• 제목/요약/키워드: Removal Efficiency of pollutants

검색결과 336건 처리시간 0.033초

섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성 (Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants)

  • 정진호;류승한;권순덕;조윤현
    • 한국염색가공학회지
    • /
    • 제35권4호
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

축산폐수 생물학적 처리수의 후처리를 위한 물리·화학적 단위 공정 비교 (Comparisons of Physical and Chemical Methods for Dealing with Biologically Pre-Treated Livestock Wastewater as a Post-Treatment)

  • 최용수;홍석원;권기한;정일호
    • 한국물환경학회지
    • /
    • 제20권2호
    • /
    • pp.110-119
    • /
    • 2004
  • The combination of biological and physical/chemical technologies is a promising technique to reduce highly concentrated pollutants in livestock wastewater. It is suggested to treat livestock wastewater efficiently as follows: firstly, biodegradable organic matters, nitrogen and some of phosphorus should be removed by a biological treatment process and then residual non-biodegradable organic matters, color and phosphorus be eliminated by physicochemical technologies. In this study, therefore, the integrations of chemical coagulation, activated carbon adsorption, Fenton oxidation and ozonation were evaluated to provide appropriate post-treatment processes for biologically pre-treated livestock wastewater. After chemical coagulation followed by ozonation or Fenton oxidation process, the quality of treated wastewater could meet the discharge limit in Korea. However, a yellowish brown color still remained in the treated wastewater after a single method such as coagulation and Fenton oxidation was applied. The ozonation was found to be the most effective technology for the decolorization. Neither simple biological nor physicochemical treatment provides adequate decolorization and sufficient depletion of organics in livestock wastewater so far. Consequently, the integration of Fenton oxidation and ozonation with a biological treatment process is recommended to treat livestock wastewater in terms of removal efficiency.

하수방류수 재이용 MF/RO 공정에서 가압식 MF의 전처리 성능 향상 방안 연구 (Improvement of Pressurized MF Pretreatment in MF/RO Process for Reuse)

  • 나유미;박용민;이양우;김원경;김지태;조일형
    • 멤브레인
    • /
    • 제24권5호
    • /
    • pp.350-357
    • /
    • 2014
  • 하수방류수 재이용을 위한 RO 전처리로 부유물질 및 콜로이드 물질의 제거를 위해 가압식 MF를 사용하였다. 남양주 J 하수처리장의 생물학적 처리와 모래여과를 거쳐 방류되는 방류수를 원수로 사용하였으며 100 톤/일 규모의 pilot plant를 1년 이상 운전하여 성능을 검토하였다. 가압식 MF에 의해 원수 수질 및 온도의 변화에 상관없이 flux 40 LMH 운전이 가능하였으며 전처리로 응집제를 넣어 용존 유기물을 응집할 경우 60 LMH 운전이 가능하였다. RO 공정에서 장기간 정지 이후 운전을 재개하였을 때 1단 pressure drop이 급격히 증가하는 현상이 나타났고 이러한 결과는 배관 내 형성된 유기물과 이온물질의 복합오염물질이 1단 RO막에 침적된 결과로 사료된다.

Air Pollution Protection onboard by Seawater and Electrolyte

  • An Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.93-101
    • /
    • 2006
  • This research makes a new attempt to apply the activated seawater by electrolysis in the development of two-stage wet scrubber system to control the exhaust gas of large marine diesel engines. First, with using only seawater that is naturally alkaline (pH typically around 8.1). the $SO_2\;and\;SO_3$ are absorbed by relatively high solubility compared to other components of exhaust pollutants, and PM (Particulate Matter) is removed through direct contact with sprayed seawater droplets. Besides, the electrolyzed alkaline seawater by electrolysis, which contains mainly NaOH together with alkali metal ions $(i.e.\;Na^+,\;Mg^{2+},\;Ca^{2+})$, is used as the absorption medium of NOx and $CO_2$. Especially, to increase NOx absorption rate into the alkaline seawater. nitric oxide (NO) is adequately oxidized to nitrogen dioxide $(NO_2)$ in the acidic seawater, which means both volume fractions are adjusted to identical proportion. The results found that the strong acidic seawater was a valid oxidizer from NO to $NO_2$ and the strong alkaline seawater was effective in $CO_2$ absorption In the scrubber test, the SOx reduction of nearly $100\%$ could be achieved and also led to a sufficientPM reduction. Hence, the author believes that applying seawater and its electrolyte would bring the marine air pollution control system to an economical measure. Additionally it is well known that NOx and SOx concentration has a considerable influence on the $N_2O$ emission of green house gas. Although the $N_2O$ concentration exhausted from diesel engines is not as high, the green house gas effect is around 300 times greater than an equivalent volume of $CO_2$. Therefore, we investigated the $N_2O$ removal efficiency with using the electrolyzed seawater too. Finally this research would also plan to treat the effluent by applying electro-dialysis and electro-flotation technique s in the future.

