• Title/Summary/Keyword: Reliability standard

Search Result 1,714, Processing Time 0.028 seconds

A Study on the Usefulness of the New Foot Oblique Projection (새로운 발 사방향 검사법의 유용성에 관한 연구)

  • Kim, Min-Suk;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.443-449
    • /
    • 2021
  • In this study, the purpose is to present the foot inclination angle for realizing an image similar to that of the existing examination method and to present the clinical usefulness of the new examination method through comparison between the existing examination method and the newly designed standing foot oblique projection. A foot phantom was used, and the magnification of the image according to the angle was quantitatively evaluated by attaching a nut to the position of the cuboid of the phantom. The internal oblique image acquired using a 30° wedge was set as the standard image. And that image was compared with the images acquired by changing the angle of the foot from 20° to 65° at intervals of 5°. Image evaluation was performed by 3 radiological technologists, and qualitative evaluation using a Likert 5-point scale for evaluation items of true oblique view and quantitative evaluation of the value obtained by measuring the diameter of a nut in each image were performed as image evaluation. For data analysis, reliability analysis between the measure and comparative analysis of the average value for each angle were performed. The qualitative evaluation score for each image was 4.5 to 5 points for most questions in the case of the standard image. And 4 points or less for most questions in the images with a foot angle of 45° or less, and an evaluation score close to the standard image was obtained in the image of 50° or more. And in the quantitative evaluation, the diameter of the nut was measured to be 9.28~9.56 mm. The qualitative evaluation showed a reliability of 0.95~1.0 and the quantitative evaluation was 0.62. As a result of comparing and analyzing the average of the quantitative and qualitative average values for each angle image, the group with the average value most similar to the standard image was images obtained at 55° and 60°, and in the post-analysis, the images of both groups were the same group as the standard image(p<0.01). As a result of this study, it was found that the angle of inclination of the foot for realizing the image most similar to the existing image in the standing foot oblique projection is 55°~60°. In addition, if this test method is applied to the clinic, it is believed that it will help prevent safety accidents such as falls during the test and improve test efficiency by minimizing the movement of patients for the test.

Intercomparison and Determination of Trace Elements in Urban Dust by Neutron Activation Analysis (중성자방사화분석법을 이용한 대기분진중의 미량원소 비교분석)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Kim, Sun-Ha;Park, Kwang-Won;Kang, Sang-Hun
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.179-188
    • /
    • 2000
  • Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratorie's mean as target standard deviation, and a good result was obtained that the values fall between -1 and +1 except some elements.

  • PDF

Effects of the Method of FTSs on the Performance of HPAs (FTS 방식이 전력증폭기의 성능에 미치는 영향)

  • Kang, Sanggee
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.1
    • /
    • pp.8-13
    • /
    • 2013
  • It is necessary to develop the next generation FTS which is suitable for our environment and effectively operates many launch vehicles. Standard tone, Secure tone, MHA, EFTS and DSSS are studied for the next generation FTS. FTS requires a high quality of performance and reliability because of their specific mission. And few FTSs are needed but the price is very expensive. Therefore we must investigate a part of the FTS whether the part can be reused for a part of the next FTS. In this paper, we use CCDF of the transmitted signal from FTS as the method to study a possibility of reusing HPA used in the present system. The simulation results show that PEP of Standard tone is 0.21dB and Secure tone and MHA has the same PEP. CPFSK's PEP is 1.81dB and PEP of DSSS using BPSK modulation is 2.6dB.

