• Title/Summary/Keyword: Removal capacity

Search Result 1,115, Processing Time 0.03 seconds

Lead Biosorption by Biosorbent Materials of Marine Brown Algae U. pinnatifida, H. fusiformis, and S. fulvellum

  • LEE Mingyu;KAM Sangkyu;LEE Donghwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.6
    • /
    • pp.936-943
    • /
    • 1997
  • Biosorbents of nonliving, dried marine brown algae Undaria pinnatifida, Hizikia fusiformis, and Sargassum fulvellum were investigated for their lead biosorption performances. As the amount of biosorbent added was increased, the lead removal by biosorbent materials increased but the lead biosorption capacities decreased. However the lead biosorption capacity by the biosorbent materials increased with increasing initial lead concentration and pH in the range of $C_o\;10\~500\;mg/L$. Among the biosorbent materials used in this study, the lead biosorption capacity in the solutions with no pH adjustment decreased in the following sequence: U. pinnatifida > H. fusiformis > S. fulvellum. Equilibrium parameters based on Langmuir and Freundlich isotherm were determined. It was found that the lead biosorption by biosorbent materials were expressed by the Langmuir isotherm better than the Freundlich isotherm.

  • PDF

Determining the Single Most Vital Arc in the Maximum Flow Problem (최대유통문제의 단수치명호 결정 방법)

  • 정호연;안재근;박순달
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.25 no.2
    • /
    • pp.115-124
    • /
    • 2000
  • The most vital arc in the maximum flow problem is that arc whose removal results in the greatest reduction in the value of the maximal flow between a source node and a sink node. This paper develops an algorithm to determine such a most vital arc in the maximum flow problem. We first define the transformed network corresponding to a given network in order to compute the minimal capacity for each candidate arc. The set of candidate arcs for single most vital arc consists of the arcs whose flow is at least as great as the flow over every arc in a minimal cut. As a result we present a method in which the most vital arc is determined more easily by computing the minimal capacity in the transformed network. the proposed method is demonstrated by numerical example and computational experiment.

  • PDF

Evaluation on the Possibility of a Retrofitting Treatment Using Moving Media of Existing Wastewater Treatment (유동상 Media를 이용한 기존하수처리장의 Retrofitting 가능성 평가)

  • Ko, Tae-Ho;Park, Woon-Ji;Lee, Chan-Ki
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.133-139
    • /
    • 2005
  • In this study, as MBBR(Moving Bed Biofilm Reactor) process using waste tire media is suggested for retrofitting with advanced wastewater treatment and the removal property of organic matter and nutrient and the capacity of media are evaluated through long-term operation with pilot plant following seasons, the application capacity of retrofitting with MBBR process to a existing wastewater treatment is studied. As a result of the long-term operation of the process, it is proved that there is no loss and abrasion of media, and also that it is possible to secure the sufficient attached bio-mass. The values of organic matter and nutrient in effluent are suitable for the strict discharged water quality standards in every season including winter.

  • PDF

The Synthetic Melanin Nanoparticles Having An Excellent Binding Capacity of Heavy Metal Ions

  • Kim, Da Jeong;Ju, Kuk-Youn;Lee, Jin-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3788-3792
    • /
    • 2012
  • Spherical-shape melanin nanoparticles with good water-dispersibility were successfully synthesized by a simple oxidation polymerization of 3,4-dihydroxy-phenylalanin (DOPA) with $KMnO_4$. Similar features to those known from natural and synthetic melanin polymers were observed from prepared melanin nanoparticles by FT-IR, UV-Vis., and ESR spectroscopic methods. Their binding ability with several heavy metal ions from aqueous solution was quantitatively investigated, and the maximum binding capacities with melanin nanoparticles to lead, copper, and cadmium ions were obtained as 2.45, 2.17 and 1.88 mmol/g, respectively, which are much larger values than those reported from natural and synthetic melanin polymers. The large binding capacity and fast binding rate of melanin nanoparticles to metal ions can make them an excellent candidate for the remediation of contaminated water.

