• Title/Summary/Keyword: Relaying signal

Search Result 144, Processing Time 0.032 seconds

Performance Analysis of NOMA-based Relaying Networks with Transceiver Hardware Impairments

  • Deng, Chao;Zhao, Xiaoya;Zhang, Di;Li, Xingwang;Li, Jingjing;Cavalcante, Charles Casimiro
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.9
    • /
    • pp.4295-4316
    • /
    • 2018
  • In this paper, the performance of non-orthogonal multiple access (NOMA) dual-hop (DH) amplify-and-forward (AF) relaying networks is investigated, where Nakagami-m fading channel is considered. In order to cover more details, in our analysis, the transceiver hardware impairments at source, relay and destination nodes are comprehensively considered. To characterize the effects of hardware impairments brought in NOMA DH AF relaying networks, the analytical closed-form expressions for the exact outage probability and approximate ergodic sum rate are derived. In addition, the asymptotic analysis of the outage probability and ergodic sum rate at high signal-to-noise ratio (SNR) regime are carried out in order to further reveal the insights of the parameters for hardware impairments on the network performance. Simulation results indicate the performance of asymptotic ergodic sum rate are limited by levels of distortion noise.

Double Opportunistic Transmit Cooperative Relaying System with GSC in Rayleigh Fading Channels

  • Kim, Nam-Soo;Lee, Ye-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.270-275
    • /
    • 2010
  • In a conventional opportunistic transmit (COT) cooperative relaying system, only the relays that receive signal-to-noise ratio (SNR) from the source and that exceed the threshold transmit to the destination. The COT system, however, only considers the SNR of the source-relay (S-R) path regardless that the SNR of the relay-destination (R-D) path is the opportunistic transmission condition. For that reason, it is not guaranteed that all the transmitted signals from relays exceed the threshold at the destination. Therefore we propose a double opportunistic transmit (DOT) cooperative relaying system - when both of the received SNR from a source and from a destination exceed the threshold, the relay transmits to the destination. It is shown that the proposed DOT system reduces power consumption by 6.9, 20.9, 32.4, and 41.4 % for K =3, 5, 7, and 9, respectively under the given condition of $P_{out}=1{\times}10^{-3}$ and $\overline{\gamma}_{SR}/\Gamma_{SR}$=30 dB, compared to the COT system. We noticed that the performance of the DOT system is superior to that of the COT system for the identical number of active transmit relays under the same condition of the normalized average SNR of $\overline{\gamma}_{RD}/\Gamma_{RD}$.

Correction of Overcurrent Protective Relay on Distribution Feeders Considering the Power Output of Wind Farm Interconnected with Utility Networks (계통 연계 풍력발전단지의 출력 조건을 고려한 배전선 과전류 계전기 정정)

  • Kim, J.W.;Jang, S.I.;Kim, K.H.;Yoo, N.S.;Park, H.J.;Song, D.S.;Lee, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.342-344
    • /
    • 2003
  • This paper describes the correction of overcurrent protective relaying set value in distribution networks interconnected with wind farm by dedicated line. The wind farm composed of wind turbine generators is one of the great energy sources; however, it would be also highly possible that the current in the point of common coupling is influenced by the output power of wind farm. So, the overcurrent relay applied in distribution feeders might generate trip signal for normal operation. In order to prevent the mal-operation of overcurrent relay, it is necessary to correct the relay's setting value according to the output power of end farm. This paper presents the influence of wind farm on the overcurrent relaying set value in distribution feeders for cases of fault as well as normal operation and proposes the basic strategy for correction of overcurrent relaying set value.

  • PDF

Ground fault protective relaying schemes for DC traction power supply system (비접지 DC 급전계통에서 전류형 지락보호계전 방법)

  • 정상기;정락교;이성혁;김연수;조홍식
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.412-417
    • /
    • 2004
  • In urban rail transit systems, ground faults in the DC traction power supply system are currently detected by the potential relay, 64P. Though it detects the fault it cannot identify the faulted region and therefore the faulted region could not be isolated properly. Therefore it could cause a power loss of the trains running on the healthy regions and the safety of the passengers in the trains could be affected adversely. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. A current limiting device, called Device X, is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. One type of the relaying schemes is called directional and differential ground fault protective relay which uses the current differential scheme in detecting the fault and uses the permissive signal from neighboring substation to identify the faulted region correctly. The other is called ground over current protective relay. It is similar to the ordinary over current relay but it measures the ground current at the device X not at the power feeding line, and it compares the current variation value to the ground current in Device X to identify the correct faulted line. Though both type of the relays have pros and cons and can identify the faulted region correctly, the ground over current protective relaying scheme has more advantages than the other.