A study on the Purchase Appraisal Standard and Post-purchase Satisfaction of Natural Dyeing Products (천연염색제품 구매 평가기준 및 구매 후 만족도)

  • Park, Young-Hee
    • Fashion & Textile Research Journal
    • /
    • v.14 no.1
    • /
    • pp.64-74
    • /
    • 2012
  • The purpose of this study was to find purchase appraisal standard and post-purchase satisfaction for natural dyeing products. The data used for this study were collected from the women in their from 20's to 50's who are living in the regions of Busan, Ulsan, and Gyeongnam in Korea. The questionnaire of 537 copies was used for a statistical analysis. To analyze data, 2-test, t-test, Cronbach's a test, factor analysis, ANOVA, Duncan test, regression analysis, etc. were carried out. A used statistical package was SPSS 14.0. The analysis results were as follows. The purchase appraisal standards for natural dyeing products were identified as practicality and reliability, suitability of use, symbolic property of status, design property, and convenience of buying. As the analysis result for purchase appraisal standard according to the demographic characteristics, the purchase appraisal standard according to most demographic characteristics showed significant difference. The factors of post-purchase satisfaction for natural dyeing products were verified as product modification and durability, design and price, hygienic property and product quality. As the analysis results of post-purchase satisfaction for natural dyeing products according to demographic characteristics, the post-purchase satisfaction according to demographic characteristics showed significant difference. The factors affecting post-purchase satisfaction were verified as product quality, kinds of item, color change, product lifespan, color change, etc. Consequently, because the purchase appraisal standard of natural dyeing product is very various, it is necessary to enhance post-purchase satisfaction of natural dyeing products by reflecting these factors in advance at the product development stage.

Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution (모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성)

  • Cheon, Jun Hong;Cho, Eun Bit;Yoo, Seon Hee;Kim, Nyeon Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2016
  • Purpose The importance of quality control by the error to a minimum, which for the purpose of enhancing the reliability of the examination is not be emphasized excess. Currently, most nuclear medicine laboratory are conducting the internal and external quality control, and they are applying the Levey-Jennings or Westgard Multi-Rules by using the commercialized quality control materials. The reliability of the nuclear medicine blood test which affects the diagnosis of patients and the treatment policy is being secured through this quality control activity. Therefore, researchers will evaluate the utility of the statistic quality control using the population distribution of the nuclear medicine blood test conducted targeting the checkup examinees by the additional technique of the reliability improvement. Materials and Methods A statistic analysis was performed about 12 items of the nuclear medicine blood test targeting 41,341 peoples who used the health screening and promotion center in Asan Medical Center from January, 2014 to December, 2014. The results of 12 items of the nuclear medicine blood test was divided into the monthly percentage of three groups: within reference values, over reference, and under reference to analyze the average value of the population distribution, standard deviation, and standard deviation index (SDI). Results The standard deviation of the population distribution mostly showed a result within ${\pm}2SD$ in all groups. However, When the standard deviation of the population distribution represented a result over ${\pm}2SD$, it was confirmed SDI was showing a result of SDI > -2 or SDI > 2. As a result of analyzing the population distribution of 12 items(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin) of the nuclear medicine blood part basic test, when SDI of the monthly percentage which deviated from the reference values was over ${\pm}2.0$, CA19-9 September was 2.2, Anti-Tg-Ab may was 2.2, Insulin January was 2.3, Insulin March was 2.4. It was confirmed these cases were attributed to the abnormality of the test reagent (maximum combination rate of isotope reagent declined) and the decline of the test response time. Conclusion The population distribution includes the entire attribute which becomes the study object. It is expected the statistic quality management using the population distribution which was conducted targeting the checkup examinees by dividing into three groups: within reference values, over reference, and under reference by means of this characteristics will be able to play a role of complementing the internal quality control program which is being carried out in the laboratory.

  • PDF

Evaluation of Whole Effluent Toxicity (WET) Proficiency Testing for Water Quality Measurement Agencies in Korea (국내 수질측정대행업에 대한 생태독성 숙련도시험 평가)

  • Park, Woo Sang;Kim, Sang Hun
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.568-573
    • /
    • 2013
  • In this study, we conducted whole effluent toxicity (WET) proficiency testing based on the results which $EC_{50}$ value of 3 types (A, B, C) unknown samples calculated from 32 water quality measurement agencies in Korea. WET proficiency testing was expected to their improve of analysis skill and ensure reliability of analysis results. Ultimately, it is intended to promote the reliable enforcement of WET. WET proficiency testing was evaluated using the z-score, robust z-score and the results showed that 30 participating agencies were "compliance". In addition, $EC_{50}$ values of "unknown sample A" were the normal distribution. Therefore, "unknown sample A" was considered as the most suitable standard toxicity substance.

