• Title/Summary/Keyword: Relative energy

Search Result 2,022, Processing Time 0.027 seconds

Effects of lactic acid bacteria inoculation in pre-harvesting period on fermentation and feed quality properties of alfalfa silage

  • Ertekin, Ibrahim;Kizilsimsek, Mustafa
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.2
    • /
    • pp.245-253
    • /
    • 2020
  • Objective: To develop the fermentation quality and chemical composition of alfalfa (Medicago sativa Lam.) silage, plants were inoculated with different lactic acid bacteria (LAB) strains at field 24 hours before harvest. Methods: The treatment groups were as follow: silage without additive as a control and inoculated with each strains of Lactobacillus brevis (LS-55-2-2), Leuconostoc citerum (L. citerum; L-70-6-1), Lactobacillus bifermentans (L. bifermentans; LS-65-2-1), Lactobacillus plantarum (L. plantarum; LS-3-3) and L. plantarum (LS-72-2). All the silages were stored at 25℃. Parameters such as pH, microorganism and volatile fatty acid contents, crude protein, neutral detergent fiber, acid detergent fiber, net gas, metabolizable energy, organic matter digestibility, dry matter intake and relative feed value were measured to determine fermentation quality, chemical compositions and relative feed value of alfalfa silages. Results: Significant differences were found among the control and treated groups in terms of pH and microorganism contents at all opening times and crude protein, net gas, metabolizable energy and organic matter digestibility of final silage. The pH values ranged from 4.70 to 5.52 for all treatments and control silage had the highest value of overall treatments at T75d silages. Volatile fatty acid of silages was not influenced significantly by inoculations. However, lactic acid content of L. bifermentans (LS-65-2-1) was higher than the other treatments. The highest metabolizable energy and organic matter digestibility were recorded from L. citerum (L-70-6-1) inoculation. In addition, no significant differences were found among treatments in terms of neutral detergent fiber, acid detergent fiber, dry matter intake and relative feed value. Conclusion: Among the treated LAB isolates, L. bifermentans came into prominence especially in terms of organic acid composition and quality characters of silages.

Model Test of Dual-Buoy Wave Energy Converter using Multi-resonance (다중 공진을 이용한 이중 부이 파력발전장치의 모형실험)

  • Kim, Jeong-Rok;Hyeon, Jong-Wu;Koh, Hyeok-Jun;Kweon, Hyuck-Min;Cho, Il-Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.191-198
    • /
    • 2015
  • In this study, we proposed a new type of dual-buoy wave energy converter (WEC) exploiting multi-resonance and analyzed the experimental results from a model test in a 2-D wave flume. A dual-buoy WEC using multi-resonance has two advantages: high efficiency at the resonant frequencies and the potential to extend the frequency range available to extract wave power from the WEC. The suggested WEC was composed of an outer buoy and an inner buoy sliding vertically inside the outer buoy. As the power take-off device, a linear electric generator (LEG) consisting of permanent magnets and coils fixed at each buoy was adopted. Electricity was produced by the relative heave motion between the two buoys. To search for the optimal shape of a dual-buoy WEC, we conducted experiments on the heave motion of a two-body system in regular waves without an LEG installed. Model tests with six combinations of experimental models were conducted in order to find the motion characteristics of a dual-buoy WEC. It was found that model 2, which included a ring-shaped appendage to move the resonant frequency of the outer buoy toward a high value, showed a higher relative heave response amplitude operator (RAO) curve than model 1. In addition, the double-peak shape of the heave RAO curve shown for model 2 indicated the extension of the frequency range for extracting wave power in irregular waves.

Measurements of relative depth dose rates for a brachytherapy Ir-192 sourceusing an organic scintillator fiber-optic radiation sensor (유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의 상대 깊이 선량율 측정)

  • Shin, Sang-Hun;Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Lee, Bong-Soo;Moon, Joo-Hyun;Kim, Sin;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.462-469
    • /
    • 2008
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator and plastic optical fiber for brachytherapy dosimetry. Also, we have measured relative depth dose rates of Ir-192 source using a fiber-optic sensor and compared them with the results obtained using a conventional EBT film. Cerenkov lights which can be a noise in measuring scintillating light with a fiber-optic sensor are measured and eliminated by using of a background optical fiber. It is expected that a fiber-optic radiation sensor can be used in brachytherapy dosimetry due to its advantages such as a low cost, simple usage and a small volume.

