• 제목/요약/키워드: Remote Calibration

검색결과 288건 처리시간 0.023초

로봇의 위치 정밀도 측정을 위한 LTS의 설계 및 제작 (Design and Manufacture of Laser Tracking System for Measuring Position Accuracy of Robots)

  • 황성호;이호길;최경락;김진영
    • 제어로봇시스템학회논문지
    • /
    • 제7권6호
    • /
    • pp.518-522
    • /
    • 2001
  • The main problem of the calibration of robots is to measure the position and orientation of a robot end effector. The calibration methods can be used as tool to improve the accuracy of robots without change of the arm or control architecture or robots. But such calibration methods require accurate measurements. Dynamic measurement of position and orientation provides a solution for this problem and improves dynamic accuracy by dynamic calibration of robots. This paper describes the development of the laser tracking system capable of determining the static and dynamic performance of industrial robots. The structure and systems components are presented and basic experimental results are included to demonstrated the instrument performance. The system can be applied to the remote controlled mobile robots as well s the calibration of robots.

  • PDF

Calibration Slope Adjustment for De-Striping KOMPSAT-1 EOC Images

  • Kang, C.H.;Park, D.J.;Ahn, S.I.;Koo, I.H.;Hyun, D.H.;Yang, H.M.;Kim, D.S.;Keum, J.H.;Choi, H.J.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1406-1408
    • /
    • 2003
  • KOMPSAT-1 (KOrea Multi-Purpose SATellite ? 1) EOC (Electro Optic Camera) raw images are radiometrically corrected on ground based on the characteristics of EOC. They consist of each CCD (Charge?Coupled Device) pixel’s calibration slope which was measured on ground, electrical gains which are applied to amplify for increasing output pixel counts. Currently, radio-metrically corrected EOC images with calibration slope have still shown defective features by residual stripes. So, it should be compensated by adjusting the calibration slope. In this paper, the adjustment of current calibration slope for de-striping EOC images is addressed and test results are shown.

  • PDF

KOMPSAT-3와 Landsat-8의 시계열 융합활용을 위한 교차검보정 (Radiometric Cross Calibration of KOMPSAT-3 and Lnadsat-8 for Time-Series Harmonization)

  • 안호용;나상일;박찬원;홍석영;소규호;이경도
    • 대한원격탐사학회지
    • /
    • 제36권6_2호
    • /
    • pp.1523-1535
    • /
    • 2020
  • 원격탐사를 이용한 작황정보 생산은 작물의 생물계절을 이용하여 작물 분류, 생육 모니터링, 생산량 추정 분석이 선행되어야 한다. 생물계절에 추정을 위한 시계열 영상 자료가 필요하지만 KOMPSAT(Korea Multi-Purpose Satellite)만으로 획득하는 것은 물리적 제한이 있으므로 타 지구관측위성과의 융합 활용이 필요하다. 위성자료의 융합 활용을 위해서는 각 위성이 가지는 고유의 방사학적 센서 특성 차이를 극복해야 한다. 본 연구는 위성자료의 융·복합 활용을 위한 첫 단계로서 KOMPSAT-3와 Landsat-8 위성의 교차검보정을 수행하였다. Libya-4 PICS(Pseudo Invariant Calibration Sites)에서 2년간 수집된 위성자료에 대해 초분광위성을 이용하여 산정된 SBAF(Spectral Band Adjustment Factor)를 적용하여 대기상단 반사도를 비교하였다. 교차검보정 결과 KOMPSAT-3와 Landsat-8 위성은 Blue, Green, Red 밴드에서 약 4%, NIR밴드에서 6%의 반사율 차이를 보였다. 온보드 켈리브레이터가 없는 KOMPSAT-3는 Ladnsat-8에 비해 Radiometric Stability가 낮은 것으로 나타났다. 향후 교차검보정의 정확도를 높이기 위해 BRDF(Bidirectional reflectance distribution function) 보정 및 지형보정을 통하여 정규화 된 반사율 자료를 생산하기 위한 노력이 필요하다.