Development of CPC/COLSS Simulation Model for YGN#3,4 Simulator

  • Kim, Dong-Wook
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.251-256
    • /
    • 1997
  • The safety and reliablity of nuclear power plant operations relies heavily on the plant operators ability to respond to various emergency situations. It has become standard industry practice to utilize simulators to improve the safety and reliability of nuclear power plants operations. The simulators built for Younggwang#3("YGN#3"), which is based on the Korean Standard Nuclear Power Plant ("KSNPP")design, has been developed precisely for this purpose. The YGN#3 simulator is the first simulator in Korea to be developed locally and is now operational on site. A particular attention was placed on the development of CPC/COLLS safety system which is unique to the YGN#3. The effort to develop CPC/COLLS simulation model has been successful and plans exist for applying this model to simulator projects in the future.jects in the future.

  • PDF

THE ACCURACY OF H$\bate$CCD PHOTOMETRY (H$\bate$CCD 측광의 정확도)

  • 김철희;김승리
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.2
    • /
    • pp.208-231
    • /
    • 1994
  • We have undertaken CCD observations of fie이 standard stars with H$\beta$ photometric system to investigate the reliability of H$\beta$ CCD photometry. Flat fielding with dome flat and sky flat for H$\beta$w and H$\beta$n filter was compared with that of B filter in UBV system and, from these, we have not found any difference. It was confirmed that there is a good linear relationship between our H$\beta$ values observed with 2.3m reflector and standard values. However, H$\beta$ values observed with 60cm reflector at Sobaeksan Astronomy Observatory showed very poor relationship. To investigate the accuracy of H$\beta$ CCD photometry for fainter objects, open cluster NGC2437 was observed and reduced with DoPHOT, and the results were compared with those for photoelectric photometry of Stetson(1981).

  • PDF

Implementation of High Speed Serial interface for testing LCD module by using the MDDI (MDDI방식 LCD모듈의 테스트하기 위한 고속직렬통신 인터페이스 구현)

  • Kim, Sang-Mok;Kang, Chang-Hun;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.212-214
    • /
    • 2005
  • The MDDI(Mobile Digital Display Interface) standard is an optimized high-speed serial interconnection technology developed by Qualcomm and supports the VESA(Video Electronics Standard Association). It increases reliability and reduces power consumption in clamshell phones by decreasing the number of wires to interconnect with the LCD display. In this paper, the MDDI host is designed using VHDL and implemented on FPGA. We demonstrates that the MDDI host is connected with S3CA460 LCD controller is designed by Samsung Electronics Co. and display a steal image to the LCD.

  • PDF

The Effect of Selection Attributes for Goods of Dessert Cafe on Product Satisfaction and Long-term Orientation (디저트 카페의 상품 선택 속성이 만족과 장기 지향성에 미치는 영향)

  • Jeon, Kyung-Chul
    • Culinary science and hospitality research
    • /
    • v.23 no.5
    • /
    • pp.140-150
    • /
    • 2017
  • The purpose of the study was to provide useful implications for management of dessert cafe by discovering selection attributes for product satisfaction and long-term orientation. Using SPSS 22.0 and AMOS 220 Version, the collected data from customers of dessert cafe in Seoul and metropolitan areas were analyzed for frequency analysis, exploratory factor analysis, confirmatory factor analysis, reliability analysis, and covariance structure analysis. As results of hypothesis verification, firstly, service standard and product diversity had a significant effect on product satisfaction of dessert cafe. Secondly, tastes and nutrients influenced positively long-term orientation of dessert cafe. Meanwhile, service standard, mood, and product diversity did not have a significant effect on long-term orientation. Thirdly, product satisfaction affected positively long-term orientation. The results of the study provided useful implications for management of dessert cafe.