• Title/Summary/Keyword: Removal velocity

Search Result 488, Processing Time 0.026 seconds

Effects of Bio-stimulant Addition on Biological Wastewater Treatment Processes (생물학적 하·폐수처리 공정에서 생물촉진제 첨가의 영향)

  • Lee, Seockheon;Jung, Jin Young;Park, Ki Young
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.398-402
    • /
    • 2005
  • The enzyme Xeronine was investigated as a microbial activating substance in biological wastewater treatment processes. Xeronine as bio-stimulant was injected in the anaerobic sludge and the activated sludge treating wastewater in order to examine the effect of hidden benefits. Bio-stimulant did not show significant improvement of anaerobic treatablity. In the aerobic system, higher bio-stimulant dose condition resulted in slightly more removal of nitrogen and phosphorus. Floc aggregation and zone settling velocity as solid-liquid separation factors in activated sludge systems was enhanced by bio-stimulant. Effects of bio-stimulants injection on improvement of water quality and microbial activity did not clear in terms of normal operation conditions.

Numerical Study of Droplet Motion in a Microchannel with defferent contact angles (접촉각에 따른 마이크로채널 내에서의 액적 거동에 대한 수치적 연구)

  • Choi, Ji-Young;Son, Gi-Hun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.656-657
    • /
    • 2008
  • The droplet dynamics in a hydrophilic/hydrophobic microchannel, which is applicable to a typical proton exchange membrane fuel cell (PEMFC), is studied numerically by solving the equations governing conservation of mass and momentum. The liquid-gas interface or droplet shape is determined by a level set method which is modified to treat contact angles. The matching conditions at the interface are accurately imposed by incorporating the ghost fluid approach based on a sharp-interface representation. The effects of contact angle, inlet flow velocity, droplet size and side wall on the droplet motion are investigated parametrically. Based on the numerical results, the droplet dynamics including the sliding and detachment of droplets is found to depend significantly on the contact angle. Also, a droplet removal process is demonstrated on the combination of hydrophilic and hydrophobic surfaces.

  • PDF

Solid-liquid two phase helica l flow in a Rotating Annulus (Slim hole 환형관내 고-액 2상 유동에 관한 연구)

  • Han, Sang-Mok;Woo, Nam-Sub;Hwang, Young-Kyu;Kim, Young-Ju
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.369-372
    • /
    • 2008
  • An experimental study is carried out to study two-phase vertically upward hydraulic transport of solid particles by water in a vertical and inclined (0${\sim}$60 degree) concentric annulus with rotation of the inner cylinder. Rheology of particulate suspensions in shear-thinning fluids is of importance in many applications such as particle removal from surfaces, transport of proppants in fractured reservoir and cleaning of drilling holes, and so on. Annular fluid velocities varied from 0.2 m/s to 1.5 m/s for the actual drilling operational condition. Macroscopic behavior of solid particles, averaged flow rate, and particle rising velocity are observed. Main parameters considered in this study were radius ratio, inner-pipe rotary speed, fluid flow regime, and particle injection rate. For both water and CMC solutions, the higher the concentration of the solid particles is, the larger the pressure gradients become

  • PDF

Study on Optical Properties of Lithium Niobate Using CMP (화학기계적 연마에 의한 리튬니오베이트의 광학 특성에 관한 연구)

  • Jeong, Suk-Hoon;Kim, Young-Jin;Lee, Hyun-Seop;Jeong, Hae-Do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.3
    • /
    • pp.196-200
    • /
    • 2009
  • Lithium niobate ($LN:LiNbO_3$) is a compound of niobium, lithium and oxygen. The characteristics of LN are piezoelectricity, ferroelectricity and photoelectricity, and which is widely used in surface acoustic wave (SAW). To manufacture LN devices, the LN surface should be a smooth surface and defect-free because of optical property, but the LN material is processed difficult b traditional processes such as grinding and mechanical polishing (MP) because of its brittleness. To decrease defects, chemical mechanical polishing (CMP) was applied to the LN wafer. In this study, the suitable parameters such as down force and relative velocity, were investigated for the LN CMP process To improve roughness, the LN CMP was performed using the parameters that were the highest removal rate among process parameters. And, evaluation of optical property was performed by the optical reflectance.

Membrane Filtration Technology for Drinking Water Treatment & Night Soil Treatment

  • Kato, Yasuhiko
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.155-170
    • /
    • 1998
  • 1. The flux for hydrophilic CA membrane is higher than that for hydrophobic PES membrane at any operating conditions. The difference in bpth fluxes becomes greater as the water recovery is lower. 2. Backwash pressure should be more than twice as high as filtration pressure in order to maintain the higher flux. Backwash frequency is independent of the flux when the UF is operated under the same water recovery. 3. The relatively lower crossflow velocity of around 0.1 m/s would be appropriate because of the lower energy consumption per treated water. 4. The membrane fouling occurring at high turbidity and high concentration of organic compounds in raw water can reduce the flux and increase the removal of the organic compounds. 5. It is confirmed by the pilot plant testing that the UF by using the CA membrane module was well applicable to the drinking water treatment.

