• 제목/요약/키워드: Reliability Measurement Tool

검색결과 326건 처리시간 0.029초

권역심뇌혈관질환센터의 공익성 측정도구 개발 (Development and Validation of the Measurement Tool of Public Benefits in Regional Cardiocerebrovascular Center)

  • 이건세;신은영;정효선;이정현;김희숙;임영실;김영택Kun
    • 보건행정학회지
    • /
    • 제23권4호
    • /
    • pp.434-444
    • /
    • 2013
  • Background: Regional Cardiocerebrovascular Centers (RCC) were established for the prevention and treatment of cardiocerebrovascular disease and funded by the Ministry of Health and Welfare. The purpose of this study was to develop and validate the measurement tool of public benefits in RCC. Methods: Through the intensive literature review, experts surveys and their repetitive feedback, we selected the 46 items about the public benefits in RCC. Development of measurement tool involved content validity test using Content Validity Index (CVI), construct validity test through factor analysis and reliability test. Results: Thirty-five items were selected by content validity test, which CVI was 0.08 or higher. Through the construct validity test, 32 items in 7 factors were derived. And Cronbach's alpha was 0.951. Finally, public benefits measurement tool is composed of 32 items in 7 factors which are comprehensiveness of health care services, market complement, emergency care, cost, governance, quality improvement, and government control. Conclusion: Though we developed the measurement tool of public benefits in RCC, it would be utilized to measure the public benefits of various health agencies.

디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석 (Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer)

  • 장우남;이경보;염준우;황병용
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.

A Study on Development of the Digital Competence Measurement Tool for University Student

  • Kim, Dong-Man;Lee, Tae-Wuk
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권12호
    • /
    • pp.191-199
    • /
    • 2019
  • 이 논문의 목적은 대학생의 디지털 역량을 진단하기 위한 검사 도구를 개발하는 것이다. 이를 위해 디지털 역량 관련 선행연구를 고찰하고 내용 요소를 선정하여 6개 영역, 40개 문항의 1차 검사 도구를 개발하였다. 이후 223명의 대학생을 대상으로 설문 조사하고, 요인분석을 통해 디지털 역량을 측정하기 위한 요소와 문항을 정제하였다. 그리고 확인적 요인분석을 통해 모형적합도를 통계적으로 만족시킨 6개 요인, 18개 문항으로 구성된 대학생 디지털 역량 검사 도구를 최종적으로 확정하였다. 이 연구에서 개발한 대학생용 디지털 역량 검사 도구는 디지털 기기 운용, 소통 및 협업, 정보 검색·처리·관리, 문제 해결 및 학습, 보안, 디지털 윤리 등과 같은 6가지 하위 구성요소로 구성되었다. 이렇게 개발된 검사 도구는 집중 타당도와 판별 타당도가 높아 대학생의 디지털 역량을 측정하는데 적합한 검사 도구임을 확인하였다. 이 연구에서 개발된 디지털 역량 검사 도구는 대학생의 현재 역량 수준을 파악하고 교육적 지원을 통해 학생들의 디지털 역량을 향상하는데 활용될 것으로 기대한다.

어린이 급식소 위생·안전관리 수행 도구 개발 (Developing A Tool to Execute Children's Food Service Hygiene and Safety Management)

  • 이진용
    • 한국식품영양학회지
    • /
    • 제29권2호
    • /
    • pp.253-266
    • /
    • 2016
  • The current study was conducted to facilitate appropriate hygiene and safety management in children's food service stations, with the ultimate objective of providing sanitary and safe food service to children. In order to develop questionnaire items, literature review was conducted, in addition to detailed interview of working-level personnel at a children's food service management support center. This resulted in a total of thirty questions on personal hygiene management, food materials hygiene management, and facilities hygiene management. Using the questionnaire, seventy-one food service stations for children in District A in Seoul that serve less than one hundred children were surveyed to analyze the reliability, construct validity, and correlation in the developed measurement tool. The developed measurement tool consisted of ten task and environmental hygiene management questions, five personal and cooking hygiene management questions, four food ingredient and storage hygiene management questions, and four food service operation and management question; with a total of twenty-three questions, in four factors stated above. The cumulative distribution of the four factors was 54.698%, and Cronbach's ${\alpha}$ value was 0.672~0.853, which indicated that the study was reliable. The results of the analysis indicated that each of the factors were correlated, the study was satisfactory, and the tool was valid for evaluating hygiene and safety management practices in children's food service stations. Finally, in order to enhance practical utility of the developed measurement tool, the significance and limitations were described.

