• 제목/요약/키워드: Release Guideline

검색결과 89건 처리시간 0.029초

국내.외 지속가능경영보고서의 산업안전보건 분야의 GRI guideline을 이용한 평가 및 산업안전보건법을 이용한 지표 개발에 관한 연구 (A Study on the Indicator Development using Industrial Safety Sanitation Field GRI Guideline and Industrial Safety Sanitation Act from Domestic and Overseas Sustainable Management Reports)

  • 조기홍;임화영;최순영
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.1-6
    • /
    • 2009
  • This study was evaluated the indicators of GRI guideline LA6-LA9 for industrial safety sanitation field on 22 domestic sustainable management reports and 46 overseas reports published by companies in 2007 and 2008, was developed new indicators with emphasis on industrial safety sanitation act, and was assessed whether they are released. As a result, LA6(Percent of total workforce represented in formal joint management-work health and safety committees that help monitor and advise on occupational health and safety programs) was evaluated highest in release ratio on whether to release the reports by each indicator of industrial safety sanitation field using domestic sustainable management report GRI guideline, and in the case of overseas companies, it was evaluated that there is no companies that release all from LA6 through LA9 among GRI guideline, but it was grasped that the ratio of partial release is high. As for the release of indicators was developed with the use of industrial safety sanitation act of 22 domestic companies, the release of indicator No. 1(report and industrial disaster record) and 10(health diagnosis) of industrial safety sanitation act was high. This study is meaningful in that it analyzed the industrial safety sanitation field of sustainable management report(CSR) that has not been attempted so far with the use of new indicators developed with emphasis on GRI guideline and industrial safety sanitation act.

안전기준을 만족하는 철도차량 내장재의 화재 열방출율 측정시험 (A Fire Test Measuring the Heat Release Rate of Railway Car Interior Materials Satisfying the Korean Safety Guideline)

  • 박원희;이덕희;정우성
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.40-49
    • /
    • 2009
  • 철도차량 내장재를 설치한 화재 시험 공간(ISO 9705)에서 대규모 화재시험이 수행되었다. 여기서 사용된 내장재는 2004년 12월에 공포된 철도차량에 대한 안전기준을 만족하는 내장재이다. 화원으로는 가스버너를 이용하였으며 가스버너의 출력은 시간에 따라 증가하도록 설정하였다. 본 시험의 목적은 철도차량 내장재의 화염전파와 발화에 대한 화재 성능 평가이며, 플레시오버로 성장하는 철도차량 내장재를 포함하는 화재에 대한 여러 데이터들의 확보이다. 이 데이터들은 철도차량 내장재의 화재 성장을 예측하는 모델을 검증하고 개발하는데 사용될 것이다.

Calculation of preliminary site-specific DCGLs for nuclear power plant decommissioning using hybrid scenarios

  • Seo, Hyung-Woo;Sohn, Wook
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1098-1108
    • /
    • 2019
  • Korea's first commercial nuclear power plant at Kori site was permanently shut down in 2017 and is currently in transition stage. Preparatory activities for decommissioning such as historical site assessment, characterization, and dismantling design are being actively carried out for successful D&D (Dismantling and Decontamination) at Kori site. The ultimate goal of decommissioning will be to ensure the safety of workers and residents that may arise during the decommissioning of nuclear facilities and, thereby finally returning the site to its original status in accordance with the release criteria. Upon completion of decommissioning, the resident's safety at a site released will be assessed from the evaluation of dose caused by radionuclides expected to be present or detected at the site. Although the U.S. commercial nuclear power plants with decommissioning experience use different site release criteria, most of them are 0.25 mSv/y. In Korea, both the unrestricted and restricted release criteria have been set to 0.1 mSv/y by the Nuclear Safety and Security Commission. However, since the dose is difficult to measure, measurable concentration guideline levels for residual radionuclides that result in dose equivalent to the site release criteria should be derived. For this derivation, site reuse scenario, selection of potential radionuclides, and systematic methodology should be developed in planning stage of Kori site decommissioning. In this paper, for calculation of a preliminary site-specific Derived Concentration Guideline Levels (DCGLs) for the Nuclear Power Plant site, a novel approach has been developed which can fully reflect practical reuse plans of the Kori site by taking into account multiple site reuse scenarios sequentially, thereby striking a remarkable distinction with conventional approaches which considers only a single site scenario.

주요 누출사고 예측 모델의 사용 특성 비교 (Usage Characteristics of Publicly-Available Accidental Release Models)

  • 정수희;윤도영;김영성
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.687-696
    • /
    • 1999
  • Characteristics of four publicly-available accidental release models, ALOHA, SLAB, HGSYSTEM, and DEGADIS, are compared. These models are world-widely used and recently recommended by the Chemical Dispersion and Consequence Assessment(CDCA) Working Group of the United States as models applicable to generally broad safety-basis documentation applicatons. Four release scenarios are assumed by referring to the usage and storage conditions of toxic substances in the field as well as the USEPA model guideline(1993). Sensitivity of impact radius by varying meteorological conditions is tested in typical and worst-case meteorological conditions. The results show that ALOHA generally gives conservative estimates and the results from HGSYSTEM are sensitive to variations in meteorological conditions.

