• Title/Summary/Keyword: Release Time Test

Search Result 302, Processing Time 0.023 seconds

Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire (구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석)

  • You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.34-39
    • /
    • 2018
  • In this study, the experiment conditions for the variation of heat release rate in compartment space were constructed to analyze the effects of fire spread and the operation time of sprinkler in accordance with the heat loss of the sprinkler's heat element. The compartment composed of fire board (width = 0.3 m, height = 0.5 m, length = 3.0 m), are manufactured to measure the temperature distributions in the inner space, the mass loss rate and heat release rate during the experiment of N-heptane pool fire test. Also, the operation time of sprinkler is analyzed with the installation of sprinkler and C-factor using Fire Dynamics Simulator Ver.6 under the experiment conditions. The results show that the operation time of sprinkler, which has RTI $100(m{\cdot}s)^{0.5}$ operating temperature $70^{\circ}C$, is 30 s~60 s for C-factor = 0 and 1, 62 s~92 s for C-factor = 3, and 120 s over for C-factor = 5, respectively.

Optimum actuator placement for damping of vibrations using the Prestress-Accumulation Release control approach

  • Poplawski, Blazej;Mikulowski, Grzegorz;Pisarski, Dominik;Wiszowaty, Rafal;Jankowski, Lukasz
    • Smart Structures and Systems
    • /
    • v.24 no.1
    • /
    • pp.27-35
    • /
    • 2019
  • This paper proposes a quantitative criterion for optimization of actuator placement for the Prestress-Accumulation Release (PAR) strategy of mitigation of vibrations. The PAR strategy is a recently developed semi-active control approach that relies on controlled redistribution of vibration energy into high-order modes, which are high-frequency and thus effectively dissipated by means of the natural mechanisms of material damping. The energy transfer is achieved by a controlled temporary removal of selected structural constraints. This paper considers a short-time decoupling of rotational degrees of freedom in a frame node so that the bending moments temporarily cease to be transferred between the involved beams. We propose and test a quantitative criterion for placement of such actuators. The criterion is based on local modal strain energy that can be released into high-order modes. The numerical time complexity is linear with respect to the number of actuators and potential placements, which facilitates quick analysis in case of large structures.

Swelling and Proxyphylline Release Kinetics of Enzyme-Digestible Swelling Hydrogel Tablet (효소 소화성 하이드로겔 정제의 팽윤 및 프록시필린 방출 특성)

  • Shim, Chang-Koo;Lee, Young-Mee;Yeo, So-Hyeon
    • YAKHAK HOEJI
    • /
    • v.36 no.3
    • /
    • pp.212-219
    • /
    • 1992
  • Although oral route is the most convenient route for drug administration, the short and variable transit of drug through GI tract restricts the sustained drug absorption after oral administration. Thus, for sustained absorption of drugs, it is desirable to prolong the GI transit time by retaining the dosage forms in the stomach. In this study, the enzyme-digestible swelling hydrogel was synthesized by heating the mixed solution of N-vinyl-2-pyrrolidone[monomer], acrylated albumin[crosslinking agent] and proxyphylline[drug] at $65^{\circ}C$ for 10 hours in the cylindrical test tube. The resultant hydrogel tablet (diameter; 0.77 cm, thickness; 0.47 cm) was designed to swell in the gastric fluid after oral administration to such a size that passing through the pylorus could be inhibited during the drug release. After releasing drug, the hydrogel was expected to be degraded by pepsin, an enzyme in the stomach, and eventually solubilized. Actually, the hydrogel synthesized in the study swelled to a size larger than the diameter of the pylorus ($1.3{\pm}0.7$ cm) and slowly digested in the presence of pepsin. Drug release from the hydrogel was prolonged up to about 12 hours. The swelling kinetics was dependent on albumin acrylation time, drug content and gel thickness. Particularly the gel thickness was the most important factor that influences on drug release. By adjusting these factors, the albumin-crosslinked hydrogel was expected to be retained in the stomach for up to 60 hours and used as a potential platform of drugs for long-term GI absorption.

  • PDF

The Thermal Characteristics of Tree Branches, Barks, Living Leaves and Dead Leaves in Pinus Densiflora and Quercus Dentata (소나무와 떡갈나무의 주요 부위별 열적특성에 관한 연구)

  • Park, Young-Ju;Lee, Si-Young;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.84-92
    • /
    • 2008
  • Disclosed is a study related to the thermal characteristics of Pinus densiflora and Quercus dentate identifying the presence of any significant difference in the above trees, which are native to Young Dong Province of Korea, according to different regions of the trees such as branches, barks, living leaves and dead leaves. For this purpose, we have carried out a cone calorimeter test focusing on the variables such as mass loss, heat release, ignition time, flame holding time and concentrations of CO and $CO_2$. The results showed that the total mass loss was greatest in tree branches, whereas the ignition time of dead leaves was fastest both in Pinus densiflora and Quercus dantata. The flame holding times of dead leaves and barks were about $640{\sim}1,016s$ and the total heat release of dead leaves was around 60.1 $MJ/m^2$, twice the total heat release of living leaves. In addition, the maximum exhaust concentrations of CO and $CO_2$ in tree branches of Quercus dentata was 2.82 times higher than those of Pinus densiflora, respectively. From the foregoing, it was confirmed that there exist region-specific differential thermal characteristics in Pinus densiflora and Quercus dentata.

A Low-Power Single Chip Li-Ion Battery Protection IC

  • Lee, Seunghyeong;Jeong, Yongjae;Song, Yungwi;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.4
    • /
    • pp.445-453
    • /
    • 2015
  • A fully integrated cost-effective and low-power single chip Lithium-Ion (Li-Ion) battery protection IC (BPIC) for portable devices is presented. The control unit of the battery protection system and the MOSFET switches are integrated in a single package to protect the battery from over-charge, over-discharge, and over-current. The proposed BPIC enters into low-power standby mode when the battery becomes over-discharged. A new auto release function (ARF) is adopted to release the BPIC from standby mode and safely return it to normal operation mode. A new delay shorten mode (DSM) is also proposed to reduce the test time without increasing pin counts. The BPIC implemented in a $0.18-{\mu}m$ CMOS process occupies an area of $750{\mu}m{\times}610{\mu}m$. With DSM enabled, the measured test time is dramatically reduced from 56.82 s to 0.15 s. The BPIC chip consumes $3{\mu}A$ under normal operating conditions and $0.45{\mu}A$ under standby mode.

Effect of Fascial Distortion Model on the Pain and Movement of Neck Patient

  • Kim, Min Kyu;Lee, Woo Jin
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.1
    • /
    • pp.24-30
    • /
    • 2019
  • Purpose: This study compared the effectiveness of three methods, fascial distortion model (FDM), myofascial release (MFR), self-myofascial release (SMR), on the neck range of motion and pain. Methods: In this study, the collected data were processed statistically using SPSS version 22.0 for Windows. Descriptive statistics were used to analyze the general characteristics of the subjects. Repeated measure ANOVA was conducted to analyze the range of motion of the neck of the group and VAS, and Contras was used to see the difference in significance over time. One-way ANOVA was used to compare the differences among the groups and a post-hoc test was used. The significance level (${\alpha}$) was 0.05. Results: In the range of motion, the flexion and extension of the neck, right rotation, and left rotation were significantly different in the SMR, FDM, and MFR groups. The right lateral flexion showed significant differences in the FDM, MFR, and SMR groups. The VAS was similar in the groups at 2 and 4 weeks, but there was a significant difference among the FDM, MFR, and SMR groups at 6 weeks. Conclusion: In this study, MFR and MSR as well as FDM were effective in controlling the range of motion and pain control of the neck. Further studies will be needed to determine the effects of long-lasting treatments other than pain control. These studies and the present study will be used as a basis for ongoing research into the duration and method of application for musculoskeletal therapies.

A Study on the Fire Risk of Car Interior Materials (자동차 내장재의 화재위험성에 관한 연구)

  • Lee, Hae-Pyeong;Kim, Young-Tak
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.82-88
    • /
    • 2010
  • In this study, we have performed several tests for composite plastic materials to be applied on interior materials of a vehicle to identify their combustion characteristics using cone calorimeter, smoke density chamber and toxicity index chamber. We have prepared a total of 12 samples for 4 major parts of a vehicle wherein each major part has 3 different materials. The results of cone calorimeter test showed ignition time of PVC sheet and PVC leather were 2s. The 8 samples showed under less than 10s of ignition time. The sample comprising Nylon and PE had the biggest maximum heat release rate of 635 $kW/m^2$. The sample comprising Rubber showed the smallest maximum heat release rate but with the biggest total heat release. The results of smoke density chamber test showed the sample that is made up with Rubber had the biggest specific optical smoke density. The sample comprising PVC leather and PUR showed the biggest VOF4 which enables the initial smoke production. The results of toxicity index test showed that all samples contained carbon dioxide content exceeding its lethal concentration. The sample comprising PVC showed high content of hydrogen chloride and hydrogen bromide. The PVC sheet showed the biggest toxicity index calculated by using lethal concentration and test results. Toxicity index of all sample wes over 1.

