traditional dyeing methods as well as to establish exact dyeing method of cotton which is a fabric of cellulose system in order to make such polygoum tinctoria quantificated and reproductive. The optimum conditions in the dyeing procedure are as follows: Reducing temperature is $50^{\circ}C$. Added concentration of the reducing agent is $3g/{\ell}$. Reducing time is 30minutes. Dyeing temperature is $30^{\circ}C$. Added concentration of NaOH is $1g/{\ell}$. Dyeing time is 30minutes.