Performance Analysis And Optimization For AF Two-Way Relaying With Relay Selection Over Mixed Rician And Rayleigh Fading

  • Fan, Zhangjun;Guo, Daoxing;Zhang, Bangning;Zeng, Li
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.12
    • /
    • pp.3275-3295
    • /
    • 2012
  • In this paper, we analyze the performance of an amplify-and-forward (AF) two-way relaying system, where two sources exchange information via the aid of an intermediate relay that is selected among multiple relays according to max-min criterion. We consider a practical scenario, where one source-relay link undergoes Rician fading, and the other source-relay link is subject to Rayleigh fading. To be specific, we derive a tight lower bound for the outage probability. From this lower bound, the asymptotic outage probability and average symbol error rate (SER) expressions are derived to gain insight into the system performance at high signal-to-noise ratio (SNR) region. Furthermore, we investigate the optimal power allocation (PA) with fixed relay location (RL), optimal RL with fixed PA and joint optimization of PA and RL to minimize the outage probability and average SER. The analytical expressions are verified through Monte Carlo simulations, where the positive impact of Rician factor on the system performance is also illustrated. Simulation results also validate the effectiveness of the proposed PA and relay positioning schemes.

Phasor Estimation Method Eliminating the Effect of the DC offsets (DC 옵셋의 영향을 제거한 페이저 연산 기법)

  • Lee, Dong-Gyu;Kim, Hyung-Kyu;Kwon, Young-Jin;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.203_204
    • /
    • 2009
  • In this paper, we propose a Fourier transform-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Discrete Fourier Transform (DFT) is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. In this paper, the error due to DC offsets in a DFT is calculated and eliminated using the outputs of quaternity DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated by using computer-simulated signals and EMTP-generated signals. A performance evaluation showed that the proposed algorithm was not affected by system and fault conditions. Thus, the proposed algorithm can effectively suppress the adverse influence of DC offsets in a relaying signal.

  • PDF

A Current Differential Relaying Algorithm for Power Transformers Using the Difference of a Differential Current (차전류의 차분을 이용한 변압기 보호용 전류차동 계전방식)

  • Kang, Y.C.;Kim, D.S.;Lee, B.E.;Kim, E.S.;Won, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.274-276
    • /
    • 2002
  • This paper proposes a current differential relaying algorithm for power transformers using the third difference function of a differential current. The algorithm observes the instants when the wave-shape of the differential current is changed due to the change of the magnetization inductance. If the value of the third difference is bigger than the threshold, the output of a current differential relay is blocked for a cycle. In the cases of magnetic inrush and overexcitation, the blocking signal is maintained: however, for internal faults, reset in a cycle. The test results clearly show that the algorithm successfully distinguishes internal faults from magnetizing inrush.

  • PDF

A Distance Relaying Algorithm Using an Improved Technique for Removing DC-offset (DC-Offset 제거 기능을 향상시킨 거리계전 알고리즘)

  • No, Jae-Keun;Kang, Sang-Hee;Nam, Soon-Ryul;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.118-120
    • /
    • 2001
  • This paper presents a distance relaying algorithm based on the Discrete Fourier Transform(DFT) for elimination of DC-Offset. When the DFT is applied to current signal. the real and imaginary parts of fundamental component consist of fundamental component itself and DC-Offset. The DC-Offset is calculated by four consecutive values of the imaginary components, so that the fundamental component can be accurately estimated. Performance evaluation is presented for A-phase ground faults on 154kV 80km overhead transmission line. The proposed algorithm is inspected by software simulation and hardware simulation.

  • PDF

A Percentage Current Differential Relaying Algorithm for Bus Protection Using an Advanced Compensating Algorithm of the CTs (개선된 변류기 보상알고리즘을 적용한 모선보호용 비율전류차동 계전방식)

  • 강용철;윤재성;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.158-164
    • /
    • 2003
  • This paper proposes a percentage current differential relaying algorithm for bus protection using an advanced compensating algorithm of the secondary current of current transformers (CTs). The compensating algorithm estimates the core flux at the start of the first saturation based on the value of the second-difference of the secondary current. Then, it calculates the core flux and compensates distorted currents using the magnetization curve. The algorithm Is unaffected by a remanent flux. The simulation results indicate that the proposed algorithm can discriminate internal faults from external faults when the CT saturates. This paper concludes by implementing the algorithm into a TMS320C6701 digital signal processor. The results of hardware implementation are also satisfactory. The proposed algorithm can improve not only stability of the relay in the case of an external fault but sensitivity of the relay in the case of an internal fault.

Dual-Hop Amplify-and-Forward Multi-Relay Maximum Ratio Transmission

  • Erdogan, Eylem;Gucluoglu, Tansal
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • In this paper, the performance of dual-hop multi-relay maximum ratio transmission (MRT) over Rayleigh flat fading channels is studied with both conventional (all relays participate the transmission) and opportunistic (best relay is selected to maximize the received signal-to-noise ratio (SNR)) relaying. Performance analysis starts with the derivation of the probability density function, cumulative distribution function and moment generating function of the SNR. Then, both approximate and asymptotic expressions of symbol error rate (SER) and outage probability are derived for arbitrary numbers of antennas and relays. With the help of asymptotic SER and outage probability, diversity and array gains are obtained. In addition, impact of imperfect channel estimations is investigated and optimum power allocation factors for source and relay are calculated. Our analytical findings are validated by numerical examples which indicate that multi-relay MRT can be a low complexity and reliable option in cooperative networks.