Feasibility Study of Applying EMMC Process to Recirculation Water Treatment System in High Density Seawater Aquaculture Farm through Laboratory Scale Reactor Operation (실험실규모 반응조 운전을 통한 고밀도 해산어 양식장 순환수 처리공정으로서 EMMC공정의 적용 가능성 연구)

  • Jeong Byung Gon;Kim Byung Hyo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.3
    • /
    • pp.116-121
    • /
    • 2004
  • Treatability tests were conducted to study the feasibility of EMMC process as a recycling-water treatment system in high density seawater aquaculture farm. To study the effect of organic and ammonia nitrogen loading rate on system performance, hydraulic retention time was reduced gradually from 12hr to 10min. The conclusions are can be summarized as follows. When the system HRT was reduced from 12hr to 2hr gradually, there was little noticeable change(reduction) in ammonia nitrogen removal efficiencies. However, removal efficiencies were decreased dramatically when the system was operated under the HRT of less than 2hr. In case of organics(COD), there was no dramatic change in removal efficiencies depending on HRT reduction. COD removal efficiencies were maintained successfully higher than 9% when the system was operated at tile HRT of 10 min. System performances depending on media packing ratio in the reactors were also evaluated. There were little differences in each reactor performances depending on media packing ratio in reactor when the reactors were operated under the HRT of longer than 1hr. However, differences in reactor performances were considerably evident when the reactors were operated under the HRT of shorter than 1hr. When comparing reactor performance among 25%, 50%,7 5% packed reactor, it can be judged that media packing ratio more than 50% plays no significant role in increasing reactor performance. For this reason, packing the media less than 50% is more reasonable way in view of economic. Such a tendency shown in COD removal efficiencies well agreed with the variation of ammonia-nitrogen removal efficiencies according to the media packing ratio in reactors at each HRT. Difference in effluent ammonia-nitrogen concentration between 50% media packing reactor and 75% media packing reactor was negligible. When comparing with the results of 25% packing reactor, difference was not so great.

  • PDF

Retrospect on Refractories in Water Treatment (기존 정수처리방법으로 제거가 어려운 유기물에 대한 실험적 연구)

  • 우달식;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.17-23
    • /
    • 1995
  • As a basic experiment to develope biological pretreatment proces~ in water treatment, the experiments on biodegradability and isothermal adsorption of activated carbon were performed on refractories such as humic acid, $NH_3-N$, phenol and ABS which caused the problems in drinking water treatment. Also, the treatabilities on humic acid were examined in the continuous flow type reactors. The removal efficiencies of humic acid, $NH_3-N$, phenol and ABS in the biodegradable experiments for 5 days were 20.1%, 73.4%, 91.7% and 97.5%, respectively. In the isothermal adsorption test of refractories on activated carbon to be used as a media in the continuous flow type reactors, ABS and phenol are adsorbed easily, but humic acid and $NH_3-N$ are difficult to be done. The removal efficiencies of humic acid in granular activated carbon(GAC) reactor were about 7-8% higher than in biological activated carbon(BAC) reactor. The removal efficiencies of humic acid in biological fluidized bed(BFB) reactor were about 30% in GAC media, but were almost zero in sea sand media.

  • PDF

Case Study: Operation of the Juam Constructed Wetland for Effluent from a Sewage Treatment Plant and Diffuse Pollution for Two Years (하수종말처리장 방류수와 비점오염원 처리를 위한 주암호 인공습지 2년 운영 사례)

  • Jung, Yong-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1031-1037
    • /
    • 2006
  • In order to improve water quality of the Juam Lake, a constructed wetland was implemented and operated for 2 years with the effluent of sewage treatment plant and diffuse pollutant discharged from agricultural area. During the summer season, average removal efficiencies for BOD and SS were 15.8% and 39.4%, respectively. Due to the mixed effect of vegetation, soil microbes and sediments, the higher nutrient removal efficiencies were obtained: average T-N and T-P removal efficiencies were 64.2% and 71.7%, respectively. The concentration of sediment was increased initially, and maintained constant throughout monitoring period. The highest nitrogen and phosphorus uptake were observed in Phragmites japonica. The nitrogen uptake was estimated as 0.235 DW mg/g while phosphorus uptake was estimated as 2.059 DW mg/g.

