Variations in Multi-family House Prices Following Remodeling Work

  • Kim, Jae-sung;Cho, Kyuman
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.689-690
    • /
    • 2015
  • The remodeling of multi-family houses (MFH) has emerged as a significant issue in the construction industry. Many decision makers struggle with the decision to remodel because of insufficient information including standards or methods for projecting the price of their structure after remodeling. In this context, this research analyzed the change in price of MFHs after remodeling. To achieve this research goal, (i) the price data from 14 groups (i.e., MFH renovation cases and equivalent MFH cases without remodeling) were collected, and (ii) the trend of price variation among each group was analyzed. Finally, this research suggests price variations of each group in terms of three different time points (i.e., before remodeling, after remodeling, and the present), which shows the effects of remodeling on the price of MFHs. This research offers a framework for the development of a model that will predict the price of an MFH after remodeling.

  • PDF

A Study of the Remodeling Techniques for Old Apartment Blocks (아파트단지 내부의 리모델링 수법에 관한 연구)

  • 김한수;김재홍
    • Journal of the Korean housing association
    • /
    • v.13 no.6
    • /
    • pp.121-131
    • /
    • 2002
  • The rebuilding method for old apartment housing blocks has merits of providing new buildings and larger private living spaces. However, it causes many serious urban problems, such as shortage of infrastructure capacity, traffic congestion, reduction of building life, and deterioration of open space quality. Nowadays, remodeling is accepted as a way of overcoming such negative effects of the rebuilding method. This study focuses on the various techniques of remodeling. The results of this research are as follows; First, old apartment blocks provide poor level of service in general, so they have problems of bad accessibility, deterioration of facilities, and degraded landscape. In many cases, there is a hindrance from walking freely and security problem due to illegal privatization of public spaces. Second, various remodeling techniques are required to meet residents' different needs. The residents of apartment housing value private space above public space, and show low level of willingness to pay cost for remodeling. Third, based on these findings, some remodeling techniques are suggested - integration of a space to another, expansion of spaces, connection of spaces, reuses of roofs and walls, relocation and renovation of paths between buildings, and so on.

Physical Environment Change and Occupancy Evaluation on Green-Remodeled University Dormitory (그린리모델링 기숙사의 물리적환경 변화와 거주자평가)

  • Choi, Yoon-Jung;Lee, Ho-Yeon;Lee, Hyun-Jung;Kim, Won-bae
    • Journal of the Korean housing association
    • /
    • v.28 no.1
    • /
    • pp.37-44
    • /
    • 2017
  • This study focuses on the university dormitory remodeled toward energy efficiency. The study has its purpose on deriving the aspects to be concerned for later green remodeling and enhancing the effects of green remodeling, by analyzing the changes of physical environment, changes of energy consumption amount, and needs of the residents. For this purpose, the study went through the review of project report from government office for green remodeling, field investigation of remodeling elements, and the occupancy evaluation by Focus Group Interview. FGI means interviewing small group of the residents who lived in the subjected dormitories both before and after the remodeling. As results, the elements of green remodeling in targeted dormitories were inner wall insulation, top-floor ceiling insulation, replacement of windows, installment of automatic entrance door and making transfer space connected the entrance door. As the parts of equipment system, EHP high-efficiency cooler, highly efficient radiator, upgraded LED lightings with covers, and automatic control system (only one building) were installed. Energy consumption was declined, and the satisfaction of residents was increased after the green remodeling. However, the aspects which were not improved or unsatisfying also have been detected. Therefore, the study states the suggestions each for the administrators, designers and planners, and residents to concern for enhancing the effects of green remodeling or construction of new dormitories.

The Effects of the Improvement of the Food Service Environment on Patients′ Satisfaction with the Hospital Food Service - Focused on Case Studies - (급식환경 개선이 환자식 만족도에 미치는 영향 -사례 연구 중심으로 -)

  • 이승림;장유경
    • Korean Journal of Community Nutrition
    • /
    • v.8 no.4
    • /
    • pp.566-573
    • /
    • 2003
  • The purpose of this study was to assess how the changes in the food services environment on patients satisfaction with the hospital food service. Statistical data analyses were completed using the SPSS 11.0 program. The results can be summarized as follows: The flow line and environment of the food services in the hospital were improved through remodeling, which included the replacement of all cooking utensils, ventilation facilities and material storages, the purchase of a combi steamer, and the change of meal carts and trays. After the remodeling, the hospital food service was improved so that it provided spoons at each meal, diversified the menu utilizing the combi steamer, served event meals three times a week as well as water boiled with burned rice in the morning twice a week. In addition, various types of tableware were used in the table settings to produce attractive visual effects. Among the 10 items included on the patient satisfaction questionnaire, ″satisfaction with offered menus″ (p < 0.01) showed significantly higher scores before the remodeling. ″cooking/seasoning of food″, ″amount of meals″ and ″taste of meals″ were not statistically significant, but showed increased satisfaction after the remodeling. However ″temperature of food″, ″cleanliness of clothes and features″ and ″satisfaction with meal times″ were not statistically significant, but showed decreased satisfaction after the remodeling. (Korean J Community Nutrition 8(4) : 566-573, 2003)

