• 제목/요약/키워드: Renewable energy in grid-connected

Search Result 133, Processing Time 0.035 seconds

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

태양광 발전과 ESS 시스템의 연계운전시 단독운전 방지 사례 연구 (A Case Study on the Islanding Detection Protection of PV System and ESS System)

  • 임종록;황혜미;신우균;주영철;정영석;강기환;고석환
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.59-66
    • /
    • 2019
  • BIPV or BAPV installation applied to building is increasing through public utility mandates enterprise. Solar PV energy generates only during the day, but if it is operated in convergence with ESS, which stores electrical energy, it can restrain the fossil energy used in buildings throughout the day. A solution is to converge with PV system and ESS. However, PV systems and ESS connected to the power grid in parallel can cause problems of electrical stability. A study was conducted on the case of failure to detect islanding operation under the parallel operation of PV generation and ESS that are connected in parallel to power grid. Experiments conducted various non-islanding detections under the operating conditions. In the experiment results, when one PCS - PV inverter or ESS inverter - was operating under the islanding condition, it stopped working within 0.5 seconds of the Korean grid standard. However, when both of PV inverter and ESS inverter were operating at the same time under the islanding situation, the anti-islanding algorithm did not operate normally and both inverters continuously supplied power to the connected RLC loads. islanding detection Algorithm developed by each inverter manufacturer has caused this phenomenon. Therefore, this paper presented a new test standard for islanding detection.

Grid Parity를 고려한 DC 전원 공급율에 따른 신재생에너지 계통 연계의 경제성 평가 (The Economic Evaluation of Renewable Energy Penetration Based on Grid Parity According to the Ratio of DC Power Supply)

  • 김성열;이성훈;김진오
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.16-21
    • /
    • 2012
  • The growth in IT industry has brought a corresponding rise in the number of connected digital devices in the distribution network. These digital loads lead to AC to DC conversion losses in order to supply power to them. The more the renewable energies and plug-in electrical vehicles penetrated our lives, the more the electrical losses are caused by AC to DC conversion process. Hence, this paper suggests the methodology for evaluating the amount of power supplied according to the ratio of DC power supply and performs an economic analysis of DC distribution system considering grid parity. In here, the cost of carbon emission reduced by renewable energy is also concerned.

A Study of Grid-Connected PV System with Power Control Structure

  • Vu, Trung-Kien;Bae, Youngsang;Oh, Seongjin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.329-330
    • /
    • 2012
  • The rising popularity of renewable energy sources resulted in development of the units of higher rated powers, where the large-scale plants and grid-connected type solar power systems are increased. Therefore, the importance of grid stabilization, which depends on each country or system-type, has been strengthened by different grid-codes or certifications. In this paper, the control scheme of three-phase photovoltaic system is enhanced, where both injected active and reactive powers are simultaneously controlled with the consideration of the certification of the Germany Association of Energy and Water Industries (BDEW). Experimental results are shown to verify the theoretical analysis.

  • PDF

Grid-Connected Three-Phase Inverter System with Sub Inverter using Combination Type UPFC Structure

  • Park, Seong-Mi;Vi, Le Thi Tuan;Jeong, Da-Woom;Park, Sung-Jun;Park, Jang-Sik
    • 한국산업융합학회 논문집
    • /
    • 제23권4_1호
    • /
    • pp.559-567
    • /
    • 2020
  • As the renewable energy market grows, grid-connected inverters have been improving and expanding in several fields in recent years because energy conversion devices are the main components of solar systems. In this paper, a high-precision new grid-connected three-phase inverter system is proposed. The proposed system consists of a main inverter, a sub inverter and a transformer. The main inverter operates at a low switching frequency and high power and transmits power to the grid. A sub-inverter connected in series with the transmission line through a matching transformer operates at lower power than the main inverter to provide input values to the transformer. The transformer acts as a power supply according to the voltage compensation value. This study is based on the principle of operation of the UPFC(Unified Power Flow Controller) structure used to regulate power flow in AC transmission lines. The grid-connected inverter system proposed in this paper is implemented with high precision and high resolution. The proposed system was verified through its ability to enhance and ensure the safety of the proposed system through simulation and experiment.

고조파와 무효전력 보상기능을 가지는 Smart PCS의 새로운 제어 알고리즘 (Novel control algorithm for smart PCS with harmonics and reactive power compensation)

  • 서효룡;장성재;박상수;김상용;김경훈;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1053_1054
    • /
    • 2009
  • A significant number of renewable energy systems have been connected to the grids as supplement power source. The renewable energy systems require control algorithm to maintain the power-supply reliability and quality. This paper proposes a novel control algorithm for smart Power Conditioning System (PCS) with harmonics and reactive power compensation. The smart PCS is used to feed Photovoltaic (PV) power to utility and compensate harmonics and reactive power at the same time. The experimentation is carried out on the proposed grid-connected PV generation system, and controlled by digital signal processor. The grid-connected PV generation system injects PV energy into the grid and performs as Active Filter (AF) and Static Synchronous Compensator (STATCOM) without additional devices. The experiment results show that the proposed control algorithm is effective for smart PCS with harmonics and reactive power compensation.

