• Title/Summary/Keyword: Removal capacity

Search Result 1,102, Processing Time 0.031 seconds

A study on the Characteristics of a Centrifugal Fan Vibration and Noise (Centrifugal Fan 송풍기의 진동.소음 특성에 관한 연구)

  • 김태형;김옥현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.999-1003
    • /
    • 1992
  • Because of low noise and small size with huge capacity, a centrifugal fan is widely used for ventilation, air-conditioner and so on, which are very near to human life. Because of the complexity of its vibration and noise generation mechanics, most of researches on them are based on experimental methods. This study is to characterize the centrifugal fan noise and vibration. It is considered that noise is composed of the structural vibration noise and the air flow induced aerodynamic noise. To decouple the structural vibration noise the centrifugal fan is masked with an adhesive tape, such that air blowing is prohibited thus only the structural vibration noise is extracted. The noise level and characteristics in the frequency domain are verified and compared with those of total mixed one. This study shows some significant results that the structural vibration noise has relatively narrow band power spectrum compared with the total mixed one and has a strong periodicity. The sound level is lowered about 5dB by the removal of air flow with the masked fan for an air-conditioner used in this study.

Biosorption of Lead(II) by Arthrobacter sp. 25: Process Optimization and Mechanism

  • Jin, Yu;Wang, Xin;Zang, Tingting;Hu, Yang;Hu, Xiaojing;Ren, Guangming;Xu, Xiuhong;Qu, Juanjuan
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.8
    • /
    • pp.1428-1438
    • /
    • 2016
  • In the present work, Arthrobacter sp. 25, a lead-tolerant bacterium, was assayed to remove lead(II) from aqueous solution. The biosorption process was optimized by response surface methodology (RSM) based on the Box-Behnken design. The relationships between dependent and independent variables were quantitatively determined by second-order polynomial equation and 3D response surface plots. The biosorption mechanism was explored by characterization of the biosorbent before and after biosorption using atomic force microscopy (AFM), scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, and Fourier transform infrared spectroscopy. The results showed that the maximum adsorption capacity of 9.6 mg/g was obtained at the initial lead ion concentration of 108.79 mg/l, pH value of 5.75, and biosorbent dosage of 9.9 g/l (fresh weight), which was close to the theoretically expected value of 9.88 mg/g. Arthrobacter sp. 25 is an ellipsoidal-shaped bacterium covered with extracellular polymeric substances. The biosorption mechanism involved physical adsorption and microprecipitation as well as ion exchange, and functional groups such as phosphoryl, hydroxyl, amino, amide, carbonyl, and phosphate groups played vital roles in adsorption. The results indicate that Arthrobacter sp. 25 may be potentially used as a biosorbent for low-concentration lead(II) removal from wastewater.

Study on Pressurized Diesel Reforming System for Polymer Electrolyte Membrane Fuel Cell in Underwater Environment (수중 환경에서 고분자 전해질 연료전지(PEMFC) 공급용 수소 생산을 위한 가압 디젤 개질시스템에 관한 연구)

  • Lee, Kwangho;Han, Gwangwoo;Bae, Joongmyeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.528-535
    • /
    • 2017
  • Fuel cells have been spotlighted in the world for being highly efficient and environmentally friendly. A hydrogen which is the fuel of fuel cell can be obtained from a number of sources. Hydrogen source for operating the polymer electrolyte membrane fuel cell(PEMFC) in the current underwater environment, such as a submarine and unmanned underwater vehicles are currently from the metal hydride cylinder. However, metal hydride has many limitations for using hydrogen carrier, such as large volume, long charging time, limited storage capacity. To solve these problems, we suggest diesel reformer for hydrogen supply source. Diesel fuel has many advantages, such as high hydrogen storage density, easy to transport and also well-infra structure. However, conventional diesel reforming system for PEMFC requires a large volume and complex CO removal system for lowering the CO level to less than 10 ppm. In addition, because the preferential oxidation(PROX) reaction is the strong exothermic reaction, cooling load is required. By changing this PROX reactor to hydrogen separation membrane, the problem from PROX reactor can be solved. This is because hydrogen separation membranes are small and permeable to pure hydrogen. In this study, we conducted the pressurized diesel reforming and water-gas shift reaction experiment for the hydrogen separation membrane application. Then, the hydrogen permeation experiments were performed using a Pd alloy membrane for the reformate gas.