Pharmacokinetic Evaluation of Ketorolac Tromethamine Sustained-Release Pellets after Oral Administration in Rabbits (케토롤락트로메타민 서방성 펠렛의 약물속도론적 평가)

  • Kwak, Son-Hyok;Hwang, Sung-Joo;Jiang, Ge;Nam, Kyung-Wan;Moon, Young-Girl;Lee, Hai-Bang;Cho, Sun-Hang;Yuk, Soon-Hong;Lee, Han-Koo;Jeong, Sang-Young;Lee, Young-Won
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.241-246
    • /
    • 2000
  • To develop a sustained-release preparation containing ketorolac tromethamine, two sustained-release pellet formulations were evaluated with a pharmacokinetic study as compared with a conventional commercial tablets (10 mg $Tarasyn^{TM}$, Roche Korea Ltd.). Two sustained-release formulations were as follows; formulation A was composed of an inner layer containing 75% of drug coated with $Eudragit^{TM}$ RS 100 membrane and an outer layer containing 25% of drug mixed with $Eudragit^{TM}$ NE30D, and formulation B was composed of only an inner layer containing 100% of drug coated with $Eudragit^{TM}$ RS 100 membrane. The dissolution test was performed for two formulations. In case of conventional tablets, 2.5 mg of drug per a dose was administered orally into male Albino rabbit (2.0-2.3 kg of body weight) 3 times at intervals of 4 hours. In case of two sustained formulations, 7.5 mg of drug was administered once orally. Blood samples were withdrawn periodically after the administration, and the blood concentration was determined by HPLC. The conventional tablets showed very high peak-trough fluctuation between administered doses, but two sustained formulations showed less fluctuation. Formulation A with the loading dose showed the time to reach minimum effective concentration (MEC) i.e. the onset time was less than 20 min, while Formulation B had more than 1 hr of the onset time. Formulation A had the more constant plasma level than formulation B. However, formulation B had a time lag, so the plasma level was less than MEC for an initial period of 1 hr. In formulation A, the plasma level was maintained within the therapeutic window $(0.3-5\;{\mu}g/ml)$ for a long period. Formulation A was thought to be an ideal sustained-release formulation for ketorolac tromethamine oral delivery system.

  • PDF

Two-Level Hierarchical Production Planning for a Semiconductor Probing Facility (반도체 프로브 공정에서의 2단계 계층적 생산 계획 방법 연구)

  • Bang, June-Young
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.159-167
    • /
    • 2015
  • We consider a wafer lot transfer/release planning problem from semiconductor wafer fabrication facilities to probing facilities with the objective of minimizing the deviation of workload and total tardiness of customers' orders. Due to the complexity of the considered problem, we propose a two-level hierarchical production planning method for the lot transfer problem between two parallel facilities to obtain an executable production plan and schedule. In the higher level, the solution for the reduced mathematical model with Lagrangian relaxation method can be regarded as a coarse good lot transfer/release plan with daily time bucket, and discrete-event simulation is performed to obtain detailed lot processing schedules at the machines with a priority-rule-based scheduling method and the lot transfer/release plan is evaluated in the lower level. To evaluate the performance of the suggested planning method, we provide computational tests on the problems obtained from a set of real data and additional test scenarios in which the several levels of variations are added in the customers' demands. Results of computational tests showed that the proposed lot transfer/planning architecture generates executable plans within acceptable computational time in the real factories and the total tardiness of orders can be reduced more effectively by using more sophisticated lot transfer methods, such as considering the due date and ready times of lots associated the same order with the mathematical formulation. The proposed method may be implemented for the problem of job assignment in back-end process such as the assignment of chips to be tested from assembly facilities to final test facilities. Also, the proposed method can be improved by considering the sequence dependent setup in the probing facilities.

A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux (건축용 바닥재의 외부복사열에 의한 화재위험성 비교 연구)

  • Park, Youngju;Kim, Youngtak
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.20-24
    • /
    • 2017
  • In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.