• 제목/요약/키워드: Remaining Strength

검색결과 260건 처리시간 0.032초

Ursolic Acid-Induced Elevation of Serum Irisin Augments Muscle Strength During Resistance Training in Men

  • Bang, Hyun Seok;Seo, Dae Yun;Chung, Yong Min;Oh, Kyoung-Mo;Park, Jung Jun;Arturo, Figueroa;Jeong, Seung-Hun;Kim, Nari;Han, Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제18권5호
    • /
    • pp.441-446
    • /
    • 2014
  • Ursolic acid (UA), a type of pentacyclic triterpenoid carboxylic acid purified from natural plants, can promote skeletal muscle development. We measured the effect of resistance training (RT) with/without UA on skeletal muscle development and related factors in men. Sixteen healthy male participants (age, $29.37{\pm}5.14$ years; body mass index=$27.13{\pm}2.16kg/m^2$) were randomly assigned to RT (n=7) or RT with UA (RT+UA, n=9) groups. Both groups completed 8 weeks of intervention consisting of 5 sets of 26 exercises, with 10~15 repetitions at 60~80% of 1 repetition maximum and a 60~90-s rest interval between sets, performed 6 times/week. UA or placebo was orally ingested as 1 capsule 3 times/day for 8 weeks. The following factors were measured pre-and post-intervention: body composition, insulin, insulin-like growth factor-1 (IGF-1), irisin, and skeletal muscle strength. Body fat percentage was significantly decreased (p<0.001) in the RT+UA group, despite body weight, body mass index, lean body mass, glucose, and insulin levels remaining unchanged. IGF-1 and irisin were significantly increased compared with baseline levels in the RT+UA group (p<0.05). Maximal right and left extension (p<0.01), right flexion (p<0.05), and left flexion (p<0.001) were significantly increased compared with baseline levels in the RT+UA group. These findings suggest that UA-induced elevation of serum irisin may be useful as an agent for the enhancement of skeletal muscle strength during RT.

표적 위치의 불확실성과 표적 가시성이 주의깜박거림 강도에 미치는 영향 (The Influence of Location Uncertainty and Visibility of Targets on the Strength of Attentional Blink)

  • 김기연;현주석
    • 인지과학
    • /
    • 제27권2호
    • /
    • pp.275-301
    • /
    • 2016
  • 주의깜박거림(AB)이란 시야의 고정 위치에 신속순차제시(RSVP)되는 항목들 중에 출현하는 두 표적에 대해 후행 표적(T2)이 선행 표적(T1)의 출현 이후 약 500ms 이내에 출현할 경우 그에 대한 의식적 수준의 보고가 어려워지는 현상을 의미한다. 본 연구는 T1 기억공고화에 요구되는 주의자원량이 T2에 대한 AB 강도를 결정한다는 병목 모형을 토대로 T1에 대한 표적 가시성 처치가 T2에 대한 주의깜박거림의 강도에 미치는 영향을 조사하였다. T1 저가시성 조건의 경우 T1에 배경화면과의 명암대비가 낮은 회색을 그리고 T1 고가시성 조건의 경우 선명한 색상을 부여해 흰색의 나머지 방해자극들과 구분되도록 처치하였다. 또한 표적 위치에 대한 불확실성 부여를 위해 시야의 네 위치에 전개되는 다중 RSVP 배열 내에 T1과 T2를 제시해 표적처리에 관여하는 주의 자원을 평균적으로 소진시켰다. 두 편의 실험에서 T2에 대한 AB의 강도는 고가시성 조건에서 상대적으로 큰 것이 관찰되었으며 T2의 가시성을 증가시켰을 때 T1 가시성 처치의 영향력이 더욱 분명해졌다. 이러한 결과는 T1 병목 해소를 위해 할당되는 가용한 주의 자원의 양이 부족할수록 더욱 T1 가시성 효과의 영향력이 분명해짐을 시사하며, T1의 가시성 수준이 T1 병목의 강도를 결정할 수 있다는 병목 모형의 제안을 지지한다.