5-Bromo-Ph4-BTPhen Ligand for Selective Removal of Strontium and Cobalt From Water

  • Jang, Jiseon;Harwood, Laurence M.;Cowell, Joe;Afsar, Ashfaq;Lee, Dae Sung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2018.05a
    • /
    • pp.183-183
    • /
    • 2018
  • In this study, 5-bromo-2,9-bis(5,6-diphenyl-1,2,4-triazin-3-yl)-1,10-phenanthroline (5-bromo-Ph4-BTPhen) was synthesized and evaluated for its ability to remove major radionuclides ($Cs^+$, $Sr^{2+}$, and $Co^{2+}$). The synthesized ligand removed both $Sr^{2+}$ and $Co^{2+}$ from $1mg\;L^{-1}$ aqueous solutions with extraction efficiencies of up to 99% at neutral and alkaline pH. The $Sr^{2+}$ and $Co^{2+}$ removal efficiencies decreased as a consequence of the higher bonding strengths of competing metal ions to the N-donor atoms in the cavity of the ligand; competing divalent ions affected the $Sr^{2+}$ and $Co^{2+}$ removal efficiencies more than monovalent ions.

  • PDF

Decolorization of Acid Orange II from Aqueous Solutions using Loess (황토를 이용한 Acid Orange II의 색도제거)

  • Park, Jae Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.141-146
    • /
    • 2011
  • Loess, a natural clay, was evaluated as an adsorbent for the decolorization of Acid Orange II, an azo and reactive dye, from aqueous solution. Adsorption studies were performed at $30^{\circ}C$ and the effect of reaction time, loess dosage, initial concentration, loess particle size, pH, agitation rate were investigated to determine the optimum operation conditions. The removal efficiencies of color were measured to evaluate the effectiveness of loess. From this study, it was found that optimal reaction time was 10 min. Color removal efficiencies of Acid Orange II were increased as higher loess dosage, initial concentration and agitation rate. However, color removal efficiencies decreased when pH is high and loess particle becomes large. Adsorption of Acid Orange II fitted to the pseudo-second-order rate kinetics more than first-order rate kinetics. Langmuir and Freundlich adsorption isotherm constants and correlation coefficients were calculated and compared. It was concluded that the adsorption data of Acid Orange II onto loess fitted to the Freundlich model more than Langmuir model.

Treatment Characteristics of Paper-mill Wastewater Using Pure Oxygen Activated Sludge Process (순산소 활성오니 공정을 이용한 제지폐수의 처리특성)

  • Kim, Sung Soon;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.27-34
    • /
    • 1999
  • An experimental study on improvement of the paper-mill wastewater treatment using the pure oxygen activated sludge process was conducted. The effects of hydraulic retention time(HRT) and BOD loading on organic removal efficiency were investigated. The BOD removal efficiencies were above 90% under all examined HRTs except for HRT of 3 hours. The increase of HRT from 3 hours to 6 hours, and to 12 hours significantly improved BOD and COD removal efficiencies, respectively. However, additional increase of HRT did not affect organic removal efficiency. F/M ratio change at fixed HRT did not affect organic removal efficiency. However, F/M ratio investigated in this study(0.11~1.98kgBOD/kgMLVSS/day) was 5 times greater in maximum than that of conventional activated sludge process, which implies that pure oxygen activated sludge process can treat wastewater with high organic strength. Under the same HRT, the volumetric BOD loading change cause no effect on organic removal efficiency also.

  • PDF

Analysis on NOX Removal Efficiencies and Particle Growth Using Pulsed Corona Discharge Reactor (펄스 코로나 방전 반응기를 이용한 NOX 제거 효율 및 입자 성장 분석)

  • Park, Jung-Hwan;Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.155-161
    • /
    • 2001
  • In this study, we analyzed the $NO_X$ removal efficiency and particle size distribution by the pulsed corona discharge process and investigated the effect of several process variables. The NO removal efficiencies and the particle characteristics were measured and analyzed as the function of initial concentrations of NO, $H_2O$, and $NH_3$, applied voltage, pulse frequency and residence time. As the frequency of applied voltage increases, or as the applied voltage increases or as the residence time increases, the NO removal efficiency increases. The change of initial $NH_3$ and $H_2O$ concentrations do not affect the NO removal efficiency significantly. The particle concentration and size increases with the increases of initial NO concentration, residence time and applied voltage.