오존에 의한 활성오니처리 방류수의 탈색처리 연구 (Decolorization System of Effluent of Activated Sludge Process Using Ozone)

  • 최희철;곽정훈;최동윤;권두중;김형호;이덕수;강희설;최영수;천상석
    • 한국축산시설환경학회지
    • /
    • 제8권3호
    • /
    • pp.153-158
    • /
    • 2002
  • 활성오니처리를 한 양돈폐수 방류수의 잔여오염물질을 정화하고 색도 구성물질을 분해하고자 4개의 오존처리조와 폭기조, 침전조 등으로 구성된 처리소 총 처리조용량이 594.5l이고 1일 200l씩 처리가 가능한 20g/hr의 오존발생기가 부착된 오존이용 탈색 시스템을 개발하였으며 그 시험 결과는 다음과 같다. 1. 오존처리시 온도는 반응열에 의하여 처리전 31.$0^{\circ}C$에서 처리중에는 41.9$^{\circ}C$까지 증가하였으며 pH도 처리 과정 중에 계속적으로 증가했다. 2. 산화환원전위차는 처리전에 148㎷였으나 처리중에 증가하여 330㎷까지 증가하였으며 처리가 완료된 후 방류조에서는 다시 감소하였다. 3. BOD의 경우 처리전 11mg/l였으나 처리후에 1mg/l로 낮아졌으며 CO $D_{MN}$ 의 경우에도 83mg/l에서 1.0mg/l으로 낮아졌다. 4. 활성오니처리 방류수의 색도는 442도였으나 오존처리후에는 색도가 6도로 98.6%의 높은 색도제거효율을 보였다.

  • PDF

물옥잠을 이용한 수중처리방법에 의한 농공단지 폐수처리에 관한 연구 (Study on the Wastewater Treatment by Floating Aquatic Plant System Using Water Hyacinth for the Industrial Complex in Rural Area)

  • 윤춘경;김형중;류재현;여운식
    • 한국농공학회지
    • /
    • 제39권3호
    • /
    • pp.64-71
    • /
    • 1997
  • Floating aquatic plant system using water hyacinth was applied to examine feasibility as a wastewater treatment system for the industrial complex in rural area. The wastewater from the industrial complex does not likely contain toxic pollutants because the industries which generate wastewater with toxic compounds are not allowed to move in. Pilot plant was installed at Baeksuk Nongkong Danzi in Chunahn-City, Chunchungnam - Do , and field study was performed during summer and fall of 1996. Hydraulic loading rate was 0. $0.19m^3/m^2$.day. The effluent concentration of DO was higher than influent, and it implies that 0.6m depth reactor was reaerated enough to increase DO level. The influent concentration of BOD varied significantly from less than 30 to 120mg/${\ell}$ during the study period, however, effluent concentrations were generally lower than the water quality standard and removal efficiency was up to 85%. The influent concentration of COD also showed wide variation from less than 40 to 160mg/${\ell}$ and effluent concentration was higher than water quality standard when influent concentration was over l00mg/${\ell}$. The influent concentrations of T-N and T-P were lower than water quality standard and no further treatment was required, and these compounds were also removed in the system. Although some improvement and refinement are still required, overall* the floating aquatic plant system was proved to be feasible to apply to treat wastewater from industrial complex in rural area.

  • PDF

유역형상과 수리특성을 고려한 경험론적 유달부하식 개발 (Development of the Empirical Model for Estimating the Delivered Pollutant Loads Considering Geomorphic and Hydraulic Characteristics)

  • 박지형;공동수;민경석
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.913-919
    • /
    • 2007
  • This study was conducted to develop a model equation to estimate the delivered point and nonpoint pollutant loads, which are critical factor to determine the water quality of watersheds. The model equation was developed by considering various factors such as biological removal and delivered distance of pollutants, basin shape and geomorphic runoff condition. The parameters for the model equation were estimated in 3 periods, which are October to March, April to June, and July to September. As a parameter, ${\alpha}_p$, ${\alpha}_n$, ${\beta}$, a and b for $BOD_5$-delivered pollutant loads were estimated to be 0.010~0.0155, 0.051, -0.033, 0.018~0.050 and 0.93, respectively. For T-N, ${\alpha}_p$, ${\alpha}_n$, ${\beta}$ a and b were estimated to be 0.0060~0.0140, 0.014, -0.02, 0.044~0.079 and 0.93, respectively. The same parameters for T-P were estimated to be 0.0160, 0.014, -0.0250, 0.015 and 1.21, respectively. The relationship, $E^2$ (Model efficiency), between observed and calculated delivered pollutant loads showed 0.65 for $BOD_5$, 0.81 for T-N, and 0.66 for T-P, respectively. Consequently, the model equation is effective to estimate delivered pollutant loads for TMDL.

