• Title/Summary/Keyword: Reliability standard

Search Result 1,701, Processing Time 0.029 seconds

Inter-rater·absolute Reliability and Concurrent Validity of Tinetti-gait Scale (Korean version) in Stroke Patients (뇌졸중 환자들의 한국판 Tinetti-보행 척도의 측정자간·절대적 신뢰도와 동시 타당도)

  • An, Seung-Heon;Lee, Dong-Geon;Lee, Yun-Bok;Lee, Gyu-Chang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.201-211
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate the inter-rater absolute reliability and the concurrent validity of the Tinetti-gait scale that was translated into Korean for chronic stroke patients. METHODS: Fifty-two patients with post-stroke participated in this study. Inter-rater reliability was analyzed by Intraclass Correlation Coefficient ($ICC_{3,1}$) and Kappa coefficient, and absolute reliability was analyzed by the Standard Error of Measurement (SEM), and the Minimal Detectable Change (MDC). Concurrent validity was analyzed by correlating between the Tinetti-gait scale and physical functions. The physical functions were measured by using the Dynamic Gait Index(DGI), 10m walking test(10WT), One Leg Standing Test of affected/non-affected side(OLST), Sit to Stand test(STS), (Fugl Meyer assessment of Lower Extremity(FM-LE). RESULTS: The inter-rater reliability of the Tinetti-gait scale was high; $ICC_{(3,1)}=.91$ (95% CI=.85~.95) (very reliable), the range of Kappa coefficient were .73~.92 (substantial~good). The inter-rater agreement of the each item in Tinetti-gait scale ranged from .74 to .92 (95 % CI=.59~.95) (reliable~very reliable). The SEM and MDC were .56 and 1.55, respectively. In the results of concurrent validity, there were moderate positive correlation between Tinetti-gait scale and DGI (r=.78), 10WT (r=.74), OLST (r=.65~.73), FM-LE (r=67). And there was moderate negative correlation between Tinetti-gait scale and STS (r=-79) (p<.01). CONCLUSION: The Tinetti-gait scale(Korean version) was a reliable and valid tool to measure gait ability in patients with chronic stroke. Thus, it could be a useful tool for examining a gait ability of post-stroke patients. Further study should be conducted to investigate the usability to predict fall risk of post-stroke patients of the Tinetti-gait scale.

Reliability study of the Pectoralis Minor Muscle Thickness Measurement using Rehabilitative Ultrasound Imaging

  • Lim, Ji Young;Lee, Se-Yeong;Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2021
  • PURPOSE: This study examined the imaging procedure of pectoralis minor muscle thickness and assessed the intra- and inter-rater reliability of the muscle thickness measured by two raters using rehabilitative ultrasound imaging (RUSI) in healthy individuals. METHODS: Fifteen participants (aged 21 - 28, seven females, and eight males) were involved in the study. The primary rater palpated the coracoid process and the fourth rib, defined as the width of the index finger lateral to the sternum to avoid breast tissues, and lined the two landmarks. The second examiner checked 1 / 3 (1st point) and 1 / 2 (2nd point) of the line length as measurement points. The two raters obtained right side muscle images of the participants at a standardized sitting position using RUSI with a 7.5 MHz linear transducer at 40mm depth. For intra-rater reliability, the principal rater took three images per point and tried to take one more with an interval. For the inter-rater reliability, the other rater performed the same tasks as the principal rater on the same day. The reliability was analyzed using the intra-class correlation coefficient (ICC), the standard error of the measurement (SEM), and Bland and Altman plots. RESULTS: The reliability at all points was excellent for the same rater (ICC3,1 = .973 - .978, SEM = .042 - .046), and between raters (ICC2,1 = .939 - .959, SEM = .059 - .097). CONCLUSION: These findings show that the RUSI could be reliable for examining the pectoralis minor muscle thickness in healthy individuals at all measurement sites.

Reliability Prediction of Long-term Creep Strength of Gr. 91 Steel for Next Generation Reactor Structure Materials (미래형 원자로 구조 재료용 Gr. 91 강의 장시간 크리프 강도의 신뢰성 예측)

  • Kim, Woo-Gon;Park, Jae-Young;Yin, Song-Nan;Kim, Dae-Whan;Park, Ji-Yeon;Kim, Seon-Jin
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.4
    • /
    • pp.275-280
    • /
    • 2011
  • This paper focuses on reliability prediction of long-term creep strength for Modified 9Cr-1Mo steel (Gr. 91) which is considered as one of the structural materials of next generation reactor systems. A "Z-parameter" method was introduced to describe the magnitude of standard deviation of creep rupture data to the master curve which can be plotted by log stress vs. The larson-Miller parameter (LMP). Statistical analysis showed that the scattering of the Z-parameter for the Gr. 91 steel well followed normal distribution. Using this normal distribution of the Z-parameter, the various reliability curves for creep strength design, such as stress-time temperature parameter reliability curves (${\sigma}$-TTP-R curves), stress-rupture time-reliability curves (${\sigma}-t_{r}-R$ curves), and allowable stress-temperature- reliability curves ([${\sigma}$]-T-R curves) were reasonably drawn, and their results are discussed.

Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults

  • Jamal, Fatin Nabilah;Dzulkarnain, Ahmad Aidil Arafat;Shahrudin, Fatin Amira;Marzuki, Muhammad Nasrullah
    • Journal of Audiology & Otology
    • /
    • v.25 no.1
    • /
    • pp.14-21
    • /
    • 2021
  • Background and Objectives: There is growing interest in the use of the Level-specific (LS) CE-Chirp® stimulus in auditory brainstem response (ABR) due to its ability to produce prominent ABR waves with robust amplitudes. There are no known studies that investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus. The present study aims to investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus and compare its reliability with the ABR to standard click stimulus at multiple intensity levels in normal-hearing adults. Subjects and Methods: Eleven normal-hearing adults participated. The ABR test was repeated twice in the same clinical session and conducted again in another session. The ABR was acquired using both the click and LS CE-Chirp® stimuli at 4 presentation levels (80, 60, 40, and 20 dBnHL). Only the right ear was tested using the ipsilateral electrode montage. The reliability of the ABR findings (amplitudes and latencies) to the click and LS CE-Chirp® stimuli within the same clinical session and between the two clinical sessions was calculated using an intra-class correlation coefficient analysis (ICC). Results: The results showed a significant correlation of the ABR findings (amplitude and latencies) to both stimuli within the same session and between the clinical sessions. The ICC values ranged from moderate to excellent. Conclusions: The ABR results from both the LS CE-Chirp® and click stimuli were consistent and reliable over the two clinical sessions suggesting that both stimuli can be used for neurological diagnoses with the same reliability.

Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults

  • Jamal, Fatin Nabilah;Dzulkarnain, Ahmad Aidil Arafat;Shahrudin, Fatin Amira;Marzuki, Muhammad Nasrullah
    • Korean Journal of Audiology
    • /
    • v.25 no.1
    • /
    • pp.14-21
    • /
    • 2021
  • Background and Objectives: There is growing interest in the use of the Level-specific (LS) CE-Chirp® stimulus in auditory brainstem response (ABR) due to its ability to produce prominent ABR waves with robust amplitudes. There are no known studies that investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus. The present study aims to investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus and compare its reliability with the ABR to standard click stimulus at multiple intensity levels in normal-hearing adults. Subjects and Methods: Eleven normal-hearing adults participated. The ABR test was repeated twice in the same clinical session and conducted again in another session. The ABR was acquired using both the click and LS CE-Chirp® stimuli at 4 presentation levels (80, 60, 40, and 20 dBnHL). Only the right ear was tested using the ipsilateral electrode montage. The reliability of the ABR findings (amplitudes and latencies) to the click and LS CE-Chirp® stimuli within the same clinical session and between the two clinical sessions was calculated using an intra-class correlation coefficient analysis (ICC). Results: The results showed a significant correlation of the ABR findings (amplitude and latencies) to both stimuli within the same session and between the clinical sessions. The ICC values ranged from moderate to excellent. Conclusions: The ABR results from both the LS CE-Chirp® and click stimuli were consistent and reliable over the two clinical sessions suggesting that both stimuli can be used for neurological diagnoses with the same reliability.

Development of a real-time PCR method for detection and quantification of the parasitic protozoan Perkinsus olseni

  • Gajamange, Dinesh;Yoon, Jong-Man;Park, Kyung-Il
    • The Korean Journal of Malacology
    • /
    • v.27 no.4
    • /
    • pp.387-393
    • /
    • 2011
  • The objective of this study was to develop a real-time PCR method for the rapid detection and quantification of the protozoan pathogen Perkinsus olseni using a TaqMan probe. For the standard, genomic DNA was extracted from $10^5$ in vitro-cultured P. olseni trophozoites, and then 10-fold serial dilutions to the level of a single cell were prepared. To test the reliability of the technique, triplicates of genomic DNA were extracted from $5{\times}10^4$ cells and 10-fold serial dilutions to the level of 5 cells were prepared. The standards and samples were analyzed in duplicate using an $Exicycler^{TM}$ 96 real-time quantitative thermal block. For quantification, the threshold cycle ($C_T$) values of samples were compared with those obtained from standard dilutions. There was a strong linear relationship between the $C_T$ value and the log concentration of cells in the standard ($r^2$ = 0.996). Detection of DNA at a concentration as low as the equivalent of a single cell showed that the assay was sensitive enough to detect a single cell of P. olseni. The estimated number of P. olseni cells was similar to the original cell concentrations, indicating the reliability of P. olseni quantification by real-time PCR. Accordingly, the designed primers and probe may be used for the rapid detection and quantification of P. olseni from clam tissue, environmental water, and sediment samples.