  • PDF

반도체 산업설비의 사고시 사업장외에 미치는 영향평가 (Offsite Risk Assessment of Incidents in a Semiconductor Facility)

  • 윤여홍;박교식;김태옥;신동민
    • 한국위험물학회지
    • /
    • 제3권1호
    • /
    • pp.59-64
    • /
    • 2015
  • Semiconductor industry has large number of chemical inventory and is easily exposed to chemical release incidents. Toxic release is one of the most interested area in evaluating consequence to the vicinity of industry facilities handling hazardous materials. Hydrofluoric acid is one of the typical chemical used in semiconductor facility and is selected and toxic release is evaluated to assess the risk impacted to its off-site. Accident scenarios were listed using process safety information. The scenarios having effect to the off-site were selected and assessed further according to guideline provided by Korea government. Worst case and alternative scenarios including other interested scenarios were evaluated using ALOHA. Each evaluated scenario was assessed further considering countermeasures. The results showed that the facility handling hydroflooric acid is safe enough and needed no further protections at the moment.

서방성 경구제형의 개발과 평가 및 생체내.외 상관성 연구를 위한 가이드라인 (Guideline for Extended Release Oral Dosage Forms : Development, Evaluation, and Application of In Vitro/In Vivo Correlations)

  • 최선옥;정성희;엄소영;정서정;김주일;김옥희
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권6호
    • /
    • pp.471-481
    • /
    • 2005
  • In Korea, generic drug and bioequivalence test are the hot issues since a new medical system of separation of dispensary from medical practice was started in 2000. The KFDA(Korea FDA) had revised several times ${\ulcorner}Guidance\;for\;bioequivalence\;test{\lrcorner}$. In vitro dissolution test has been extensively used as a quality control tool for solid oral dosage forms. In an effort to minimize unnecessary human testing, in vitro/in vivo correlations (IVIVC) between in vitro dissolution and in vivo bioavailability are increasingly becoming an integral part on extended release drug product development. The recently published US guidance, ${\ulcorner}Extended\;release\;oral\;dosage\;forms\;:\;development,\;evaluation,\;and\;application\;of\;in\;vitro/in\;vivo\;correlations{\lrcorner}$ will be helpful for us to make our own guideline.

재래시장의 화재확산 방지를 위한 수막설비 설치 지침 (The Water Curtain Installation Guideline for Fire Spread Prevention in Market)

  • 최정욱;조성우
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

Proposal to Revise the Screening Test for Latent Tuberculosis Infection in Close Contacts at Elementary Schools in Korea

  • Bae, Jong-Myon
    • Journal of Preventive Medicine and Public Health
    • /
    • 제52권4호
    • /
    • pp.272-275
    • /
    • 2019
  • The 2018 National Guideline for Tuberculosis Control, which was published by the Korea Centers for Diseases Prevention and Control (KCDC), mandates conducting an epidemiological survey among close contacts of active tuberculosis patients at public institutions such as schools. In the procedure for these surveys, the tuberculin skin test (TST) is mandated as the screening test for latent tuberculosis infection in elementary school students. However, several guidelines recommend using the interferon-gamma releasing assay (IGRA) for contacts aged over 5 years with a Bacillus Calmette-$Gu{\acute{e}}rin$ vaccination history. The main reason for this is that IGRA has a higher specificity and lower false positive rate than TST. In addition, IGRA requires only a single visit to draw blood and the results are available within 24 hours. These advantages could promote cooperation from both parents and students in conducting these surveys. Thus, these findings regarding the benefits of IGRA for surveys of close contacts at elementary schools should be incorporated into the KCDC guideline.

Derivation of preliminary derived concentration guideline levels for surface soil at Kori Unit 1 by RESRAD probabilistic analysis

  • Byon, Jihyang;Park, Sangjune;Ahn, Seokyoung
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1289-1297
    • /
    • 2018
  • Preliminary surface soil Derived Concentration Guideline Levels (DCGLs) were derived conforming to the Multi-Agency Radiation Site Survey and Investigation Manual (MARSSIM) procedure for the site release and reuse of Kori Unit 1 in Korea. Based on the decommissioning experiences of the U.S. nuclear power plants, a suite of residual radionuclides was determined, and uncertainties contributed to the resultant dose by the input parameters were quantified via the sensitivity analysis of parameters. The peak of the mean dose was obtained via the probabilistic analysis of the RESRAD (RESidual RADioactivity)-ONSITE code. Consequently, $DCGL_w$ of Kori Unit 1 in accordance with two scenarios, industrial worker and residential farmer scenario, were derived and the results were compared respectively with other NPPs. It could be used as a basic guideline for establishing regulatory standards for reuse planning, designing the site characterization surveys and implementing final status survey (FSS).

KS C IEC 60079-10-1 규격의 무시할 수 있는 정도와 누출특성에 관한 연구 (Study on the Negligible Extent(NE) and Release Characteristic of KS C IEC 60079-10-1(2015) Standard)

  • 조필래;이향직;백종배
    • 한국안전학회지
    • /
    • 제35권2호
    • /
    • pp.111-117
    • /
    • 2020
  • When KS C IEC 60069-10-1(2015) standard is applied to estimate a hazardous area, the chart showing the relationship between a hazardous area distance and release characteristic is used as a guide to determine the extent of hazardous zones for various forms of release. Three release characteristic lines based on the three types of release as an unimpeded jet release with high velocity, a diffusive jet release with low velocity, and a release of heavy gases or vapours that spread along horizontal surfaces are given. As these characteristic lines have the low limit threshold, it is difficult to estimate the hazardous area distance when the value of release characteristic is under the low limit threshold. And KS C IEC 60079-10-1(2015) standard shows the concept for a zone of Negligible extent(NE) which can be considered as non hazardous area, but it is also difficult to apply the concept of a Negligible extent. The purpose of this paper is to suggest the guideline for the release characteristic to decide a hazardous area distance and the Negligible extent(NE) being considered as non-hazardous area when deciding a hazardous area distances by the KS C IEC 60079-10-1 standard.