Analysis on the Energy and GHG Emissions Reduction Effect of Old Public Health Centers through Green-remodeling (노후 보건소의 그린리모델링을 통한 에너지 및 탄소배출 저감효과 분석)

  • Jeong-Heum Cho;Jinhwan Oh;Yeonju Kang;Yujin Nam
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.4
    • /
    • pp.18-26
    • /
    • 2023
  • Green-remodeling is to improve the energy performance of existing buildings that have been aged for more than 15 years since completion. In order to achieve the national greenhouse gas emission reduction plan in the building sector, it is necessary to analyze the carbon reduction effect by considering the internal carbon emissions that may occur during green-remodeling of old buildings. This study analyzed the effects of energy reduction and carbon emission reduction when green-remodeling was applied to old health centers constructed in 1992. When applying green-remodeling, the carbon emission reduction effect considered the embodied carbon emission of the improvement items and the carbon emission at the building operation stage. When applying green-remodeling to existing buildings, energy consumption was reduced by 39.3%, and carbon emissions were reduced by 48.9% after 27 years of green-remodeling. In order to reduce carbon emissions, it was important to apply a renewable system as an item to improve the performance of green-remodeling. In particular, it was confirmed that it is very important to consider the photovoltaic system as a top priority for the carbon emission reduction.

A Comparative Research on the Reconstruction and Remodeling of Low-rise, Dilapidated Apartment Buildings (노후저층 공동주택의 재건축과 리모델링 사업의 비교 연구)

  • 이효진;김동훈;김진호;임남기
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.75-80
    • /
    • 2002
  • The purpose of this study is to conduct researches on the aspects of reconstruction and remodeling of low-rise, dilapidated apartment buildings in the provinces, using comparative methodologies, consequently coming up with the findings in the following. 1) Unlike the rebuilding projects in which the movement process tends to be made in a bulk (in a simultaneous manner), it turns out that when it comes to remodeling, it would be advisable to attempt moving the inhabitants as a group either by the size of their residence or by the building. 2) Given the peculiarities of the construction management mechanism, remodeling projects might seem disadvantageous on the part of the management on account of inadequate accumulation of information and experience. Hence, based on the impeccable assessment of the current status of the subject buildings from the phase of planning, its imperative to closely look into and take into consideration a variety of direct and/or indirect factors in advance of the implementation. 3) A series of comparative researches from the perspective of economical efficiency that remodeling projects appear profitable considering the overall costs including financial expenses, varied taxes, and so on that will be eventually brought forth during the reconstruction period, and all the more so when allowing for the consequential effects which they ought to have upon the natural and human resources, environmental and ecological condition, business potentials, etc. Amelioration to be desired on the basis of the findings above.

  • PDF

Expression of Muscarinic Receptors and the Effect of Tiotropium Bromide in Aged Mouse Model of Chronic Asthma

  • Kang, Ji Young;Kim, In Kyoung;Hur, Jung;Kim, Seok Chan;Lee, Sook Young;Kwon, Soon Seog;Kim, Young Kyoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.1
    • /
    • pp.71-80
    • /
    • 2019
  • Background: Efficacy and safety of tiotropium bromide, a muscarinic receptor antagonist, in treatment of asthma have been reported. However, its effect on airway remodeling in chronic asthma of the elderly has not been clearly verified. The objective of this study was to investigate the effect of tiotropium and expression of muscarinic receptors as its related mechanism in an aged mouse model of chronic asthma with airway remodeling. Methods: BALB/c female mice age 6 weeks, 9 and 15 months were sensitized and challenged with ovalbumin (OVA) for three months. Tiotropium bromide was administered during the challenge period. Airway hyperresponsiveness (AHR) and pulmonary inflammation were measured. Parameters of airway remodeling, and expression levels of $M_2$ and $M_3$ receptors were examined. Results: Total cell with eosinophils, increased in the OVA groups by age, was decreased significantly after treatment with tiotropium bromide, particularly in the age group of 15 months. AHR and levels of interleukin (IL)-4, IL-5, and IL-13 were decreased, after tiotropium administration. In old aged group of 9- and 15-months-treated groups, hydroxyproline contents and levels of ${\alpha}$-smooth muscle actin were attenuated. Tiotropium enhanced the expression of $M_2$ but decreased expression of $M_3$ in all aged groups of OVA. Conclusion: Tiotropium bromide had anti-inflammatory and anti-remodeling effects in an aged mouse model of chronic asthma. Its effects seemed to be partly mediated by modulating expression $M_3$ and $M_2$ muscarinic receptors. Tiotropium may be a beneficial treatment option for the elderly with airway remodeling of chronic asthma.

An Analysis of Effects through Improved Insulation Performance for High-Density Residential Area on West High East Low Type (서고동저형 경사지 주거 밀집지역의 단열성능 개선 효과분석)

  • Lee, Seong-Hwa;Yoon, Seong-Hwan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.69-78
    • /
    • 2018
  • The purpose of this study is propose eco-friendly remodeling while protecting the living environment of existing residents and preserving the living in pleasant by considering the characteristic of high density sloped residential area. And then, the optimum insulation condition is analyzed based on the energy efficiency, economic analysis and environmental effect. It will be possible as the basic information for remodeling of each housing in sloped area. The energy demanding, cost and the carbon emission reduction is analyzed with the residential area in Seo-gu, Busan by eco-remodelling.

Effects of Three Thiazolidinediones on Metabolic Regulation and Cold-Induced Thermogenesis

  • Sohn, Jee Hyung;Kim, Jong In;Jeon, Yong Geun;Park, Jeu;Kim, Jae Bum
    • Molecules and Cells
    • /
    • v.41 no.10
    • /
    • pp.900-908
    • /
    • 2018
  • Insulin resistance is closely associated with metabolic diseases such as type 2 diabetes, dyslipidemia, hypertension and atherosclerosis. Thiazolidinediones (TZDs) have been developed to ameliorate insulin resistance by activation of peroxisome proliferator-activated receptor (PPAR) ${\gamma}$. Although TZDs are synthetic ligands for $PPAR{\gamma}$, metabolic outcomes of each TZD are different. Moreover, there are lack of head-to-head comparative studies among TZDs in the aspect of metabolic outcomes. In this study, we analyzed the effects of three TZDs, including lobeglitazone (Lobe), rosiglitazone (Rosi), and pioglitazone (Pio) on metabolic and thermogenic regulation. In adipocytes, Lobe more potently stimulated adipogenesis and insulin-dependent glucose uptake than Rosi and Pio. In the presence of pro-inflammatory stimuli, Lobe efficiently suppressed expressions of pro-inflammatory genes in macrophages and adipocytes. In obese and diabetic db/db mice, Lobe effectively promoted insulin-stimulated glucose uptake and suppressed pro-inflammatory responses in epididymal white adipose tissue (EAT), leading to improve glucose intolerance. Compared to other two TZDs, Lobe enhanced beige adipocyte formation and thermogenic gene expression in inguinal white adipose tissue (IAT) of lean mice, which would be attributable to cold-induced thermogenesis. Collectively, these comparison data suggest that Lobe could relieve insulin resistance and enhance thermogenesis at low-concentration conditions where Rosi and Pio are less effective.

Analysis of Stress Variation According to Removal of Shear Wall At the Remodeling of Shear Wall Type Apartment (벽식아파트 리모델링시 내력벽 제거에 따른 응력변화 분석)

  • Lee Jae-Cheol;Jung Jong-Hyun;Lim Nam-Gi
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.3 s.25
    • /
    • pp.72-80
    • /
    • 2005
  • The number of apartments has been increased, and it is time to activate the remodeling or reconstruction. Recently remodeling has been preferred to reconstruction, because reconstruction might cause many problems. At this point of time, remodeling could save resources, preserve environment, and expand the construction market places. However, most research for remodeling is aimed to improve the financial value, and structural effects being caused by floor plan modification has not been done yet quantitatively. Remodeling naturally brings to floor plan modification, and it can cause serious problems of structural side. So we made apartments an object of study, then analyzed stress variation of structural elements according to the removal of shear wall, supposing the floor plan modification. For this purpose, we selected a sample of universal apartment floor plan and extracted floor plan modification factors. Then we applied the factors to sample floor plan and organized the results of stress variation of structural elements. As results, walls are most harmful when the independent walls are removed, and in case of slabs, it is most critical when continuous walls are removed.