• Title/Summary/Keyword: Removal Apparatus

검색결과 111건 처리시간 0.018초

저장고 내의 에틸렌 제거가 배 과실의 품질에 미치는 영향 (Effect of Ethylene Removal on Fruit Quality of Oriental Pear during Storage)

  • 김호철;배강순;배종향;전경수;홍종욱
    • 생물환경조절학회지
    • /
    • 제15권1호
    • /
    • pp.78-83
    • /
    • 2006
  • The objective of this study was to examine effect of ethylene removal apparatus on fruit quality of 'Niitaka' pear (Pyrus pyrifolia) in case of a double storage of apples and pears in a storage room. Ethylene and carbon dioxide concentration were efficiently decreased by the ethylene removal apparatus. Fruit weight loss was high at double storage of apples and pears (DAP) in a storage room compared with storage of pears. Fruit core browning was $5{\sim}22.5%$ at the fruits in DAP, but as setting ethylene removal apparatus it was not occurred till 90 days after storage. Soluble solids content and fruit peel hardness were not different among the treatments. Accordingly, a double storage of apples and pears in a storage room is possible as setting ethylene removal apparatus.

BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거 (Nutrient Removal in an Advanced Treatment Process using BIO-CLOD)

  • 박완철;이미애;성일화
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

중탄산나트륨 건식공정에서 반응제 혼합 장치 및 백필터 분배장치에 의한 산성가스 제거 영향 (Removal Effect of Acid Gases by Reactant Mixer and Distributor of Bag Filter in Dry Scrubbing with NaHCO3)

  • 이영만;곽연호;배우근;권기욱
    • 한국대기환경학회지
    • /
    • 제25권5호
    • /
    • pp.402-409
    • /
    • 2009
  • Sodium bicarbonate ($NaHCO_3$) was used as a reactant for the removal of acid gases from a waste incinerator. The removal efficiencies of HCl and $SO_x$ were tested with a reactant mixing apparatus and a distributor installed at the bag filter inlet. It was shown that the stoichiometric ratio of $NaHCO_3$ to the acid gases which allows a removal of over 90% for both HCl and $SO_2$ was about 1.2. When a reactant mixing apparatus was installed on the duct, the removal efficiencies of HCl and $SO_2$ at the end of the duct were increased by approximately 1.5 and 3 times respectively, compared to when the apparatus was not installed. At the end of the bag filter, the removal efficiencies of the both were as high as 98% with a stoichiometric ratio of 1.35. Installing a reactant mixing apparatus on the duct and a distributor at the entrance of the bag filter and using $NaHCO_3$ as a reactant helped overcome the problem of low removal efficiencies of acid gases by dry scrubbing.

생물활성탄을 이용한 절삭유로 오염된 지하수의 처리특성과 미생물군집구조 해석 (Treatment Performance and Microbial Community Structure in BAC-process Treating Contaminated Groundwater by Water-soluble Cutting Oil)

  • 임병란;배시애;임호주;조창호
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.71-76
    • /
    • 2006
  • Treatment performance and microbial community structure were investigated in water-soluble cutting oil treatment process using biological activated carbon. DOC removal in BACI column at $15^{\circ}C$ was higher than at $25^{\circ}C$, but those of BAC3 column after 60days was high at$25^{\circ}C$. Also, quinone content of first-step reactors at $25^{\circ}C$ and $15^{\circ}C$ was much the same, but those of the third-step reactor at $25^{\circ}C$ was higher than at $15^{\circ}C$. The dominant type of two apparatus was ubquinone (UQ)-l 0 followed by UQ-8. Menaquinones were detected from $25^{\circ}C$ apparatus and effluent. This suggested that DOC removal at $25^{\circ}C$ was advanced degradation by attached microorganisms on the activated carbon surface. The DOC removal in long-term activated carbon apparatus increased with going in BAC3 column. This indicated the influent of POC was a result of DOC removal efficiency decrease. Integrated DOC removal from start point in experiment to break point and quinone content were showed a tendency of increasing with going last-step activated carbon apparatus. Therefore, the biological activated carbon apparatus used by this study was effective treatment process in contaminated groundwater by water-soluble cutting oil.

