• Title/Summary/Keyword: Removal fusion

Search Result 115, Processing Time 0.023 seconds

Automatic Film Line Scratch Removal System using Spatial Information (공간 정보를 이용한 오래된 필름에서의 스크래치 제거 시스템)

  • Ko, Eun-Jeong;Kim, Kyung-Tai;Kim, Eun-Yi
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.6
    • /
    • pp.162-169
    • /
    • 2008
  • Film restoration is to detect the location and extent of defected regions from a given movie film, and if present, to reconstruct the lost information of each regions. It has gained increasing attention by many researchers, to support multimedia service of high quality. Among artifacts, scratch is the most frequent degradation. In this paper, an automatic film line scratch removal system is developed that can detect and restore all kind of scratches. For this we use the spatial information of scratches: The scratch in old films has lower or higher brightness than neighboring pixels in its vicinity and usually appears as a vertically long thin line. Our systems consists of scratch detection and scratch restoration. The scratches of various types are detected by neural network based texture classifier and morphology-based shape filter and then the degraded regions are restored using bilinear interpolation. To assess the validity of the Proposed method, it has been tested with all kinds of scratches, and then experimental results show that the proposed approach is robust to various scratches and efficient to apply a real film removal system.

Importance of Sperm Capacitation, Removal of Cumulus Matrix, Acrosome Reaction, and Sperm-egg Fusion in the Process of In Vitro Fertilization

  • Kim, Ki-Sun;Hwang, Kyung-A;Kim, Hyoung-Chin;Nam, Ki-Hoan;Choi, Kyung-Chul
    • Journal of Embryo Transfer
    • /
    • v.26 no.4
    • /
    • pp.287-296
    • /
    • 2011
  • Mammalian fertilization is a complex cascade process consisting of sperm migration through the female reproductive tract, physiological changes to sperm such as sperm capacitation and acrosome reaction, and sperm-egg interaction in the oviduct in vivo. On the other hand, in vitro fertilization (IVF) is a process by which egg cells are fertilized by sperm outside the body: in vitro. IVF has been used for a variety of purposes in reproductive biotechnology for human and animals. The discovery of sperm capacitation in 1951 promoted the development of IVF technology. In the initial stage of IVF, sperm capacitation in preincubation medium was shown to be essential to fuse with eggs. Besides, sperms should detour some of the in vivo regulations for IVF. This review introduces a general mammalian fertilization process, including sperm capacitation, removal of cumulus matrix, acrosome reaction, and sperm-egg fusion and focuses on the roles of key biochemical molecules, signal mechanisms, and genes involved during IVF and novel results of sperm-oocyte interaction elucidated in various gene-knockout mice models.

A Study on Residual Powder Removing Technique of Multi-Layered Graphene Based on Graphene One-Step Transfer Process (그래핀 원스텝 전사(Graphene One-Step Transfer) 공정 기반 다층 그래핀 잔여분말 제거 기술 연구)

  • Woo, Chae-young;Jo, Yeongsu;Hong, Soon-kyu;Lee, Hyung Woo
    • Journal of Powder Materials
    • /
    • v.26 no.1
    • /
    • pp.11-15
    • /
    • 2019
  • In this study, a method to remove residual powder on a multi-layered graphene and a new approach to transfer multi-layered graphene at once are studied. A graphene one-step transfer (GOST) method is conducted to minimize the residual powder comparison with a layer-by-layer transfer. Furthermore, a residual powder removing process is investigated to remove residual powder at the top of a multi-layered graphene. After residual powder is removed, the sheet resistance of graphene is decreased from 393 to 340 Ohm/sq in a four-layered graphene. In addition, transmittance slightly increases after residual powder is removed from the top of the multi-layered graphene. Optical and atomic-force microscopy images are used to analyze the graphene surface, and the Ra value is reduced from 5.2 to 3.7 nm following residual powder removal. Therefore, GOST and residual powder removal resolve the limited application of graphene electrodes due to residual powder.