The Resistance Characteristics and Reliability Evaluation of an Insulation Ring Type of Corrugated Stainless Steel Tubing(CSST) (절연링형 금속플렉시블호스(CSST)의 저항 특성 및 신뢰성 평가)

  • Lee, Jang-Woo;Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.25-31
    • /
    • 2016
  • This paper has analyzed the structure, applicable regulations and the resistance characteristics of insulation ring type of CSST (Corrugated Stainless Steel Tubing for Gas). With the flammability test conducted in accordance with KS C IEC 60811-1-1, the evaluation of insulation resistance, temperature characteristics, and reliability has been conducted. An insulation ring type CSST consists of protective coating, tube, nut, insulation ring, packing, socket, and ball valve. Connecting an insulation ring type CSST to gas tubings for gas appliance is not permitted, moreover, the product shall be installed inside a sleeve pipe in case of buried installation such as the ceiling. Damages on protective coating and tube were detected when fire was applied to the test sample with a portable torch for 60 seconds. The insulation resistance of a normal product was $49.59M{\Omega}$, while that of the product completed the flammability test reduced to $9.21M{\Omega}$. The mean insulation resistance within the confidence Interval of 95% using the mini tap program 17 was $49.59M{\Omega}$ and the mean insulation resistance within the confidence interval reduced to $9.21M{\Omega}$. In the normal distribution analysis of 95% confidence interval, the value-P of the normal product was stable at 0.075 and AD(Anderson-Darling) statistic value was turned out to be 0.063, which is very normal, and the standard deviation was analyzed as 0.2586. The value P of the product completed the flammability test resulted in 0.005, the AD was 1.355 and the standard deviation reduced to 0.07908.

An Analytical Study on the Durability Standard of Ground Structures Monitoring Sensors (지반구조물 계측센서의 내구연한 기준에 대한 분석적 연구)

  • Woo, Jong-Tae
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2021
  • Purpose & Method: The purpose of this study is the theoretical study on the durability standard of ground structures monitoring sensors. A survey on the durability criteria for construction monitoring sensors of domestic construction companies and the income tax implementation regulations, the standard years of contents such as buildings and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. Result: The durability criterion such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the ground structure, is 8 to 10 years. Conclusion: The actual durability analysis by comparing the reliability of various monitoring sensors installed in dams at home and abroad, As a result of comprehensive study on the loss and damage rate of the maintenance monitoring sensor installed in the tunnel, the proper durability period of the built-in type monitoring sensor such as domestic pore pressure meter and earth pressure meter installed in the structure or the ground is 5 to 8 years it seems reasonable.

A Comparative Analysis of Domestic and Foreign Cloud Service Agreements (국내외 클라우드 서비스 이용약관 비교 분석 연구)

  • Song, Jiwon;Lee, Hwansoo
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.6 no.8
    • /
    • pp.499-509
    • /
    • 2016
  • The MSIP has implemented "Act on The Development of Cloud Computing and Protection of Its Users" from September 2015 and invigorated the cloud service industry. The act mainly includes the improvement cloud computing reliability and user protection for the development foundation and use activation. In order to expand the cloud market, it is important to increase the reliability of individual users. However, practical discussions and approach for cloud services adoption are still limited. In fact, there is no agreement standard for domestic cloud services. As a user agreement is not standardized, users feel difficulty compare to each agreement of cloud service provider and may be damaged because of unfair terms. Thus, it is necessary to examine the unfairness of cloud service agreement for user protection. This study analyzes domestic and foreign cloud service agreements including Practical Guide to Cloud Service Agreement of Cloud Standards Customer Council and suggests the direction of the standard agreement of cloud services.

Verification of ERP Standard Time Using TOC Technique and Improvement of MES Routing Point (TOC 기법을 적용한 ERP 표준시간 검증 및 MES 공정실적개선)

  • Kim, Sung-Min;Ahn, Jaekyoung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.22-33
    • /
    • 2018
  • Recently domestic manufacturing companies have been experiencing worsening profitability and stunted growth due to the long-term economic recession and the rapid rise of developing countries such as China and Southeast Asia. These difficulties force many companies to concentrate their core competencies on new value creation and innovation in order to gain momentum for new growth. Enterprise Resource Planning (ERP) has been considered as one of viable solutions. Among the various modules in ERP, shop floor control function in the production management module is rather limited. In order to overcome this problem, Manufacturing Execution System (MES) has been used as a subsystem which has a strong information gathering power and flexibility. Both systems interact closely with each other. In particular, ERP requires fast, accurate shop floor information at MES. This paper describes how to synchronize relevant information between ERP and MES with theory of constraints (TOC). The processing time information transmitted from the MES workplace is received at the ERP workplace. In the process, the received processing time is causing information distortion in ERP, when the information gathering standard of MES is different from the ERP information interpretation standard. The Drum-Buffer-Rope theory of TOC was applied to resolve this problem, therefore, information synchronization between both systems was made. As a precondition, the standard time of the upper ERP system was rearranged according to the capacity constraints resource. As a result, standard time restructuring has affected changes in labor costs. Standard labor costs have come close to actual ones, and information synchronization of MES transmission data has improved the reliability of standard product costs, such that it enabled various company-wide restructuring actions to be much more effective.