Effect Analysis of Relative Position of Blade on Performance of Micro Gravitational Vortex Turbine in Free Water Surface (자유수면에서 마이크로 중력식 와류 수차 성능에 블레이드의 상대위치 변화가 미치는 영향 분석)

  • Choi, In-Ho;Kim, Jong-Woo;Chung, Gi-Soo
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.196-203
    • /
    • 2022
  • This paper contributed to the understanding of the effect of the blade relative position on performance of micro gravitational vortex turbine in free water surface. In a constant vortex flow, the rotation, voltage and current of micro vortex water turbine were measured according to the position change of the blade installed at the relative vortex height (y/hv) ranging from 0 to 0.778 below the free water surface. The flow rate ranged from 0.0063 to 0.00662 m3/s. The results of the experiments showed that relative positions of the blade affected the performance of vortex water turbine because the distributions of incoming flow velocity and turbulence intensity were changed. The highest amount of the energy generated by the vortex water turbine occurred in the relative vortex height ranging from 0.111 to 0.222. The output power at the relative vortex height of 0.111 was about 2.4 times larger than the relative vortex height of 0.588 below the free water surface.

Economic evaluation on heating systems of apartment complex (공동주택단지 난방시스템들에 대한 경제성 평가)

  • 조금남;윤승호;김원배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.773-783
    • /
    • 1998
  • The heating system for apartment complex may be classified as old systems including central system with steam boiler(S1), gas engine driven heat pump system(S2), system using waste heat(S3) and new systems including mechanical vapor re-compression system with flashing heat exchangers(S4), system using methanol(S5), system using metal hydride (S6). The purpose of the present study is to suggest optimal heating system by technically, economically and environmentally evaluating old and new heating systems of apartment complex from 500 to 3,000 households. Economic evaluation based on the technical evaluation results which estimated heat transfer area of heat exchangers and capacity of equipments was estimated initial investment cost, annual operating cost and relative payback period by considering annual increasing rates of energy cost and interest. Environmental evaluation provided annual generation rate of carbon dioxide. Initial investment cost was cheap in the order of S6, S5, S3, S2, S4, S1, annual operating cost was cheap in the order of S1, S2, S4, S5 and relative payback period was short in the order of S6, S5, S2, S3 and S4. Relative payback period was within 8 years for all scenarios of 3,000 households, and was increased as annual increasing rates of energy cost and interest were increased. As transportation pipe length was increased twice, payback period was increased by 1.4~2.6 time. The effect of temperatures of waste gas and waste water on the relative payback period was small within 0.8 years. The annual generation rate of carbon dioxide was big in the order of S4, S2 and S1. S4 was the most economic system among whole scenarios when S1 was replaced with other scenarios.

  • PDF

Manufacturing of Flexible Patterned Cover Film for Solar Cell by Solution Coating (용액 코팅을 이용한 태양전지용 고분자 유연 패턴필름 제조)

  • Park, Chanwook;Kang, Ho-Jong
    • Polymer(Korea)
    • /
    • v.37 no.5
    • /
    • pp.656-662
    • /
    • 2013
  • The flexible patterned cover film was made by a simple solution coating process using polymethyl methacrylate (PMMA) solution with glass beads. The effect of patterned cover film on the efficiency of solar cell has been investigated. It was found that the relative solar cell efficiency increased up to 3.4% with the incident light angle between $0-90^{\circ}$ by the sphere shape of glass bead coated on the film surface. This was understood that the loss of transmittance and scattering due to the light directional dependency on solar cell were minimized because the light entered glass beads normal to its surface regardless of incident light angle. The maximum relative solar cell efficiency was achieved when glass bead shape on the film is hemisphere and the relative efficiency increased with increasing the amount of glass bead on the film surface. However, too much glass beads on the film surface resulted in the lower relative solar cell efficiency due to the lowering of transmittance as well as the occurring of light interference.