Mycotic Abdominal Pseudoaneurysm due to Psoas Abscess after Spinal Fusion

  • Ryu, Dae Woong;Lee, Sam Youn;Lee, Mi Kyung
    • Journal of Chest Surgery
    • /
    • v.48 no.6
    • /
    • pp.443-446
    • /
    • 2015
  • A 36-year-old man, who had undergone thoracoscopic anterior spinal fusion using the plate system and posterior screw fusion three months previously, presented to our hospital with left flank pain and fever. Computed tomography indicated the presence of a psoas muscle abscess. However, after two days of percutaneous catheter drainage, a mycotic abdominal aortic pseudoaneurysm was detected via computed tomography. We performed in situ revascularization using a prosthetic graft with omental wrapping. Methicillin-resistant Staphylococcus aureus was identified on blood and pus culture, and systemic vancomycin was administered for one month. Although the abscess recurred, it was successfully treated with percutaneous catheter drainage and systemic vancomycin administration for three months, without the need for instrumentation removal. The patient remained asymptomatic throughout two years of follow-up.

Screw Fixation without Fusion for Low Lumbar Burst Fracture : A Severe Canal Compromise But Neurologically Intact Case

  • Jang, Kun-Soo;Ju, Chang-Il;Kim, Seok-Won;Lee, Sung-Myung
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.128-130
    • /
    • 2011
  • The low lumbar spine is deeply located in flexible segments, and has a physiologic lordosis. Therefore, burst fractures of the low lumbar spine are uncommon injuries. The treatment for such injuries may either be conservative or surgical management according to canal compromise and the neurological status. However, there are no general guidelines or consensus for the treatment of low lumbar burst fractures especially in neurologically intact cases with severe canal compromise. We report a patient with a burst fracture of the fourth lumbar vertebra, who was treated surgically but without fusion because of the neurologically intact status in spite of severe canal compromise of more than 85%. It was possible to preserve motion segments by removal of screws at one year later. We also discuss why bone fusion was not necessary with review of the relevant literature.

Estimation of GHGs Emission to Improvement of Facility Efficiency in the Food wastewater Treatment Process (식품폐수처리시설의 설비효율 개선에 따른 온실가스 배출량 평가)

  • An, Sang-Hyung;Song, Jang-Heon;Kim, San;Chung, Jin-Do
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.378-384
    • /
    • 2019
  • In the food wastewater treatment facilities, the water quality improvement effect and the greenhouse gas emission amount followed by the change in electricity usage through a change of the aeration tank ventilation system were evaluated. also, the amount of greenhouse gas emission followed by the change in electricity usage through the change of the sludge dewatering, storage, transporting method was also evaluated. The total GHG emission from food wastewater treatment facility improvement were divided into direct emissions from the treatment processes and indirect ones from electricity usage. The water quality improvement effect of wastewater treatment plant was found to be 63.3% for BOD removal rate, 42.0% for COD removal rate, 71.0% for SS removal rate and 39.6% for T-N removal rate. and according to the results of calculating output by applying both direct emissions of greenhouse gas (Scope 1) and the indirect emission (Scope 2) of greenhouse gas followed by changes in power consumption. It was estimated that there was a total of 276.0tCO2eq./yr(7.5%) greenhouse gas reduction effect from 3,668.8tCO2eq./yr before improvement to 3,392.8tCO2eq./yr after improvement. In this result is not due to the effects of water quality improvement of emission source, but because the reduction in electricity use has reduced the amount of greenhouse gas emissions.

