임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구 (A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY)

  • 양재식;방몽숙;조규종
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.83-93
    • /
    • 2004
  • Statement of problem : Since the concept of osseointegrated dental implant by $Br{\aa}nemark$ et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate (p < 0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p < 0.05). 3. Cone screw groups have the highest initial stability and anal stability. 4. All groups are decreased tightening rate after repeated loading.

치과 임플랜트 지대나사의 풀림 현상에 관한 연구 (A STUDY ON THE ABUTMENT SCREW LOOSENINE OF DENTAL IMPLANTS)

  • 강윤모;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.1-14
    • /
    • 1996
  • Abutment screw loosening of dental implant is a major problem in the treatment of dental implant. The purpose of this study was to examine the effect on the prevention of screw loosening according to tightening method and using of washer. In the first experiment, using a implant fixture and precisely fabricated temporary cylinder, the loosening torque was measured by tightening the screw 5 times repeatedly. In the second experiment, the fabricated crown and implant fixture was tightened by the screw that is attatched washer and then the loosening torque was measured after loading it 1800, 12600 times under the force of 150N. The results were as follows. 1. The highest loosening torque appeared after tightening 3 times repeatedly(p<0.01). 2. When the washer was used, the loosening torque was increased significantly under the loading 1800 times(p<0.01), 3. When the washer was used, the loosening torque was increaed under the loading 12600 times, but it is statistically not significant(p<0.01). The first experiment results mean that 3 times repeated tightening screw is most effective clinically. The second results mean that washer is effective in prevention screw loosening, but the effect is decreased with increasing load.

  • PDF

치과용 임플랜트에서 지대주 나사의 길이 및 반복 조임 횟수가 지대주 나사의 풀림에 미치는 영향 (THE INFLUENCE OF ABUTMENT SCREW LENGTH AND REPEATED TIGHTENING ON SCREW LOOSENING IN DENIAL IMPLANT)

  • 최진호;양재호;조원표;이재봉
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.432-442
    • /
    • 2006
  • Statement of problem: One of common problems associated with dental implant is the loosening of abutment screws that retain the implants. Purpose : This study was performed to investigate the influence of abutment screw length and repeated tightening on screw loosening in dental implant. Material and method: Forty nine Hexplants (13mm length, 4.3mm diameter, Ti grade IV, Warantec. Co. Ltd. Seongnam, Korea) and cementation type abutments(straight abutment) and abutment screws (0.4mm/pitch) were divided into 7 groups, depending on abutment screw length. Each implant and abutment was tightened to 30Ncm by torque controller(MGT50, MARK-10 Inc., USA) and the removal torque values were measured during 10 consecutive closure/opening trials. Results and Conclusion: The results of comparing the removal torque value are as follows : 1. There is no significant difference in the removal torque value between groups in 10 consecutive closure/opening trials (p = 0.97). 2. If the fractured abutment screw is engaged in longer than 2.425 thread length, there is no significant difference in the preload between the fractured abutment screw and the new abutment screw when both are equally tightened to 30 Ncm. 3. The removal torque value in the 1st trial(24.510 Ncm) was lower than that in the 2nd, 3rd, 4th, 5th, 6th, 7th trials and the removal torque value in the 2nd trials(25.551 Ncm) was maximum and was decreased in 1311owing trials. The removal torque value in the 1st trial was significantly lower than that in the 2nd, 3rd, 4th trials and was significantly higher than that in the 8th, 9th, l0th trials(p<0.05). 4. In the 2nd, 3rd, 4th, 5th, 6th, 7th trials, the abutment screw was mainly influenced by settling effect and the higher preload was obtained In the 8th, 9th, l0th trials, the abutment screw was mainly influenced by adhesive wear and the progressively lower preload was obtained.

임플란트 시스템에서 반복풀림조임 후 전기화학적 침식이 파절거동에 미치는 영향 (Effects of Electrochemical Attack on the Fracture Behavior after Repeated Loosening/Tightening of Implant System)

  • 박찬익;정재헌;정용훈;최한철
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2008년도 추계학술대회 초록집
    • /
    • pp.133-133
    • /
    • 2008
  • 본 연구에서는 임상적으로 사용후 임플란트시스템의 안정성을 조사하기 위하여 인위적으로 풀림 조임을 1회와 20회로 반복한 후 0.9% NaCl에서 부식을 시키고 파괴한 후 임플란트시스템의 안정성에 대하여 조사하였다.