영구자석을 이용한 복수기 집수정 내부 자성이물질 제거장치 개발 (Development of an Apparatus for Removing Magnetic Sludge by Permanent Magnets Set up in the Condenser of the Power Plant)

  • 배준호;김문생;황범철;김철
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.938-948
    • /
    • 2009
  • In this paper, permanent magnets were used to remove magnetic sludge in the condenser of the power plant. To obtain the flow characteristics and magnetic information that are needed for determining a proper design of the magnetics sludge removal apparatus, numerical simulations were performed through the use of two commercial codes, ANSYS Workbench-Emag and CFX. Experiments were also performed on various kinds and sizes of magnets to obtain the magnetic information through a gauss meter. By analyzing the results of simulations and experiments, the minimum magnetic force that is able to remove the any size of the magnetic sludge in the condenser was calculated, and the design of the removal apparatus was confirmed. The test model which was confirmed by simulations and experiments was made. After testing, the test results were compared with those of numerical simulations and have good agreements.

나선형패들이 장착된 토양전기분해장치를 이용한 중금속 오염토양 정화에 관한 연구 (A Study on Remediation of Heavy Metal Contaminated Soil using a Soil Electrolysis Apparatus with Spiral Paddle)

  • 이준희;최영익;정진희
    • 한국환경과학회지
    • /
    • 제26권6호
    • /
    • pp.797-802
    • /
    • 2017
  • This study aimed to remove organic matter and heavy metals that could affect the recycling of soils contaminated by heavy metals, by means of electrolysis, carried out simultaneously with the leaching of the soil. To ensure better experimental equipment, a soil electrolysis apparatus, equipped with spiral paddles, was used to agitate the heavy-metal-contaminated soil effectively. The heavy-metal-contaminated soil was electrolyzed by varying the voltage to 5 V(Condition 1), 15 V(Condition 2), and 20 V(Condition 3), under the optimal operating conditions of the electrolysis apparatus, as determined through previous studies. The results showed that the pH of the electrolyte solution and the heavy-metal-contaminated soil, after electrolysis, tended to decrease with an increase in voltage. The highest removal efficiencies of TOC and $COD_{Cr}$ were 18.8% and 29.1%, 38.8% and 4.2%, and 33.3% and 50.0%, under conditions 1, 2 and 3, respectively. Heavy metals such as Cd and As were not detected in this experiment. The removal efficiencies of Cu, Pb and Cr were 4.7%, 8.3% and 2.1%, respectively, under Condition 1, while they were 42.9%, 15.2% and 22.1%, respectively, under Condition 2, and 4.7%, 23.0%, and 24.9%, respectively, under Condition 3. These results suggest that varying the voltage with the soil electrolysis apparatus for removing contaminants for the recycling of heavy-metal-contaminated soil allows the selective removal of contaminants. Therefore, the results of this study can be valuable as basic data for future studies on soil remediation.

자연정화공법에 의한 소형 하수처리장치 개발을 위한 최적 깊이 및 호기.혐기 비율 (Optimum Depth and Volume Ratio of Aerobic to Anaerobic Bed for Development of Small-Scale Sewage Treatment Apparatus by Natural Purification Method)

  • 서동철;박미령;곽내운;황하나;이홍재;조주식;허종수
    • 한국환경농학회지
    • /
    • 제25권1호
    • /
    • pp.14-24
    • /
    • 2006
  • 자연정화공법에 의한 농촌 전원 독립가구 하수처리장치의 적정 설치방법을 결정하기 위하여 호기성조와 혐기성조로 구성된 소형 하수처리장치를 설계 및 시공하였다. 소형 하수처리장치에서 여재 깊이에 따른 수처리 효율을 조사한 결과 호기성조와 혐기성조 모두 여재의 깊이가 깊어질수록 수처리 효율이 증가함으로 여재의 깊이를 90 cm이상으로 하는 것이 좋을 것으로 판단된다. 소형 하수처리장치의 최적 깊이인 90 cm하에서 호기성조 대 혐기성조 비율에 따른 수처리 효율을 조사한 결과 모든 여재에서 1 : 2 및 1 : 3의 호기 혐기 비율이 1 : 1에 비해 약간 높은 경향이었다. 따라서 소형 하수처리장치에서의 최적조건은 여재의 깊이는 90 cm이었고, 호기 혐기 비율은 1 : 2의 비율이었으며, 최적 여재는 왕사와 쇄석이었으며, 최적조건하에서 수처리효율은 BOD가 $97{\sim}99%$, COD가 $87{\sim}97%$, SS가 $88{\sim}99%$, T-N이 $57{\sim}68%$ 및 T-P가 $96{\sim}99%$이었다. 따라서 이러한 조건을 자연정화공법을 이용한 하수처리장치에 적용하면 하수처리장치의 부지면적을 최대한 줄이면서 높은 하수처리효율을 유지할 수 있을 것으로 판단된다.