  • PDF

독일 계통 연계 규정에 기반 된 대용량 태양광 발전 시스템의 계통 안정화를 위한 제어 전략 (Control Strategy for a Grid Stabilization of a Large Scale PV Generation System based on German Grid Code)

  • 배영상;김래영
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.41-50
    • /
    • 2014
  • The rising penetration of renewable energy resulted in the development of grid-connected large-scale power plants. Therefore, grid stabilization, which depends on the system-type or grid of each country, plays an important role and has been strengthened by different grid codes. With this background, VDE-AR-N 4105 for photovoltaic (PV) systems connected to the low-voltage grid and the German Association of Energy and Water Industries (BDEW) introduced the medium-voltage grid code for connecting power plants to the grid and they are the most stringent certifications. In this paper, an optimal control strategy scheme for three-phase grid-connected PV system is enhanced with VDE-AR-N 4105 and BDEW grid code, where both active/reactive powers are controlled. Simulation and experimental results of 100kW PV inverter are shown to verify the effectiveness of the proposed implemental control strategy.

에너지 저장장치를 포함하는 신재생에너지원용 부스트 컨버터의 인덕터 기생저항에 따른 제어기 설계 영향 분석 (Influence of the Parasitic Inductor Resistance on Controller Design of Boost Converter for Renewable Energy System including an Energy Storage)

  • 박선재;박종후;전희종
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.511-520
    • /
    • 2011
  • 현재 스마트 그리드 산업으로 인하여 신재생에너지의 활용이 중시되고 있다. 이러한 시점에서 신재생에너지원을 더욱 효율적이고 안정적으로 사용하기 위해서 에너지 저장장치의 필요성이 부각되고 있다. 이러한 경우 신재생 에너지원을 계통에 사용할 수 있도록 만들어 주는 부스트 컨버터와 에너지 저장장치의 에너지 전달을 위한충 방전기를 사용하게 된다. 이 두 가지 전력변환장치의 사용을 위해, 상호 간섭에 의해 각각의 제어기 설계에 어떠한 영향을 미치는지 알아야 한다. 우선 각각의 제어기 설계를 위해 시뮬레이션을 통한 간접적인 결과를 얻어내야 하는데, 이 때 인덕터를 이상적으로 생각하고 시뮬레이션을 할 수도 있고, 실제 하드웨어와 같이 인덕터에 기생하는 저항을 포함하여 시뮬레이션 할 수도 있다. 본 논문에서는 부스트 컨버터의 인덕터 기생저항이 부스트 컨버터와 충 방전기의 제어기 설계시 어떠한 영향을 미치는 지에 대해 비교해 봄으로써 시뮬레이션시 인덕터 기생저항 성분을 반드시 고려하여 설계해야 한다는 것을 주파수 영역에서의 MATLAB 시뮬레이션과 시간영역에서의 PSIM 시뮬레이션을 통해 살펴보았다.

계통연계형 풍력, 태양광 및 축전지 하이브리드 시스템의 출력제어 및 동특성 해석 (Power Control and Dynamic Performance Analysis of a Grid-Interactive Wind/PV/BESS Hybrid System)

  • 김슬기;전진홍;조창희;안종보
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.317-324
    • /
    • 2007
  • Most conventional hybrid systems using renewable energy sources have been applied for stand-alone operation, but Utility-interface may be an useful and viable option for hybrid systems. Grid-connected operation may have benefits such as reduced losses in power system distribution, utility support in demand side management, and peak load shaving. This paper addresses power control and dynamic performance of a grid-connected PV/wind/BESS hybrid system. At all times the PV way and the wind turbine are individually controlled to generate the maximum energy from given weather conditions. The battery energy storage system (BESS) charges or discharges the battery depending on energy gap between grid invertger generation and production from the PV and wind system. The BESS should be also controlled without too frequently repeated shifts in operation mode, charging or discharging. The grid inverter regulates the generated power injection into the grid. Different control schemes of the grid inverter are presented for different operation modes, which include normal operation, power dispatching, and power smoothing. Simulation results demonstrate that the effectiveness of the proposed power control schemes for the grid-interactive hybrid system.

Modeling of Solar/Hydrogen/DEGS Hybrid System for Stand Alone Applications of a Large Store

  • Hong, Won-Pyo
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.57-68
    • /
    • 2013
  • The market for distributed power generation based on renewable energy is increasing, particularly for standalone mini-grid applications in developing countries with limited energy resources. Stand-alone power systems (SAPS) are of special interest combined with renewable energy design in areas not connected to the electric grid. Traditionally, such systems have been powered by diesel engine generator sets (DEGS), but also hybrid systems with photovoltaic and/or wind energy conversion systems (WECS) are becoming quite common nowadays. Hybrid energy systems can now be used to generate energy consumed in remote areas and stand-alone microgrids. This paper describes the design, simulation and feasibility study of a hybrid energy system for a stand-alone power system. A simulated model is developed to investigate the design and performance of stand-alone hydrogen renewable energy systems. The analysis presented here is based on transient system simulation program (TRNSYS) with realistic ventilation load of a large store. Design of a hybrid energy system is site specific and depends on the resources available and the load demand.