• Title/Summary/Keyword: Relative signal intensity

Search Result 64, Processing Time 0.034 seconds

Chemiluminescence Determination of Balofloxacin Based on Europium (III)-Sensitized KBrO3-Na2S2O4 Reaction in Micellar Medium

  • Zhao, Fang;Qi, Yu;Xiong, Wei
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.204-208
    • /
    • 2012
  • A novel chemiluminescence (CL) flow injection method for the determination of balofloxacin is described. The method is based on the weak CL signal arising from the reaction of $KBrO_3$ with $Na_2S_2O_4$ in acidic medium being significantly enhanced by balofloxacin in the presence of europium (III) ion and sodium dodecyl benzene sulfonate (SDBS). The experimental conditions that affected CL intensity were carefully optimized and the CL reaction mechanism was briefly discussed. Under the optimum conditions, the relative CL intensity was proportional to the concentration of balofloxacin in the range of $7.0{\times}10^{-11}$ to $3.0{\times}10^{-7}g\;mL^{-1}$. The detection limit was $2.7{\times}10^{-11}g\;mL^{-1}$ and the relative standard deviation was 2.1% for $7.0{\times}10^{-10}g\;mL^{-1}$ balofloxacin (n = 13). The proposed method was successfully applied to the determination of balofloxacin in pharmaceutical formulations and biological fluids.

Radiologic-Pathologic Correlation of Unusual Lingual Masses: Part II: Benign and Malignant Tumors

  • Se Hyung Kim;Moon Hee Han;Sun Won Park;Kee-Hyun Chang
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.42-51
    • /
    • 2001
  • Because the tongue is superficially located and the initial manifestation of most diseases occurring there is mucosal change, lingual lesionscan be easily accessed and diagnosed without imaging analysis. Some lingual neoplasms, however, may manifest as a submucosal bulge and be located in a deep portion of the tongue, such as its base; their true characteristics and extent may be recognized only on cross-sectional images such as those obtained by CT or MRI. Some uncommon tongue neoplasms may have characteristic radiologic features, thus permitting quite specific radiologic diagnosis. Lipomas typically manifest at both CT and MR imaging as homogeneous nonenhancing lesions. Relative to subcutaneous fat they are isoattenuating on CT images, and all MR sequences show them as isointense. Due to the paramagnetic properties of melanin, metastases from melanotic melanoma usually demonstrate high signal intensity on T1-weighted MR images and low signal intensity on T2-weighted images. Although the radiologic findings for other submucosal neoplasms are nonspecific, CT and MR imaging can play an important role in the diagnostic work-up of these unusual tumors. Delineation of the extent of the tumor, and recognition and understanding of the spectrum of imaging and the pathologic features of these lesions, often help narrow the differential diagnosis.

  • PDF

Novel Intensity-Based Fiber Optic Vibration Sensor Using Mass-Spring Structure (질량-스프링 구조를 이용한 새로운 광세기 기반 광섬유 진동센서)

  • Yi, Hao;Kim, Hyeon-Ho;Choi, Sang-Jin;Pan, Jae-Kyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.78-86
    • /
    • 2014
  • In this paper, a novel intensity-based fiber optic vibration sensor using a mass-spring structure, which consists of four serpentine flexure springs and a rectangular aperture within a proof mass, is proposed and its feasibility test is given by the simulation and experiment. An optical collimator is used to broaden the beam which is modulated by the displacement of the rectangular aperture within the proof mass. The proposed fiber optic vibration sensor has been analyzed and designed in terms of the optical and mechanical parts. A mechanical structure has been designed using theoretical analysis, mathematical modeling, and 3D FEM (Finite Element Method) simulation. The relative aperture displacement according to the base vibration is given using FEM simulation, while the output beam power according to the relative displacement is measured by experiment. The simulated sensor sensitivity of $15.731{\mu}W/G$ and detection range of ${\pm}6.087G$ are given. By using reference signal, the output signal with 0.75% relative error shows a good stability. The proposed vibration sensor structure has the advantages of a simple structure, low cost, and multi-point sensing characteristic. It also has the potential to be made by MEMS (Micro-Electro-Mechanical System) technology.

1.25 Gb/s Broadcast Signal Transmission in WDM-PON Based on Mutually Injected Fabry-Perot Laser Diodes

  • Yoo, Sang-Hwa;Mun, Sil-Gu;Kim, Joon-Young;Lee, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.101-106
    • /
    • 2012
  • We demonstrate a cost effective broadcast signal transmission at 1.25-Gb/s with 100 GHz channel spacing based on a broadband light source (BLS) for a wavelength division multiplexing-passive optical network (WDM-PON). The BLS is implemented by using mutually injected Fabry-Perot laser diodes (MI F-P LDs). The error-free transmission without a forward error correction (FEC) is achieved by its low relative intensity noise (RIN). The number of usable modes is determined by RIN and/or extinction ratio (ER) in the spectrum sliced light output.

Detection of Red Tides by IRS/OCM Imagery

  • Kang, Y.Q.;Suh, Y.S.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.697-699
    • /
    • 2003
  • We present a simple algorithm for detection of red patches by remote sensing in coastal waters of Korea. The red tide patches can by identified by the relative intensity of red band signal with respect to the blue-green background signal, provided the radiometric signals only in the sea area are properly stretched. We tested our algorithm by Ocean COlor Monitor(OCM) data of Indian Satellite IRS-P4, which has been received from 2001 by National Fisheries Research and Development Institute of Korea. A comparison of our results with observation shows that the locations of red tides derived from remote sending imagery by our algorithm are in accordance with observations.