  • PDF

A useful method of using the healing abutments for interocclusal records in implant overdenture: a case report

  • Choi, Hyunsuk;Kang, Sohee
    • Journal of Yeungnam Medical Science
    • /
    • 제39권4호
    • /
    • pp.341-343
    • /
    • 2022
  • To determine the vertical dimension and centric relation during the construction of implant overdentures, the record base and wax rim may need to be adjusted. The conventional method has several drawbacks, as it requires repeated tightening and loosening of the impression coping. Here, we report a useful and novel method for interocclusal records using the healing abutments in implant overdentures. Our case demonstrates that this method is easier and simpler and prevents gingival collapse.

임플란트 토크 조절기의 비교 분석 연구 (Comparative Analysis of the Implant Torque Controllers)

  • 김대곤;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.27-36
    • /
    • 2012
  • 임플란트를 이용한 치료가 대중화됨에 따라 다양한 문제가 보고되고 있는데, 이 중에서도 나사풀림현상과 관련된 토크 조절기의 사용에 있어 제조회사에서 권장하는 적절한 토크값과 실제 적용되는 조임력에는 차이가 있음이 여러 연구결과를 통해 보고되고 있다. 본 연구에서는 제품마다 사용기간이 다른 토크 조절기를 이용하여 각각에 따른 정확도를 비교, 분석하고자 하였다. 오차율은 제조회사별로 차이가 있었지만 모든 제품에서 사용기간이 증가할수록 기준값에 대한 오차율은 증가하였다. 그리고 반복 조임 횟수 증가에 따른 측정값의 변화를 살펴보면 반복 조임 초기에는 기준값에 근접한 값을 나타내었지만 기준값에 대한 변화의 폭은 크게 나타났고, 반복 조임 횟수가 증가할수록 기준값에 대한 오차율은 증가하였지만 변화의 폭은 줄어드는 것으로 관찰되었다.

회전 방지용 Post Screw 시스템의 임플랜트 지대나사풀림 방지효과에 관한 연구 (A STUDY OF THE ANTI-ROTATING INNER POST SCREW SYSTEM AS A MEANS OF PREVENTING ABUTMENT SCREW LOOSENING)

  • 김종희;임주환;조인호;이준석
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.671-683
    • /
    • 2005
  • Statement of problem: The most commonly reported problem associated with dental implant restoration is the loosening of the screws. Purpose: This study compared the efficacy of an implant system incorporating an anti-rotational locking sleeve(Anti-Rotating Inner Post Screw System(ARIPS-system)) with other, traditional implant systems as a means of minimizing vibration loosening. Materials and methods: Three implant systems were examined; the conventional external hex type, the ARIPS-system, and the internal taper type implant system 30 specimens(10 samples per group)were fabricated and each abutment screw was secured to the implant future with 32Ncm of torque force and loosening torque was measured using a Torque Gauge. The procedure was repeated 3 times, recording initial loosening torque each time. The re-tightened abutment screw was subjected to a cyclic load having a maximum forte of 200N and minimum of 20N at 2Hz over a period of 12,600 cycles. after which the loosening torque was measured. Measured values were calaulated for statistical analysis. Analysis of measured value was performed by 3 methods: (i) as a percentage average of the initial 3 loosening-torque values(initial loosening value) to the tightening torque of 32Ncm, (ii) as a percentage of the loosening torque value after a load of 200N(experimental value) to the initial loosening value, and (iii) as a percentage of the experimental value to the 32Ncm of tightening torque. The analyses shows the amount of initial loosening at the screw, loosening by repetitive load and the the final loosening value. Results: The results of this study were as follows (1) Percentage of initial loosening value to tightening-torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of external hex, ARIPS-system and internal taper. Value of internal taper showed significant difference with those of external hex and ARIPS-system (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). Conclusion: The results of the analysis of the final loosening level value, which are closely correlated to clinical use, show that the ARIPS-system can be a useful means of minimizing abutment screw loosening when compared to the external hex type system. Although further clinical studies need to be made, the ARIPS-system should be considered to maximize the long-term success of the implant prosthesis.