  • PDF

Continuous removal of heavy metals by coupling a microbial fuel cell and a microbial electrolytic cell

  • Xie, Guo R.;Choi, Chan S.;Lim, Bong S.;Chu, Shao X.
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.283-294
    • /
    • 2020
  • This work aims at studying the feasibility of continuous removal of mixed heavy metal ions from simulated zinc plating wastewaters by coupling a microbial fuel cell and a microbial electrolysis cell in batch and continuous modes. The discharging voltage of MFC increased initially from 0.4621 ± 0.0005 V to 0.4864 ± 0.0006 V as the initial concentration of Cr6+ increased from 10 ppm to 60 ppm. Almost complete removal of Cr6+ and low removal of Cu2+ occurred in MFC of the MFC-MEC-coupled system after 8 hours under the batch mode; removal efficiencies (REs) of Cr6+ and Cu2+ were 99.76% and 30.49%. After the same reaction time, REs of nickel and zinc ions were 55.15% and 76.21% in its MEC. Cu2+, Ni2+, and Zn2+ removal efficiencies of 54.98%, 30.63%, 55.04%, and 75.35% were achieved in the effluent within optimum HRT of 2 hours under the continuous mode. The incomplete removal of Cu2+, Ni2+ and Zn2+ ions in the effluent was due to the fact that the Cr6+ was almost completely consumed at the end of MFC reaction. After HRT of 12 hours, at the different sampling locations, Cr6+ and Cu2+ removal efficiencies in the cathodic chamber of MFC were 89.95% and 34.69%, respectively. 94.58%, 33.95%, 56.57%, and 75.76% were achieved for Cr6+, Cu2+, Ni2+ and Zn2+ in the cathodic chamber of MEC. It can be concluded that those metal ions can be removed completely by repeatedly passing high concentration of Cr6+ through the cathode chamber of MFC of the MFC-MEC-coupled system.

An Experiment on Particle Collection and Gas Removal in a 2-Stage Electrostatic Wet Scrubber (2단 정전식 세정집진기의 집진 및 가스제거 특성)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Son, Seung-Woo;Kim, Yoon-Shin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.745-752
    • /
    • 2006
  • DOS and NaCl aerosol particles were used to determine collection efficiencies of a 2-stage electrostatic wet scrubber with respect to particle size. The DOS and NaCl aerosols have geometric mean diameters of 0.1-3.0 urn, geometric standard deviations of $1.1{\sim}1.8$ and total number concentrations of $450{\sim}2,400\;particles/cm^3$. The tested operating variables for the electrostatic wet scrubber included air velocity and water injection rate. It was shown from the experimental results that particle collection efficiencies increased in the submicron particle size range when different polarities were applied on the water nozzle and corona wire, respectively. This increase in the collection efficiency is attributed to strong electrostatic attraction between the negative water droplets and positive submicron particles. The collection efficiencies also increased when water injection rate was increased or air velocity was decreased. Meanwhile, the pressure drop across the wet scrubber decreased by 90% compared with the existing mechanical wet scrubber. Finally, ammonia gas was used to determine gas removal efficiencies. It was observed that the gas removal efficiencies increased when the air velocity was decreased or the water injection rate was increased.

Removal of Volatile Organic Compounds by Photo-Catalytic Oxidation

  • Lee, Byeong-Kyu;Jung, Kwang-Ryun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.39-46
    • /
    • 2000
  • Volatile Organic Compounds (VOCs) are considered as the precursors of atmospheric ozone and photochemical smog formation. In particular, chemical plants have produced a lot of VOCs and thus they have been forced to reduce or remove air emissions from the on-site chemical facilities. For the effective removal of VOCs produced in the chemical plants, the authors employed a titanium oxide(TiO$_2$) mediated photo-catalytic oxidation method. The initiation methods employed in this study to produce oxygen radicals for th photo-catalytic oxidation of the VOCs were Ultra-Violet(UV), Non-Thermal Plasma(NTS), and a combination of Uv and NTP. This study focused on a comparison of the removal efficiencies of VOCs as a function of the initiation method such as NTP and/or UV techniques. Removal efficiency change of VOCs as was investigated as a function of the wavelength of the UV lamp(254, 302, and 365 nm) and the degree of TiO$_2$ coating (10 and 30%). In this study, it was identified that removal efficiencies if the VOCs under the normal air environment were much better than those under the nitrogen gas environment containing small amount of oxygen. Removal efficiency by NTP technique was much better than the UV or the combination of UV and NTP techniques. In a comparison if UV wavelengths employed, it was found that shorter wavelength showed better removal efficiency, compared with longer ones. When the removal efficiencies of VOCs were compared in terms of the degree of TiO$_2$ coating, the higher TiO$_2$coating showed better removal efficiency that the lower TiO$_2$ coating