• Title/Summary/Keyword: Reliability standard

Search Result 1,685, Processing Time 0.026 seconds

Reliability-based Flaw Assessment of a Mooring Chain Using FORM and SORM (FORM 및 SORM을 이용한 무어링 체인의 신뢰성 기반 결함평가)

  • Lee, Choong-Hyun;Kim, Yooil
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.5
    • /
    • pp.430-438
    • /
    • 2017
  • This study presents the reliability-based flaw assessment for the crack in the mooring chain of a floating type offshore structure. BSI(British Standard Institution) flaw assessment procedure BS7910 was combined with first- and second-order reliability method (FORM, SORM) so that the acceptance of a given flaw can be assessed considering the uncertainties of parameters that play important role in the flaw assessment. Considering the probabilistic nature of the crack size and long-term distribution of the stresses acting on the crack in mooring chain, the failure probability was calculated using FORM and SORM. To check the validity of the FORM and SORM, Monte Carlo simulation was also carried out to derive the true limit state function and compared with the results of FORM and SORM.

Development of Korean Osteoarthritis Impact Measurement Scale(KAIMS) : from data collection to item development in the first study (한국형 골관절염영향측정도구 개발 - 자료수집에서 1차 문항개발까지 -)

  • Yi, Seung-Ju;Kim, Yeon-Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose : The aim of this study was from data collection to item development in the first study before developing a valid and reliable instrument reflecting Korean's own language expression and culture. Methods : The fist survey was 140 osteoarthritis(OA) patients in 2 Cites was studied from November to December 2009. Open-ended questionnaire was decided 39 items from the first open survey. Questionnaire on the Korean Osteoarthritis Impact Measurement Scale(KAIMS) was recruited 2 professors and 5 physical therapists. Second survey was applied to 133 OA patients. Results : OA patients's average age${\pm}$standard deviation was $66.08{\pm}11.10$ years. The internal consistency reliability of 3 items. As estimated by Cronbach's alpha coefficient(${\alpha}$), was high(range, 0.86~0.96). 0.43~0.91 ${\alpha}$ coefficient for the internal consistency reliability of item-each scale was also high. However, item-discriminant validity on 3 items was low(${\alpha}$, 0.92~0.97). The construct validity by factor analysis was a little low. Conclusion : This study revealed that we confirmed a generation for 39 items on KAIMS reflecting Korean's own language expression and culture. Also, those of reliability were a little high. And, we will have to study the last instrument development (3rd study) by more subjects in the future.

  • PDF

Investigation of Various Reliability Indices of Pre-service Mathematics Teachers' Teaching Aptitude and Personality Test based on Setting Cut Scores (예비수학교사의 교직 적성·인성 검사에서 분할점수 변화에 따른 다양한 신뢰도 탐색)

  • Kim, Sungyeun
    • The Mathematical Education
    • /
    • v.57 no.1
    • /
    • pp.55-74
    • /
    • 2018
  • The purpose of this study is first to examine the relative influence of each error source and to investigate the optimal measurement conditions to ensure satisfactory multiple reliability coefficients based on the teaching aptitude and personality test for pre-service teachers. Participants were 33 students enrolled in mathematics education in a graduate school of education located in the Seoul metropolitan area from 2013 to 2017. The main results were as follows. First, the estimated variance due to residual was highest, followed by nesting of items within domains, graduate students, interactions of graduate students with domains, and domains. Second, total 96 items, with 12 domains containing 8 items in each domain, with cut score of 598, and original 210 items, with 14 domains containing 15 items in each domain, with cut scores of 615 or 716 were optimal measurement conditions to reach acceptable reliability levels based on the joint consideration of dependability coefficients, cut score dependability coefficients, adjusted dependability coefficients, and standard errors of measurement. Third, larger deviations between the arithmetic mean and the cut score indicated higher reliability coefficients of the test results. Finally, this study suggests ways for practitioners to consider how to apply generalizability theory for criterion-referenced tests and how to develop future research based on limitations.