기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교 (Comparison of removal torque between prefabricated and customized abutment screw)

  • ;김지환;김무성;박영범;심준성
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.243-248
    • /
    • 2012
  • 연구 목적: 본 연구의 목적은 임플란트 지대주 연결에 사용되는 기성품 나사와 맞춤형 나사의 풀림 토크를 비교하는 것이다. 연구 재료 및 방법: 세가지 임플란트 시스템에(Osstem, Astra, Zimmer) 대해 고정체와 지대주의 연결에 기성품 나사군(대조군)과 맞춤형 나사군(실험군)으로 총 6군(n = 6)으로 나누었다. 조임 토크조절은 디지털 토크 측정기를 이용하였으며 각 임플란트 제조사가 추천한 조임 토크 값을 적용하였다. 체결 10분 후 동일한 조임 토크를 다시 적용하고 5분 후에 풀림 토크력을 측정하였다. 이 과정을 10회 반복 측정하였다. 반복 하중 실험에서는 6개 군(n = 3)에 대해 체결 10분 후 2차 조임 토크를 적용하고 $30^{\circ}$ 경사로 50 N 하중으로 총 1,000,000번 반복 하중을 가하였다. 반복 하중 적용 이후 풀림 토크값을 측정하였다. 통계 방법으로는 10회 반복 측정에서 풀림 토크값의 차이를 비교하기 위해 repeated measures of ANOVA test (${\alpha}$=.05)를 사용하였고, 반복 하중 후 풀림 토크값의 차이를 비교하기 위해서 각 시스템별 Independant t-test로 통계 처리하였다. 결과: 모든 군에서 반복 횟수가 증가할수록 풀림 토크값이 유의성 있게 감소하는 것으로 나타났다(P<.05). 10회 반복 측정 실험에서는 세 종류의 임플란트에서 대조군(기성품나사)과 실험군(맞춤형 나사) 간에 풀림 토크값은 유의차가 없었다(P>.05). 반복 하중 실험에서 세가지 시스템에서 대조군과 실험군 간의 풀림 토크력은 유의한 차이가 없었다(P>.05). 결론: 반복 측정된 풀림력 검사와 반복 하중을 적용 후 풀림력 검사에서 맞춤형 나사와 기성품 나사의 풀림력은 유의한 차이가 없었다.

볼트 결합부 풀림에 관한 마찰 특성 (제 I 보 : 나사 마찰 실험) (The Friction Properties on the Loosening of Bolted Joints (I: Thread Friction Experiments))

  • 박태원;신귀수
    • 한국안전학회지
    • /
    • 제18권2호
    • /
    • pp.1-5
    • /
    • 2003
  • By using an approach developed to determine the torque-tension relationship for bolted joints, frictional properties of several typical bolted joints were studied experimentally. The specific property by bolted joints certify that the most significant influence of materials and bearing surface condition. Experiments on thread friction shows that prevailing torque nuts with distorted threads provide benefit for preventing self-loosening of the nut. Repeated tightening-loosening generally increases frictions in a bolted joint. It was noted that the data scatter of the experimental results of frictions in a belted joint may overshadow the influence of size. speed, and contact positions. The results from the experimental investigation will help to better design bolted joints.

Accuracy of different electronic torque drivers: A comparative evaluation

  • Ko, Byeong-Dae;Son, KeunBaDa;Kang, Seok Hyon;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.350-357
    • /
    • 2019
  • PURPOSE. This study aims to evaluate the loosening torque on the implant fixture, and to assess the accuracy of difference electronic torque drivers. MATERIALS AND METHODS. Three electronic torque drivers were used to measure the loosening torque on the implant system (AnyOne; MegaGen). The implant fixtures were divided among the 3 electronic torque driver types (W&H, SAESHIN, and NSK group) and 9 for each group. The screws were fastened at the implant fixture by three electronic torque drivers using the tightening torques recommended by the manufacturers of the drivers. After 10 minutes, the screws were again fastened at the implant fixture with equal torque. Then, the loosening torques were measured with an MGT12 torque gauge (MARK-10, Inc.). This measurement procedure was repeated 10 times under loosening torques of 15 Ncm, 25 Ncm, and 35 Ncm. In the statistical analysis, all values of loosening torque were analyzed with the one-way ANOVA and Kruskal-Wallis test (α=.05) for comparative evaluation. RESULTS. There were significant inter-group differences at loosening torques of 15 Ncm and 25 Ncm (P<.05). The accuracy of the NSK driver was the highest, followed by SAESHIN and W&H. There was no significant difference between NSK and W&H at 35 Ncm (P>.05). The SAESHIN driver showed the closest loosening torque at 35 Ncm. CONCLUSION. The most accurate loosening torques were SAESHIN at 35 Ncm, and NSK at 15 Ncm and 25 Ncm. Since the loosening torque may vary depending on the tightening torques and electronic torque drivers, periodic calibration of the electronic torque driver is recommended.