와류형 비점오염저감시설의 유입 조건에 따른 제거효율 연구 (A Study on the Removal Efficiency Depending on Changes of Inflow Conditions in Vortex typed Non-point Pollutants Treatment Facility)

  • 윤근호;최계운;이민희
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.494-494
    • /
    • 2012
  • 비점오염이란 도시, 도로, 농지, 산지, 공사장 등 불특정 장소에서 발생되는 오염을 말하며 건기 시에는 오염물질이 토지에 축적되었다가 강우 발생 시 강우와 함께 유출되어 관리에 많은 어려움이 있다. 유출된 오염물질은 특별한 전처리 없이 하천이나 호소로 유입되어 각종 수질오염, 부영양화 및 생활환경에 많은 영향을 받게 되며 상수원수에 문제가 발생하게 된다. 비점오염원의 특징은 초기강우 유출수는 고농도이며 토사, 협잡물 등이 많이 포함되어 있다. 초기강우 발생형태는 수로의 형태, 노면상태 유역현상 및 강우도달시간 등 유역의 특성에 따라서 달라지며, 토지이용상황, 하수도 정비여부 등에 따라서 오염물질의 종류와 농도가 변한다. 도시지역과 도로주변에는 먼지, 쓰레기, 마모된 타이어 등이 축적되며, 임야 및 산림에서는 비료, 축분, 대기오염물질의 강하물 등이 축적이 되어 강우 시 빗물에 씻겨 인근 수계로 직접 방류된다. 팔당상수원 비점오염원 최적관리사업 기본계획 및 타당성조사사업이 실시되어 비점오염저감시설의 설치대상 대표지점이 선정되었다. 그리고 각 배수구역의 특성에 맞는 최적관리기술이 제시되었다. 하지만 몇몇 시설들은 기대한 결과에 못 미치는 성과를 내고 있다. 따라서 이번 연구에서는 이러한 비점오염저감시설의 시설형 중 하나인 와류형 비점오염저감시설의 운용에 따른 효율성 분석에 관한 연구를 실시하였다. 실험장치는 현재 운영되고 있는 와류형 비점오염저감시설 참고하여 실험장 조건에 맞춰 1/4축적의 정상모형을 제작하였고 저감시설로 유입되는 원수의 유량과 단차를 변화시켜 실험하였다. 저감시설의 유입조건이 변하게 되면 시설 내 유속, 체류시간 등 운전조건이 바뀌게 되므로 제거효율도 변하게 될 것이다. 저감효율산정은 시설로 유입된 유입수와 유출수의 SS농도를 이용하여 산정하였다. 와류형저감시설의 SS제거효율을 연구한 결과, 모형에서 유량 $0.0016m^3/s$, 단차 10cm 인 조건에서 8.7%로 가장 높은 효율이 측정되었다. 이를 원형에서의 조건으로 환산하면 유량 $0.0512m^3/s$, 고수조와 저감시설의 단차 40cm일 경우 가장 높은 효율이 나타난다. 이와 같은 이유는 시설에 유입되는 유량이 증가 할수록 내부의 유속이 증가해 저감시설 내 처리수의 체류시간 감소와 교란이 발생하여 저감효율이 떨어지는 것으로 사료된다.

  • PDF

침투도랑 유지관리를 통한 도시 강우유출수 처리 성능 평가 (Performance assessment of an urban stormwater infiltration trench considering facility maintenance)