A Study on Comparision of the Quantity of Phoria as Way to Separation of Binocular Fusion (양안융합의 분리 시간에 따른 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.331-337
    • /
    • 2014
  • Purpose: This is a comparative experimental study on the amount of phoria by the removal time of binocular fusion. In this study, three tests were used for phoria test like Howell test, Thorington test and developed 3D polarizing test. Methods: In this study, it was considered the removal time of binocular fusion for measuring phoria. The three methods were used for measuring quantity of phoria: Howell test, Thorington test and developed 3D Polarizing test. The measurements progressed quickly to avoid eye-strain. So we designed the test charts for marking 3D display modules and the apparatus inserted lenses, like Maddox lens and prism, which are compatible with three phoria tests. The phoria at the moment separation was measured when the binocular fusion was broken through the apparatus and the that at the stable separation was measured when activity of the separated two images like indicated box and figure on horizontal axis stopped. Results: There were statistically significant difference between quantity of phoria at moment separation and that at stable separation. Amount of phoria at moment separation was relatively larger than amount of that at stable separation. In result in exophoria, the quantity of phoria at moment separation was higher than that at stable separation, and in phoria measured by developed 3D polarizing test, it shows the similar results at two condition. Conclusions: For exophoria, the amount of phoria at moment separation of binocular fusion was relatively larger than that at stable separation. The amount of difference between phoria values at moment separation and that at stable separation was alike among three phoria tests. Usually in working, there is no distinction between moment separation and stable separation. But there were definitely the difference between two ways to separate binocular fusion. Therefore, it is need for writing on prescription test name for measuring phoria and condition of separation of binocular fusion.

Single-Step Purification of Proteins of Interest from Proteolytically Cleaved Recombinant Maltose-binding Protein (MBP) Fusion Proteins by Selective Immunoprecipitation of MBP

  • Park, Jung-Hyun;Na, Shin-Young;Lee, Dong-Gun;Han, Byoung-Don;Kim, Kil-Lyong
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.3 no.2
    • /
    • pp.82-86
    • /
    • 1998
  • The maltose binding protein (MBP) fusion protein system is a versatile tool to express and isolate recombinant proteins in E. coli. In this system, MBP fusion proteins are efficiently isolated from whole cell lysate using amylose conjugated agarose beads and then eluted by competition with free maltose. Since MBP is a rather large molecule (∼42 kDa), for further experiments, the MBP part is usually proteolytically cleaved from the fusion protein and subsequently removed by ion-exchange chromatography or rebinding to amylose columns after washing out excess and MBP-bound maltose. In the present study, we have developed an improved method for the removal of cleaved MBP, which is advantageous over conventional methods. In this method, factor Xa cleaved MBP fusion proteins were incubated with Sepharose beads conjugated with MBP specific monoclonal antibodies and then precipitated buy centrifugation, resulting in highly purified proteins in the supernatant.

  • PDF

Ligamentum Flavum Hematoma in the Adjacent Segment after a long Level Fusion

  • Kim, Hyeun-Sung;Kim, Seok-Won;Lee, Sung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.58-60
    • /
    • 2011
  • Ligamentum flavum hematoma (LFH) is a very rare condition of dural compression; most are observed in the mobile cervical and lumbar spine regions. A 67-year-old man who had a long level interbody fusion at L3-S1 four years ago presented with symptoms suggestive of dural compression. Magnetic resonance imaging showed a posterior semicircular mass located at the adjacent L2-L3 level. After decompression of the spinal canal and removal of the mass lesion, pathological examination of the surgical specimen revealed a hematoma within the ligamentum. The patient fully recovered to normal status after surgery. Here, we report our experience with a LFH in the adjacent segment after a long level fusion procedure and discuss the possible associated mechanisms.

Isthmic Spondylolisthesis Associated with Foraminal Disc Herniation Treated by Anterior Lumbar Interbody Fusion

  • Lee, Dong-Yeob;Lee, Sang-Ho;Maeng, Dae-Hyeon;Jang, Jee-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.320-322
    • /
    • 2005
  • A 45-year-old man presented with lower back pain and pain in the right leg of 3years duration. A plain radiographic examination revealed grade I isthmic spondylolisthesis, with instability at L4-5. Computed tomography and magnetic resonance imaging demonstrated bilateral foraminal stenosis, with soft foraminal disc herniation on the right side at the L4-5 level. He underwent anterior lumbar interbody fusion[ALIF] with percutaneous posterior fixation[PF] at the L4-5 level. Without removing the posterior bony structures, removal of foraminal disc herniation and reduction of spondylolisthesis were successfully performed using ALIF with percutaneous PF. When there is no hard disc herniation or lateral recess stenosis, ALIF with percutaneous PF can be one of the treatment options for isthmic spondylolisthesis, even in the presence of foraminal disc herniation, as in our case.