• Title/Summary/Keyword: Reliability standard

Search Result 1,701, Processing Time 0.033 seconds

An Anatomic Study and Clinical Application of Medial Plantar Septo-cutaneous Flap (내족저변 격막 피판의 해부학적 고찰 및 임상적 적용)

  • Yoon, Eul-Sik;Kim, Jung-Bae;Kae, Min-Seok;Dhong, Eun-Sang;Han, Seung-Kyu;Lee, Byung-Il;Koo, Sang-Hwan;Park, Seung-Ha;Kim, Woo-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.1
    • /
    • pp.53-62
    • /
    • 2002
  • Several investigators have reported clinical experience of medial plantar septo-cutaneous flap for reconstruction for soft tissue defect of the hand and digits. Jayme and Hamilton first described the anatomy of superficial branch of medial division of the medial plantar artery used in this flap through cadavaric study in 1997. But, they had a few cases for this flap and there was no anatomic study in Korean. We experienced the reliability of medial plantar septo-cutaneous flap for reconstruction for soft tissue defect of hand and digits through an anatomic study (20 fresh specimens dissected) and clinical application (17 patients). An anatomic study revealed that there were differences in diameter and length of the vessels between Korean and Caucasian. The diameter of vessels in Korean is larger than Caucasian one in each area. Based on this anatomic knowledge, we could harvest this flap safely, and have performed reconstruction on 17 patients with soft tissue defects of hand and digits using a thin, flexible medial plantar septo-cutaneous flap similar to the volar aspect of the hand and digits in anatomical characteristics of the skin and subcutaneous tissue covering. The vessels used for this flap were superficial branches of medial division of the medial plantar artery and vena comitants, or the subcutaneous veins. The mean size of the flap was $2.82cm{\times}4.15cm$. All the flaps survived without significant complications. A medial plantar septo-cutaneous flap possesses several advantages : (1) It is very thin in comparison with other standard free flap; (2) it has two draining venous pathways; (3) it provides a good color and texture match for hand and finger; (4) a good recovery of protective sensation is achievable.

  • PDF

The Study of Fast X-ray Fluorescence Analysis Using a SSQ Program (SSQ 프로그램을 이용한 빠른 X-선형광분석법 고찰)

  • Park, Yong Joon
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.112-119
    • /
    • 1998
  • A Siemens SemiQuant (SSQ) 3000 program, a precalibrated 'standardless' analytical program handling up to 90 elements, was evaluated for the fast analysis of various types of reference materials using a wavelength dispersive X-ray spectrometer. Various types of standard reference materials such as metal discs, metal chips, and geological materials in powder form were analysed and it took 23 minutes of measuring time for 75 elements. Measurements of geological reference materials using different sampling methods were carried out and their data were interactively evaluated. The analysis of materials of a known matrix concentration such as stainless steels provided higher precision value compared to totally unknown samples. The analyses of materials prepared as pressed pellets or fused glass beads provided higher precision values compared to the measurement of loose powders with a foil on the sample surface and helium operation, though their sampling procedures were more complicate and took more time. Since very light elements such as boron, carbon, and oxygen have a strong influence on the matrix effects and also on the calculation of effective matrix corrections, the rhodium Compton check was applied to verify the reliability of the defined light element concentrations of light matrix materials and the defined major sample compounds. Failure of defining correct matrix resulted in an unoptimized matrix correction and therefore in the wrong calculation of the element concentration.

