• Title/Summary/Keyword: Removal Apparatus

Search Result 111, Processing Time 0.032 seconds

Effect of Membrane Material and Absorbent Type on $SO_2$ Removal Using Microporous Hollow-fiber Membrane G-L Contactors (다공성 중공사막 기액 접촉기틀 이용한 $SO_2$ 제거에서 막재질과 흡수제의 영향)

  • Song Hee-Ouel;Kim In-Won;Park Hyun-Hee;Lim Chun-Won;Jo Hang-Dae;Lee Hyung-Keun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.2 s.31
    • /
    • pp.14-21
    • /
    • 2006
  • An experimental apparatus for the removal of $SO_2$ gas using microporous hollow-fiber membrane G-L contactors was setup. Various performance experiments were carried out with commercial membrane modules and the membrane modules made by KIER. The $SO_2$ removal efficiency was outstanding. When the hollow-fiber membrane was used for the removal of $SO_2$, the selection of absorbers and additives, membrane material, operating conditions of membrane manufacture were significant variables to develop optimal G-L contactors. More experiment works will be done for the development of compact, cost-effective and better G-L contactors.

  • PDF

Characteristics of DOC Removal by Coagulation Process in the Water Treatment of Nakdong River (낙동강 수계에 대한 정수처리공정에서 응집공정의 DOC 제거 특성)

  • Hwang, Deok-Heung;Kim, Dong-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.66-73
    • /
    • 1999
  • This study was carried out to derive the removal characteristics of target materials(DOC and turbidity) during the coagulation process after the injection of coagulants(PACl and FeCl3). Used apparatus were a jar test and a pilot plant. A great portion of DOC among the total removed DOC was achieved at the slow mixing process among the coagulation process. The ranges of removed DOC and optimum pH for each coagulant were 0.45~1.47mg/l and 6.0~6.5 by PACl, and 0.97~2.61mg/l. and 5.0~5.5 by FeCl3, respectively. Both of coagulants showed little increase of DOC removal above coagulant dosage 20mg/l Molecular weight distribution(MWD) of removed DOC was measured by get filtration(GF) technique. The MWD variation by gel filtrationin(GF) for removed DOC in the coagulation process were as follows; for raw water, the percentages of each MWD for total area were < MW 6,500 25.5%, MW 6,500~66,000 67.1%, and > MW 66,000 7.4%. For the same coagulant dosage(12mg/l), the percentages of each MWD for total area by PACl were < MW 6,500 20.5%, MW 6,500~66,000 48.7%, and > MW 66,000 9.1%, and those of FeCl3 were MW 66,000 18.2%. For each coagulant, the removal percentage of MW 6,500~66,000 occurred a little, but at a part of

  • PDF

A Study on Inorganic Chemical Treatment Method of Animal Wastes Using by Electroflotation for Recycle (전해부상 장치를 이용한 축산폐수의 유기질비료와 용수 재활용에 관한 연구)

  • Sung Ki-chun;Kim Yong-Ryul;Kim Ki-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.6
    • /
    • pp.588-591
    • /
    • 2004
  • There is an increasing interest in the use of electrochemical methods for the animal waste treatment The technologies using the electrochemical method provide ideal tools for approaching industrial and animal wastes problems. Unlike other chemical treatments, the electrochemical systems do not make the volume of the secondary waste increase. The electrochemical methods can be operated with electrochemical apparatus and inorganic agent allow selective separation and recovery and even quieter than others. This study concerns design factors, electrode construction and wastewater treatment process of the electrochemical apparatus. The experiment of color, COD and BOD removal is much effective in using electrochemical method with ultrasonication and ozonation.

  • PDF

A Study on the Machining Characteristics of CVD-SiC (CVD-SiC 소재의 가공 특성에 관한 연구)

  • Park, Hwi-Keun;Lee, Won-Seok;Kang, Dong-Won;Park, In-Seung;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.40-46
    • /
    • 2017
  • A plasma gas control apparatus for semiconductor plasma etching processes securely holds a cathode for forming a plasma, confines the plasma during the plasma etching process, and discharges gas after etching. It is a key part of the etching process. With the advancement of semiconductor technology, there is increasing interest in parts for semiconductor manufacturing that directly affect wafers. Accordingly, in order to replace the plasma gas control device with a CVD-SiC material superior in mechanical properties to existing SiCs (Sintered-SiC, RB-SiC), a study on the grinding characteristics of CVD-SiC was carried out. It is confirmed that the optimal grinding condition was obtained when the result table feed rate was 2 m/min and the infeed depth was $5{\mu}m$.