농림위성 산림분야 식생지수 검보정 사이트 설계 (Design of Calibration and Validation Area for Forestry Vegetation Index from CAS500-4)

  • 임중빈;차성은;원명수;김준;박주한;류영렬;이우균
    • 대한원격탐사학회지
    • /
    • 제38권3호
    • /
    • pp.311-326
    • /
    • 2022
  • 우리나라 산림의 효율적인 관리와 산림 모니터링을 위해 산림청은 농림위성을 개발 중이며 2025년 발사 예정이다. 농림위성을 효율적으로 활용하기 위해 산림청 국립산림과학원은 36종의 농림위성 산림분야 활용산출물 개발을 진행 중이다. 원격탐사 기법을 활용하여 도출된 산출물들은 지상검증이 요구되며 해당 산출물들에 대한 품질 모니터링 결과를 지속적으로 보고해야 한다. 국내 최초로 산림분야 활용 위성이 개발되는 상황이라 국내에는 공식적인 산림분야 활용 산출물 검보정 사이트가 부재하다. 이에 저자들은 국제기준에 맞춰 농림위성 산림분야 활용산출물 검보정을 위한 검보정 사이트를 설계하였다. 또한 전국적으로 검보정 사이트를 설치하기 위해 적정 센서를 선택하여 해당 센서의 활용 가능성을 평가하였다. 평가 결과 지상 관측데이터와 Sentinel-2 영상과의 산림 산출물에 대한 오차가 ±5% 이내로 관측되어 해당 센서를 활용하여 전국적으로 확장이 가능함을 확인하였다.

원격 유성 분광 관측 시스템 구축과 관측 사례 연구 (Establishment of Remote Meteor Spectroscopic Observation System and Observation Case Study)

  • 최동열
    • 한국지구과학회지
    • /
    • 제43권1호
    • /
    • pp.1-22
    • /
    • 2022
  • 운장산 천문대에 있는 원격 유성 분광 관측 시스템의 설치 및 운영에 대해 자세히 설명한다. 총 3대의 고감도 CCD 카메라가 설치되었으며 2대의 CCD 카메라에는 렌즈 전면에 회절 격자를 부착하였다. 시스템은 2019년 11월에 설치되었고, f/1.2 렌즈와 결합된 고감도의 "Watec-902H2" 카메라가 사용되었다. 스펙트럼 관찰을 위한 회절 격자는 500 l/mm이 사용되었다. 관측은 2019년 11월부터 2020년 6월까지 진행되었다. 유성 탐지 및 후속 분석을 위해 SonotaCo UFO 소프트웨어 제품군을 사용했으며, 유성 스펙트럼을 분석하기 위해서는 RSpec 소프트웨어를 사용하였다. 관측영상을 활용하기 위해 Astronomical Calibration과 Photometric Calibration을 수행하였고, 최종적으로 유성의 화학 성분을 분석하였다. 우리는 유성 분광 관측 시스템의 설치와 설정/운영 경험을 설명하고 첫 번째 관측 결과를 제시한다. 또한 결과를 통해 유성의 기원에 대한 간략한 정보를 제공하고자 한다.

IMPERVIOUS SURFACE ESTIMATION USING REMOTE SENSING IMAGES AND TREE REGRESSIOIN

  • Kim, Soo-Young;Kim, Jong-Hong;Heo, Joon;Heo, Jun-Haeng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.239-242
    • /
    • 2006
  • Impervious surface is an important index for the estimation of urbanization and environmental change. In addition, impervious surface has an influence on the parameters of rainfall-runoff model during rainy season. The increase of impervious surface causes peak discharge increasing and fast concentration time in urban area. Accordingly, impervious surface estimation is an important factor of urban rainfall-runoff model development and calibration. In this study, impervious surface estimation is performed by using remote sensing images such as landsat-7 ETM+ and high resolution satellite image and regression tree algorithm based on case study area ? Jungnang-cheon basin in Korea.