  • PDF

Changes in Figures of FSH and E2 while Breast Cancer Patients Treated with Surgery takes Tamoxifen (유방암 수술환자가 Tamoxifen복용기간 중 발생하는 FSH와 E2의 수치 변화)

  • Kwon, Won-Hyun;Moon, Ki-Choon;Kim, Hye-Sook;Lee, In-Won;Shin, Suk-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.186-189
    • /
    • 2010
  • Purpose: As many patients often showed the value of menopause although they were women of childbearing age, this study looked into their previous history. According to the findings, they were patients with a mastectomy due to breast cancer and were taking breast cancer treatment Tamoxifen (the women hormone inhibitor) after chemotherapy. This study is conducted to examine changes in FSH and E2 concentration of patients breast cancer patients of childbearing age according to Tamoxifen used to prevent recurrence of breast cancer and proliferation of mammary parenchyma. Materials and Methods: This study aims to investigate similarity in patients treated with surgery who were in their childbearing age and in values of FSH and E2 by dividing test results of FSH and E2 requested at the department of nuclear medicine among patients who visited this hospital from Jan. 2009 to Mar. 2010 into women of childbearing age (n=50), menopausal women (n=50), and patients with breast cancer surgery who take Tamoxifen (n=50) and then comparing the test results. Results: The FSH and E2 test results of 50 patients were compared and analyzed as average${\pm}$standard deviation, and the results showed that the figure of women of childbearingage (n=50) was FSH : $7.14{\pm}6.19$, E2 : $138.76{\pm}85.40$, that of menopausal women (n=50) was FSH : $52.12{\pm}24.43$, E2 : $15.06{\pm}4.43$, and that of patients with breast cancer surgery who were in their childbearing age (n=50) was FSH : $44.21{\pm}21.07$, E2 : $13.53{\pm}4.26$. When these different results of FSH and E2 were compared, the value of patients with breast cancer surgery who were in their childbearing age with Tamoxifen was somewhat similar to that of menopausal women. Conclusion: The test results of FSH and E2 have reportedly found the test values of patients with breast cancer surgery could be similar to that of menopausal women eventhough they were in their childbearing age due to the women hormone inhibitor Tamoxifen. Therefore, if a tester conducts this experiment after understanding the clinical meaning, the reliability of the tester reporting test results would be increased.

  • PDF

A Sensitivity Analysis of Design Parameters of an Underground Radioactive Waste Repository Using a Backpropagation Neural Network (Backpropagation 인공신경망을 이용한 지하 방사성폐기물 처분장 설계 인자의 민감도 분석)

  • Kwon, S.;Cho, W.J.
    • Tunnel and Underground Space
    • /
    • v.19 no.3
    • /
    • pp.203-212
    • /
    • 2009
  • The prediction of near field behavior around an underground high-level radioactive waste repository is important for the repository design as well as the safety assessment. In this study, a sensitivity analysis for seven parameters consisted of design parameters and material properties was carried out using a three-dimensional finite difference code. From the sensitivity analysis, it was found that the effects of borehole spacing, tunnel spacing, cooling time and rock thermal conductivity were more significant than the other parameters. For getting a statistical distribution of buffer and rock temperatures around the repository, an artificial neural network, backpropagation, was applied. The reliability of the trained neural network was tested with the cases with randomly chosen input parameters. When the parameter variation is within ${\pm}10%$, the prediction from the network was found to be reliable with about a 1% error. It was possible to calculate the temperature distribution for many cases quickly with the trained neural network. The buffer and rock temperatures showed a normal distribution with means of $98^{\circ}C$ and $83.9^{\circ}C$ standard deviations of $3.82^{\circ}C$ and $3.67^{\circ}C$, respectively. Using the neural network, it was also possible to estimate the required change in design parameters for reducing the buffer and rock temperatures for $1^{\circ}C$.

Analysis of the Delineation Accuracy of Vegetation Type for the Information Reliability of the Biotope - Case Study of Seoul Biotope Map - (비오톱지도 신뢰도 판단을 위한 식생유형 공간구획의 정확성 고찰)