자외선.오존 살균소독장치의 유체시뮬레이션 및 대장균 제거 특성 (The Hydraulic simulation and removal characteristics of Escherichia Coli for Ultraviolet rays.Ozone sterilization apparatus)

  • 황인아;이현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.169-172
    • /
    • 2005
  • The simulation of Hydraulic pressure distribution of discharge tube with globular beads and the removal characteristic of Escherichia coli by the discharge tube with globular beads were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the passing amount of test water in discharge tube is increased, the removal ratio of Escherichia coli was increased because passing numbers of electric field section is increased.

  • PDF

시설하우스 폐양액 주입방법 및 여재 특성에 따른 인공습지에서 수질오염물질의 처리효율 (Treatment Efficiency of Pollutants in Constructed Wetlands under Different Hydroponic Wastewater Injection Methods and Characteristic of Filter Media)

  • 서동철;박종환;천영석;박성규;김아름;이원규;이상원;이성태;조주식;허종수
    • 한국환경농학회지
    • /
    • 제29권2호
    • /
    • pp.146-151
    • /
    • 2010
  • In order to improve T-N and T-P removal in HF (horizontal flow)-HF hybrid constructed wetlands by natural purification method for treating the hydroponic wastewater in greenhouses, the efficiency of water treatment as affected by the injection method of hydroponic wastewater, the addition of special filter media, the particle size of filter media, and the injection ratio of hydroponic wastewater in $1^{st}$ HF and $2^{nd}$ HF beds were investigated in small-scale HF-HF hydroponic wastewater treatment apparatus. Removal rate of T-P in the water in HF-HF hydroponic wastewater treatment apparatus with calcite as affected by addition method of special filter media was higher than that in HF-HF hydroponic wastewater treatment apparatus with other filter media. Removal rate of BOD, COD, SS, T-N and T-P in the water in mixed filter media with calcite were 86, 84, 87, 50 and 97%, respectively. Removals of pollutants except for T-P in the water were slightly different. Therefore, it should be considered that the removal rate of T-P was good for calcite in HF-HF hydroponic wastewater treatment apparatus. To improve T-N and T-P removal, the optimum particle size of filter media was 1.2 mm, and the optimum injection ratio ($1^{st}$ HF bed : $2^{nd}$ HF bed) of hydroponic wastewater was 60:40.

자연정화공법에 의한 농촌 전원 독립가구 하수처리장치 개발 (Development of Sewage Treatment Apparatus for Detached House in Agricultural Village by Natural Purification Method)

  • 서동철;박미령;김형준;조인재;이홍재;성성진;조주식;허종수
    • 한국환경농학회지
    • /
    • 제25권3호
    • /
    • pp.202-210
    • /
    • 2006
  • 자연정화공법에 의한 농촌 전원 독립가구 하수처리공법 개발을 위하여 호기성조와 혐기성조가 분리된 소형 하수처리 장치에서 혐기성조 위에 호기성조를 포갠 일체형으로 공법을 개선한 소형 하수처리장치를 설계 및 시공하여 하수처리공법별, 하수 부하량 및 하수 주입방법에 따른 수처리 효율을 조사하였다. 소형 하수처리장치의 최적공법은 호기-무산소-혐기조건이었으며, 최적여재는 쇄석이었고, 최적 하수 부하량은 $1,200L/m^3{\cdot}day$이었다. 이러한 조건에서 농촌 전윈 독립가구에서 간헐적으로 배출되는 하수에 대한 대응성을 조사하기 위해 하수 주입방법에 따른 하수처리효율을 조사한 결과 농촌 전원 독립가구 하수처리공법으로 개발된 호기-무산소-혐기조건인 소형 하수처리장치는 실제 농촌 전원독립가구에서 간헐적으로 발생되는 하수에 그대로 적용하더라도 현행 방류수 수질기준인 BOD 20 mg/L, COD 40 mg/L, SS 20 mg/L, T-N 60 mg/L 및 T-P 8 mg/L을 만족할 뿐만 아니라, 방류수 수질기준이 앞으로 BOD 10 mg/L, T-N 20 mg/L 및 T-P 2 mg/L로 강화되더라도 안정적으로 처리될 수 있을 것으로 판단된다. 이상의 결과에서 농촌 전원 독립가구 하수처리공법으로 개발한 호기-무산소-혐기조건인 소형 하수처리장치는 BOD 99%, COD 95%, SS 99%, T-N 83% 및 T-P 96%초 질소 처리효율을 호기성조와 혐기성조가 분리된 소형 하수처리장치에 비해 17%정도 향상시켰으며, 모든 조가 일체형이므로 부지면적을 최소화할 수 있다. 따라서 본 공법은 자연정화공법의 단점을 보완할 수 있으므로 농촌 전원 독립가구에 적합할 것으로 사료된다.