  • PDF

능동적 원격감시를 위한 스테레오 카메라 시스템의 개발 (Development of the Stereo Camera System for Active Remote Monitoring)

  • 박강;조대희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.437-441
    • /
    • 1997
  • In the conventional remote monitoring system, a user in front of a computer monitor can acquire only 2 dimensional visual information in a passive way. Thus, even thoght the user finds an interesting object from the video image, helshe can hardly acquire additional information on the object such as name. 311 shape, etc. In this paper, an active monitoring system that shows additional information on the selected object is proposed. The active remote monitoring system can calculate the 3D position of the object that is selected in the video images. Then, using the 3D position of the object, other information on the object can be retrieved from the database and shown on the screen. To calculate the 3D position of the object, 2 CCD cameras that can be tilted and panned using 3 stepping motors are used. The algorithm of 3D position calculation and the result of experiments are explained.

  • PDF

사용자 캘리브레이션이 필요 없는 시선 추적 모델 연구 (User-Calibration Free Gaze Tracking System Model)

  • 고은지;김명준
    • 한국정보통신학회논문지
    • /
    • 제18권5호
    • /
    • pp.1096-1102
    • /
    • 2014
  • 적외선 조명을 이용한 간접시선추적 시스템에서는 촬영된 이미지에서 동공에 반사된 조명의 위치에 대한 캘리브레이션이 필수적이다. 하지만 안구의 크기나 머리의 위치에 따라 달라질 수도 있는 변수가 캘리브레이션 과정에서 정의된 상수로 계산에 포함되어 있어 오차를 감소시키는데 한계가 있다. 본 논문은 적외선 조명을 사용하면서도, 사용자 캘리브레이션 과정을 생략할 수 있는 방법을 연구한다. 반사각에 의한 글린트(glint)위치 차이에 영향을 받지 않게 하면서, 시스템의 모델과 시선 계산은 단순하게 하여 실시간 연산이 가능하도록 하는 것이 목표이다.

A Noise Re-radiation Calibration Technique in Interferometric Synthetic Aperture Radiometer for Sub-Y-type Array at Ka-Band

  • Seo Seungwon;Kim Sunghyun;Choi Junho;Park Hyuk;Lee Hojin;Kim Yonghoon;Kang Gumsil
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.577-580
    • /
    • 2004
  • To overcome with large size noise source distribution network design difficulty in interferometric radiometer system, especially for sub-Y-type array, a new on-board calibration technique using noise re-radiation is proposed in this paper. The suggested calibration technique is using noise re-radiation effect of center antenna after noise source injection from matched load. This approach is especially proper to sub-Y-type array interferometric synthetic aperture radiometer in mm-wave frequency band. Compared with noise injection network of a conventional synthetic aperture radiometer, the system mass, volume, and hardware complexity is reduced and cost-effective. Only one internal noise source, matched load, is used for injection using noise re-radiation technique a small set of sub-Y receiver channels is calibrated. Detailed calibration scenario is discussed and simulation results about noise re­radiation effect are presented.

  • PDF

ERROR PROPAGATION ANALYSIS FOR IN-ORBIT GOCI RADIOMETRIC CALIBRATION

  • Kang, Gm-Sil;Youn, Heong-Sik
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.92-95
    • /
    • 2008
  • The Geostationary Ocean Color Imager (GOCI) is under development to provide a monitoring of ocean-color around the Korean Peninsula from geostationary platforms. It is planned to be loaded on Communication, Ocean, and Meteorological Satellite (COMS) of Korea. The GOCI has been designed to provide multi-spectral data to detect, monitor, quantify, and predict short term changes of coastal ocean environment for marine science research and application purpose. The target area of GOCI observation covers sea area around the Korean Peninsula. Based on the nonlinear radiometric model, the GOCI calibration method has been derived. The radiometric model of GOCI has been validated through radiometric ground test. From this ground test result, GOCI radiometric model has been changed from second order to third order. In this paper, the radiometric test performed to evaluate the radiometric nonlinearity is described and the GOCI radiometric error propagation is analyzed. The GOCI radiometric calibration is based on onboard calibration devices; solar diffuser, DAMD (Diffuser Aging Monitoring Device). The radiometric model error due to the dark current nonlinearity is considered as a systematic error. Also the offset correction error due to gain/offset instability is considered. The radiometric accuracy depends mainly on the ground characterization accuracies of solar diffuser and DAMD.

  • PDF