  • Cho, Woo;Hong, Suk-Hwan;Kwark, Jeong-In;Han, Bong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.5
    • /
    • pp.575-581
    • /
    • 2010
  • This study was accomplished for verifying the biotope field survey accuracy in the forests. Biotope data is used as the standard for the preservation and restoration of the urban ecosystem. The study area is the forests of Gwanak-gu, Seoul. For verifying accuracy, first we compared biotope field survey results between 2000 and 2005, second we compared between field survey results and satellite imagery. For comparing with satellite imagery, we delineated the evergreen-coniferous forests from imagery taken during winter season. As a result of comparison, the ratio of most actual vegetation types by delineated detail field surveys were matched around 92% between 2000 and 2005. But, between 2 field surveys, around 60% of total vegetation type was regionally matched. Evergreen-coniferous forests extracted by satellite imagery were regionally matched 69.4% of field survey result in 2000, and matched 80% of the result in 2005. If we consider the delineating errors from deciphering the picture, the results have high accuracy, especially 2005. The processes of verifying accuracy have not been proceeding in the part of delineating actual vegetation works. The verification of accuracy is important for the renewal process. Thus, the various verification methods will be studied and criteria should be developed for enhancing objectivity.

Development of Eyes Inspection Questionnaire(EIQ) and Regression Analysis between EIQ Items and deficiency or excess patterns of Eyes Inspection (안진(眼診) 설문지 개발 및 안진(眼診) 설문의 허실(虛實) 연관성 연구)

  • Seo, Jae-Ho;Choi, Jin-Yong;Oh, Whan-Sup;Park, Young-Bae;Park, Young-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.2
    • /
    • pp.75-84
    • /
    • 2014
  • Objectives Eyes, one of visual inspection regions, present important clues to pathological patterns including deficiency and excess patterns to the clinicians. The purpose of this study was to develop Eyes Inspection Questionnaire (EIQ) and to examine which items among the EIQ were more predictive of clinicians' determination for the deficiency and excess patterns. Methods Nine questionnaire items for Visual Inspection of Eyes were extracted through the literature review. These items were presented to the 4 Korean medical doctors who are specialized in visual inspection to conduct the Delphi method. The Korean medical doctors were asked to rate the importance of each items for the corresponding Visual Inspection of Eyes, using a Likert 5-point scale(the 3 points of importance as a cut-off point). Then, out of 75 photographs submitted to the Society of HyungSang Medicine in 2009, 30 portrait pictures were selected as samples. The samples were copied to make 60 sample pictures, and then randomly assigned to 4 clinicians. The 4 clinicians evaluated the 60 samples for excess and deficiency of the eyes and were asked to check the 6 questionnaire items. The results were recorded as 5-points-scale, and their average and standard deviations were calculated. Intra- class reliability test and multi regression test were performed using SPSS 13. Results Intra-class correlation coefficient (ICC) was between 0.750 to 0.841 (P<0.05). Indices for visual inspection of the eyes were: endowment of the bone structure around the eyes; brightness of the eyes; upward deviation of the eyes; eye shapes; and definition of iris. 76.92% of deficiency symptom patterns and 86.42% of the excess symptom patterns matched the patterns predicted by the visual inspection of the eyes, according to the frequency analysis. According to the multiple regression analysis, were significantly related to the excessive symptoms, and to the deficiency symptoms. Conclusion This study is the first attempt of development for checklist of excess and deficiency of Visual Inspection of Eyes and quantitative measurement of excess and deficiency using the Visual Inspection of Eyes by the visual inspection experts. Still, additional studies are needed regarding the relationship visual inspection methods have with existing standards of diagnosis.

An Establishment of Functional Test Facility for ICT-Convergence Equipment of Vessel : Focused on Maritime Digital Interfaces and Main Navigation Communication Systems (선박 ICT융합 장비 기능시험 시설 구축 연구 : 선박 디지털 인터페이스 및 주요 항해통신장비를 중심으로)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Woo, Snag-Min;Woo, Yun-Tae;Shin, Il-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.5
    • /
    • pp.754-763
    • /
    • 2018
  • The maritime ICT-convergence equipment are essentially required to a type approval (TA) certification that needs environmental and functional tests, to install in vessel. The environmental test is to experiment the possession for required durabilities of the target device in maritime environment, and the functional test is to check the required functions of target equipment based on international standard. In Korea, the environmental testing facilities amount to 227 sites, but there is no functional testing facility. Because of this, we establish a function test facility for the maritime ICT-equipment. In this paper, we analyze and design the functional testing requirement and required interlocking simulators for digital interfaces and navigation communication equipment. We propose the 2-steps of functional testing procedures, which are single test and integration test, to improve the reliability of testing result. The single test is to examine own functions of the target device, and the integration test is to check harmonized operation with other navigation and communication devices.