Comparison of Growth Performances in Seedling of Allium microdictyon Prokh. and Allium ochotense Prokh. (산마늘과 울릉산마늘 유묘의 생장특성 비교)

  • Lee,K.C.;Kim,H.S.;Han,S.K.;Lee,K.M.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.19 no.1
    • /
    • pp.129-137
    • /
    • 2017
  • This study was conducted to investigate of growth performances and net assimilation rate(NAR) of Allium microdictyon Prokh. distributed inland and Allium ochotense Prokh. originated Ulleung-do. The Allium microdictyon on the growth of 1-2 years showed the largest relative growth rate, and showed high relative growth from three to four years. Allium ochotense on the growth from one year to three years showed high relative growth rate. The T/R rate of Allium ochotense of 2~5years was in the range of 0.4~0.5. However, The T/R rate of Allium microdictyon was increased as increasing with age. This implies that Allium microdictyon was consumed more energy on growing subterranean part. The LWR of 1~3years old Allium ochotense. was showed more smaller than 4~5years old. It seems that the growth characteristics of Allium ochotense 1-3 years after sowing the leaf growth consume more energy than Allium microdictyon. Net assimilation rate(NAR) of Allium ochotense for 1-3 years after sowing was higher than that of Allium microdictyon. In this time, the material of Allium ochotense has a higher production efficiency can be seen indirectly.

Effects of Bar Deformation Height on Bond Degradation Subject to Cyclic loading (반복하중시 철근 마디높이에 따른 부착 손상특성)

  • Lee, Jae-Yuel;Kim, Byong-Kook;Hong, Gi-Suop;Choi, Oan-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2003
  • One of the reasons for brittle failure in reinforced concrete structures subjected to severe earthquake is due to large local bond-slippage of bars resulting in fast bond degradation between reinforcing bars and concrete. This study aims to evaluate effects of bar deformation height on bond performance, specially, bond degradation under cyclic loading. Bond test specimens were constructed with machined bars with high relative rib areas. The degree of confinement by transverse bars is also another key parameters in this bond test. From test results, amounts of energy dissipation are calculated and compared for each parameter. Test results show that bond strength and stiffness drops significantly as cycles increases. The confinement and high relative rib area are effective to delay bond degradation, as the reduction of bond strength of cyclic loading compared to monotonic loading decreased for bars with large confinement and high relative rib areas. The energy dissipation also increases as the degree of confinement and relative rib area increases. However, tested bars with very high rib areas show that the bond may be damaged at relatively small slip because of high stiffness. The study will help to understand the bond degradation mechanism due to bar deformation height under cyclic loading and be useful to develop new deformed bars with high relative rib areas.

Energy demand analysis according to window size and performance for Korean multi-family buildings

  • Huh, Jung-Ho;Mun, Sun-Hye
    • Architectural research
    • /
    • v.15 no.4
    • /
    • pp.201-206
    • /
    • 2013
  • Special attention is required for the design of windows due to their high thermal vulnerability. This paper examines the problems that might arise in the application of the u-value, by reflecting the changes in the u-value of the window, depending on the window-to-wall ratio obtained in an energy demand analysis. Research indicates that the u-value of a window increases with an increase in the difference between the u-values of the frames and the glass. Relative to the changes in the u-value of the windows, the energy demand varied from 1.3% to 9.3%. Windows with a g-value of 0.3 or 0.5 displayed a higher energy demand than windows with a g-value of 0.7. Therefore, when the difference between the performance of the glass and the frame is significant, especially when the g-value is small, a modified heat transmission coefficient should be applied to the window size during the evaluation of the building energy demand.

A Study of Wind Energy Conversion System by a Secondary Control Hydrostatic Transmission (2차측 제어 정유압 변속기를 이용한 풍력발전시스템에 관한 연구)

  • Do, H.T.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • Wind energy has been more and more important and contributive in the energy utilization of the world. This paper proposed a novel method for Wind Energy Conversion System (WECS), in which a secondary control hydrostatic transmission (SC-HST) with two hydraulic accumulators, were employed for wind energy conversion system. This approach can absorb the excessive power of turbine, keep the generator from over-speed and maintain the speed of generator in low speed of turbine. A PID controller was designed for speed control to track a predefined speed. The simulation results indicated that the speed of the generator was ensured with the relative error less than 2%; and the efficiency of the proposed system was 70.4%.