The Korean language version of Stroke Impact Scale 3.0: Cross-cultural adaptation and translation

  • Lee, Hae-jung;Song, Ju-min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.3
    • /
    • pp.47-55
    • /
    • 2015
  • PURPOSE: Stoke is one of most common disabling conditions and it is still lacking of measuring patient's functioning level. The aim of the study was to develop Korean language version of stroke impact scale 3.0. METHODS: Korean version of stroke impact scale 3.0 was developed in idiomatic modern Korean with a standard protocol of multiple forward and backward translations and an expert reviews to achieve equivalence with the original English version. Interviews with clinicians who were currently managing patients with stroke were also conducted for language evaluation. A reliability test was performed to make final adaptation using a pre-final version. To assess the reliability of the translated questionnaire, the intraclass correlation coefficient (ICC) was calculated for each domain of the scale. RESULTS: Thirty subjects (16 male, 14 female) aged from 20 to 75 years old participated to review the translated questionnaire. Reliability of each domain of the questionnaire was found to be good in strength (ICC=0.74), ADL (ICC=0.81), mobility (ICC=0.90), hand function (ICC=0.80) and social participation (ICC=0.79), communication (ICC=0.77) with total (ICC=0.76). However, domains of memory and thinking (ICC=0.66), and emotion (ICC=0.27) and showed poor reliability. CONCLUSION: This study indicates that the Korean version of SIS 3.0 was successfully developed. Future study needed for obtaining the validity of the Korean version of SIS 3.0.

Accuracy and reliability evaluation of basic CPR application information developed in Korean (국문으로 개발된 기본심폐소생술 애플리케이션 정보의 정확성과 신뢰성 평가)

  • Jung, Eun-Kyung;Kang, Ji-Hun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.3
    • /
    • pp.41-51
    • /
    • 2019
  • Purpose: This dissertation is a descriptive research study analyzing the accuracy and reliability of the cardiopulmonary resuscitation (CPR) application developed in Korea. Methods: Two faculty members from the emergency medical services department and the emergency medicine department searched applications from July 1 to July 10, 2019 and selected a total of 13 applications. Twelve questions were assessed for information accuracy and three were assessed for reliability. In accordance with application types, the number and mean ± standard deviation were analyzed. The t-test was used to compare the accuracy of CPR information in accordance with information sources. Results: The results revealed the following errors: 7 cases (53.8%) identified the chest center lining from the nipple center-line as the chest pressure point; 5 cases (38.5%) did not provide information on the depth of 6 cm that should not be exceeded; and 4 cases (30.8%) did not provide advise to check respiration. When the CPR information sources were included, the information accuracy score was high; a significant difference was observed (p=.035). Conclusion: In the case of applications providing medical information regarding CPR, it is necessary to provide at least authoritarian, sources of information, and author transparency as well as continuous effort and attention.

Reliability testing of InGaAs Waveguide Photodiodes for 40-Gbps Optical Receiver Applications (40-Gbps급 InGaAs 도파로형 포토다이오드의 신뢰성 실험)

  • Joo, Han-Sung;Ko, Young-Don;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.13-16
    • /
    • 2004
  • The reliability of 1.550m-wavelength InGaAs mesa waveguide photodiodes(WGPDs), which developed for 40-Gbps optical receiver applications, fabricated by metal organic chemical vapor deposition is investigated. Reliability is examined by both high-temperature storage tests and the accelerated life tests by monitoring dark current and breakdown voltage. The median device lifetime and the activation energy of the degradation mechanism are computed for WGPD test structures. From the accelerated life test results, the activation energy of the degradation mechanism and median lifetime of these devices in room temperature are extracted from the log-normal failure model by using average lifetime and the standard deviation of that lifetime in each test temperature. It is found that the WGPD structure yields devices with the median lifetime of much longer than $10^6$ h at practical use conditions. Consequently, this WGPD structure has sufficient characteristics for practical 40-Gbps optical receiver modules.