A Validation Study on the Reinforcement Effect of Reservoir Grouting by Surface Wave Survey (표면파탐사를 이용한 저수지 제체 그라우팅 보강효과 검증 연구)

  • Bae, Hyungseop;Lee, Yeong-Dong;Won, Kyoung-Sik
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.297-312
    • /
    • 2018
  • In order to assess the safety diagnosis and grouting reinforcement effect of old reservoir facility, local governments and public offices mainly use electrical resistivity survey. However, electrical resistivity survey is a qualitative evaluation that varies the resistivity value by various exploration conditions. It is also difficult to grasp the stiffness change directly related to the stability of reservoir, thus an electrical resistivity survey is not applicable to continuous stability monitoring after grouting. The purpose of this study is to investigate and validate the quantitative evaluation of reinforcement effect of reservoir with cement grouting through shear velocity (Vs), which is closely related to the stiffness (${\mu}$) of the ground. This study was carried out on two reservoir facilities. The reinforcement effect was evaluated by comparing the permeability test, standard penetration test, down-hole test and MASW(Multi-channel Analysis of Surface wave) survey before and after cement grouting. Shear wave velocity changes before and after grouting were analyzed by phase velocity difference and inversion analysis, respectively, and the reliability of the analytical results was evaluated by comparing with field test results. Shear wave velocity increases to 5~10% in case of the D levee, and 10~20% in the levee of H reservoir. These results are showed similar pattern to the field test results.

Failure Analysis by Fracture Study of Connecting Rod Bolts in Diesel Engine for Military Tracked Vehicles (군용 궤도차량 디젤엔진의 커넥팅 로드 볼트 파손 검토를 통한 고장원인분석)

  • Oh, Dae San;Kim, Ji Hoon;Seo, Suk Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.191-200
    • /
    • 2020
  • Tracked military vehicles are operated under harsher conditions and climates than ordinary vehicles, and the components require high degrees of reliability and durability. A diesel engine is the main power generator, and when the vehicle breaks down, there is a high possibility of causing a large-scale accident. Therefore, analyzing the cause of engine failure can be important for preventing similar cases that may occur. In this study, we clarified the mechanism of engine failure according to an overhaul test, hardness measurement, and an analysis of the fracture surface. The overhaul test confirmed that a bolt was separated from the connecting rod (number 4). In addition, the hardness measurement results of the connecting rod bolt conformed to the standard, and it was found that the bolt fracture was ductile fracture through an analysis of the fracture surface. Based on the results, it was concluded that damage to a diesel engine of a tracked military vehicle was caused by separating and damage caused by loosening of the connecting rod bolts, resulting in cascading damage. The results of the study could be used as reference examples and could be useful for another study on engine failure analysis.

Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers

  • Lee, Y.;Bok, J.D.;Lee, H.J.;Lee, H.G.;Kim, D.;Lee, I.;Kang, S.K.;Choi, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.2
    • /
    • pp.299-306
    • /
    • 2016
  • Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean${\pm}$standard deviation [SD], $37.1^{\circ}C$ to $37.36^{\circ}C{\pm}0.91^{\circ}C$ to $1.02^{\circ}C$). STs are $1.39^{\circ}C$ to $1.65^{\circ}C$ lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below $36.5^{\circ}C$ or $37^{\circ}C$, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below $36.5^{\circ}C$ or $37^{\circ}C$ resulting in a much improved mean${\pm}$SD of $37.6^{\circ}C{\pm}0.64^{\circ}C$ or $37.8^{\circ}C{\pm}0.55^{\circ}C$, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck.