• Title/Summary/Keyword: Relative humidity sensor

Search Result 139, Processing Time 0.026 seconds

Humidity-Sensitive Properties of Polyelectrolytes Containing Alkoxysilane Crosslinkers

  • Gong, Myoung-Seon;Lee, Chil-Won;Park, Hyung-Seok
    • Macromolecular Research
    • /
    • v.12 no.3
    • /
    • pp.311-315
    • /
    • 2004
  • We have prepared new polyelectrolytes containing trialkoxysilyl groups by copolymerizing 3-(trimethoxysilyl)propyl methacrylate (TSPM) with either [2-(methacryloyloxy)ethyl]trimethyl ammonium chloride (METAC), [2-(methacryloyloxy)ethyl]dimethyl propyl ammonium bromide (MEDPAB), or [2-(acryloyloxy)ethyl]trimethyl ammonium chloride (AETAC). The copolymers TSPM/METAC, TSPM/MEDPAB, and TSPM/METAC having compositions of 15/85, 10/90, and 5/95, respectively, were self-crosslinkable polyelectrolytes that possess humidity-sensitive properties. We measured the impedances of the copolymers at various relative humidities (RHs) and found that the resistance was dependent on the content of METAC, MEDPAB, or AETAC. The impedance changed from 10$\^$7/ $\Omega$ at 20% RH to 10$^3$ $\Omega$ at 95% RH, which is quite a suitable range for a humidity sensor that is to be utilized at ambient humidity. We also performed tests of the materials temperature dependence, hysteresis, response time, and water durability.

Humidity-Sensitive Characteristics and Reliabilities of Polymeric Humidity Sensor Containing Phosphonium Salts (포스포늄 염을 가진 고분자 습도센서의 감습 특성 및 신뢰성)

  • Kim, Ohyoung;Gong, Myoung-Seon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.554-560
    • /
    • 1998
  • Vinylbenzyl triphenyl phosphonium chloride(VTPC)/styrenes=3.7 copolymer was prepared for the moisture-absorptive polyelectrolyte dew sensor containing phosphonium salts. The humid membrane was fabricated on the gold/alumina electrode by dipping. The impedances were $11M{\Omega}$, $980k{\Omega}$, $50k{\Omega}$, and $11k{\Omega}$ at 70%RH, 80%RH, 90%RH and 95%RH, respectively, at $25^{\circ}C$ and the humidity-sensitive charactristic was suitable for the dew sensor. The temperature-dependent coefficient between $15^{\circ}C$ and $35^{\circ}C$ was found to be $-0.25%RH/^{\circ}C$ and the hysteresis falled in the ${\pm}2%RH$ range. The response time was found to be 45 sec for the relative humidity ranging from 70%RH to 98%RH at $25^{\circ}C$. The reliabilities such as temperature cycle, humidity cycle, high temperature and humidity resistance, electrical load stability, stability of long-term storage and water durability were measured and evaluated for the application as a dew sensor.

  • PDF

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..

Humidity Sensor using Polyvinylpyrrolidone-Coated Mach-Zehnder Interferometer in Planar Lightwave Circuit (폴리비닐피롤리돈이 코팅된 마하젠더 간섭계 기반의 평판형 광도파로 습도센서)

  • Kim, Ju Ha;Kim, Myoung Jin;Jung, Eun Joo;Hwang, Sung Hwan;Lee, Woo Jin;Choi, Eun Seo;Rho, Byung Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.251-255
    • /
    • 2013
  • In this paper, the characteristics of a humidity sensor implemented by Mach Zehnder Interferometer (MZI) in a Planar Lightwave Circuit (PLC) have been designed and demonstrated. The humidity outside is detected with polyvinylpyrrolidone (PVP) coated on the etched arm of the MZI. The length of the etched arm is 10 mm and the PVP was coated by dip-coating into the etched region. As the refractive index of the PVP changes with the surrounding humidity, the PVP-coated humidity sensor presented changes in the interferogram depending on RH (Relative Humidity) around the PLC. The measured results show that the proposed humidity sensor works successfully in the range of 30% to 80% of RH.

Humidity-Sensitive Characteristics and Reliabilities of Polymeric Humidity Sensors Using 2-Methacryloxyethyl dimethyl 2-hydroxyethyl ammonium brornide (2-Methacryloxyethyl dimethyl 2-hydroxyethyl ammonium bromide를 이용한 고분자 습도센서의 감습 특성 및 신뢰성)

  • Lee, Chil-Won;Gong, Myoung-Seon
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.461-466
    • /
    • 1999
  • The humidity sensor containing ammonium salt was prepared from the copolymer of 2-methacryloxyethyl dimethyl 2-hydroxyethyl ammonium bromide (MDHAB)/MMA/DAEMA = 6/3/1. The humid membrane was fabricated on the gold/alumina electrode by dipping. The impedances were $298k{\Omega},\;11k{\Omega}$, and $2.3k{\Omega}$ at 40%RH, 70%RH and 90%RH, respectively, at $5^{\circ}C$ and the humidity-sensitive characteristics were suitable for low temperature humidity sensor. The temperature-dependent coefficient between $5^{\circ}C$ and $20^{\circ}C$ was found to be $-0.80%RH/^{\circ}C$ and the hysteresis falled in the ${\pm}2%RH$ range. The response time was found to be 38 sec for the relative humidity ranging from 34%RH to 88%RH at $20^{\circ}C$. The reliabilities such as temperature cycle, humidity cycle, high temperature and humidity resistance, electrical load stability, stability of long-term storage and water durability were measured and evaluated for the application as a humidity sensor.