Reliability and validity of pelvic mobility measurement using a cushion sensor in healthy adults

  • Jung, Seung-Hwa;Kim, Su-Kyeong;Lee, Ji-Hyun;Choi, Soo-Ih;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권2호
    • /
    • pp.74-81
    • /
    • 2020
  • Objective: To prevent low back pain, an objective evaluation tool to evaluate pelvic mobility and exercise to improve the flexibility of the lumbar region is needed. The purpose of this study was to compare the results of pelvic mobility measurements using the Wii Balance Board (WBB) and Sensbalance Therapy Cushion (STC), evaluate the usefulness of the STC as a tool for measuring pelvic mobility. Design: Cross-sectional study. Methods: Fifty healthy subjects participated in this study. The subjects performed pelvic mobility range, proprioception, reaction time and reach of the arm using the STC. The pelvic movement parameter was measured two times to determine the intra-rater reliability. To measure the correlation between lumbar muscle tension and pelvic mobility, Myovision was used to measure tension of L4, L5 level erector spinae muscle. Correlations between measured variables were checked to determine the validity of the pelvic mobility assessment tool. Results: STC showed high test-retest reliability in pelvic tilt measurement and reaching task [intraclass correlation coefficients (3,1)=0.804-0.915]. The relationship between WBB and STC showed a significant positive correlation with the pelvic tilt and reaching task (p<0.05). Posterior tilt and erector spinae activation (Lt. L5) showed a significant negative correlation (p<0.05). Left, right tilt and erector spinae activation (L5) showed a significant negative correlation (p<0.05). Conclusions: This study confirmed the advantages of the STC and found efficiency as an objective measuring device of pelvic mobility.

두통 평가 척도에 관한 고찰 - 신뢰도와 타당도를 중심으로 - (Review Study of Headache Measurement Tools - Mainly on Reliability and Validity -)

  • 김은정;정찬영;장민기;윤은혜;남동우;강중원;이재동;이승덕;김갑성
    • Journal of Acupuncture Research
    • /
    • 제27권1호
    • /
    • pp.51-64
    • /
    • 2010
  • Objectives : To introduce and compare various headache measurement tools, in order to provide fundamental information for future clinical trials and development of oriental medicine measurement tools. Methods : Eight headache assessment scales, Migraine-Specific Quality of Life Questionnaire(MQoLQ), Migraine-Specific Quality of Life(MSQOL), Migraine-Specific Quality of Life Questionnaire(MSQ), The Headache Impact Questionnaire(HImQ), Headcahe Needs Assessment Survey(HANA), Henry Ford Headache disability Inventory(HDI), Migraine Disablity Assessment Scale(MIDAS) and Headache Impact Test(HIT-6), were searched through Pubmed. General character, the process of development, verification of reliability, internal consistency, responsiveness to patient's change and validity were reviewed. Results : In assessing the quality of life of migraine patients, MQoLQ can be used to measure the change within 24 hours, MSQ and MSQOL can be used to measure the change during a relatively longer period of time. The frequency and bothersomeness of headache can be easily measured by HANA. HImQ can be used to measure the intensity of headache and the influence on normal daily activities. HDI can measure the emotional difficulties of headache patients. HIT-6 and MIDAS makes measurements possible in a short period of time, and the reliability and validity have been verified numerously. HIT-6 and MIDAS are the most frequently used measurement tools because they are simple and easy for both the assessor and the patient to understand and use. Conclusions : In this study, various headache assessment tools have been reviewed. The assessed tools were widely used after being verified for their reliability and validity. We hope this study provides fundamental information in establishing future clinical trial and clinical practice guidelines. We also hope this study to contribute to the development of an oriental medicine assessment tool for headache.

학교보안관의 직무수행 척도 개발 (Development of Measurement Scale for School Police's Job Performance)