60MPa급 고강도 콘크리트의 굵은골재 종류와 고온상태에 따른 변형특성 평가 (Evaluation on Strain Properties of 60 MPa Class High Strength Concrete according to the Coarse Aggregate Type and Elevated Temperature Condition)

  • 윤민호;최경철;이태규;김규용
    • 콘크리트학회논문집
    • /
    • 제26권3호
    • /
    • pp.247-254
    • /
    • 2014
  • 화재시 콘크리트 구조물은 구성재료의 상이한 열적특성으로 인해 강도가 저하하고 동시에 수직부재는 수평부재의 팽창에 의한 모멘트하중을 받아 전단파괴가 발생한다. 따라서 여러가지 화재곡선을 사용한 콘크리트 구조물의 화재시 거동에 대한 연구가 많이 이루어졌지만 주로 온도상승구간에서 발생하는 폭렬특성과 열팽창변형에 관한 연구가 대부분이다. 하지만 고온이 유지될 경우 발생할 수 있는 크리프변형은 화재시 구조물의 안정성에 큰 영향을 미치지만 상대적으로 연구가 미진한 상태이다. 또한 이러한 고온을 받는 콘크리트의 안정성에는 체적의 대부분을 차지하는 굵은골재의 열적특성이 큰 영향을 미치기 때문에 이 연구에서는 화강암계, clay계, clay-ash계 세 종류의 굵은골재를 사용한 콘크리트의 고온 역학적 특성을 평가했다. 그 결과 굵은골재의 성인으로 인한 내부공극 때문에 경량골재를 사용한 콘크리트가 일반골재를 사용한 콘크리트보다 높은 고온강도 및 탄성계수를 나타냈고 열팽창변형과 전체변형의 경우 더 낮은 변형률을 나타내어 온도상승구간에서의 구조적 안정성 측면에서 유리한 것으로 판단되었다. 그러나 고온크리프의 경우 내부공극으로 인해 더 큰 수축량이 발생하기 때문에 내화성능설계시에 이에 대한 추가적인 고려가 필요할 것으로 판단되었다.

Dicor와 수종 전장도재간의 전단결합강도 (THE SHEAR BOND STRENGTH BETWEEN DICOR AND SEVERAL VENEERING PORCELAINS)

  • 류경희;이선형
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.165-179
    • /
    • 1993
  • Dicor has not been prescribed routinely, in spite of many advantages, because of esthetic limitations by excessive translucency and external shading. In an attempt to solve these problems, the technique of veneering Dicor by aluminous poreclain has been used and recently Dicor Plus system was developed. The purpose of this study was to evaluate the compatibility between Dicor and several veneering porcelains by measuring the shear bond strength and observing the failure mode and interface appearance with SEM. Total 55 Dicor disks(10.0mm diam. X 3.0mm thickness) were fabricated by lost wax technique and divided into five groups of 11. Veneering porcelains such as Dicor Plus, Vitadur Alpha, Vitadur N, Vivodent, and Ceramco II were built up over the center of the treated Dicor surface using paper tube(5.0mm diam. X 4.0mm height) and fired according to the manufacturesr’instructions. A representative sample from each group was completely embedded in epoxy resin and crosssectioned, and remaining 50 samples were embedded in epoxy resin with the bonded area perpendicular to table base. The shear bond strengths were measured by applying the shear load parallel to Dicor surface close to the bonded area. Failure modes and interface appearances were observed using SEM at 15 and 1000 magnification respectively. The obtained results were as follows : 1. The mean shear bond strengths showed Dicor-Dicor Plus(10.53 MPa); Dicor-Vitadur Alpha(8.84 MPa); Dicor-Vitadur N(7.37 MPa); Dicor-Vivodent(4.28 MPa); Dicor-Ceramco II(0.89 MPa). 2. The shear bond strength of Dicor-CeramcoII was significantly decreased compared with Dicor-Dicor Plus(p<0.01), but had no significant difference compared with Dicor-Vivodent(p>0.01). 3. The shear bond strengths of Dicor-Vitadur Alpha and Dicor-Vitadur N were not significantly different compared with Dicor-Dicor Plus(p>0.01). 4. SEM examination of bond failure modes revealed that Dicor-Dicor plus, Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited cohesive failure within Dicor and Dicor-Vivodent exhibited adhesive failure. And Dicor-Ceramco III exhibited adhesive failure and cohesive failure within CeramcoIII together. 5. SEM examination of interfaces revealed that Dicor-Dicor Plus exhibited the most tight contact and Dicor-Vitadur Alpha, Dicor-Vitadur N exhibited acceptible contacts. But Vivodent exhibited discontinuous gap and Ceramco II exhibited large continuous gap.

  • PDF

불소처리된 치근상아질에 대한 심미수복재의 결합에 관한 연구 (A STUDY ON THE BOND OF AESTHETIC RESTORATIVE MATERIALS TO FLUORIDE TREATED ROOT DENTIN)

  • 탁홍수;박상진;민병순;최호영;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.197-212
    • /
    • 1998
  • The purpose of this study was to evaluate the effects of fluoride application on the aspect of shear bond strength of three aesthetic restorative materials to dentin. One light-cured composite resin(Palfique Esterite) and two light-cured glass ionomer cements(Fuji II LC and Compoglass)were used in this study. 120 permanent molars were used for this study. The teeth were extracted due to the origin of periodontal disease. The crowns of all teeth were removed, and the remaining roots were embedded in epoxy resin. The mesial or distal surfaces of roots were ground flat to expose dentin and polished on wet 320-, 400-, and 600 grit SIC papers for a total of 120 prepared flat root dentin surfaces. The prepared samples were divided into six groups. Group 1, 3, and 5 were control groups and group 2, 4, and 6 were experimental groups. Sixty samples for experimental groups were treated with 2% NaF solution for 5 minutes. Group 1 and 2 were bonded with Plafique Esterite, group 3 and 4 were bonded with Fuji II LC, and group 5 and 6 were bonded with Compoglass. After 24 hours water storage at $37{\pm}1^{\circ}C$, all samples were subjected to a shear to fracture with Instron universal testing machine(No.4467) at 1.0 mm/min displacement rate. Dentin surfaces treated with each conditioners before bonding and interfacial layers between dentin and aesthetic restorative materials were observed under Scanning Electron Microscope(Hitachi S-2300) at 20Kvp. The data were evaluated statistically at the 95% confidence level with ANOVA test. The result were as follows; 1. Among the control groups, group 1 showed strongest bond strength and group 3 showed weakest. 2. Among the experimental groups, group 2 showed strongest bond strength and group 6 showed weakest. 3. Statistical analysis of the data showed that pretreatment of dentin with 2% NaF solution significantly decreased the bond strength of three aesthetic restorative materials to dentin(P<0.05). 4. SEM findings of fluoride treated dentin surfaces (2, 4, 6 group) demonstrated dentin surfaces covered with fluoridated reaction products. 5. Except group 4 and 6, resin tags were formed in all groups.

  • PDF

Behaviour of hybrid fibre reinforced concrete beams strengthened with GFRP laminates

  • Ibrahim, S. Syed;Eswari, S.;Sundararajan, T.
    • Structural Engineering and Mechanics
    • /
    • 제66권5호
    • /
    • pp.631-636
    • /
    • 2018
  • This study aims to investigate the flexural behaviour of glass fibre reinforced polymer (GFRP) laminated hybrid fibre reinforced concrete (HFRC) beams. The flexural and ductility performance of GFRP laminated HFRC beams having different proportions of polyolefin and steel fibres with 1.0% of total volume fraction were investigated. The parameters of this investigation included: load and deflection at first crack, yield, and ultimate stages, ductility and crack width. A total of seven beams of $150{\times}250mm$ in cross-section were tested in the laboratory over an effective span of 2800 mm. One reinforced concrete (RC) beam without any internal or external GFRP was taken as the reference beam. Of the remaining six beams, one beam was strengthened with GFRP, one beam with 100% steel fibres was strengthened with GFRP and four beams, each with different volume proportions of polyolefin and steel fibres (20:80, 30:70, 40:60, 50:50) were strengthened with GFRP. All the above beams were tested until failure. The experimental results show that a fibre volume proportion of 40:60 (polyolefin-steel) has significantly improved the overall performance of the tested beams.