Biosorption of Pb and Cu by Marine Algae (해조류를 이용한 Pb 및 Cu의 흡착)

  • 서근학;안갑환;조문철;김병진;진형주;홍용기
    • KSBB Journal
    • /
    • v.13 no.4
    • /
    • pp.444-448
    • /
    • 1998
  • Biosorption of Pb and Cu was evaluated for 23 species of marine algae collected from a Korean coast. Among a variety of species for biosorbent potential, Hypnea charoides showed the highest capacity for Pb. An adsorption equilibrium was reached in about 2 hr for Pb and 30 min for Cu. The uptake capacity was 192.8 mg Pb/g biomass and 256 mg Cu/g biomass, respectively. The adsorption parameters for Pb and Cu were determined according to Langmuir model. With an increase in pH value, more negative sites are becoming avaliable for adsorption of pH and Cu, thus the removal of Pb and Cu increases at alkaline conditions. The selectivity of mixture solution shows the uptake order of Pb>Cu>Cr>Cd. When Ca concentration increases in Pb solution, Pb was selectively adsorbed.

  • PDF

Chromium(VI) Removal from Aqueous Solution using Acrylic Ion Exchange Fiber (아크릴계 이온교환섬유를 이용한 수중 크롬(VI) 제거)

  • Nam, Aram;Park, Jeong-Ann;Do, Taegu;Choi, Jae-Woo;Choi, Ungsu;Kim, Kyung Nam;Yun, Seong-Taek;Lee, Sanghyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.112-117
    • /
    • 2017
  • Ion exchange fiber, PADD was synthesized by the reaction between PAN based acrylic fiber and DETA with $AlCl_3{\cdot}6H_2O$, and was analyzed by FT-IR and SEM to investigate its characteristics. The experimental results of Cr(VI) removal by PADD were better fitted with Langmuir adsorption isotherm, and the maximum uptake value ($Q_{max}$) was calculated to be 6.93 mmol/g. The kinetic data can be well described by Lagergen pseudo-second order rate model. The Cr(VI) adsorption capacity of PADD was 4.11 mmol/g at pH 2, which shows the effect of pH changes on the removal of Cr(VI). The adsorption selectivity of Cr(VI) was higher than phosphate and As(V). Total ion exchange capacity of PADD was 4.70 mmol/g, which was measured by acid-base back titration.

Innovative Technology for Removal of Dispersants used in Oil Spill Remediation Using the Magnetic Separation (자성 분리를 이용한 해상 유류오염제어에 사용되는 유화제를 제거하는 새로운 기술에 대한 연구)

  • Chun, Chan-Lan;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.679-688
    • /
    • 2000
  • Dispersants, which are used to break water-in-oil emulsions and to remediate oil-spills, are another water pollutants. In this study, magnetic separation technology was applied to remove dispersants from the sea. Magnetite and maghemite were used as magnetic sorbents and SDDBS, an anionic surfactant and Triton X-100, a nonionic surfactant, were employed as dispersants. Batch experiments were undertaken to study the sorption capacity and sorption equilibrium, and water-bath experiments were conducted to simulate the real situation and to describe the recovery of magnetic particles by the permanent magnet or electromagnet. Maghemite has rather constant removal efficiency for dispersants, regardless of surfactant species. On the other hand, removal efficiency by magnetite is higher for anionic surfactant than maghemite and is higher in distilled water than in seawater which contains more ions. The sorption of dispersants to magnetite is explained by electrostatic attraction and that of maghemite is described not only by electrostatic attraction, but also by structural characteristics that provide high sorption ability and surface condition. Water bath experimental results showed that recovery efficiency of magnetic particle after sorption for dispersants is nearly 100%. It is suggested that this magnetic separation technology is an effective way of dispersant removal because of short operating time, high sorption capacity, and high recovery efficiency of sorbents.