A Study of On-line Cleaning Method for Increasing Efficiency in a Combustor (연소로 효율증진을 위한 on-line 세정 방법에 관한 연구)

  • Jang, Hyun-Tae;Han, Seung-Dong;Park, Tae-Sung;Cha, Wang-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1016-1022
    • /
    • 2010
  • An Experimental study of cleaning solution has been performed on a high capacity steam boiler burning heavy fuel oil to on-line cleaning of deposit. The deposit is mixture of soot, slag, ash, metal oxide and clinker. The traditional technology of deposit cleaning was carried hand-crafted. The conventional technology of boiler cleaning method is mechanical removal by the worker while the boiler shut down operation. In this experiment, the deposit of mixture of soot, slag, ash, metal oxide and clinker has been removed by the cleaning agents without shut down of boiler burning. This study found out the optimum cleaning solution composition. The best results have been obtained when the mixture of ammonium nitrate and $MgNO_3$ were used in cleaning solution. The various transition metal effect was investigated for optimum mixing condition. In this research, the metal compound additive of the clean solution compoition was obtained. The combustion efficiency was improved by on-line cleaning with derived clean solution compoition. On-line cleaning method prevents the fouling and corrosion in the boiler and heat exchanger.

Removal of Methylene Blue Using UV-C Pretreated Citrobacter freundii JH 11-2 and Bacillus pseudomycoides JH 2-2 Biomass

  • Gim, HaeWon;Cho, Min;Oh, Byung-Taek
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.2
    • /
    • pp.38-43
    • /
    • 2014
  • In this study, we evaluated the methylene blue (MB) adsorption potential of non-treated and UV-C pretreated bacterial biomass from aqueous solution. The UV-C pretreatment denature the biomass and has increased overall functional groups when compared to non-treated biomass. The biosorbent was exposed to various pH, biomass dose, and contact time. The results showed that the dried and UV-C pretreated biomass effectively removed MB within 30 min. Dried and UV-C pretreated biomass of Bacillus pseudomycoides JH 2-2 showed a adsorption of 858.2 and 1072.4 mg/g at optimum conditions (pH: 9.0, contact time: 30 min, biomass dose: 1 g/L). Similarly, dried and UV-C pretreated biomass of Citrobacter freundii JH 11-2 showed an adsorption 868.3 and 954 mg/g at optimum conditions (pH: 9.0, contact time: 10 min, biomass dose: 1.5 g/L). The changes in the functional groups of UV-C pretreated biomass could be responsible for enhanced adsorption of MB. The results obtained have shown that non-treated and UV-C pretreated biomass has a high adsorption capacity for MB dye and can be used as a low-cost biosorbent in wastewater treatments.

Development of the Pilot System for Radioactive Laundry Waste Treatment Using UV Photo-Oxidation Process and Reverse Osmosis Membrane

  • Park, Se-Moon;Park, Jong-Kil;Kim, Jong-Bin;Shin, Sang-Woon;Lee, Myung-Chan
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.506-511
    • /
    • 1999
  • The pilot system for radioactive liquid laundry waste was developed with treatment capacity, 1ton/hr and set up in the Yong Kwang unit #4. The system is composed of tank module, RO systems and a UV/$H_2O$$_2$photo-oxidation unit. The RO system consists of the BW unit (low-pressure RO for brackish water desalination) and the SW unit (high-pressure RO for seawater desalination). The BW unit possesses 4 RO membranes and it can reduce the feed water volume down to 1/10. This concentrated feed water can be reduced again up to 1/10 in its volume in the SW unit composed of 4 RO membranes. The UV/$H_2O$$_2$ photo-oxidation process unit was used for the detergent degradation. The operation of the pilot system was carried out and verified in its capability through the continuous operation and concentration operation using the actual liquid waste from the power plant. The design criteria and data for industrialization were yielded. The efficiency of the UV/$H_2O$$_2$ photo-oxidation process and the optimum operational procedure were evaluated. The decontamination factors for radioactive cobalt and cesium were measured. This on-site test showed the experimental result in the DF$\geq$300 and volume reduction factor$\geq$100.

  • PDF

LIDMOD3 Development for Design and Evaluation of Low Impact Development (저영향개발기법 설계 및 평가를 위한 LIDMOD3 개발)

  • Jeon, Ji-Hong;Seo, Seong-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.4
    • /
    • pp.382-390
    • /
    • 2018
  • In this study, the LIDMOD3 was developed to design and evaluate low impact development (LIDMOD). In the same fashion, the LIDMOD3 employs a curve number (NRCS-CN) method to estimate the surface runoff, infiltration and event mean concentration as applicable to pollutant loads which are based on a daily time step. In these terms, the LIDMOD3 can consider a hydrologic soil group for each land use type LID-BMP, and the applied removal efficiency of the surface runoff and pollutant loads by virtue of the stored capacity, which was calculated by analyzing the recorded water balance. As a result of Model development, the LIDMOD3 is based on an Excel spread sheet and consists of 8 sheets of information data, including: General information, Annual precipitation, Land use, Drainage area, LID-BMPs, Cals-cap, Parameters, and the Results. In addition, the LIDMOD3 can estimate the annual hydrology and annual pollutant loads including surface runoff and infiltration, the LID efficiency of the estimated surface runoff for a design rainfall event, and an analysis of the peak flow and time to peak using a unit hydrolograph for pre-development, post-development without LID, and as calculated with LID. As a result of the model application as applied to an apartment, the LIDMOD3 can estimate LID-BMPs considering a well spatical distributed hydroloic soil group as realized on land use and with the LID-BMPs. Essentially, the LIDMOD3 is a screen level and simple model which is easy to use because it is an Excel based model, as are most parameters in the database. This system can be expected to be widely used at the LID site to collect data within various programmable model parameters for the processing of a detail LID model simulation.