  • PDF

Measurement of EUV (Extreme Ultraviolet) and electron temperature in a hypocycloidal pinch device for EUV lithography

  • Lee, Sung-Hee;Hong, Young-June;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.108-108
    • /
    • 2010
  • We have generated Ne-Xe plasma in dense plasma focus device with hypocycloidal pinch for extreme ultraviolet (EUV) lithography and investigated an electron temperature. We have applied an input voltage 4.5 kV to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ne-Xe(30%) gas in accordance with pressure. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium (LTE) conditions, the electron temperature of the hypocycloidal pinch plasma focus could be obtained by the optical emission spectroscopy (OES). The electron temperature has been measured by Boltzmann plot. The light intensity is proportion to the Bolzman factor. We have been measured the electron temperature by observation of relative Ne-Xe intensity. The EUV emission signal whose wavelength is about 6~16 nm has been detected by using a photo-detector (AXUV-100 Zr/C, IRD) and the line intensity has been detected by using a HR4000CG Composite-grating Spectrometer.

  • PDF

Coupling Intensity Effects in Ladder-type Electromagnetically Induced Transparency of Rb atoms (결합광 세기에 따른 Rb 원자의 사다리형 전자기 유도 투과)

  • Moon, H.S.;Lee, L.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • We have studied the polarization effects and the coupling intensity effects of electromagnetically induced transparency(EIT) in the 5S$_{1}$2-/5P$_{3}$2-/5D$_{5}$2/ ladder system of Rb. We obtained the EIT spectrum with the hyperfine structure of 5D$_{5}$2/ transitions and the minimal width of the measured EIT spectrum was 6.5 MHz. We observed the change of the relative magnitudes of the hyperfine structure of EIT according to not only the polarizations of lasers but also the intensity of the coupling laser. The cause of the coupling intensity effects is that the EIT signal nonlinearly increases to the coupling intensity.

Comparative assessment of a 1.5T endorectal coil and a 3.0T phased-array coil available for prostate MRI (전립선 MRI에서 사용하는 1.5T 경직장 코일과 3.0T 위상 배열 코일의 성능 비교 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.3
    • /
    • pp.283-290
    • /
    • 2010
  • The effectiveness of 3.0T phase array coil images was tested by comparing signal-to-noise ratios for the same coil images relative to 1.5T endorectal coil images. Signal intensities were measured in the three regions of prostate, central and peripheral (right and left) after 40 patients with prostate cancer were imaged during the period between Jan. 2008 and Oct. 2009 with T2 W, T1 W, and DW images obtained respectively using endorectal coil on a 1.5T MR scanner and phase array coil on a 3.0T MR scanner. For quantitative analysis, comparisons of average SNRs for the same ROIs were made between groups scanned with a 1.5T and a 3.0T MR scanner. The signal-to-noise ratios were shown to increase more sharply when using a phase array coil at a 3.0T MR scanner compared to using an endorectal coil at a 1.5T MR scanner.

Correlation between Magnetic Resonance Image Signal Changes and Electromyographic Findings after Sciatic Nerve Transection in the Rat (백서의 좌골신경 절단 후 비복근의 자기공명영상 신호강도 변화와 근전도 소견의 관계)

  • Lee, Joo Hwan;Lee, Jang Chul;Kim, Dong Won;Park, Ki Young;Lee, Sung Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.101-107
    • /
    • 2000
  • Objectives : The evaluation of peripheral nerve injuries has traditionally relied on a clinical history, physical examination, and electrodiagnostic studies. The purpose of the present study was to examine serial magnetic resonance image(MRI) changes following acute muscle denervation under experimental conditions and to identify potential advantages and disadvantages of this use of MRI. Methods : An experimental transection of right sciatic nerve on Spargue-Dawley rats was performed. MRI was performed with T1-weighted spin-echo and STIR sequences. The imaging findings were compared with EMG in order to determine its sensitivity relative to this standard procedure. A simultaneous histopathological study provided information about the morphological basis of the imaging findings. Signal intensities were expressed as a ratio of abnormal to normal. Results : The signal intensity ratio of muscles with the STIR sequence was increased significantly at 2 weeks after sciatic nerve transection(p<0.05), although definite signal change was seen as early as 4 days postdenervation in one. EMG revealed significant denervation potential from 3 days after nerve transection. Diffuse cell atrophy was revealed hostologically at 2 weeks after transection, which was at the same time of significant signal change in MRI. Conclusion : MRI signal changes in denervated muscles secondary to nerve injury correlate with the degree of muscle atrophy on histologic examination. In addition to EMG, MRI can document the course of muscle atrophy and mesenchymal abnormalities in denervation. These results indicate that MRI can play a complementary role in the evaluation of patients with denervation.

  • PDF

Solitary Fibrous Tumor of the Ischiorectal Fossa : CT and MRI Findings (좌골직장와에서 기원하는 고립섬유종양: CT, MR 영상소견의 증례 보고)

  • Kim, Ki-Hwan;Cha, Sang-Hoon;Yeom, Suk-Keu;Lee, Seung-Hwa;Chung, Hwan-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.72-76
    • /
    • 2011
  • Solitary fibrous tumor (SFT) is a rare neoplasm, which is usually presented as a pleural based mass, but can also occur in unusual locations based on its mesenchymal origin. However, the radiologic features of SFT occurred in the ischiorectal fossa have been rarely reported. In this case, we describe the MRI findings in a case of a SFT involving the ischiorectal fossa of a 36-year-old man. The tumor appeared as homogeneous iso-signal intensity relative to the adjacent muscle on T1 weighted images, a mixed high signal intensity on the T2 weighted images, and heterogeneous enhancement following the administration of the contrast material.