Remediation of benzo[a]pyrene Contaminated Soil using Subcritical Water (아임계수를 이용한 토양 내 벤조[a]피렌 정화)

  • Shin, Moon-Su;Islam, Mohammad Nazrul;Jo, Young-Tae;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.13-17
    • /
    • 2014
  • Subcritical water acts like an organic solvent at elevated temperature in terms of its physicochemical properties. Taking into account this advantage, the remediation experiments of benzo[a]pyrene contaminated soil (8.45 mg/kg of initial concentration) were conducted using subcritical water extraction apparatus. The effect of operating factors on the removal efficiency was studied at the varying the conditions of the water temperature ranging $200{\sim}300^{\circ}C$, extraction time 30~90 min, and flow rate 0.3~2.0 mL/min. 12 g of benzo[a]pyrene contaminated soil was inserted into the extraction cell and placed into the reactor and then the subcritical water was driven through the cell. In this study, the removal efficiency of benzo[a]pyrene was increased from 55.1 to 98.1% when the temperature increased from 200 to $300^{\circ}C$. The removal efficiency was decreased from 97.0 to 77.0% when the flow rate increased from 0.3 to 2.0 mL/min, suggesting that the extraction is limited by intra-particle diffusion. The 30 min reaction time was determined as an effective treatment time at $250^{\circ}C$. Based on the results, the optimum condition for the remediation of benzo[a]pyrene contaminated soil was suggested to be $250^{\circ}C$, 30 min, and 0.3 mL/min.

A Study on the Adequate Treatment of Municipal Landfill Leachate -A Case Study of Nanjido Landfill Leachate- (도시폐기물 매립지 침출수의 적정처리에 관한 연구 -난지도 폐기물 매립지 침출수를 대상으로-)

  • 이병인
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.269-276
    • /
    • 1995
  • An experimental research was conducted in order to study the treatability of municipal landfill leachate using a combined physio-chemical and biological treatment. The leachate was obtained from Nanjido landfill site in Seoul. Several sets of bench-scale sequencing batch reactor(SBR) and physic-chemical reactors were used as experimental apparatus. This experiment lasted for about 2 years. The results are as follows: 1. The characteristics of Nanjido landfill leachate were pH 7.4~8.2, BOD 79~450mg/L, COD 998~1460mg/L, $NH_3-N$ 1380~3412mg/L, 7-P 2.6~7.0mg/L, color 890~1992 unit, and heavy metals are a very small amount. 2. Either physio-chemical or biological treatment of Landfill leachate alone did not work well. So for the adequate treatment of leachate, it was necessary to deal with the physio-chemical pretreatment before biological treatment. And it was found that both electrolysis and ozone treatment are better pretreatments of leachate than others. 3. In this study, landfill leachate was effectively processed by two step : first by electrolysis pretreatment, and secondly by SBR treatment. Thus, the study showed considerable substrate removal of raw leachate, even though the rate of COD removal depended on HRT.

  • PDF

A Study on the Adequate Treatment of Municipal Landfill Leachate -A Case Study of Nanjido Landfill Leachate- (도시폐기물 매립지 침출수의 적정처리에 관한 연구 -난지도 폐기물 매립지 침출수를 대상으로-)

  • Lee, Byeong-In
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.117-117
    • /
    • 1995
  • An experimental research was conducted in order to study the treatability of municipal landfill leachate using a combined physio-chemical and biological treatment. The leachate was obtained from Nanjido landfill site in Seoul. Several sets of bench-scale sequencing batch reactor(SBR) and physic-chemical reactors were used as experimental apparatus. This experiment lasted for about 2 years. The results are as follows: 1. The characteristics of Nanjido landfill leachate were pH 7.4~8.2, BOD 79~450mg/L, COD 998~1460mg/L, $NH_3-N$ 1380~3412mg/L, 7-P 2.6~7.0mg/L, color 890~1992 unit, and heavy metals are a very small amount. 2. Either physio-chemical or biological treatment of Landfill leachate alone did not work well. So for the adequate treatment of leachate, it was necessary to deal with the physio-chemical pretreatment before biological treatment. And it was found that both electrolysis and ozone treatment are better pretreatments of leachate than others. 3. In this study, landfill leachate was effectively processed by two step : first by electrolysis pretreatment, and secondly by SBR treatment. Thus, the study showed considerable substrate removal of raw leachate, even though the rate of COD removal depended on HRT.