  • PDF

Evaluations of Grit Removal Efficiency of Tornado Block-Type Vortex Grit Separator (토네이도 블록형 선회류 침사제거기의 침사제거효율 평가)

  • Kim, Jong-Je;Lee, Bum-Soo;Yeom, Cheol-Min;Lim, Hee-Jae;Jung, Seok-Mo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.288-294
    • /
    • 2005
  • This study was conducted to evaluate the grit removal efficiency of tornado block-type vortex grit separator. Vortex grit separator was manufactured for this study, and it was characterized by the impeller and tornado block installed in separator. Impeller was installed to increase water velocity in the separator and tornado block was installed to increase the grit lifting efficiency. Pilot study was also conducted in A sewage treatment plant (STP) in Gyeonggi province from November 2003 to May 2004 (64 days). Major findings are as follows. 1. Impeller was proven to increase water velocity in the grit separator, especially in low flow rate. This influence will increase separation ratio of organics from grits, preventing those organics from sedimentation. 2. Sand (with 0.2~0.3mm size) removal efficiency was over 98 % and 96 %, at the flow rate of $500m^3/day$ and $750m^3/day$ under the condition that impeller rotation velocity kept at 15 rpm. Originally that grit separator was designed to have the capacity of $500m^3/day$. $750m^3/day$ was tried to investigate the performance of this type of grit separator under overload condition. Stable grit removal was still available to the extent of 150% of designed capacity. 3. It took less than 3 minutes for the grit separator to completely lift out 3 kgs of 0.2-0.3 mm sized, settled sand at the bottom to 2,060 mm high above water surface. But it showed the tendency to spend a little more time on lifting the grit as the grit size and the vertical height of the lift increased. 4. During experimental duration in A STP, it was found that the average amount of inlet grit was about 981 g/day (160~1,685 g/day) under $500m^3/day$ of operation condition, but it varied so severely during the experimental duration. After classification of discharged grit according to its size, grit with 0.3-0.42 mm size was found as largest part of output.

Assessments of Dissolved Rare Earth Elements and Anthropogenic Gadolinium Concentrations in Different Processes of Wastewater Treatment Plant in Busan, Korea (부산 하수처리장에서 공정별 용존 희토류 원소의 농도 및 인위적 기원 가돌리늄의 배출량 평가)

  • Lim, Ijin;Ryu, Jong-Sik;Lee, Joonyeob;Lee, Jun-Ho;Cho, Hyung-Mi;Kim, Taejin
    • Journal of the Korean earth science society
    • /
    • v.43 no.2
    • /
    • pp.303-311
    • /
    • 2022
  • Gadolinium, commonly used as a contrast agent for magnetic resonance imaging (MRI), is discharged into aquatic environments without removal after treatment in wastewater treatment plants (WWTPs) because of its high stability. In this study, we collected water samples from Suyeong WWTP, Busan, to investigate the dissolved rare earth element (REE) removal capacity of each wastewater treatment process and to evaluate the discharge of anthropogenic Gd (Gdanth) from effluents. As wastewater passed through each stage of treatment, the concentrations of light REEs (La-Eu) decreased, whereas those of heavy REEs (Tb-Lu) were relatively consistent. Negative Sm anomalies (<1) were observed in several samples, indicating that Sm can be removed by adsorption onto particles or phosphate during the biological removal process. Positive Gd anomalies (149±50, n=9) were observed in all samples. The ratios of Gdanth concentrations to measured Gd concentrations in all wastewater treatment processes were higher than 97%. This indicates that Gdanth was discharged to the Suyeong River without removal during the wastewater treatment process. Considering the daily treatment capacity in each process, the total flux of Gdanth was estimated to be 259 mmol/day. Our results suggest that mid- and/or long-term monitoring of Gd is needed because Gdanth is continuously discharged into Suyeong Bay through WWTPs.

A Study on Time-Expanded Network Approach for Finding Maximal Capacity of Extra Freight on Railway Network (시간전개형 네트워크 접근법을 이용한 기존 열차시각표를 고려한 추가적 철도화물 최대수송량 결정에 관한 연구)

  • Ahn, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3706-3714
    • /
    • 2011
  • This study deals with the algorithm to finding the maximum capacity and their schedule of extra freight while honoring planned timetable of trains on railway network. Time-expanded network, a kind of space-time graph, can be shown both planned train timetable and dynamic features of given problem. Pre-processing procedure is a series of infeasible arcs removal from time-expanded network honoring planned timetable. In the result, this preprocessing transforms dynamic features of given problem into static maximal flow problem which can be easily solved.