  • PDF

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.3
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

The Effect of Rapport on the Airplane on Reliability and Safety - Under the Pandemic - (기내에서의 라포가 신뢰성과 안전성에 미치는 영향 - 팬데믹 상황을 기반으로 -)

  • Kim, Kyoung Eun;Jeon, Seung Joon;Jung, Yun Sick
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.30 no.3
    • /
    • pp.65-75
    • /
    • 2022
  • This study tried to confirm whether the public's negative emotions such as fear and anxiety about corona virus infection caused by the spatial nature of the aircraft were alleviated due to factors of in-flight services focusing on hygiene and quarantine and further had a positive effect on the formation of Rapport between cabin crews and passengers. We also investigated the impact on passengers' perceptions such as Reliability and Safety which can be viewed as a new measure and standard of customer satisfaction in the Pandemic era through Rapport. A survey was conducted online in December 2021 for passengers with experience in boarding aircraft after the COVID-19 outbreak, and a total of 211 responses were used for analysis. As a result of the analysis of the data, it was confirmed that aircraft in-flight service had a positive (+) effect on Rapport, and Rapport between passengers and cabin crews had a positive (+) effect on passenger Reliability and Safety.

A Coexistence Mitigation Scheme in IEEE 802.15.4-based WBAN (IEEE 802.15.4 기반 WBAN의 공존 문제 완화 기법)

  • Choi, Jong-hyeon;Kim, Byoung-seon;Cho, Jin-sung
    • Journal of Internet Computing and Services
    • /
    • v.16 no.3
    • /
    • pp.1-11
    • /
    • 2015
  • WBAN(Wireless Body Area Network) operating around the human body aims at medical and non-medical service at the same time. and it is the short-range communication technology requiring low-power, various data rate and high reliability. Various studies is performing for IEEE 802.15.4, because IEEE 802.15.4 can provide high compatibility for operate WBAN among communication standard satisfiable these requirements. Meanwhile, in the case of coexisting many IEEE 802.15.4-based WBAN, signal interference and collision are the main cause that is decreasing data reliability. but IEEE 802.15.4 Standard does not consider about coexistence of many networks. so it needs improvement. In this paper, To solve about this problem, identify coexistence problem of IEEE 802.15.4-based WBAN by preliminary experiments. and propose a scheme to mitigate the reliability decrease at multiple coexistence WBAN. The proposed scheme can be classified in two steps. The first step is avoidance to collision on the CFP through improving data transmission. The second step is mitigation collision through converting channel access method. Proposed scheme is verified the performance by performing comparison experiment with Standard-based WBAN.

Reassessment of Validity and Reliability of the Tools for Measuring Yangseng -Focused on the Elderly People in Jeonbuk Area- (양생측정도구의 타당도와 신뢰도 재검증 -전북지역 노인을 중심으로-)

  • Jung, Hae-Kyoung;Kwon, So-Hee;Kim, Ae-Jung;Wang, Myoung-Ja;Lee, Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.9 no.1
    • /
    • pp.17-36
    • /
    • 2005
  • The objective of this study is to present basic data for producing tools to measure Yangseng of the elderly aged older than 65 by reassessing the validity and reliability of such tools already developed. In the present study, total 855 subjects were divided into 4 groups and given 31 question for the ultimate factor analysis of each item. The results cloud be summarized as follows: 1. In case of 'don't have sex in drunken state or right after dinner'(the 31st item of sex live yangseng). factor loading came out proportionally in 3 factors such as factor 4=0.358, factor 5=0.389 and factor 6=0.386. As they all failed to reach the general standard of 0.5 or more and even the minimum standard of 0.4 or more, the 31st item was deleted from the questionnaires. 2. From the factor analysis after exclusion of the 31st item, factor loading of the 25th item of sleep yangseng 'go to bed and get up regularly' appeared to be proportional in 2 factor(factor 4=0.393 and factor 7=0.373). Since it was shown that the 25th item could not be classified into a category but interacted with others in common and didn't satisfy the minimum standard of 0.4, it was deleted form the questionnaires, too. 3. From the factor analysis conducted after excluding the item numbers 31 and 25, factor loading of the 12th item of diet yangseng 'do not eat much' turned out to be relatively high with such values as factor 5=0.518 and factor 3=0.453. As it was, however, tied up with the factor of exercise yangseng, it was also deleted. In conclusion, 28 items after excluding the item numbers 12, 25 and 31 form 4 group showed the same results as divided into 8 factor with high grade of reliability and validity, evidencing the assumption that they can be employed practically to measure yangseng of the elderly aged 65 and oder.

  • PDF