음향방출기법을 이용한 A106 탄소강의 부식평가 (Evaluation on Corrosion of A106 Carbon Steel using AE Technique)

  • 이진경;이상필
    • 한국해양공학회지
    • /
    • 제22권5호
    • /
    • pp.100-105
    • /
    • 2008
  • A106 Carbon Steel has recently been used as the material for pipes, nozzles, and tank shells in nuclear power plants. Its corrosion resistance gives the steel many advantages for use in structures under high temperature and high pressure. This steel is also expected to be used as a structural material in the shipbuilding industry for applications involving severe conditions, such as high temperature and pressure. In this study, the mechanical properties of A106 carbon steel were evaluated in regard to its corrosion times. The tensile and yielding strengths decreased as the corrosion time increased. In particular, the tensile strength was influenced by corrosion. In addition, an acoustic emission (AE) technique was used to clarify the microscopic damage to specimens that had undergone corrosion for a certain period. It was found that AE parameters, such as events, energy, duration time, and amplitude were useful for evaluating the degree of damage and remaining life of the corroded specimen. Various properties of the waveform and frequency range were also seen, based on the degree of damage to the specimen from the corrosion time.

국제공동연구 PARTRIDGE를 통한 확률론적 건전성 평가 기술 개발 현황 (Current Status of an International Co-Operative Research Program, PARTRIDGE (Probabilistic Analysis as a Regulatory Tool for Risk-Informed Decision GuidancE))

  • 김선혜;박정순;김진수;이진호;윤은섭;양준석;이재곤;박홍선;오영진;강선예;윤기석;박재학
    • 한국압력기기공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.62-69
    • /
    • 2013
  • A probabilistic assessment code, PRO-LOCA ver. 3.7 which was developed in an international co-operative research program, PARTRIDGE was evaluated by conducting sensitivity analysis. The effect of some variables such as simulation methods (adaptive sampling, iteration numbers, weld residual stress model), crack features(Poisson's arrival rate, maximum numbers of cracks, initial flaw size, fabrication flaws), operating and loading conditions(temperature, primary bending stress, earthquake strength and frequency), and inspection model(inspection intervals, detectable leak rate) on the failure probabilities of a surge line nozzle was investigated. The results of sensitivity analysis shows the remaining problems of the PRO-LOCA code such as the instability of adaptive sampling and unexpected trend of failure probabilities at an early stage.

Influence of vertical load on in-plane behavior of masonry infilled steel frames

  • Emami, Sayed Mohammad Motovali;Mohammadi, Majid
    • Earthquakes and Structures
    • /
    • 제11권4호
    • /
    • pp.609-627
    • /
    • 2016
  • Results of an experimental program are presented in this paper for the influence of vertical load on the in-plane behavior of masonry infilled steel frames. Five half-scaled single-story, single-bay steel frame specimens were tested under cyclic lateral loading. The specimens included four infilled frames and one bare frame. Two similar specimens as well as the bare frame had moment-resisting steel frames, while the remaining two specimens had pinned steel frames. For each frame type, one specimen was tested under simultaneous vertical and lateral loading, whereas the other was subjected only to lateral loading. The experimental results show that the vertical load changes the cracking patterns and failure modes of the infill panels. It improves dissipated hysteresis energy and equivalent viscous damping. Global responses of specimens, including stiffness and maximum strength, do no change by vertical loading considerably. Regarding the ductility, the presence of vertical load is ignorable in the specimen with moment-resisting frame. However, it increases the ductility of the infilled pinned frame specimen, leading to an enhancement in the m-factor by at least 2.5 times. In summary, it is concluded that the influence of the vertical load on the lateral response of infilled frames can be conservatively ignored.

소형펀치법에 의한 고온배관재료의 크리프열화 평가 (The Evaluation of Creep Degradation for the High Temperature Pipe Material by Small Punch Test)

  • 유근봉;장성호;송기욱;하정수;김재훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.37-42
    • /
    • 2000
  • The boiler tubes and steam Pipes operating both at high temperature and pressure for a long period of time in a power plant are degraded by creep because of internal pressure. So, the remaining life of a component is evaluated by the creep rupture strength. Although the conventional method to evaluate the creep damage is widely used, it has some disadvantages such as requires large size specimen and long employed to evaluate the correlation between fracture toughness and evaluation time. Recently, new method so called "small lunch test' is used to evaluate degradation of creep. In this study, a conventional creep test and a small punch test are conducted using 2.25Cr-1Mo steel which is mainly used for the boiler tubes and steam pipes in power plant. The creep life, approximately 1,500 hrs, is determined by conventional method under a severe condition then specimens for a small Punch test are obtained after certain time intervals such as 1/4, 1/2 and 3/4 of final rupture time, respectively.

  • PDF