• Title/Summary/Keyword: Repeated measure

Search Result 694, Processing Time 0.021 seconds

Analysis of Skin Color Pigments from Camera RGB Signal Using Skin Pigment Absorption Spectrum (피부색소 흡수 스펙트럼을 이용한 카메라 RGB 신호의 피부색 성분 분석)

  • Kim, Jeong Yeop
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 2022
  • In this paper, a method to directly calculate the major elements of skin color such as melanin and hemoglobin from the RGB signal of the camera is proposed. The main elements of skin color typically measure spectral reflectance using specific equipment, and reconfigure the values at some wavelengths of the measured light. The values calculated by this method include such things as melanin index and erythema index, and require special equipment such as a spectral reflectance measuring device or a multi-spectral camera. It is difficult to find a direct calculation method for such component elements from a general digital camera, and a method of indirectly calculating the concentration of melanin and hemoglobin using independent component analysis has been proposed. This method targets a region of a certain RGB image, extracts characteristic vectors of melanin and hemoglobin, and calculates the concentration in a manner similar to that of Principal Component Analysis. The disadvantage of this method is that it is difficult to directly calculate the pixel unit because a group of pixels in a certain area is used as an input, and since the extracted feature vector is implemented by an optimization method, it tends to be calculated with a different value each time it is executed. The final calculation is determined in the form of an image representing the components of melanin and hemoglobin by converting it back to the RGB coordinate system without using the feature vector itself. In order to improve the disadvantages of this method, the proposed method is to calculate the component values of melanin and hemoglobin in a feature space rather than an RGB coordinate system using a feature vector, and calculate the spectral reflectance corresponding to the skin color using a general digital camera. Methods and methods of calculating detailed components constituting skin pigments such as melanin, oxidized hemoglobin, deoxidized hemoglobin, and carotenoid using spectral reflectance. The proposed method does not require special equipment such as a spectral reflectance measuring device or a multi-spectral camera, and unlike the existing method, direct calculation of the pixel unit is possible, and the same characteristics can be obtained even in repeated execution. The standard diviation of density for melanin and hemoglobin of proposed method was 15% compared to conventional and therefore gives 6 times stable.

Influence of Erythropoiesis Factors, BDNF, Cognitive Function and Working Memory by Intensity Aerobic Exercise in Middle Aged Women (강도별 유산소운동이 중년여성의 적혈구생성인자, BDNF와 인지기능, 작업기억에 미치는 영향)

  • Cho, Won-Je
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.1
    • /
    • pp.553-566
    • /
    • 2015
  • This study was performed to identify the effects of different intensities of regular aerobic exercise on erythropoietin (EPO) and BDNF levels, and cognitive function and working memory in middle-aged women. Women aged 40 to 60 years residing in G-gu, Y-si, Gyeonggi-do were divided into 3 groups: control group, moderate-intensity aerobic exercise group and high-intensity aerobic exercise. All groups were asked to exercise at the given intensities, twice a week for a total of 12 weeks. Blood samples were collected from participants on week 0 (before exercising), week 6 and week 12, and then cognitive function and working memory tests were followed to measure erythropoietin (EPO) and BDNF levels, cognitive function and working memory. Repeated measures ANOVA, univariate analysis and follow-up test were performed on all data to compare the group, period and interaction through a SPSS. As a result, a significant difference over time was observed in EPO, BDNF, cognitive function and working memory; therefore, a follow-up one-way ANOVA analysis was performed on each group. As a result of analysis, a significant increase in erythrocyte, hematocrit, BDNF level and working memory was observed in moderate-intensity aerobic exercise group while erythrocyte and working memory were significantly increased inhigh-intensity aerobic exercise group. When comparing the results between the groups, the level of hematocrit was shown to be significantly higher in both moderate-and high-intensity aerobic group than the control group and also the higher level of hemoglobin was observed in both moderate-and high-intensity aerobic group comparing to control group. Considering the results of this study, therefore, a 12-week long aerobic exercise at moderate to high intensity positively affected EPO and BDNF levels, cognitive function and working memory in middle-aged women.

Autonomic Nervous Response of Female College Students with Type D Personality during an Acute Stress Task: Heart Rate Variability (Type D 성격 여대생의 급성 스트레스에 따른 자율신경계 반응 : 심박률 변동성을 중심으로)

  • Ko, Seon-Young;Kim, Myung-Sun
    • Korean Journal of Health Psychology
    • /
    • v.14 no.2
    • /
    • pp.277-292
    • /
    • 2009
  • This study investigated the responses of the autonomic nervous system of individuals with Type D personality during an acute stressful situation. Twenty-three female students of Type D personality and 23 female students with non-Type D personality. Stroop Color-Word Task was used to induce a stressful situation, heart rate variability (HRV) was used to measure the responses of the autonomic nervous system during the baseline, acute stress, recovery periods. To analyze the data, the repeated measures analysis of variance was used to compare the autonomic nervous system of the Type D group to that of the non-Type D group. Regression analysis is used to determine if the Type D scale and stress vulnerability predicted the activities of the autonomic nervous system during the baseline period. The results of this study demonstrated that the Type D group's normalized low frequency (LF norm) and ratio of low frequency to high frequency (LF/HF ratio) were higher than those for the non-Type D group, while its normalized high frequency (HF norm) was lower than that for the non-Type D group in all three periods. There were no statistically significant differences among the three periods in terms of LF norm, HF norm, and LF/HF ratio in the Type D group. The study demonstrated that the total scores of the Type DS-14 and scores of social inhibition and negative affect were independent predictors of LF norm and HF norm during the baseline. The Type D group showed increased activation of the sympathetic nervous system and/or decreased activation of the parasympathetic nervous system. These results support the hypothesis that the Type D personality is vulnerable to the stress. Also, the highly activated sympathetic and/or lowly activated parasympathetic nervous systems, which were observed in the Type D group during the baseline, indicated that the Type D individual is susceptible to psychosomatic disorders.

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.