  • PDF

Tribological Characteristics of Conditioning Methods on Polishing Pad (컨디셔닝 방식에 따른 패드의 트라이볼로지적 특성)

  • Lee, Hyun-Seop;Park, Boum-Young;Seo, Heon-Deok;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.358-359
    • /
    • 2005
  • Chemical mechanical polishing(CMP) process depends on a variety of variables. Especially, surface roughness of pad plays a key role in material removal in CMP in terms of transportation ability of pores and real contact area. The surface roughness is deteriorated with polishing time by applied pressure and relative velocity. In this reason, diamond conditioner has been used to maintain the roughness on the pad. The authors try to investigate the correlation between pad roughness and frictional behavior by comparing ex-situ conditioning with in-situ conditioning.

  • PDF

The Effective Factors of n Foam Generation Using Foam Condensate (포말 농축물에 의한 포말 생성의 영향인자)

  • SUH Kuen-Hack;SHIN Jeong-Sik;LEE Ju-Hwa
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.509-514
    • /
    • 2003
  • We performed the experiment to determine the effective factors, such as the initial concentration of protein, pore size of air distributor, SAV (superficial air velocity), pH, salts and temperature related to foaming characteristics. The foam height in a foam generator was increased with the increase of the initial protein concentration and the decrease of pore size. As SAV was increased, the foam height was increased, and the optimum SAV was 0.84 cm/sec. The foam height was highest in the acid region and it was increased with the increase of salt concentration of NaCl and $NaHCO_3.$ The removal efficiencies of TSS (total suspended solid) and turbidity decreased with the increase of the initial protein concentration in the batch foam separator.

Numerical Analysis of A Vortex Cyclone in A Recirculating Aquaculture System (순환여과 양식장에서 와류형 분리기에 대한 수치적 검토)

  • Jeong, S.K.;Kim, E.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.36-41
    • /
    • 2005
  • This study investigated the performance of a vortex hydrocyclone for solid removal in a recirculating aquaculture system. In a fish-breeding industry, effluent water is mainly disposed by gravity sedimentation. Thus, a large settling tank and a lot of water are needed to purify effluent water. However, this typical method does not show consistent efficiency. In case of low efficiency, discharged water contains a lot of feeding sediments. This causes environmental problems. Instead of this typical method a hydrocylone is tested to discharge water which contains a lot of feeding sediments. In this paper, a hydrocyclone with low velocity and pressure drop in a recirculating aquaculture system is investigated.

  • PDF

The Effect on HRT and Hydraulic Characteristics of Biological Activated Carbon Fluidized Bed. (생물활성탄 유동상의 수리학적 특성과 체류시간의 영향)

  • 우달식;김선일;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.103-109
    • /
    • 1997
  • As the quality of raw water deteriorates, a number of additional treatment techniques have been developed and adapted to water treatment for producing a safe and aesthetically satisfactory drinking water. So, BACFB process as pretreatment in water supply is to be effective to remove dissolved organics. This study performed to find out the effects of HRT and hydraulic characteristics on BACFB reactors in water supply. The flow type in reactor was a high dispersion with complete mixing. As superficial velocity was increased, bed expansion was closed to theoretical values. It was considered that below 30 min HRT could operated to ensure the removal of dissolved organics.

  • PDF

Flow Analysis of Resin in an Extrusion Die for the Production of Medical Catheter Tubes (의료용 카테타 튜빙의 압출을 위한 다이내의 수지 흐름해석)

  • Lee, M.A.;Lyu, M.-Y.;Shin, D.J.;Kim, T.K.
    • Transactions of Materials Processing
    • /
    • v.24 no.2
    • /
    • pp.89-94
    • /
    • 2015
  • Medical catheter tubes are disposable devices that are inserted into the body cavities such as the pleura, trachea, esophagus, stomach, urinary bladder, ureter, or blood vessels for surgical procedures. Each hole of the inner tube is called a lumen, which is used as a passage for drug injections, waste discharge, polypus removal, blood transport, or injection of a camera or sensor. The catheter tube is manufactured by extrusion. The flow in the inner extrusion die affects the thickness and diameter of the tube. In the current study computer simulation of flow in an extrusion die for catheter tubing was performed. Velocity, pressure, shear rate, and shear stress were investigated and the die design was examined.