  • 김경식;김은정
    • 한국콘텐츠학회논문지
    • /
    • 제12권7호
    • /
    • pp.394-405
    • /
    • 2012
  • 이 연구는 학교보안관의 직무수행 측정도구를 개발하여 타당도와 신뢰도를 검증하는데 목적이 있다. 이 연구는 2011년 서울소재 학교보안관이 근무하고 있는 초등학교 학부모들을 대상으로 유의표집법을 활용하여 250명의 연구대상을 표집 하였다. 그러나 응답이 불성실한 자료를 제외하고 최종분석에 사용된 사례수는 총 210명이었다. 학교보안관의 직무수행 측정도구는 문헌고찰, 개념적 정의 및 설문지 초안 작성, 전문가 회의, 예비검사 및 본 조사, 설문지의 타당도 및 신뢰도 검증 등의 과정을 거처 개발되었다. 통계처리는 SPSSWIN 18.0을 활용하여 탐색적 요인분석, 확인적 요인분석, 신뢰도분석, 상관분석 등을 실시하였다. 이상과 같은 연구방법 및 절차를 통하여 이 연구에서는 다음과 같은 결론을 도출하였다. 첫째, 학교보안관의 직무수행 측정도구에 대한 타당도는 매우 높다. 즉, 학교보안관의 직무수행은 전문성, 태도, 프로그램, 학교폭력예방 활동, 효과, 기본 직무, 등하교지도와 관계자연계성으로 탐색 확인되었으며, 태도의 설명력이 가장 높다. 둘째, 학교보안관의 직무수행 측정도구에 대한 신뢰도는 매우 높다. 즉, 학교보안관의 직무수행은 문항과 영역간, 문항과 총점간 상관정도가 높으며, 내적일관성 신뢰도인 Cronbach's ${\alpha}$값이 .708이상이다. 종합해 보면, 학교보안관의 직무수행 측정도구는 타당도 및 신뢰도가 높은 설문지임을 알 수 있다.

Reliability and Concurrent Validity of Korean Version of the Trunk Control Measurement Scale (K-TCMS) for Children with Cerebral Palsy

  • Ko, Jooyeon;Jung, Jeewoon
    • The Journal of Korean Physical Therapy
    • /
    • 제29권1호
    • /
    • pp.16-26
    • /
    • 2017
  • Purpose: This study was conducted to develop a Korean version of the trunk control measurement scale (TCMS) and examine the reliability and concurrent validity of the K-TCMS in children with cerebral palsy. Methods: Subjects for the study were 23 children with cerebral palsy (CP)(mean age: 84.70 months) recruited from one CP clinic. For the interrater and test-retest reliabilities, four raters (A, B, C, D) measured the K-TCMS two times using video clips with an interval of two weeks. For the concurrent validity, the Korean version of the gross motor function measure (K-GMFM) was chosen. Inter-rater reliability and test-retest reliability of the three K-TCMS subscale (static sitting balance, dynamic sitting balance and dynamic reaching) scores and the total scores were investigated using the intra-correlation coefficient ($ICC_{3,1}$). Spearman's correlation coefficient (r) was calculated to investigate the concurrent validity. Results: The inter-rater reliability of the K-TCMS subscales and total scores were all high ($ICC_{3,1}=0.968-0.992$). For the test-retest reliability, $ICC_{3,1}=0.827-0.962$. The concurrent validity between the K-TCMS's total and three subscale scores and K-GMFM's total score were r=0.600-0.667. Conclusion: The results suggest that the K-TCMS can be used in clinical and research settings as a standardized tool for CP children. The K-TCMS might be also useful for selecting treatment goals and planning interventions for children with cerebral palsy.

The Reliability of the Pediatric Functional Muscle Testing in Children with Developmental Delay

  • Seo, Hye-Jung;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • 제27권4호
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: The aim of this study was to examine the test-retest and inter-rater reliability of the pediatric functional muscle testing (PFMT) when applied to children with developmental delay. Methods: Sixteen children with developmental delay (seven females, nine males) participated in this study. For the inter-rater reliability, each was scored on the PMFT by two pediatric physical therapists with more than 8 years of clinical experience on the same day. For assessment of the test-retest reliability, one therapist tested the children again within 10 days. The second measurement was performed by taking a first measurement in video. Intraclass correlation coefficient (ICC) was calculated to determine the test-retest and inter-rater reliability of the PFMT, and Chronbach's alpha was used to measure internal consistency. Results: The results of this study were as follows: 1) The test-retest ICC of the score of the infant action month and the right side of the PFMT was from 0.53 to 1.00 and from 0.63 to 0.99, respectively. 2) The inter-rater ICC of the score of the infant action month and the right side of the PFMT was from 0.66 to 1.00 and from 0.64 to 1.00, respectively. 3) Chronbach's alpha was 0.93. The internal consistency indicated excellent. Conclusion: In conclusion, this study showed that the test-retest and inter-rater reliability of the PFMT was relatively high, except for a few items. Therefore, it can be suggested that the PFMT will be a useful tool for measurement of muscle strength for children with developmental delay if it be some modifications.