  • PDF

Preparation of Water-Resistant Humidity Sensor Using Photocurable Reactive Oligomers Containing Ionene Unit and Their Properties (이온넨 단위를 가지는 광경화성 반응성 올리고머를 이용한 내수성 습도센서의 제조 및 감습 특성)

  • Jeon, Young-Min;Gong, Myoung-Seon
    • Polymer(Korea)
    • /
    • v.33 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • New polyelectrolytes derived from ionene-containing photocurable reactive oligomer (PIDM) were prepared for water-resistant humidity-sensitive membranes. The mixture of PIDM, hexamethylene dimethacrylate (HDM), pentaerythritol triacrylate dimer (SP1013), and photoinitiator was simultaneously coated on the sensor electrode with photoinitiated radical polymerization. The pretreatment of the substrates with vinyl-type silane-coupling reagent was performed for improving the water durability and stability of the sensors at high temperature and humidity. When the resistance dependences on the relative humidity of the crosslinked PIDMs were measured, it was found that the resistance varied three orders of magnitude between 20 and 90%RH, which was required for the humidity sensor operating at ambient humidity. Their hysteresis, temperature dependence, response time, water durability, and high temperature/humidity stabilities were measured and evaluated as a humidity-sensing membrane.

Design and Fabrication of CMOS Micro Humidity Sensor System (CMOS 마이크로 습도센서 시스템의 설계 및 제작)

  • Lee, Ji-Gong;Lee, Sang-Hoon;Lee, Sung-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.146-153
    • /
    • 2008
  • Integrated humidity sensor system with two stages operational amplifier has been designed and fabricated by $0.8{\mu}m$ analog mixed CMOS technology. The system (28 pin and $2mm{\times}4mm$) consisted of Wheatstone-bridge type humidity sensor, resistive type humidity sensor, temperature sensors and operational amplifier for signal amplification and process in one chip. The poly-nitride etch stop process has been tried to form the sensing area as well as trench in a standard CMOS process. This modified technique did not affect the CMOS devices in their essential characteristics and gave an allowance to fabricate the system on same chip by standard process. The operational amplifier showed the stable operation so that unity gain bandwidth was more than 5.46 MHz and slew rate was more than 10 V/uS, respectively. The drain current of n-channel humidity sensitive field effect transistor (HUSFET) increased from 0.54 mA to 0.68 mA as the relative humidity increased from 10 to 70 %RH.

  • PDF

Humidity Sensing Properties of Iodine-doped PPA Thin Films (Iodine-doped PPA 박막의 감습특성)

  • Min, Nam-Ki;Kang, Hyun-Sik;Kim, Tae-Yoon;Kim, Suk-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1561-1563
    • /
    • 1998
  • A capacitive humidity sensor is used as a test device to characterize the performance of iodine doped polyphenylacetylene(PPA) thin films in relative humidity sensing application In comparison with undoped PPA thin films. the iodine doped PPA films showed higher sensitivity(0.19pF/%RH), better linearity(4.2%FS), much lower hysteresis and lower temperature coefficients(0.043 $\sim$ 0.067pF/$^{\circ}C$) over a wide range of relative humidity.

  • PDF

Characteristics of Polyimides Humility Sensor Fabricated by using Electrophoretic Deposition (전기영동법에 의해 제작된 폴리이미드 박막의 습도 특성)

  • 조동헌;정병기;한상옥;김종석;박강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.67-70
    • /
    • 1994
  • On this study, we fabricated humudity sensor with polyimide thin film from the nonaqueous emulsion by the electrophoretic deposition as a function of film thickness. then evaluated performance of the sensor with increasing relative humidity if constant temperature constant humidity chamber, which is electronically controlled. we designed upper electrode of the sensor to brush type to make moisture particles permeate into the polymer bulk. sensing properties of the sensor on % RH shows proportion on the low %RH. Fer the 30V-30S- 200$^{\circ}C$ sample, percentage changing of capacitance on from 30 %RH to 90 %RH is 45.8 %, and increasing rate per 1 % RH of capacitance is 11.25 pF

  • PDF

The Influence ${Sb_2}{O_3)$ Addition on Humidity Sensing Properties of $SnO_2$Thick Film Devices (${Sb_2}{O_3)$ 의 첨가가 $SnO_2$후막의 감습 특성에 미치는 영향)

  • 김종택;이덕출;김철수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.294-299
    • /
    • 2000
  • For practical application as a humidity sensor SnO$_2$thick films devices were fabricated on the refresh type electrode by screen printing method and their material and humidity sensing properties were investigated. As a function of Sb$_{2}$/O$_{3}$ addition rate grain size was increased while porosity and initial resistance were rapidly decreased. And the area of resistance variation according to relative humidity was decreased with increasing heat treatment temperature. SnO$_2$thick film device heat treated at 95$0^{\circ}C$ and contained 0.05mole% Sb$_{2}$/O$_{3}$ had a best humidity sensing properties. From this result it is conformed that humidity sensing properties of SnO$_2$thick film devices could be approved by very small amount of Sb$_{2}$/O$_{3}$ addition.

  • PDF