Selective Removal of Cu in Ferrous Scrap by Chlorine gas (염소가스에 의한 철 스크랩 중 Cu의 선택적 제거)

  • Lee, So-Yeong;Sohn, Ho-Sang
    • Resources Recycling
    • /
    • v.27 no.5
    • /
    • pp.54-60
    • /
    • 2018
  • The quality of steel produced from scrap can be adversely affected because of the buildup of tramp elements in recycled scrap. The tramp element of greatest concern is copper because of its effect on steel quality, even in small percentage quantities. In this study, possibility of removal of copper from ferrous scrap by using $Cl_2$ gas is experimentally examined in a small size experimental apparatus. Synthetic ferrous scraps containing copper were reacted with $Cl_2$ gas in various atmosphere. The copper was chloridized and evaporated, whereas iron was oxidized and was not reacted with Cl2 and oxygen mixture gas.

Effect of Temperature on Treatment of Nitrogen and Phosphorus of Pig Wastewater in Bench Scale Reactor (실험실 수준의 반응조 온도가 양돈폐수중 질소, 인의 처리에 미치는 영향)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 1995
  • This study was performed to evaluate the effect of temperature on operating parameters for reactor in pig wastewater treatment using sequencing batch reactor method which is one of the biological treatment methods. Study was accomplished by experimental apparatus of bench scale, and the degradation rate coefficient and temperature correction factor were derived. The followings are the conclusions that were derived from this study. 1. In the characteristics of pig wastewater, concentrations of TKN and T-P were very high as 590 mg/l and 40 mg/l, respectively. 2. Removal efficiency of BOD and $COD_{Mn}$ as organic compound indicators were the highest mark as 97% at 25$\circ$C. 3. When temperature was incresed from 10$\circ$C to 25$\circ$C, removal efficiencies of TKN and T-P were proportionally increased. Especially, the former was greatly effected by temperature of reactor. 4. In experiment of bench scale, the degradation rate coefficients were increased as temperature increased, but decreased at the temperature range of 25~35$\circ$C. Temperature adjustment coefficients for $COD_{Mn}$, BOD, TKN and T-P were 1.1460, 1.1356, 1.1140 and 1.0565, respectively.

  • PDF

Characteristics of the molar surface after removal of cervical enamel projections: comparison of three different rotating instruments

  • Ko, Min-Jeong;Cho, Chan-Myung;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.107-115
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate and compare tooth surface characteristics in extracted human molars after cervical enamel projections (CEPs) were removed with the use of three rotating instruments. Methods: We classified 60 extracted molars due to periodontal lesion with CEPs into grade I, II, or III, according to the Masters and Hoskins' criteria. Each group contained 20 specimens. Three rotating instruments were used to remove the CEPs: a piezoelectric ultrasonic scaler, a periodontal bur, and a diamond bur. Tooth surface characteristics before and after removal of the projections were then evaluated with scanning electron microscopy (SEM). We analyzed the characteristics of the tooth surfaces with respect to roughness and whether the enamel projections had been completely removed. Results: In SEM images, surfaces treated with the diamond bur were smoothest, but this instrument caused considerable harm to tooth structures near the CEPs. The piezoelectric ultrasonic scaler group produced the roughest surface but caused less harm to the tooth structure near the furcation. In general, the surfaces treated with the periodontal bur were smoother than those treated with the ultrasonic scaler, and the periodontal bur did not invade adjacent tooth structures. Conclusions: For removal of grade II CEPs, the most effective instrument was the diamond bur. However, in removing grade III projections, the diamond bur can destroy both adjacent tooth structures and the periodontal apparatus. In such cases, careful use of the periodontal bur may be an appropriate substitute.