  • 나쉬 제트 레예스;프란츠 케빈 헤로니모;최혜선;김이형
    • 한국습지학회지
    • /
    • 제20권4호
    • /
    • pp.424-431
    • /
    • 2018
  • 강우유출수 내 포함된 입자상 물질, 유기물, 영양물질, 중금속 등의 오염물질은 수계에 악영향을 미친다. 이러한 강우유출수 내 포함된 오염물질 감소와 처리를 위해 최적관리기법(BMP)을 도입하고 있으며, 비용효율적인 방법으로 평가되고 있다. 하지만, 잘못된 설계와 유지관리 부족은 시설의 성능을 저하시켜 원활한 기능을 수행하지 못하고 있는 실정이다. 따라서, 본 연구에서는 지속적인 유지관리가 진행된 침투도랑(IT)의 시설에 대한 평가를 수행하였다. 2009년부터 2016년까지 총 41회의 모니터링을 수행하였으며 침투도랑(IT)의 오염물질 저감효율 평가를 수행하였다. 수질 및 수문학적 분석결과, 시설에 유입되는 유입수는 단위 오염 부하량에 영향을 미치는 요인으로 나타났다. 또한, 계절의 변화는 오염물질 저감능력에 영향을 미치는 것으로 분석되었다. 여름철 강수량 및 강우강도의 증가로 인해 Overflow 및 유량의 증가가 발생되었으며, 이로 인해 저감효율이 감소하였다. 또한, 겨울철 낮은 온도로 인해 여재 및 화학적 메카니즘의 효과 감소로 오염물질 저감 효율이 감소되는 것으로 분석되었다. 침투도랑(IT)의 유지관리는 시설의 효율에 영향을 미치는 것으로 평가되었다. 시설 설치 이후 2년 동안 유지관리 부족으로 오염물질 저감효율이 낮은 것으로 나타났으며, 일부 모니터링에서 지오텍스타일 내 제거 되지 않은 퇴적물로 인해 오염물질 저감효율의 감소를 보였다. 본 연구를 통하여, 시설의 유지관리는 오염물질 저감효과에 영향을 미치는 것으로 나타났으며, BMP 시설의 최적 유지관리 기간 및 방법 등은 향후 유용한 자료로 사용 될 수 있을 것으로 사료된다.

통수실험에 의한 갯벌의 오염물질 정화능력 평가 (Evaluation to Purification Capacity of Pollutants by Column Test with the tidal flat sediment)

  • 김종구;유선재
    • 한국환경과학회지
    • /
    • 제9권3호
    • /
    • pp.223-228
    • /
    • 2000
  • 충남 서천군 춘장대에서 채취한 갯벌을 통수칼럼에 넣고 오염물질 정화능력을 평가 해 보았다. 각 칼럼에 사용된 시료수는 하수를 G2여과지(6$\mu\textrm{m}$)로 여과한 여액(R1), 생하수를 GF/C여과지(12$\mu\textrm{m}$)로 여과 후 하수중의 미생물에 의한 영향을 제거하기 위하여 고압멸균기(autoclaver)로 12$0^{\circ}C$에서 15분간 멸균한 하수(R2), 여과ㆍ멸균된 하수를 membrane filter로 여과한 해수와 1:1 (하수:해수)로 혼합한 시료수(R3) 그리고 R3에서 사용된 하수와 해수를 이용해 그 비를 1:2로 혼합한 시료수(R4)를 이용하였다. 4종류로 조제된 시험수를 이용한 통수실험 결과를 요약하면 다음과 같다. 통수실험에 의해 제거된 COD 양은 시료수에 하수의 함유량이 증가할수록 증가하였다. 암모니아질소의 경우 각 칼럼에서 580분 실험한 후 총 누적 제거양은 R1 90.1mg, R2 81.0mg, R3 27.6mg, R4 4.1mg이었다. R1과 R2에서 총 누적 제거 양이 해수가 1:1로 함유된 R3보다는 약 3배 높았고, 생하수와 해수가 1:2로 함유된 R4보다는 약 20배 높아 시료수에 하수의 함량이 높을수록 COD와 마찬가지로 암모니아질소가 잘 제거되는 것으로 판단되었다. 총인의 경우 각 칼럼에서 580분 실험한 후 제거된 총 누적 양은 R1 3.4mg, R2 4.2mg, R3 5.6mg, R4 2.0mg이었다. 평균 유입수 농도와 평균 유출수 농도로 구한 Pb의 평균 제거율은 R3와 R4에서 94.6%와 94.9%로 R1과 R2에서의 65.5%와 77.0%보다 약간 높았고, Cd의 평균 제거율도 R3와 R4에서 93.1%와 88.5%로 R1과 R2에서의 61.2%와 82.7%보다 약간 높았다. 이상과 같이 칼럼실험에서 중금속은 해수가 첨가된 시료에서 제거율이 높았다. 하지만 초기 20분간 흡착된 중금속의 양은 580분 동안 흡착된 총 양의 3~4%로 유사한 값을 나타내었다.

  • PDF