Predictors of Acute Postoperative Urinary Retention after Transvaginal Uterosacral Suspension Surgery

  • Son, Eun-Joo;Joo, Eunwook;Hwang, Woo Yeon;Kang, Mi Hyun;Choi, Hyun Jin;Yoo, Eun-Hee
    • Journal of Menopausal Medicine
    • /
    • v.24 no.3
    • /
    • pp.163-168
    • /
    • 2018
  • Objectives: To investigate the rate of postoperative urinary retention (POUR) and identify the risk factors for this complication in women who underwent transvaginal uterosacral suspension surgery. Methods: A retrospective chart review was conducted for 75 women who underwent transvaginal uterosacral suspension surgery with vaginal hysterectomy, repair of cystocele, and levator myorrhaphy with/without transobturator anti-incontinence surgery. POUR was defined as a need for continuous intermittent catheterization on the third day subsequent to removal of the urethral indwelling catheter. Results: Acute POUR was reported in 18 women (24.0%). Thirty-six of the 75 patients (48.0%) had undergone anti-incontinence surgery. Crude analysis revealed significant association between the following variables and the risk of POUR: hypertension, the lower average flow rate in the pressure-flow study (PFS), greater post-void residual (PVR) urine volume in PFS, and PVR >30% of the total bladder capacity (TBC) in PFS. In the logistic regression analysis, PVR >30% of the TBC in PFS was identified as the only significant predictor of POUR (odds ratio, 15.4; 95% confidence interval, 2.5-90.9; P = 0.003). Conclusions: The PVR >30% of the TBC in PFS was identified as the only predictive factor of acute POUR in women who underwent transvaginal uterosacral suspension surgery.

Development and Evaluation of Coal-dust Water Flocculant using Chitosan (키토산을 이용한 탄진수 응집제 개발 및 평가)

  • Hong, Woong-Gil;Nah, Jae-Woon;Jeong, Gyeong-Won
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.139-142
    • /
    • 2021
  • Coal-fired power plants use coal as the main raw material, and when a coal is moved, a dust generation and spontaneous ignition of coal occur. To prevent this, water is sprayed. As a result, wastewater called "coal-dust water" flows out of coal dust and water mixed together, causing environmental pollution. In this study, in order to solve this problem, we developed a natural flocculant that can purify water by aggregating fine dust using chitosan and tried to prove its applicability. It was found that the optimum flocculation concentration was 4 ppm by adding various concentrations of flocculant to the coal-dust water, and it was confirmed that the developed material had very good coal-dust flocculation capacity through permeability and coal-dust removal efficiency. In addition, the cytotoxicity of the flocculant was evaluated through the MTT assay and it was found that there is no toxicity at all. We believe that the flocculant developed in this study can effectively adsorb coal-dust without affecting human and natural ecosystems.

Removal of Reactive Dyes using Chitin-based Adsorbent PEI-chitin (키틴 기반 흡착제 PEI-chitin을 이용한 반응성염료의 제거)

  • Kim, Gyeong Min;Wang, Zhuo;Won, Sung Wook
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.232-238
    • /
    • 2019
  • Polyethylenimine-crosslinked chitin (PEI-chitin) was developed as a biosorbent to effectively remove dyestuffs from dye-containing wastewater. A representative reactive dye, Reactive Orange 16 (RO16) was used as a model dye. The effect of pH, isotherm, kinetic and desorption experiments were performed to evaluate the adsorption/desorption ability of PEI-chitin for RO16. As a result, the maximum adsorption capacity calculated by the Langmuir model was 266.3 mg/g at pH 2, and the time needed for adsorption equilibrium was evaluated to be about 20, 60, and 240 min for 50, 100, and 200 mg/L, respectively. The desorption experiments were carried out using various eluents such as ammonia/ethanol mixture, NaOH, $NaHCO_3$, and $Na_2CO_3$, and the highest desorption rate was 75.24% in the ammonia/ethanol mixture.